Open Access. Powered by Scholars. Published by Universities.®
Systems and Integrative Engineering Commons™
Open Access. Powered by Scholars. Published by Universities.®
- Institution
- Keyword
-
- 3D-Printing (2)
- Biomechanics (2)
- Hypoxia (2)
- 2D Estimator (1)
- 3T3 (1)
-
- ASTM F543 (1)
- Acoustic Pressure Calibration (1)
- Actuator (1)
- Allergy (1)
- Anaphylaxis (1)
- And five-bar mechanism (1)
- Arrayed sensor (1)
- Assistance (1)
- Assistive technology (1)
- Auto-injector (1)
- Automation (1)
- BOLD fMRI (1)
- Bacteria identification (1)
- Benthic microbial fuel cell (1)
- Bicuspid valve (1)
- Bio-Medical Engineering (1)
- Bioengineering and Biomedical Engineering (1)
- Biofouling (1)
- Biomedical engineering (1)
- Blind (1)
- Bone Screws (1)
- C-Arm (1)
- CONTROL SYSTEM (1)
- Cancer (1)
- Capsule pump (1)
- Publication Year
- Publication
-
- Master's Theses (4)
- Biomedical Engineering (2)
- Dissertations and Theses (2)
- Mechanical Engineering Theses (2)
- The Summer Undergraduate Research Fellowship (SURF) Symposium (2)
-
- Theses and Dissertations (2)
- Theses and Dissertations--Mechanical and Aerospace Engineering (2)
- Biomedical Engineering: Graduate Reports and Projects (1)
- College of Graduate Studies: Theses & Dissertations (1)
- Libraries' Newsletters (1)
- Masters Theses (1)
- Multidisciplinary Studies Theses and Dissertations (1)
- Purdue Journal of Service-Learning and International Engagement (1)
- Student Works (2020-2029) (1)
- Publication Type
Articles 1 - 23 of 23
Full-Text Articles in Systems and Integrative Engineering
Characteristic Stress And Strain Optimization Of Cardiovascular Catheters With Laser-Cut Hypotubes Using Finite Element Analysis, Kyle E. Hirth
Characteristic Stress And Strain Optimization Of Cardiovascular Catheters With Laser-Cut Hypotubes Using Finite Element Analysis, Kyle E. Hirth
Master's Theses
Cardiovascular catheter systems rely on laser-cut hypotubes to balance flexibility and structural integrity required for minimally invasive surgical procedures. Optimizing these mechanical characteristics remains a significant challenge. This study aims to investigate the influence of key laser-cut geometric parameters on the mechanical performance of hypotubes through finite element analysis.
Commercially representative laser-cut hypotubes were modeled and a finite element model was developed. Geometric design parameters were varied across a design space consisting of pitch values ranging from 0.006 in. to 0.018 in. and cuts per revolution (CPR) ranging from 2.5 – 4.5. For each pitch and CPR combination, loading stiffness …
Simplified Molecular Diagnostics Methods For Environmental Testing Of Pathogens And Other Applications, Mohammad Dehghan Banadaki
Simplified Molecular Diagnostics Methods For Environmental Testing Of Pathogens And Other Applications, Mohammad Dehghan Banadaki
Theses and Dissertations--Mechanical and Aerospace Engineering
Environmental Surveillance (ES) has emerged as a powerful tool to monitor the emergence and persistence of a pathogen within a facility or community using wastewater/water analysis. Over the past four years, implementation of ES has experienced an explosive acceleration, driven by efforts to monitor the spread of SARS-CoV-2, which has made ES a routinely used public health tool in many locations. We can now use ES to measure the emergence/presence/abundance of different viruses (e.g., SARS-CoV-2, influenza, mpox), bacteria (e.g., E. coli, V. cholerae, antibiotic-resistant strains), fungi (e.g., C. auris), and other biological markers indicative of infectious diseases. However, its broad …
Hypoxic Incubator: Improving Robustness/Reliability And Demonstrating Physiological Efficacy, Damon Dennis Tan
Hypoxic Incubator: Improving Robustness/Reliability And Demonstrating Physiological Efficacy, Damon Dennis Tan
Master's Theses
The Microphysiological Systems Laboratory aims to develop colorectal cancer tumor models under a hypoxic environment to assess model response to pharmaceutical compounds in vitro. To perform relevant studies, researchers have attempted to use different hypoxic inducing strategies such as a nitrogen pod and hypoxic incubator to recreate in vivo physiological responses to hypoxia. However, studies would be interrupted due to incubator functionality failure. To ensure successful and physiologically relevant studies, I improved and verified the robustness and reliability of a hypoxic incubator previously designed and manufactured in the lab. Through the testing and iterating design processes, I engineered and implemented …
3d Printed Microfluidic Fabrication Methodology, Characterization, Mechanical Design, And Applications In Electrostatic Artificial Muscles And Benthic Microbial Fuel Cells, Terak B. Hornik
Master's Theses
The fabrication of microfluidic devices often requires specialized methods. The development of these methods requires careful characterization and understanding of the processes involved. Using primarily PolyJet 3D printing technology, microfluidics offers a wide scope of applications such as microfluidic benthic microbial fuel cells (MBMFCs) and electrostatic artificial muscles. MBMFCs benefit from the confinement of the microbes resulting in close proximity between the electrode and the organisms. Using a modular design called the Sponge, assembly and upscaling is possible. Electrostatic artificial muscles benefit from a microfluidic approach due to the non-linearity of electrostatic attraction creating disproportionate benefits when miniaturized. When designed …
Shape Memory Alloy Capsule Micropump For Drug Delivery Applications, Youssef Mohamed Kotb
Shape Memory Alloy Capsule Micropump For Drug Delivery Applications, Youssef Mohamed Kotb
Theses and Dissertations
Implantable drug delivery devices have many benefits over traditional drug administration techniques and have attracted a lot of attention in recent years. By delivering the medication directly to the tissue, they enable the use of larger localized concentrations, enhancing the efficacy of the treatment. Passive-release drug delivery systems, one of the various ways to provide medication, are great inventions. However, they cannot dispense the medication on demand since they are nonprogrammable. Therefore, active actuators are more advantageous in delivery applications. Smart material actuators, however, have greatly increased in popularity for manufacturing wearable and implantable micropumps due to their high energy …
Redesign Of Robotic Walking Training Device To Involve Zero Gravity Capabilities And Daily Activities, Chad Ballard
Redesign Of Robotic Walking Training Device To Involve Zero Gravity Capabilities And Daily Activities, Chad Ballard
Mechanical Engineering Theses
Many patients struggle with disabilities that hinder their ability to walk. This project aimed to create a leg assembly capable of variable gravity so that it could be combined with a Robotic Walking Training Device, and lead to better rehabilitation options for patients. This was accomplished by deriving equations of joint torque, creating circuit diagrams for Arduino systems, modeling leg assemblies in CAD, and finally combining it to create a working small-scale prototype. The result of the prototype testing showed accurate movement on each joint, especially the ankle and knee segments, to create virtual zero gravity. In addition to this, …
Optimizing Transcranial Focused Ultrasound: Calibration, Neuro Navigation, And Bold Fmri Evidence Of Neuromodulation, Amilcar J. Malave
Optimizing Transcranial Focused Ultrasound: Calibration, Neuro Navigation, And Bold Fmri Evidence Of Neuromodulation, Amilcar J. Malave
Dissertations and Theses
This thesis presents the development, calibration, and initial implementation of transcranial focused ultrasound (tFUS) for neuromodulation in a human study. The primary objectives were to design a system capable of delivering precise and safe ultrasound stimulation to targeted brain regions and to conduct preliminary trials to assess its effects on brain activity. A custom calibration device was developed to ensure accurate measurement of acoustic pressure, addressing challenges such as voltage alterations caused by changes in system impedance. Additionally, a neuro-navigation tool was created to facilitate precise targeting of the right subgenual anterior cingulate cortex (right sgACC), enabling accurate placement of …
Enhancing Human Key Point Identification: A Comparative Study Of High-Resolution Vicon Dataset And Coco Dataset Using Bpnet, Bibash Lama
Masters Theses
Accurately identifying human key points is crucial for various applications, including activity recognition, pose estimation, and gait analysis. This study presents a high-resolution dataset created using the VICON motion capture system and three differently oriented 2D cameras, that can be used to train different neural networks for estimating the 2D key joint positions of the person from the 2D images or videos. The participants in the study included 25 healthy adults (17 males and 8 females) performing normal gait movements for about 2 to 3 seconds. The VICON system captured 3D ground truth data, while the three 2D cameras collected …
Design And Fabrication Of A Force-Displacement Control Mechanism For Bone-Surgical Tool Testing, Kenneth Nwagu
Design And Fabrication Of A Force-Displacement Control Mechanism For Bone-Surgical Tool Testing, Kenneth Nwagu
College of Graduate Studies: Theses & Dissertations
This project focuses on the design and fabrication of an experimental setup for orthopedic-tool testing, tailored for a surgical instrumentation company. The multifaceted project encompasses a literature review, conceptual design, prototyping, and rigorous testing, resulting in a versatile control system capable of assessing various orthopedic tools, including bone drills, saws, burrs, and power handpieces.
Orthopedic surgical procedures (which include cutting and/or drilling into bone) often need to be performed on bones for faster recovery. The drilling and cutting process can cause an increase in temperature at the cutting site which can cause bone necrosis. The tools also need to be …
Hypoxic Incubation Chamber, Simone Lisette Helfrich, Makenzie Nicole Jones
Hypoxic Incubation Chamber, Simone Lisette Helfrich, Makenzie Nicole Jones
Biomedical Engineering: Graduate Reports and Projects
This paper describes the design, manufacturing, and testing of a novel controllable hypoxic incubator with fully functional oxygen gas control and temperature control in a humid environment. On the current market, a majority of the few hypoxic incubators use pre-mixed gas that does not offer precise control over gas concentration. The objective for this project was to create a chamber that allows the user to set the O2 concentration to varying set points of % O2 while maintaining the chamber at a constant body temperature, CO2 level, humidity, and sterility. To start the project, multiple concepts were developed for the …
Hypoxic Incubation Chamber, Simone Lisette Helfrich, Makenzie Nicole Jones
Hypoxic Incubation Chamber, Simone Lisette Helfrich, Makenzie Nicole Jones
Master's Theses
This paper describes the design, manufacturing, and testing of a novel controllable hypoxic incubator with fully functional oxygen gas control and temperature control in a humid environment. On the current market, a majority of the few hypoxic incubators use pre-mixed gas that does not offer precise control over gas concentration. The objective for this project was to create a chamber that allows the user to set the O2 concentration to varying set points of % O2 while maintaining the chamber at a constant body temperature, CO2 level, humidity, and sterility. To start the project, multiple concepts were developed for the …
Astm Test Fixture For Spinal Screws, Sarah K. Pickering, Matthew W. Rowen, Kaajal N. Khanna, Thomas A. Sunding
Astm Test Fixture For Spinal Screws, Sarah K. Pickering, Matthew W. Rowen, Kaajal N. Khanna, Thomas A. Sunding
Biomedical Engineering
This document is an overview report of the Cal Poly Senior Project ASTM Test Fixture for SeaSpine orthopedic bone screws. The main application of orthopedic screws is to fasten implants directly to the bone structure, enhancing structural integrity. Testing for breaking angle, insertion torque, removal torque, axial pullout strength, and self-tapping force as specified in the ASTM F543 Annexes provides the FDA with vital screw mechanics and ensures manufacturing uniformity. The test system is comprised of custom and off the shelf components allowing for interchangeability, in case of part failure, and a low overall cost. It is mechanically capable of …
Creating Reel Designs: Reflecting On Arthrogryposis Multiplex Congenita In The Community, Iris Layadi
Creating Reel Designs: Reflecting On Arthrogryposis Multiplex Congenita In The Community, Iris Layadi
Purdue Journal of Service-Learning and International Engagement
Because of its extreme rarity, the genetic disease arthrogryposis multiplex congenita (AMC) and the needs of individuals with the diagnosis are often overlooked. AMC refers to the development of nonprogressive contractures in disparate areas of the body and is characterized by decreased flexibility in joints, muscle atrophy, and developmental delays. Colton Darst, a seven-year-old boy from Indianapolis, Indiana, was born with the disorder, and since then, he has undergone numerous surgical interventions and continues to receive orthopedic therapy to reduce his physical limitations. His parents, Michael and Amber Darst, have hopes for him to regain his limbic motion and are …
Development Of Light Actuated Chemical Delivery Platform On A 2-D Array Of Micropore Structure, Hojjat Rostami Azmand, Hojjat Rostami Azmand
Development Of Light Actuated Chemical Delivery Platform On A 2-D Array Of Micropore Structure, Hojjat Rostami Azmand, Hojjat Rostami Azmand
Dissertations and Theses
Localized chemical delivery plays an essential role in the fundamental information transfers within biological systems. Thus, the ability to mimic the natural chemical signal modulation would provide significant contributions to understand the functional signaling pathway of biological cells and develop new prosthetic devices for neurological disorders. In this paper, we demonstrate a light-controlled hydrogel platform that can be used for localized chemical delivery in a high spatial resolution. By utilizing the photothermal behavior of graphene-hydrogel composites confined within micron-sized fluidic channels, patterned light illumination creates the parallel and independent actuation of chemical release in a group of fluidic ports. The …
Nebulizer-Based Systems To Improve Pharmaceutical Aerosol Delivery To The Lungs, Benjamin M. Spence
Nebulizer-Based Systems To Improve Pharmaceutical Aerosol Delivery To The Lungs, Benjamin M. Spence
Theses and Dissertations
Combining vibrating mesh nebulizers with additional new technologies leads to substantial improvements in pharmaceutical aerosol delivery to the lungs across therapeutic administration methods. In this dissertation, streamlined components, aerosol administration synchronization, and/or Excipient Enhanced Growth (EEG) technologies were utilized to develop and test several novel devices and aerosol delivery systems. The first focus of this work was to improve the poor delivery efficiency, e.g., 3.6% of nominal dose (Dugernier et al. 2017), of aerosolized medication administration to adult human subjects concurrent with high flow nasal cannula (HFNC) therapy, a form of continuous-flow non-invasive ventilation (NIV). The developed Low-Volume Mixer-Heater (LVMH) …
Detection Of Nucleotides In Hydrated Ssdna Via 2-D H-Bn Nanopore With Ionic-Liquid/Salt-Water Interface, Jungsoo Lee
Detection Of Nucleotides In Hydrated Ssdna Via 2-D H-Bn Nanopore With Ionic-Liquid/Salt-Water Interface, Jungsoo Lee
Multidisciplinary Studies Theses and Dissertations
Accomplishing slow translocation speed with high sensitivity has been the greatest mission for solid-state nanopore (SSN) to electrically detect nucleobases in single-stranded DNA (ssDNA). In this study, a method to detect nucleobases in ssDNA using a SSN is introduced by considerably slowing down the translocation speed and effectively increasing its sensitivity. The ultra-thin titanium dioxide (TiO2) coated hexagonal boron nitride (h-BN) nanopore was fabricated, along with an ionic-liquid [bmim][PF6]/2.0 M KCl aqueous (cis/trans) interfacial system, to increase both the spatial and the temporal resolutions. As the ssDNA molecules entered the nanopore, a …
Biomechanical Investigation Of Individual With Over-Pronation And Over-Supination Foot During Walking, Ghani Nur Saibah
Biomechanical Investigation Of Individual With Over-Pronation And Over-Supination Foot During Walking, Ghani Nur Saibah
Student Works (2020-2029)
Over-pronation and over-supination foot conditions are foot deformity that can lead to unstable ankle and subtalar joint during walking. They are define as condition where the foot roll in and out excessively from its neutral line and can lead to misalignment of the foot and leg in human in which can create abnormal gait cycle. Therefore, the purposes of this study are to analyze the foot-ankle joint biomechanical behavior including the range of motion, joint moment, joint power and GRF in a complete gait cycle for all subjects in this study and to compare the foot-ankle biomechanical behavior between normal …
System Integration Of C-Arm Robotic Prototype Using Motion Capture Guidance For Accurate Repositioning, Alireza Yazdanshenas
System Integration Of C-Arm Robotic Prototype Using Motion Capture Guidance For Accurate Repositioning, Alireza Yazdanshenas
Mechanical Engineering Theses
One of the important surgical tools in spinal surgery is the C-Arm X-ray System. The C-Arm is a large “C” shaped and manually maneuvered arm that provides surgeons and X-ray technicians the ability to take quick quality X-rays during surgery. Because of its five degrees of freedom, the C-Arm can be manually maneuvered around the patient to provide many angles and perspectives, ensuring surgical success.
This system works fine for most surgical procedures but falls short when the C-Arm must be moved out of the way for complicated surgical procedures.
The aim of this thesis is to develop an accurate …
High-Throughput Nanoliter Dispensing Device For Biological Applications, Cole Reynolds, Euiwon Bae Dr., J Paul Robinson Dr.
High-Throughput Nanoliter Dispensing Device For Biological Applications, Cole Reynolds, Euiwon Bae Dr., J Paul Robinson Dr.
The Summer Undergraduate Research Fellowship (SURF) Symposium
Pathogen identification is a field that can contribute largely to the prevention of the spreading of illness and disease. In the past, pathogen identification has been a long and arduous process due to the time-consuming processes and steps that requires technician’s time and effort. With new technologies emerging however, screening of bacteria colonies can be done in a quick and high-throughput way. The problem is that using the current methods, bacteria cannot be transferred to petri dishes fast enough to keep up with the new screening methods. The current study focuses on exploring different methods to create an ergonomic device …
Design And Analysis Of A 3d-Printed, Thermoplastic Elastomer (Tpe) Spring Element For Use In Corrective Hand Orthotics, Kevin Thomas Richardson
Design And Analysis Of A 3d-Printed, Thermoplastic Elastomer (Tpe) Spring Element For Use In Corrective Hand Orthotics, Kevin Thomas Richardson
Theses and Dissertations--Mechanical and Aerospace Engineering
This thesis proposes an algorithm that determine the geometry of 3D-printed, custom-designed spring element bands made of thermoplastic elastomer (TPE) for use in a wearable orthotic device to aid in the physical therapy of a human hand exhibiting spasticity after stroke. Each finger of the hand is modeled as a mechanical system consisting of a triple-rod pendulum with nonlinear stiffness at each joint and forces applied at the attachment point of each flexor muscle. The system is assumed quasi-static, which leads to a torque balance between the flexor tendons in the hand, joint stiffness and the design force applied to …
The Subject Librarian Newsletter, Engineering And Computer Science, Fall 2017, Buenaventura "Ven" Basco
The Subject Librarian Newsletter, Engineering And Computer Science, Fall 2017, Buenaventura "Ven" Basco
Libraries' Newsletters
No abstract provided.
Mechanical Reliability Of Implantable Polyimide-Based Magnetic Microactuators For Biofouling Removal, Christian G. Figueroa-Espada, Qi Yang, Hyowon Lee
Mechanical Reliability Of Implantable Polyimide-Based Magnetic Microactuators For Biofouling Removal, Christian G. Figueroa-Espada, Qi Yang, Hyowon Lee
The Summer Undergraduate Research Fellowship (SURF) Symposium
Hydrocephalus is a neurological disorder that typically requires a long-term implantation of a shunt system to manage its symptoms. These shunt systems are notorious for their extremely high failure rate. More than 40% of all implanted shunt systems fail within the first year of implantation. On average, 85% of all hydrocephalus patients with shunt systems undergo at least two shunt-revision surgeries within 10 years of implantation. A large portion of this high failure rate can be attributed to biofouling-related obstructions and infections. Previously, we developed flexible polyimide-based magnetic microactuators to remove obstructions formed on hydrocephalus shunts. To test the long-term …
Guidance System, Kayaking For The Visually Impaired, D. Ryan Kirtland, Ryan Phife, William Gardner, Amy Johnson
Guidance System, Kayaking For The Visually Impaired, D. Ryan Kirtland, Ryan Phife, William Gardner, Amy Johnson
Biomedical Engineering
Quality Life Plus is working with Team River Runner to develop an assistive guidance system for veterans who want to remain active by kayaking, after sustaining an injury that impairs vision. This system allows these veterans to complete a slalom speed race independent of a personal guide in the water. The system incorporates 3 stations that each contain a speaker connected to a microcontroller system covered by a Pelican Case on a custom made buoy. During the slalom race, a kayaker will travel from shore towards buoy #1 as it omits sound from the speaker. As the kayaker moves around …