Open Access. Powered by Scholars. Published by Universities.®

Polymer Science Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 4 of 4

Full-Text Articles in Polymer Science

Influence Of Fused Deposition Modeling Process Parameters On The Constitutive Model Of Hyperelastic Thermoplastic Polyurethane, Lucas Gallup, Mohamed Trabia, Brendan O'Toole, Youssef Fahmy Dec 2024

Influence Of Fused Deposition Modeling Process Parameters On The Constitutive Model Of Hyperelastic Thermoplastic Polyurethane, Lucas Gallup, Mohamed Trabia, Brendan O'Toole, Youssef Fahmy

Mechanical Engineering Faculty Research

Thermoplastic polyurethanes (TPUs) are suited for fused deposition modeling (FDM) of parts that require high levels of flexibility and strength. Predicting the deformation of TPU parts produced using FDM may be difficult, especially under large deformations, as their constitutive models depend on the printing process parameters. The lack of understanding led to the absence of constitutive models for TPU parts produced using FDM. This work aims to identify accurate hyperelastic constitutive models. Six groups of uniaxial tensile specimens were produced using FDM. These groups were made with variations in two process parameters, which were infill geometry and extrusion nozzle temperature. …


Phosphine Oxide Containing Poly(Pyridinium Salt)S As Fire Retardant Materials, Maksudul M. Alam, Bidyut Biswas, Alexi K. Nedeltchev, Haesook Han, Asanga D. Ranasinghe, Pradip K. Bhowmik, Kisholoy Goswami Jul 2019

Phosphine Oxide Containing Poly(Pyridinium Salt)S As Fire Retardant Materials, Maksudul M. Alam, Bidyut Biswas, Alexi K. Nedeltchev, Haesook Han, Asanga D. Ranasinghe, Pradip K. Bhowmik, Kisholoy Goswami

Chemistry and Biochemistry Faculty Research

Six new rugged, high-temperature tolerant phosphine oxide-containing poly(4,4′-(p-phenylene)-bis(2,6-diphenylpyridinium)) polymers P-1, P-2, P-3, P-4, P-5, and P-6 are synthesized, characterized, and evaluated. Synthesis results in high yield and purity, as confirmed by elemental, proton (1H), and carbon 13 (13C) nuclear magnetic resonance (NMR) spectra analyses ... See full text for complete abstract.


Non-Einstein Viscosity Phenomenon Of Acrylonitrile–Butadiene–Styrene Composites Containing Lignin–Polycaprolactone Particulates Highly Dispersed By High-Shear Stress, Sing-Hoon Kim, Kisuk Choi, Kyouk Ryeol Choi, Taesung Kim, Jonghwan Suhr, Kwang Jin Kim, Hyoung Jin Choi, Jae-Do Nam Jun 2019

Non-Einstein Viscosity Phenomenon Of Acrylonitrile–Butadiene–Styrene Composites Containing Lignin–Polycaprolactone Particulates Highly Dispersed By High-Shear Stress, Sing-Hoon Kim, Kisuk Choi, Kyouk Ryeol Choi, Taesung Kim, Jonghwan Suhr, Kwang Jin Kim, Hyoung Jin Choi, Jae-Do Nam

Mechanical Engineering Faculty Research

Lignin powder was modified via ring-opening polymerization of caprolactone to form a lignin–polycaprolactone (LPCL) particulate. The LPCL particulates were mixed with an acrylonitrile–butadiene–styrene (ABS) matrix at an extremely high rotational speed of up to 3000 rpm, which was achieved by a closed-loop screw mixer and in-line melt extruder. Using this high-shear extruding mixer, the LPCL particulate size was controlled in the range of 3395 nm (conventional twin-screw extrusion) down to 638 nm (high-shear mixer of 3000 rpm) by altering the mixing speed and time. The resulting LPCL/ABS composites clearly showed non-Einstein viscosity phenomena, exhibiting reduced viscosity (2130 Pa·s) compared to …


Applied Analysis Of Ionic Polymer Metal-Composite Actuators, Siul Ruiz, Benjamin Mead, Woosoon Yim Apr 2013

Applied Analysis Of Ionic Polymer Metal-Composite Actuators, Siul Ruiz, Benjamin Mead, Woosoon Yim

College of Engineering: Graduate Celebration Programs

  • IPMC is a type of smart material called an electroactive polymer
  • Consists of an ionic polymer such as Nafion or Flemion and a conducive metal such as platinum or gold
  • COMSOL multi-physics simulations accurately model the experimental displacement results
  • Optimization performed using the multi-physics model to find the maximum deflection, force, and twisting
  • Using the closed loop control system accurate IPMC tip location can be achieved
  • This control system has been extended to function using a computer mouse as an input