Designing A Biomimetic Testing Platform For Actuators In A Series-Elastic Co-Contraction System, Ryan Tyler Schroeder Dec 2014

Designing A Biomimetic Testing Platform For Actuators In A Series-Elastic Co-Contraction System, Ryan Tyler Schroeder

UNLV Theses, Dissertations, Professional Papers, and Capstones

Actuators determine the performance of robotic systems at the most intimate of levels. As a result, much work has been done to assess the performance of different actuator systems. However, biomimetics has not previously been utilized as a pretext for tuning a series elastic actuator system with the purpose of designing an empirical testing platform. Thus, an artificial muscle tendon system has been developed in order to assess the performance of two distinct actuator types: (1) direct current electromagnetic motors and (2) ultrasonic rotary piezoelectric motors. Because the design of the system takes advantage of biomimetic operating principles such as …


Effects Of Hip And Ankle Moments On Running Stability: Simulation Of A Simplified Model, Rubin C. Cholera Oct 2014

Effects Of Hip And Ankle Moments On Running Stability: Simulation Of A Simplified Model, Rubin C. Cholera

Open Access Theses

In human running, the ankle, knee, and hip moments are known to play different roles to influence the dynamics of locomotion. A recent study of hip moments and several hip-based legged robots have revealed that hip actuation can significantly improve the stability of locomotion, whether controlled or uncontrolled. Ankle moments are expected to also significantly affect running stability, but in a different way than hip moments. Here we seek to advance the current theory of dynamic running and associated legged robots by determining how simple open-loop ankle moments could affect running stability. We simulate a dynamical model, and compare it …


Principle Of Bio-Inspired Insect Wing Rotational Hinge Design, Fan Fei Oct 2014

Principle Of Bio-Inspired Insect Wing Rotational Hinge Design, Fan Fei

Open Access Theses

A principle for designing and fabricating bio-inspired miniature artificial insect flapping wing using flexure rotational hinge design is presented. A systematic approach of selecting rotational hinge stiffness value is proposed. Based on the understanding of flapping wing aerodynamics, a dynamic simulation is constructed using the established quasi-steady model and the wing design. Simulations were performed to gain insight on how different parameters affect the wing rotational response. Based on system resonance a model to predict the optimal rotational hinge stiffness based on given wing parameter and flapping wing kinematic is proposed. By varying different wing parameters, the proposed method is …


Biobotic Solutions, Michael Joseph Iseman May 2014

Biobotic Solutions, Michael Joseph Iseman

Finance Undergraduate Honors Theses

BioBotic Solutions is a business plan that was created and used to compete in national business competitions. The business takes an in-depth look into the pathology industry, which has an impact on nearly 75% of all patient diagnosis, and proposes a change- to automate a process currently done manually, and introduce to proprietary products, a robotic arm and a new container. The solution addresses a $500M annual opportunity, and will reduce both errors and costs for mid/large size laboratories.


Evaluating And Training Intraoperative Analysis Of The Mitral Valve, Neil A. Tenenholtz Jan 2013

Evaluating And Training Intraoperative Analysis Of The Mitral Valve, Neil A. Tenenholtz

Link Foundation Modeling, Simulation and Training Fellowship Reports

Mitral valve repair is the recommended method of treating valve incompetency. However, the procedure is quite difficult and, as a result, underperformed due to surgeon’s need to predict the closed valve shape of the patient’s arrested heart. While the interactive process of predicting closed valve shape is achieved by physically manipulating valve tissue (known as valve analysis), surgical training consists of traditional, non-interactive pedagogy (e.g., book-based learning and lectures) followed by an apprenticeship model where the trainee is gradually given hands-on experience, resulting in post-medical school training that is often 10 years or greater. The continuing education of practicing cardiac …


Polygrasp: Reach; Myoelectric Prosthetic Hand Iteration, Devon Patrick Augustus, Mighells Blaed Deuel, Ian Noel Fraser, Nicholas Philip Moesser Jun 2012

Polygrasp: Reach; Myoelectric Prosthetic Hand Iteration, Devon Patrick Augustus, Mighells Blaed Deuel, Ian Noel Fraser, Nicholas Philip Moesser

Mechanical Engineering

Amputations are a common occurrence in soldiers returning home who have suffered the effects of IED and munitions explosions. For upper limb amputees, trans-radial amputations are the most common. Traditional hook devices do not offer an adequate level of normalcy for users, prompting the use of myoelectric devices. While current myoelectric devices do offer a more natural experience, they come with a host of other problems that makes their adoption by service personnel not desirable or not permitted by the VA. PolyGrasp Reach seeks to reduce weight and cost and improve performance. This addresses several of the issues with devices …


Techniques For Sensor-Integrated Robotic Systems: Raman Spectra Analysis, Image Guidance, And Kinematic Calibration, Luke Anthony Reisner Jan 2012

Techniques For Sensor-Integrated Robotic Systems: Raman Spectra Analysis, Image Guidance, And Kinematic Calibration, Luke Anthony Reisner

Wayne State University Dissertations

Robotics and sensor technology have made impressive advancements over the years. There are now robotic systems that help perform surgeries or explore the surface of Mars, and there are sensors that detect trace amounts of explosives or identify diseased human tissue. The most powerful systems integrate robots and sensors, which are natural complements to each other. Sensors can provide information that might otherwise be unavailable due to indirect robotic manipulation (e.g., images of the target environment), and robots can provide suitably precise positioning of an analytical sensor.

To have an effective sensor-integrated robotic system, multiple capabilities are needed in the …


Cyberknife Radiation Modeling: Effects Of Relaxed Translational And Rotational Constraints On Healthy Tissue Irradiation, Sudha Bhavaroop Potineni Jul 2011

Cyberknife Radiation Modeling: Effects Of Relaxed Translational And Rotational Constraints On Healthy Tissue Irradiation, Sudha Bhavaroop Potineni

Electrical & Computer Engineering Theses & Dissertations

The Cyberknife system is a robotic radio surgery instrument that is used to treat cancers in different parts of the human body. Because of its accuracy and precision, it has become one of the best radio surgery systems in the world. However, even with Cyberknife the treatment time for one session takes from 30 minutes up to 120 minutes depending on the size, shape, and position of the tumor in the human body. In this research, a solution is presented to aid in reducing this long treatment time. An algorithm is developed which simulates the amount of the healthy tissue …


Robotic Testing Of Proximal Tibio-Fibular Joint Kinematics For Measuring Instability Following Total Knee Arthroplasty, Wael K. Barsoum, Ho H. Lee, Trevor G. Murray, Robb Colbrunn, Alison K. Klika, S. Butler, Antonie J. Van Den Bogert Jan 2011

Robotic Testing Of Proximal Tibio-Fibular Joint Kinematics For Measuring Instability Following Total Knee Arthroplasty, Wael K. Barsoum, Ho H. Lee, Trevor G. Murray, Robb Colbrunn, Alison K. Klika, S. Butler, Antonie J. Van Den Bogert

Mechanical Engineering Faculty Publications

Pain secondary to instability in total knee arthroplasty (TKA) has been shown to be major cause of early failure. In this study, we focused on the effect of instability in TKA on the proximal tibio-fibular joint (PTFJ). We used a robotics model to compare the biomechanics of the PTFJ in the native knee, an appropriately balanced TKA, and an unbalanced TKA. The tibia (n = 5) was mounted to a six-degree-of-freedom force/torque sensor and the femur was moved by a robotic manipulator. Motion at the PTFJ was recorded with a high-resolution digital camera system. After establishing a neutral position, …


Nonlinear Control Strategy For A Cost Effective Myoelectric Prosthetic Hand, Cristian Federico Pasluosta Oct 2010

Nonlinear Control Strategy For A Cost Effective Myoelectric Prosthetic Hand, Cristian Federico Pasluosta

Doctoral Dissertations

The loss of a limb tremendously impacts the life of the affected individual. In the past decades, researchers have been developing artificial limbs that may return some of the missing functions and cosmetics. However, the development of dexterous mechanisms capable of mimicking the function of the human hand is a complex venture. Even though myoelectric prostheses have advanced, several issues remain to be solved before an artificial limb may be comparable to its human counterpart. Moreover, the high cost of advanced limbs prevents their widespread use among the low-income population.

This dissertation presents a strategy for the low-level of control …


Towards Supervised Autonomous Task Completion Using An In Vivo Surgical Robot, Jason J. Dumpert Oct 2009

Towards Supervised Autonomous Task Completion Using An In Vivo Surgical Robot, Jason J. Dumpert

Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research

Laparoscopy is a minimally invasive alternative to traditional abdominal surgery. Unlike traditional surgery, a laparoscopic procedure can be completed using small incisions. The use of these small incision results in reduced pain to the patient, shorter recovery times, and less trauma to skin, muscle and other tissues. However, these benefits to the patient are offset by the increased difficulty to the surgeon performing the procedure. These difficulties include reduced dexterity, reduced perception, and longer procedure times. The use of small in vivo robotic devices in minimally invasive surgery is one possible solution to these problems. The movement of these devices …