Open Access. Powered by Scholars. Published by Universities.®

California Polytechnic State University, San Luis Obispo

Discipline
Keyword
Publication Year
Publication

Articles 1 - 23 of 23

Full-Text Articles in Systems and Integrative Engineering

Pet Mobility Project, John Shelby, Lily-Rose Jolie Bacon, Andrea Yasmine Reyes Jun 2026

Pet Mobility Project, John Shelby, Lily-Rose Jolie Bacon, Andrea Yasmine Reyes

Biomedical Engineering

The Pet Mobility Project, sponsored by Terri Smith and Jasper Jackson, is an initiative aimed at providing a custom mobility aid to a pet in the San Luis Obispo community. Amber Rappozo’s young German Shepherd, LeDoux, was selected as the project’s recipient. LeDoux suffers from hindleg weakness and, as a result, has limited mobility. This document provides a comprehensive overview of the Pet Mobility Project, detailing the motivation, background, and design approach behind the development of a LeDoux’s custom mobility aid.


Cardiac Twitch Force Measurement System, Tara Hoffman, Sebastian Carrascal Gómez, Julian Macdonald Jun 2026

Cardiac Twitch Force Measurement System, Tara Hoffman, Sebastian Carrascal Gómez, Julian Macdonald

Biomedical Engineering

The goal of this project is to develop a low-cost and accurate force measurement system and method of measurement to be used in the testing of grown cardiac tissue samples. The primary stakeholder in this project is Dr. Luke Perreault, a biomedical engineering professor at California Polytechnic State University San Luis Obispo who is studying grown cardiac tissue rings, and any of his student lab personnel. Other stakeholders include other researchers in the tissue engineering field who require a similar form of testing to the methods developed in this project.

This document will introduce the identified problem and background as …


Characteristic Stress And Strain Optimization Of Cardiovascular Catheters With Laser-Cut Hypotubes Using Finite Element Analysis, Kyle E. Hirth Jun 2026

Characteristic Stress And Strain Optimization Of Cardiovascular Catheters With Laser-Cut Hypotubes Using Finite Element Analysis, Kyle E. Hirth

Master's Theses

Cardiovascular catheter systems rely on laser-cut hypotubes to balance flexibility and structural integrity required for minimally invasive surgical procedures.  Optimizing these mechanical characteristics remains a significant challenge.  This study aims to investigate the influence of key laser-cut geometric parameters on the mechanical performance of hypotubes through finite element analysis.

Commercially representative laser-cut hypotubes were modeled and a finite element model was developed.   Geometric design parameters were varied across a design space consisting of pitch values ranging from 0.006 in. to 0.018 in. and cuts per revolution (CPR) ranging from 2.5 – 4.5.  For each pitch and CPR combination, loading stiffness …


Fully Integrated Slippage Detection System For Lower Limb Amputees, Christopher E. Miglio Dec 2025

Fully Integrated Slippage Detection System For Lower Limb Amputees, Christopher E. Miglio

Master's Theses

Lower limb amputees face significant challenges in maintaining a proper prosthetic fit, as improper fit can lead to slippage at the limb-socket interface, resulting in discomfort, pressure sores, and long-term musculoskeletal complications. To address this issue, a fully integrated slippage detection system was developed to monitor an amputee’s daily activities and slippage occurrences to understand their prosthetic fit over time. The system consists of a prosthetic sock embedded with Interlink 406 flexible piezoresistive force-sensing resistors (FSRs). The sock, worn directly on the residual limb, continuously measures pressure at the limb-socket interface. Sensor data from six FSRs is sampled at approximately …


Ray Collection: Forging A New Fashion Genre, Olivia R. Cooper Jun 2025

Ray Collection: Forging A New Fashion Genre, Olivia R. Cooper

Graphic Communication

This senior project addresses a gap in the fashion industry by creating a new genre through a unique collection and comprehensive branding. The "RAY" collection draws inspiration from the designer's artistic roots and is a deeply personal homage to influential female artists like Frida Kahlo, Louise Bourgeois, and Leonora Carrington, whose works have inspired the designer's creative journey. Each piece in the collection draws direct inspiration from these artists, reflecting the creator's vision and self-expression, a key element of the streetwear genre incorporated into the designs.

The project also heavily emphasizes fashion branding, encompassing a logo, brand identity, social and …


Hypoxic Incubator: Improving Robustness/Reliability And Demonstrating Physiological Efficacy, Damon Dennis Tan Nov 2024

Hypoxic Incubator: Improving Robustness/Reliability And Demonstrating Physiological Efficacy, Damon Dennis Tan

Master's Theses

The Microphysiological Systems Laboratory aims to develop colorectal cancer tumor models under a hypoxic environment to assess model response to pharmaceutical compounds in vitro. To perform relevant studies, researchers have attempted to use different hypoxic inducing strategies such as a nitrogen pod and hypoxic incubator to recreate in vivo physiological responses to hypoxia. However, studies would be interrupted due to incubator functionality failure. To ensure successful and physiologically relevant studies, I improved and verified the robustness and reliability of a hypoxic incubator previously designed and manufactured in the lab. Through the testing and iterating design processes, I engineered and implemented …


3d Printed Microfluidic Fabrication Methodology, Characterization, Mechanical Design, And Applications In Electrostatic Artificial Muscles And Benthic Microbial Fuel Cells, Terak B. Hornik Nov 2024

3d Printed Microfluidic Fabrication Methodology, Characterization, Mechanical Design, And Applications In Electrostatic Artificial Muscles And Benthic Microbial Fuel Cells, Terak B. Hornik

Master's Theses

The fabrication of microfluidic devices often requires specialized methods. The development of these methods requires careful characterization and understanding of the processes involved. Using primarily PolyJet 3D printing technology, microfluidics offers a wide scope of applications such as microfluidic benthic microbial fuel cells (MBMFCs) and electrostatic artificial muscles. MBMFCs benefit from the confinement of the microbes resulting in close proximity between the electrode and the organisms. Using a modular design called the Sponge, assembly and upscaling is possible. Electrostatic artificial muscles benefit from a microfluidic approach due to the non-linearity of electrostatic attraction creating disproportionate benefits when miniaturized. When designed …


Hypoxic Incubation Chamber, Simone Lisette Helfrich, Makenzie Nicole Jones Nov 2022

Hypoxic Incubation Chamber, Simone Lisette Helfrich, Makenzie Nicole Jones

Biomedical Engineering: Graduate Reports and Projects

This paper describes the design, manufacturing, and testing of a novel controllable hypoxic incubator with fully functional oxygen gas control and temperature control in a humid environment. On the current market, a majority of the few hypoxic incubators use pre-mixed gas that does not offer precise control over gas concentration. The objective for this project was to create a chamber that allows the user to set the O2 concentration to varying set points of % O2 while maintaining the chamber at a constant body temperature, CO2 level, humidity, and sterility. To start the project, multiple concepts were developed for the …


Hypoxic Incubation Chamber, Simone Lisette Helfrich, Makenzie Nicole Jones Nov 2022

Hypoxic Incubation Chamber, Simone Lisette Helfrich, Makenzie Nicole Jones

Master's Theses

This paper describes the design, manufacturing, and testing of a novel controllable hypoxic incubator with fully functional oxygen gas control and temperature control in a humid environment. On the current market, a majority of the few hypoxic incubators use pre-mixed gas that does not offer precise control over gas concentration. The objective for this project was to create a chamber that allows the user to set the O2 concentration to varying set points of % O2 while maintaining the chamber at a constant body temperature, CO2 level, humidity, and sterility. To start the project, multiple concepts were developed for the …


Insole Fall Prevention Device, Nick M. Hughes, Andrew M. Slaboda May 2022

Insole Fall Prevention Device, Nick M. Hughes, Andrew M. Slaboda

Biomedical Engineering

Falls among the aging population occur every single day, with 1 in every 5 resulting in some injury and 300,000 hospitalized every year with a hip fracture [1]. The most popular and effective way to mitigate these falls is through physical therapist intervention. However, with the increased popularity in telerehab, many patients at risk for falls cannot accurately convey their gait tendencies to their physical therapists from the comfort of their home or while not in direct contact with the PT. A device like an insole, implanted with force sensors, which measures different parts of a patient’s foot, could convey …


Astm Test Fixture For Spinal Screws, Sarah K. Pickering, Matthew W. Rowen, Kaajal N. Khanna, Thomas A. Sunding Mar 2022

Astm Test Fixture For Spinal Screws, Sarah K. Pickering, Matthew W. Rowen, Kaajal N. Khanna, Thomas A. Sunding

Biomedical Engineering

This document is an overview report of the Cal Poly Senior Project ASTM Test Fixture for SeaSpine orthopedic bone screws. The main application of orthopedic screws is to fasten implants directly to the bone structure, enhancing structural integrity. Testing for breaking angle, insertion torque, removal torque, axial pullout strength, and self-tapping force as specified in the ASTM F543 Annexes provides the FDA with vital screw mechanics and ensures manufacturing uniformity. The test system is comprised of custom and off the shelf components allowing for interchangeability, in case of part failure, and a low overall cost. It is mechanically capable of …


Microfluidic Electrical Impedance Spectroscopy System Automation And Characterization, Keaton Frahmann Jun 2021

Microfluidic Electrical Impedance Spectroscopy System Automation And Characterization, Keaton Frahmann

Master's Theses

In this work, a novel microfluidic cell culture platform capable of automated electrical impedance measurements and immunofluorescence and brightfield microscopy was developed for further in-vitro cellular research intended to optimize cell culture conditions. The microfluidic system design, fabrication, automation, and design verification testing are described. Electrical and optical measurements of the 16 parallel cell culture chambers were automated via a custom LabView interface. A proposed design change will enable gas diffusion, removing the need for an environmental enclosure and allow long-term cell culture experiments. This "lab on a chip" system miniaturizes and automates experiments improving testing throughput and accuracy while …


Portable Ventilator, Bradley C. Weeks, Jack W. Brewer, Sanders Sanabria Jun 2021

Portable Ventilator, Bradley C. Weeks, Jack W. Brewer, Sanders Sanabria

Electrical Engineering

The current COVID-19 pandemic has heavily impacted the healthcare system in the United States and elsewhere. The need for patients to have access to a hospital with a ventilator along with a shortage of ventilators for recovery and at-home care as a result of minimal hospital vacancy for patients has been greatly stressed. The presented problem is both an unmet demand and supply of portable and effective ventilators. Existing ventilators have many shortcomings that should be addressed: size, weight, cost, and complexity of current ventilators confines users to stay in a medical facility whilst being monitored by professionals. This both …


The Tierni Resistance Training System, Michael J. Hansen, Abigail M. Youngblood, Gabriel M. Johnson Mar 2021

The Tierni Resistance Training System, Michael J. Hansen, Abigail M. Youngblood, Gabriel M. Johnson

Biomedical Engineering

The purpose of the Tierni Resistance Training System project was to design and construct functional workout apparel that has built-in resistance. For this product, the key customer requirements we set out to address were most importantly material comfort and functionality, followed by stylishness, lack of latex, safety for injured and uninjured users, and washer safety. To meet these customer requirements, we started by researching current resistance training technology, and used the findings as a springboard for our own design development. After initial brainstorming, engineering specifications were generated based on the customer requirements. These specifications revolved around the thermal insulation, pressure, …


Integrity Testing Of Gas Permeable Silicone Filters, Maggie M. Baker, Thomas P. Humann, Kevin J. Yerina Mar 2020

Integrity Testing Of Gas Permeable Silicone Filters, Maggie M. Baker, Thomas P. Humann, Kevin J. Yerina

Biomedical Engineering

This report investigates the most reasonable, cost efficient, and reliable ways to integrity test a filter made from a permeable silicone membrane for future biomedical and pharmaceutical applications. The goal of the project was to create a fixture that a pharmaceutical company can use to quickly and reliably test the integrity of the filter. A variety of methods are outlined to test the integrity of the filter, after a series of quantitative tests, a single method was established that meet the requirements most thoroughly. The method that was determined to be most effective involves a series of components including a …


Pressure Cylinder Controlled Release Valve, Alexa Dominique Balbuena Mar 2019

Pressure Cylinder Controlled Release Valve, Alexa Dominique Balbuena

Biomedical Engineering

This project aims to integrate an automatic gas release system in a pre-existing scaffold fabrication process for tissue engineering applications.

To form the proper scaffold structure, the fabrication process is heavily influenced by the change in its surrounding pressure. The current production involves a pressure transducer and electric valve that is managed manually to create a suitable pressure environment for the scaffold. This method, although functional, proves to be ineffective when creating several batches; the user needs to constantly monitor the developing pressure profile and alter voltage parameters accordingly to create a linear gas release under a predetermined slope.

To …


Quantifying Parkinson's Disease Symptoms Using Mobile Devices, Charles R. Aylward Dec 2016

Quantifying Parkinson's Disease Symptoms Using Mobile Devices, Charles R. Aylward

Master's Theses

Current assessments for evaluating the progression of Parkinson’s Disease are largely qualitative and based on small sets of data obtained from occasional doctor-patient interactions. There is a clinical need to improve the techniques used for mitigating common Parkinson’s Disease symptoms. Available data sets for researching the disease are minimal, hindering advancement toward understanding the underlying causes and effectiveness of treatment and therapies. Mobile devices present an opportunity to continuously monitor Parkinson’s Disease patients and collect important information regarding the severity of symptoms. The evolution of digital technology has opened doors for clinical research to extend beyond the clinic by incorporating …


Design Of A Non-Contact Home Monitoring System For Audio Detection Of Infant Apnea, Daniel T. White Aug 2015

Design Of A Non-Contact Home Monitoring System For Audio Detection Of Infant Apnea, Daniel T. White

Master's Theses

Infant apnea is a widespread condition in which infants fail to effectively breathe, and can lead to death. Clinical solutions exist for continuous monitoring of respirations in a hospital setting and requiring constant skin contact. This thesis investigates the construction of a proof of concept device that performs in-home monitoring without skin contact and with commonly available off-the-shelf components.

The device constructed used a directional microphone to detect breathing sounds, an omnidirectional microphone to detect ambient noise as a baseline to help isolate the breathing sounds, and LabVIEW software deployed on an inexpensive laptop computer to quantify incidents of apparent …


Design, Characterization And Application Of A Multiple Input Stethoscope Apparatus, Spencer Geng Wong Aug 2014

Design, Characterization And Application Of A Multiple Input Stethoscope Apparatus, Spencer Geng Wong

Master's Theses

For this project, the design, implementation, characterization, calibration and possible applications of a multiple transducer stethoscope apparatus were investigated. The multi-transducer sensor array design consists of five standard stethoscope diaphragms mounted to a rigid frame for a-priori knowledge of their relative spatial locations in the x-y plane, with compliant z-direction positioning to ensure good contact and pressure against the subject’s skin for reliable acoustic coupling. When this apparatus is properly placed on the body, it can digitally capture the same important body sounds investigated with standard acoustic stethoscopes; especially heart sounds. Acoustic signal inputs from each diaphragm are converted to …


Alternate Computer Input Device For Individuals With Quadriplegia, Tobais Elder, Michelle Martinez, David Sylvester Jun 2014

Alternate Computer Input Device For Individuals With Quadriplegia, Tobais Elder, Michelle Martinez, David Sylvester

Biomedical Engineering

This project details the design development of an alternative computer input system that allows a person with quadriplegia to move a computer's cursor and activate left and right click button inputs. After researching and analyzing possible solutions, an end design was chosen that most appropriately satisfied all user requirements and engineering specifications. This final design employs a head mounted Inertial Measurement Unit (IMU) with 9 DoF (Degrees of Freedom) to track head movements and correlate these motions to computer cursor movements. A Sip-Puff Transducer monitors and interprets a user's application of negative and positive air pressure differentials to a vinyl …


Guidance System, Kayaking For The Visually Impaired, D. Ryan Kirtland, Ryan Phife, William Gardner, Amy Johnson Jun 2013

Guidance System, Kayaking For The Visually Impaired, D. Ryan Kirtland, Ryan Phife, William Gardner, Amy Johnson

Biomedical Engineering

Quality Life Plus is working with Team River Runner to develop an assistive guidance system for veterans who want to remain active by kayaking, after sustaining an injury that impairs vision. This system allows these veterans to complete a slalom speed race independent of a personal guide in the water. The system incorporates 3 stations that each contain a speaker connected to a microcontroller system covered by a Pelican Case on a custom made buoy. During the slalom race, a kayaker will travel from shore towards buoy #1 as it omits sound from the speaker. As the kayaker moves around …


An Inexpensive Method For Creating Paste To Be Used In Paper-Based Microfluidic Devices, Kirra Marie Sankey Jun 2011

An Inexpensive Method For Creating Paste To Be Used In Paper-Based Microfluidic Devices, Kirra Marie Sankey

Biomedical Engineering

Microfluidic devices are diagnostic tools that are small, portable, and inexpensive. This makes them ideally suited for resource-limited settings. To construct a 3D device, each layer of patterned paper is stacked using double-sided tape with holes corresponding to the pattern. It is necessary to have a paste to fill the holes in the tape and provide a medium for the fluid to wick through. The powder used to make the paste is very expensive and must be bought in bulk (an estimated $1121 - $1231), so it is not convenient for the Biomedical (BMED) department to use. This project was …


Integration Of Microfluidics With Surface Plasmon Resonance, Scott B. Fratzke Aug 2010

Integration Of Microfluidics With Surface Plasmon Resonance, Scott B. Fratzke

Master's Theses

This thesis successfully integrates laminate microfluidic devices with an analytic Surface Plasmon Resonance (SPR) instrument. Integration was accomplished at low-cost using materials such as polydimethylsiloxane (PDMS), Poly(methyl methacrylate) (PMMA), Tygon tubing, and a 3-way stopcock. The main components of this thesis are the design and fabrication of the low-cost, in-house fluidics that can integrate with upstream microfluidics and the validation of the in-house fluidics using the Biosensing Instruments BI-2000 SPR instrument. The low-cost fluidics was designed and fabricated “in-house” using a novel investment casting technique that required the use of laser cutting technology to make a master cast, and candle …