Open Access. Powered by Scholars. Published by Universities.®

Structural Engineering Commons™

Open Access. Powered by Scholars. Published by Universities.®

2012

Discipline
Institution
Keyword
Publication
Publication Type

Articles 61 - 90 of 156

Full-Text Articles in Structural Engineering

Push Tests On Innovative Shear Connector For Composite Beam With Cold-Formed Steel Section, S. O. Bamaga, M. M. Tahir, C. S. Tan Aug 2012

Push Tests On Innovative Shear Connector For Composite Beam With Cold-Formed Steel Section, S. O. Bamaga, M. M. Tahir, C. S. Tan

CCFSS Proceedings of International Specialty Conference on Cold-Formed Steel Structures (1971 - 2018)

In this study, experimental tests were conducted to investigate the ductility and strength capacity of new shear connector. Push test specimens were prepared and tested according to EN1994-1-1 standard. The push test specimen consists of two cold-formed steel lipped channel sections oriented back-to-back to form an I-section beam, transverse metal deck and normal concrete slabs grade C25/30. Angle brackets were obtained from the same section of the beam and fastened to the web of steel beam to provide the shear connection. Two shear connectors were tested namely; “SC1” and “SC2” shear connectors. Both shear connectors showed a ductile behavior and …


An Explicit, Dynamic Finite Element Model For The Local Failure Of Cold-Formed Trapezoidal Sheeting, Hèrm Hofmeyer Aug 2012

An Explicit, Dynamic Finite Element Model For The Local Failure Of Cold-Formed Trapezoidal Sheeting, Hèrm Hofmeyer

CCFSS Proceedings of International Specialty Conference on Cold-Formed Steel Structures (1971 - 2018)

Trapezoidal sheeting, made of cold-formed, thin-walled steel, is widely used for the construction of cladding and roofs. At an interior support, the sheeting is subject to bending moments and a concentrated load, which leads to possible failure followed by two post-failure modes: the yield-arc and yield-eye modes. Until recently, it was not fully understood why a specific post-failure mode occurs and it was suggested that mode-jumping of the compressed sheeting flange may influence the mode occurring. This paper presents new research, in which both the compressed flange in isolation and the sheeting are modeled by using an explicit, dynamic finite …


The Effects Of Bolt Pretension, In-Plane Eccentricity, And Friction On The Ductility Of Block Shear Connections, Kevin M. Zmetra Aug 2012

The Effects Of Bolt Pretension, In-Plane Eccentricity, And Friction On The Ductility Of Block Shear Connections, Kevin M. Zmetra

Master's Theses

Block shear is a complex failure mechanism in bolted and welded steel components such as gusset plates, webs of coped beams, angles and tees. It presumes a combination of tension rupture and shear yield. Multiple variables affect the block shear capacity and ductility of a connection. This study investigates the effects of bolt pretension, connection eccentricity and friction force transfer through a series of destructive experiments followed by refined finite element simulation. Clamping forces create a complex triaxial stress field compounded by the stress concentration at the bolt holes. In-plane load eccentricity with respect to the centerline of the connection …


Seismic Performance Of Steel Sheathed Cold-Formed Steel Shear Walls, Mehran Zeynalian Dastjerdi, Hamid Reza Ronagh Aug 2012

Seismic Performance Of Steel Sheathed Cold-Formed Steel Shear Walls, Mehran Zeynalian Dastjerdi, Hamid Reza Ronagh

CCFSS Proceedings of International Specialty Conference on Cold-Formed Steel Structures (1971 - 2018)

In this paper the performance of steel sheathed cold-formed steel shear walls is evaluated by testing seven full scale walls under cyclic and monotonic loading. Of particular interest are the specimens’ maximum lateral load capacity and deformation behaviour. The study also looks at the failure modes of the system and investigates the main factors contributing to the ductile response of the CFS walls in order to suggest improvements so that the steel shear walls respond plastically with a significant drift and without any risk of brittle failure, such as failure in the connections. The walls tested are of different configurations …


Numerical Modelling And Calibration Of Cfs Framed Shear Walls Under Dynamic Loading, I. Shamim, C. A. Rogers Aug 2012

Numerical Modelling And Calibration Of Cfs Framed Shear Walls Under Dynamic Loading, I. Shamim, C. A. Rogers

CCFSS Proceedings of International Specialty Conference on Cold-Formed Steel Structures (1971 - 2018)

This paper describes the numerical modeling using OpenSees of steel sheathed cold-formed steel framed shear wall test specimens under dynamic loading. Two modeling phases were carried out; the first phase comprised non-linear models calibrated using existing reversed cyclic shear wall test data, and the second phase involved more advanced models calibrated using data from dynamic shake table tests of single- and double-storey shear walls as well as other ancillary test programs. The second phase models incorporated the behaviour of the hold-downs, floor framing and blocked bare frame, in addition to the sheathing. The final calibrated models were able to accurately …


Improved Reliability Determination When Testing Cold-Formed Steel Components, V. M. Zeinoddini, B. W. Schafer Aug 2012

Improved Reliability Determination When Testing Cold-Formed Steel Components, V. M. Zeinoddini, B. W. Schafer

CCFSS Proceedings of International Specialty Conference on Cold-Formed Steel Structures (1971 - 2018)

The objectives of this paper are to (a) determine the sensitivity of the reliability calculations in Chapter F of the AISI Specification (AISI-S100-07) to controlling load combinations and loading ratios, and (b) develop a more robust alternative for the use of Chapter F. To complete this study the bias factors and variances for all loading conditions are established. In addition, a range of practical load ratios is agreed upon. Parametric studies are performed to explore load case and load ratio dependency for use in the determination of the resistance factor, Φ; specifically, the pre-factor term CΦ and the load variance …


Self-Shape Optimisation Of Cold-Formed Steel Columns, Benoit P. Gilbert, Timothee J-M Savoyat, Lip H. The Aug 2012

Self-Shape Optimisation Of Cold-Formed Steel Columns, Benoit P. Gilbert, Timothee J-M Savoyat, Lip H. The

CCFSS Proceedings of International Specialty Conference on Cold-Formed Steel Structures (1971 - 2018)

This paper presents the optimisation of cold-formed steel open columns using the recently developed self-shape optimisation method that aims to discover new profile shapes. The strength of the cold-formed steel sections is calculated using the Direct Strength Method, and the rules developed in the present work to automatically determine the local and distortional elastic buckling stresses from the Finite Strip and constrained Finite Strip Methods are discussed. The rules are verified against conventional and optimum sections yielded in this research, and found to accurately predict the elastic buckling stresses. The principles behind the self-shape optimisation method are summarised herein and …


Compression-Tension Hysteretic Response Of Cold-Formed Steel C-Stection Framing Members, D. Padilla-Llano, C. D. Moen, M. Eatherton, L. Mcanallen, T. Bruce Aug 2012

Compression-Tension Hysteretic Response Of Cold-Formed Steel C-Stection Framing Members, D. Padilla-Llano, C. D. Moen, M. Eatherton, L. Mcanallen, T. Bruce

CCFSS Proceedings of International Specialty Conference on Cold-Formed Steel Structures (1971 - 2018)

This paper summarizes results from an experimental program designed to evaluate the tension-compression cyclic axial response of cold-formed steel C-section structural framing members. A new cyclic loading protocol for cold formed steel members is presented that defines the target axial displacement based on elastic buckling parameters. The protocol is used to explore the cyclic response of members experiencing local buckling, distortional buckling, and global buckling deformation. In the experiments, post-bucking energy dissipation was observed along with tension stretching and softening. The quantity of dissipated energy per cycle increased as cross-section and global slenderness decreased. Specimens experiencing local and distortional buckling …


Design Of Nonstructural Members In Accordance With Aisi S220, Roger A. Laboube, H. Chen, J. W. Larson Aug 2012

Design Of Nonstructural Members In Accordance With Aisi S220, Roger A. Laboube, H. Chen, J. W. Larson

CCFSS Proceedings of International Specialty Conference on Cold-Formed Steel Structures (1971 - 2018)

AISI S220, the North American Standard for Cold-Formed Steel Framing - Nonstructural Members, was developed in 2011 to help clearly delineate and eliminate confusion between the requirements for cold-formed steel structural members and nonstructural members. This paper is intended as an introduction to this standard and as an illustrative guide for applying the provisions to the design of nonstructural members.


Direct Strength Method Of Design For Shear Of Cold-Formed Channels Based On A Shear Signature Curve, Gregory J. Hancock, Cao Hung Pham Aug 2012

Direct Strength Method Of Design For Shear Of Cold-Formed Channels Based On A Shear Signature Curve, Gregory J. Hancock, Cao Hung Pham

CCFSS Proceedings of International Specialty Conference on Cold-Formed Steel Structures (1971 - 2018)

Thin-walled sections in compression and/or bending may undergo one of the three modes of local, distortional or overall (Euler) buckling, or combinations of these. The Semi-Analytical Finite Strip Method (SAFSM) developed by YK Cheung has been widely used in computer software (THIN-WALL, CUFSM) to develop the signature curve of the buckling stress versus buckling half wavelength for a thin-walled section under compression or bending to allow identification of these modes. The minimum points on the signature curve are now used in the Direct Strength Method (DSM) of design of cold-formed sections in the American Specification and Australian/New Zealand Standard for …


Behaviour Of Litesteel Beams Subject To Combined Shear And Bending Actions, P. Keerthan, D. Hughes, M. Mahendran Aug 2012

Behaviour Of Litesteel Beams Subject To Combined Shear And Bending Actions, P. Keerthan, D. Hughes, M. Mahendran

CCFSS Proceedings of International Specialty Conference on Cold-Formed Steel Structures (1971 - 2018)

This paper presents the details of a numerical study of a cold-formed steel beam known as LiteSteel Beam (LSB) subject to combined shear and bending actions. The LSB sections are produced by a patented manufacturing process involving simultaneous cold-forming and electric resistance welding. They have a unique shape of a channel beam with two rectangular hollow flanges. To date, however, no investigation has been conducted into the strength of LSB sections under combined shear and bending actions. Hence a numerical study was undertaken to investigate the behaviour and strength of LSBs subject to combined shear and bending actions. In this …


Shear Buckling Of Thin-Walled Channel Sections With Complex Stiffened Webs, Song Hong Pham, Cao Hung Pham, Gregory J. Hancock Aug 2012

Shear Buckling Of Thin-Walled Channel Sections With Complex Stiffened Webs, Song Hong Pham, Cao Hung Pham, Gregory J. Hancock

CCFSS Proceedings of International Specialty Conference on Cold-Formed Steel Structures (1971 - 2018)

For cold-formed channel section design in shear, the traditional approach has been to investigate shear plate buckling in the web alone. Recently, an improvement in the elastic buckling stress of the whole thin-walled channel section including flanges and lips in pure shear has been demonstrated. For webs with relatively large depth to thickness ratios, the local buckling mode in shear occurs mainly in web. The structural efficiency of such a web can be improved by adding intermediate stiffeners cold-formed longitudinally in the middle of the webs. This paper presents numerical buckling analyses implemented by means of the Semi-Analytical Finite Strip …


The Effects Of Web Holes On Web Crippling Strength Of Cold-Formed Steel Channels Under End-Two-Flange Loading Condition, Asraf Uzzaman, James B. P. Lim, David Nash, Jim Rhodes, Ben Young Aug 2012

The Effects Of Web Holes On Web Crippling Strength Of Cold-Formed Steel Channels Under End-Two-Flange Loading Condition, Asraf Uzzaman, James B. P. Lim, David Nash, Jim Rhodes, Ben Young

CCFSS Proceedings of International Specialty Conference on Cold-Formed Steel Structures (1971 - 2018)

Cold-formed steel sections are often used as wall studs or floor joists; such sections often include web holes for ease of installation of the services. Web crippling at points of concentrated, or localised, load or reaction in thin-walled beams is well known to be a significant problem, particularly in the case of beams with slender webs, and is of high importance in the field of cold-formed steel members, as such members are generally not stiffened against this type of loading. In this paper, a combination of experimental tests and non-linear elastoplastic finite element analyses are used to investigate the effect …


Behavior Of Composite Beams With Cold-Formed Steel Joists And Concrete Slab, Cheng-Tzu Thomas Hsu, Pedro R. Munoz, Sun Punurai, Yazdan Majdi, Wonsiri Punurai Aug 2012

Behavior Of Composite Beams With Cold-Formed Steel Joists And Concrete Slab, Cheng-Tzu Thomas Hsu, Pedro R. Munoz, Sun Punurai, Yazdan Majdi, Wonsiri Punurai

CCFSS Proceedings of International Specialty Conference on Cold-Formed Steel Structures (1971 - 2018)

A new composite beam and floor system has been developed herein to achieve a stronger strength and ductility, as well as to yield a more economical design purpose. This new composite beam system consists of three elements: reinforced concrete slab on corrugated cold-formed metal, back to back cold-formed steel joists, and cold-formed furring shear connector. The shear connectors are screwed through the top flange of the support joists in order to provide vertical interlocking and horizontal shear resistant between the concrete slab and the cold-formed steel joists. The self-drill fasteners are used for fastening the furring shear connector through the …


Design Of Perforated Industrial Storage Rack Columns For Distortional Buckling, Teoman Peköz, Güven Kıymaz, Miquel Casafont, Maria Magdalena Pastor, Jordi Bonada Aug 2012

Design Of Perforated Industrial Storage Rack Columns For Distortional Buckling, Teoman Peköz, Güven Kıymaz, Miquel Casafont, Maria Magdalena Pastor, Jordi Bonada

CCFSS Proceedings of International Specialty Conference on Cold-Formed Steel Structures (1971 - 2018)

The results of an on-going research program to develop a design procedure for perforated industrial storage rack columns are presented. The design procedure includes the effects of distortional buckling. The types of columns studied include those commonly used in Europe and some that are used in the US. The design procedure is being developed based on finite element studies verified by physical testing. The design procedure involves the use of the current US rack column design approach with an extension to distortional buckling with Finite Strip Method (FSM) solutions and Direct Strength Method (DSM) approaches. The approach originally developed for …


An Efficient Genetic Algorithm For The Design Optimization Of Cold-Formed Steel Portal Frame Buildings, Duoc T. Phan, James B. P. Lim, Tiku T. Tanyimboh, Wei Sha Aug 2012

An Efficient Genetic Algorithm For The Design Optimization Of Cold-Formed Steel Portal Frame Buildings, Duoc T. Phan, James B. P. Lim, Tiku T. Tanyimboh, Wei Sha

CCFSS Proceedings of International Specialty Conference on Cold-Formed Steel Structures (1971 - 2018)

The design optimization of cold-formed steel portal frame buildings is considered in this paper. The real-coded genetic algorithm (GA) optimizer proposed considers both building’s topology (i.e. frame spacing and pitch) and cross-sectional sizes of the main structural members as the decision variables that are optimized. Previous GAs in the literature were characterized by poor convergence including slow progress that usually results in excessive computation times and/or frequent failure to achieve an optimal or near-optimal solution. This is the main issue addressed in this paper. In an effort to improve the performance of the conventional GA, a niching strategy is presented …


Advanced Design Optimization Of Cold-Formed Steel Portal Frame Buildings, Duoc T. Phan, James B. P. Lim, Tiku T. Tanyimboh, Wei Sha Aug 2012

Advanced Design Optimization Of Cold-Formed Steel Portal Frame Buildings, Duoc T. Phan, James B. P. Lim, Tiku T. Tanyimboh, Wei Sha

CCFSS Proceedings of International Specialty Conference on Cold-Formed Steel Structures (1971 - 2018)

The design optimization of cold-formed steel portal frame buildings is considered in this paper. The objective function is based on the cost of the members for the main frame and secondary members (i.e., purlins, girts, and cladding for walls and roofs) per unit area on the plan of the building. A realcoded niching genetic algorithm is used to minimize the cost of the frame and secondary members that are designed on the basis of ultimate limit state. It is shown that the proposed algorithm shows effective and robust capacity in generating the optimal solution, owing to the population’s diversity being …


In-Plane Shear Lag Of Bolted Connections, Lip H. Teh, Benoit P. Gilbert Aug 2012

In-Plane Shear Lag Of Bolted Connections, Lip H. Teh, Benoit P. Gilbert

CCFSS Proceedings of International Specialty Conference on Cold-Formed Steel Structures (1971 - 2018)

This paper points out that the shear lag factors embedded in the design equations specified in the North American, European and Australasian cold-formed steel structures codes for determining the net section tension capacity of bolted connections in flat steel sheets either yield “anomalous” results or become irrelevant when they exceed unity. The anomaly is demonstrated through laboratory tests and is explained using simple calculus. A proper mathematical expression for the in-plane shear lag factor, which does not suffer from the anomaly of the code equations and never implies shear lag factors greater than unity for any configuration, is presented and …


Top Arc Seam Weld Shear Strength And Stiffness For Sheet-To-Sheet Connections, R. Nunna, J. Martin, J. Mattingly, P. Bodwell, D. Boltz, K. Cullum, Roger A. Laboube Aug 2012

Top Arc Seam Weld Shear Strength And Stiffness For Sheet-To-Sheet Connections, R. Nunna, J. Martin, J. Mattingly, P. Bodwell, D. Boltz, K. Cullum, Roger A. Laboube

CCFSS Proceedings of International Specialty Conference on Cold-Formed Steel Structures (1971 - 2018)

The North American Specification for the Design of Cold-Formed Steel Structural Members does not provide specific design guidance for sheet-to-sheet top arc seam welds in shear. A collaborative industry study has developed design guidance for both strength and stiffness of the connection to facilitate analytical evaluation of floor and roof diaphragm assemblies and wall assemblies. The test program was performed per AISI S905 and addressed material ductility, weld length, sheet thickness and the distribution of the force being transferred by the weld connection.


Effects Of Cold-Formed Steel Framed Gypsum Partition Walls On The Seismic Response Of A Medical Facility, Ryan Davies, Rodrigo Retamales, Gilberto Mosqueda, Andre Filiatrault, Don Allen Aug 2012

Effects Of Cold-Formed Steel Framed Gypsum Partition Walls On The Seismic Response Of A Medical Facility, Ryan Davies, Rodrigo Retamales, Gilberto Mosqueda, Andre Filiatrault, Don Allen

CCFSS Proceedings of International Specialty Conference on Cold-Formed Steel Structures (1971 - 2018)

The first experimental phase of the NEES Nonstructural Grand Challenge Project: “Simulation of the Seismic Performance of Nonstructural Systems” investigated the in-plane hysteretic behaviors of thirty-six full-scale cold-formed steel framed gypsum partition walls. Results of quasi-static reverse cyclic and dynamic testing on sixteen wall configurations including walls with commercial and institutional construction details and innovative connection techniques are first briefly reviewed. Thereafter, six tri-linear hysteretic models of partition walls with pinching behavior and strength and stiffness degradation are developed based on the experimental data for use in a finite element analysis platform. The partition wall models, represented by shear spring …


Characterizaiton Of Cold-Formed Steel Shear Wall Behavior Under Cyclic Loading For The Cfs-Nees Building, P. Liu, K. D. Peterman, C. Yu, B. W. Schafer Aug 2012

Characterizaiton Of Cold-Formed Steel Shear Wall Behavior Under Cyclic Loading For The Cfs-Nees Building, P. Liu, K. D. Peterman, C. Yu, B. W. Schafer

CCFSS Proceedings of International Specialty Conference on Cold-Formed Steel Structures (1971 - 2018)

The objective of this paper is to provide a full hysteretic characterization of OSB sheathed cold-formed steel (CFS) shear walls designed for use in the National Science Foundation funded Network for Earthquake Engineering Simulation (NEES) project: CFS-NEES (www.ce.jhu.edu/cfsnees). The shear walls were designed for a two-story ledger-framed building (i.e., the CFS-NEES building) that will undergo full-scale shake table testing at the University of Buffalo NEES site. Shear walls in real construction, such as the CFS-NEES building, have details that differ from the shear walls tested and provided for strength prediction in standards such as AISI-S213-07. Differences include: (a) ledger (rim …


Design Capacity Determination Assisted By Testing Based On Lrfd Method, Y. Q. Li, L. P. Wang, Z. Y. Shen Aug 2012

Design Capacity Determination Assisted By Testing Based On Lrfd Method, Y. Q. Li, L. P. Wang, Z. Y. Shen

CCFSS Proceedings of International Specialty Conference on Cold-Formed Steel Structures (1971 - 2018)

In some special circumstances of structural design, adequate calculation models are not available in current specifications or they cannot be used directly for new materials or structural configurations. In these cases, tests of the prototype units may be accepted as an alternative to calculation. If this alternative procedure is adopted, corresponding requirements and evaluation of test results should apply. In this paper, a complete procedure of determining the design capacity of the test specimens based on statistical analysis and Load and resistance factor design (LRFD) method was presented: characteristic value of experimental resistance was obtained from the minimum value of …


Critical Elastic Shear Buckling Stress Hand Solution For C- And Z-Sections Including Cross-Section Connectivity, Kevin Aswegan, Cristopher D. Moen Aug 2012

Critical Elastic Shear Buckling Stress Hand Solution For C- And Z-Sections Including Cross-Section Connectivity, Kevin Aswegan, Cristopher D. Moen

CCFSS Proceedings of International Specialty Conference on Cold-Formed Steel Structures (1971 - 2018)

This paper presents an approximate solution for the critical elastic buckling stress of cold-formed steel C- and Z-section members including cross-section connectivity. The elastic buckling solution is developed to support the extension of the Direct Strength Method to the shear ultimate limit state, where the cross sectional critical elastic shear buckling stress (load) is employed to predict shear capacity. The shear buckling stress and buckled half-wavelength are calculated with a classical energy solution for a thin plate with edges rotationally restrained. Rotational stiffness expressions in the AISI S100-07 specification, originally derived for distortional buckling of C- and Z-sections, are used …


Load Distribution In Floor To Wall Connections, D. M. Fox, D. R. Knill, R. M. Schuster Aug 2012

Load Distribution In Floor To Wall Connections, D. M. Fox, D. R. Knill, R. M. Schuster

CCFSS Proceedings of International Specialty Conference on Cold-Formed Steel Structures (1971 - 2018)

Presented in this paper is a cold formed steel load distribution system developed by iSPAN Systems LP that enables the installation of floor joists without the need to align them with the supporting wall studs. The floor joists are supported by a shear connection attached to a cold formed steel perimeter distribution member. In addition to the load distribution aspect, the system results in a simplified lateral design approach. An experimental verification study was carried out to establish the load distribution capability of the system, resulting in a simplified procedure to determine the connection requirements and load transfer characteristics to …


Improved Protocols For Automated Wheelpath Crack Detection In Pavements, Daniel Patrick Byram Aug 2012

Improved Protocols For Automated Wheelpath Crack Detection In Pavements, Daniel Patrick Byram

Graduate Theses and Dissertations

Roadway pavement distress evaluations are vital to understanding the mechanics of pavement stability, determining the distribution of rehabilitation costs, and knowing the appropriate rehabilitation strategies. Advancements in technology over the past two decades have changed the way these surveys have been performed by means of automated data collection and interpretation. More and more state agencies have invested in automated road analyzing vehicles that are able to collect high resolution images of the pavement. Fewer have adopted automated data processing software with the ability to interpret road distresses due to the common discrepancies in distress classification algorithms.

In addition to automated …


Laboratory Performance Of Highway Bridge Girder Anchorages Under Simulated Hurricane-Induced Wave Loading, Jora Lehrman, Christopher Higgins, Daniel Cox Jul 2012

Laboratory Performance Of Highway Bridge Girder Anchorages Under Simulated Hurricane-Induced Wave Loading, Jora Lehrman, Christopher Higgins, Daniel Cox

TREC Final Reports

Many bridges along the Gulf Coast of the United States were damaged by recent hurricanes, and many more are susceptible to similar damage. This research examines the structural performance of common connection details used to anchor prestressed concrete girders to the substructure. Full-scale specimens were fabricated and tested under static and dynamic cyclic load histories. Dynamic load histories were developed from previously conducted hydraulic tests of a 1/5 scale model of a highway bridge under hurricane wave loads. The load effects considered included the pseudo-statically applied vertical uplift force, horizontal force, combined horizontal and vertical forces, and dynamically applied combined …


Development Of System Reliability Models For Railway Bridges, Anna Maria Rakoczy Jul 2012

Development Of System Reliability Models For Railway Bridges, Anna Maria Rakoczy

Department of Civil and Environmental Engineering: Dissertations, Theses, and Student Research

Performance of the railway transportation network depends on the reliability of railway bridges, which can be affected by various forms of deterioration and extreme environmental conditions. More than half of the railway bridges in US were built before 1950 and many show signs of distress. There is a need for efficient methods to evaluate the safety reserve in the railway bridges by identification of the most sensitive parts of the bridge.

An accurate estimation of remaining fatigue life of a structural component is very important in prioritizing bridge rehabilitation and replacement. However, existing procedures to evaluate the fatigue behavior of …


Concrete Surface With Nano-Particle Additives For Improved Wearing Resistance To Increase Truck Traffic, Genda Chen, Dongming Yan, Chenglin Wu, Zhibin Lin, Nicholas Leventis, Shruti Mahadik-Khanolkar Jul 2012

Concrete Surface With Nano-Particle Additives For Improved Wearing Resistance To Increase Truck Traffic, Genda Chen, Dongming Yan, Chenglin Wu, Zhibin Lin, Nicholas Leventis, Shruti Mahadik-Khanolkar

Civil, Architectural and Environmental Engineering Faculty Research & Creative Works

This study focused on the use of nanotechnology in concrete to improve the wearing resistance of concrete. The nano materials used were polymer cross-linked aerogels, carbon nanotubes, and nano-SiO2, nano-CaCO3, and nano-Al2O3 particles. As an indirect measurement of the concrete wearing resistance, the tensile and compressive properties and the permeability of concrete were evaluated for various mix designs. The optimal amount of nano material additives were determined following the American Society of Testing Methods (ASTM) standard test methodologies. The test results from the materials were compared for their mechanical behaviors. This type of …


Initial Study And Verification Of A Distributed Fiber Optic Corrosion Monitoring System For Transportation Structures, Hai Xiao, Genda Chen, Zhan Gao, Ying Huang, Fujian Tang Jul 2012

Initial Study And Verification Of A Distributed Fiber Optic Corrosion Monitoring System For Transportation Structures, Hai Xiao, Genda Chen, Zhan Gao, Ying Huang, Fujian Tang

Electrical and Computer Engineering Faculty Research & Creative Works

For this study, a novel optical fiber sensing system was developed and tested for the monitoring of corrosion in transportation systems. The optical fiber sensing system consists of a reference long period fiber gratings (LPFG) sensor for corrosive environmental monitoring and a LPFG sensor coated with a thin film of nano iron and silica particles for steel corrosion monitoring. The environmental effects (such as pH and temperature) are compensated by the use of the reference LPFG sensor. The sensor design, simulation, and experimental validation were performed in this study to investigate the feasibility of the proposed sensing system for corrosion …


Conference Proceedings, Blake Tullis, Robert Jansson Jun 2012

Conference Proceedings, Blake Tullis, Robert Jansson

International Junior Researcher and Engineer Workshop on Hydraulic Structures

No abstract provided.