Open Access. Powered by Scholars. Published by Universities.®

Robotics Commons™

Open Access. Powered by Scholars. Published by Universities.®

2011

Discipline
Institution
Keyword
Publication
Publication Type

Articles 31 - 41 of 41

Full-Text Articles in Robotics

A Midsummer Night’S Dream (With Flying Robots), Robin Murphy, Dylan Shell, Amy Guerin, Brittany Duncan, Benjamin Fine, Kevin Pratt, Takis Zourntos Jan 2011

A Midsummer Night’S Dream (With Flying Robots), Robin Murphy, Dylan Shell, Amy Guerin, Brittany Duncan, Benjamin Fine, Kevin Pratt, Takis Zourntos

School of Computing: Faculty Publications

Seven flying robot “fairies” joined human actors in the Texas A&M production of William Shakespeare’s A Midsummer Night’s Dream. The production was a collaboration between the departments of Computer Science and Engineering, Electrical and Computer Engineering, and Theater Arts. The collaboration was motivated by two assertions. First, that the performing arts have principles for creating believable agents that will transfer to robots. Second, the theater is a natural testbed for evaluating the response of untrained human groups (both actors and the audience) to robots interacting with humans in shared spaces, i.e., were believable agents created? The production used two types …


Autonomous Mobility And Manipulation Of A 9-Dof Wmra, William Garrett Pence Jan 2011

Autonomous Mobility And Manipulation Of A 9-Dof Wmra, William Garrett Pence

USF Tampa Graduate Theses and Dissertations

The wheelchair-mounted robotic arm (WMRA) is a 9-degree of freedom (DoF) assistive system that consists of a 2-DoF modified commercial power wheelchair and a custom 7-DoF robotic arm. Kinematics and control methodology for the 9-DoF system that combine mobility and manipulation have been previously developed and implemented. This combined control allows the wheelchair and robotic arm to follow a single trajectory based on weighted optimizations. However, for the execution of activities of daily living (ADL) in the real-world environment, modified control techniques have been implemented.

In order to execute macro ADL tasks, such as a "go to and pick up" …


Robotic Testing Of Proximal Tibio-Fibular Joint Kinematics For Measuring Instability Following Total Knee Arthroplasty, Wael K. Barsoum, Ho H. Lee, Trevor G. Murray, Robb Colbrunn, Alison K. Klika, S. Butler, Antonie J. Van Den Bogert Jan 2011

Robotic Testing Of Proximal Tibio-Fibular Joint Kinematics For Measuring Instability Following Total Knee Arthroplasty, Wael K. Barsoum, Ho H. Lee, Trevor G. Murray, Robb Colbrunn, Alison K. Klika, S. Butler, Antonie J. Van Den Bogert

Mechanical Engineering Faculty Publications

Pain secondary to instability in total knee arthroplasty (TKA) has been shown to be major cause of early failure. In this study, we focused on the effect of instability in TKA on the proximal tibio-fibular joint (PTFJ). We used a robotics model to compare the biomechanics of the PTFJ in the native knee, an appropriately balanced TKA, and an unbalanced TKA. The tibia (n = 5) was mounted to a six-degree-of-freedom force/torque sensor and the femur was moved by a robotic manipulator. Motion at the PTFJ was recorded with a high-resolution digital camera system. After establishing a neutral position, …


Reactivation Of A Six-Degree-Of-Freedom Repeated Impact Machine Using Programmable Logical Controller (Plc), Cheng Lin Jan 2011

Reactivation Of A Six-Degree-Of-Freedom Repeated Impact Machine Using Programmable Logical Controller (Plc), Cheng Lin

Engineering Technology Faculty Publications

Reactivation of a six-degree-of-freedom impact machine using Programmable Logical Control (PLC) is presented. The output from the machine is the history of accelerations collected from accelerometers attached at the testing article and a load cell mounted at the rubber pad where the impact occurs. Readings of the acceleration and impact force are sent to a PC for analysis through a data acquisition device (USB 6251) and Labview software provided by National Instrument (NI). Result shows that the machine can repeatedly generate an impact force up to eleven Gs. Demonstration of the project can be used as one of labs in …


Development And Human Performance Evaluation Of A Ground Vehicle Robotic Force-Feedback Tele-Operation System, Ankur Saraf Jan 2011

Development And Human Performance Evaluation Of A Ground Vehicle Robotic Force-Feedback Tele-Operation System, Ankur Saraf

Wayne State University Theses

ABSTRACT

DEVELOPMENT AND HUMAN PERFORMANCE EVALUATION OF A GROUND VEHICLE ROBOTIC FORCE-FEEDBACK TELE-OPERATION SYSTEM

by

ANKUR SARAF

May 2011

Advisor: Dr. Abhilash K. Pandya.

Major: Electrical Engineering.

Degree: Master of Science.

Modern tele-operation systems are trying to take into account haptic and audio information in addition to visual data to provide as feedback to the tele-operator.This research emphasizes on the development of hardware and software architecture to enhance the tele-operation capabilities of omni-directional inspection robot (ODIS). The system enhances the tele-operation capabilities by introducing force-feedback to the tele-operators. The conventional joystick is replaced with Novint Falcon haptic joystick which gets …


Control Of A Single Ground Vehicle Using Aerial And Onboard Camera Views, Vishal Lowalekar Jan 2011

Control Of A Single Ground Vehicle Using Aerial And Onboard Camera Views, Vishal Lowalekar

Wayne State University Theses

Controlling a ground vehicle using only onboard and aerial camera views, can be a tedious task, as it is challenging for the operator to estimate information about the robots location and orientation using only these view. However the visual data can be sufficient for computerized calculation of this information even in the absence of other sensors. This approach is of interest to the military because the use of passive sensors instead of active sensors (e.g. LIDAR) would be easier and more reliable and would not give off detectable signatures.

The goal of this research was to control a ground vehicle …


Evidence Supporting Measure Of Similarity For Reducing The Complexity In Information Fusion, Florentin Smarandache, Jean Dezert, Xinde Li, Xinhan Huang Jan 2011

Evidence Supporting Measure Of Similarity For Reducing The Complexity In Information Fusion, Florentin Smarandache, Jean Dezert, Xinde Li, Xinhan Huang

Branch Mathematics and Statistics Faculty and Staff Publications

This paper presents a new method for reducing the number of sources of evidence to combine in order to reduce the complexity of the fusion processing. Such a complexity reduction is often required in many applications where the real-time constraint and limited computing resources are of prime importance. The basic idea consists in selecting, among all sources available, only a subset of sources of evidence to combine. The selection is based on an evidence supporting measure of similarity (ESMS) criterion which is an efficient generic tool for outlier sources identification and rejection. The ESMS between two sources of evidence can …


Optimal Port Placement And Automated Robotic Positioning For Instrumented Laparoscopic Biosensors, Brady King Jan 2011

Optimal Port Placement And Automated Robotic Positioning For Instrumented Laparoscopic Biosensors, Brady King

Wayne State University Dissertations

OPTIMAL SURGICAL PORT PLACEMENT AND AUTOMATED ROBOTIC POSITIONING FOR RAMAN AND OTHER BIOSENSORS

by

BRADY KING

January 2011

Advisors: Dr. Abhilash Pandya, Dr. Darin Ellis, Dr. Le Yi Wang, and Dr. Greg Auner

Major: Computer Engineering

Degree: Doctor of Philosophy

Medical biosensors can provide new information during minimally invasive and robotic surgical procedures. However, these biosensors have significant physical limitations that make it difficult to find optimal port locations and place them in vivo. This dissertation explores the application of robotics and virtual/augmented reality to biosensors to enable their optimal use in vivo.

In the first study, human …


Robotic Hand Evaluation Based On Task Specific Kinematic Requirements, Carlos Rafael Neninger Jan 2011

Robotic Hand Evaluation Based On Task Specific Kinematic Requirements, Carlos Rafael Neninger

USF Tampa Graduate Theses and Dissertations

With the rise autonomous and robotic systems in field applications, the need for dexterous, highly adaptable end effectors has become a major research topic. Control mechanisms of robotics hands with a high number independent actuators is recognized as a complex, high dimensional problem, with exponentially complex algorithms. However, recent studies have shown that human hand motion possesses very high joint correlation which translates into a set of predefined postures, or synergies. The hand produces a motion using a complementing contribution of multiple joints, called synergies. The similarities place variables onto a common dimensional space, effectively reducing the number of independent …


Utilizing A Computational Model For The Design Of A Passive Dynamic Walker, Craig Alan Honeycutt Jan 2011

Utilizing A Computational Model For The Design Of A Passive Dynamic Walker, Craig Alan Honeycutt

USF Tampa Graduate Theses and Dissertations

Recent interest in using passive dynamic walkers (PDWs) for gait rehabilitation studies has presented a need for a robust, easily built mechanism. Unfortunately, these passive robots are hypersensitive to many variables outside of the usual design considerations that are studied when constructing them. By accentuating previous failures instead of suppressing them, this thesis presents a number of problematic situations commonly experienced when testing and tuning a PDW.

Further, through a complete design of a 4-legged PDW with knees, simple design axioms brought about by myself and others are put into a practical context and applied directly to design. This thesis …


Asymmetric Passive Dynamic Walker Used To Examine Gait Rehabilitation Methods, John Sushko Jan 2011

Asymmetric Passive Dynamic Walker Used To Examine Gait Rehabilitation Methods, John Sushko

USF Tampa Graduate Theses and Dissertations

Testing gait rehabilitation devices on humans can be a difficult task, due to the effects of the neurological controls of the human body. This thesis advances the use of a passive dynamic walker (PDW) tuned to have asymmetric gait patterns similar to those with physical impairments to test rehabilitation devices. A passive dynamic walker is a multipendulum system that has a stable gait pattern when walking down a slope without any energy inputs except the forces due to gravity. A PDW model is better suited for testing rehabilitation devices because it has been shown to resemble human gait and separates …