Open Access. Powered by Scholars. Published by Universities.®
Other Biomedical Engineering and Bioengineering Commons™
Open Access. Powered by Scholars. Published by Universities.®
- Institution
-
- California Polytechnic State University, San Luis Obispo (15)
- University of Nebraska - Lincoln (6)
- University of Arkansas, Fayetteville (4)
- Bucknell University (3)
- Clemson University (2)
-
- Georgia Southern University (2)
- Purdue University (2)
- University of Connecticut (2)
- University of Denver (2)
- University of New Mexico (2)
- American University in Cairo (1)
- Brigham Young University (1)
- City University of New York (CUNY) (1)
- Kennesaw State University (1)
- LSU New Orleans (1)
- Louisiana Tech University (1)
- Michigan Technological University (1)
- Old Dominion University (1)
- South Dakota State University (1)
- Technological University Dublin (1)
- The British University in Egypt (1)
- The University of Akron (1)
- University of Central Florida (1)
- University of Louisville (1)
- University of Mississippi (1)
- University of South Alabama (1)
- Virginia Commonwealth University (1)
- Washington University in St. Louis (1)
- West Virginia University (1)
- Western University (1)
- Keyword
-
- Biomechanics (3)
- Piezoelectric (3)
- 3D Printing (2)
- Biodegradable (2)
- Bone Regeneration (2)
-
- Daniel Felix Ritchie School of Engineering and Computer Science (2)
- Learning (2)
- Mechanical and Materials Engineering (2)
- Poly-L-Lactic Acid (PLLA) (2)
- Ultrasound (2)
- 3D Print (1)
- 3D-printing (1)
- 3T3 (1)
- Acrylated Epoxidized Linseed Oil (1)
- Actin myosin cross bridges (1)
- Actuators (1)
- Adaptive (1)
- Adaptive Sports (1)
- Adaptive fishing (1)
- Adaptive recreational activities (1)
- Additive Manufacturing (1)
- Additive manufacturing (1)
- Agarose absorption (1)
- Allergy (1)
- Altered vessel hemodynamics. (1)
- Alzheimer’s Disease (AD) (1)
- Amputee (1)
- Amygdala (1)
- Anaphylaxis (1)
- Anatomical phantom (1)
- Publication Year
- Publication
-
- Biomedical Engineering (6)
- Mechanical Engineering (5)
- Master's Theses (4)
- Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research (3)
- Electronic Theses and Dissertations (3)
-
- Biomedical Engineering Undergraduate Honors Theses (2)
- Department of Mechanical and Materials Engineering: Faculty Publications (2)
- Mechanical Engineering Undergraduate Honors Theses (2)
- The Summer Undergraduate Research Fellowship (SURF) Symposium (2)
- Theses and Dissertations (2)
- All Dissertations (1)
- All Theses (1)
- Biomedical Engineering ETDs (1)
- Biomedical Engineering Western Regional Conference (1)
- Chemistry & Biochemistry Faculty Publications (1)
- College of Graduate Studies: Theses & Dissertations (1)
- Department of Engineering Mechanics: Dissertations, Theses, and Student Research (1)
- Dissertations and Theses (1)
- Dissertations, Master's Theses and Master's Reports (1)
- Doctoral (1)
- Doctoral Dissertations (1)
- Faculty & Staff Scholarship (1)
- Faculty Conference Papers and Presentations (1)
- Faculty Journal Articles (1)
- General Engineering (1)
- Honors College Theses (1)
- Honors Scholar Theses (1)
- Honors Theses (1)
- Honors Undergraduate Theses (1)
- LSU New Orleans Theses and Dissertations (1)
- Publication Type
Articles 31 - 60 of 60
Full-Text Articles in Other Biomedical Engineering and Bioengineering
Exploring Attacks And Defenses In Additive Manufacturing Processes: Implications In Cyber-Physical Security, Nicholas Deily
Exploring Attacks And Defenses In Additive Manufacturing Processes: Implications In Cyber-Physical Security, Nicholas Deily
McKelvey School of Engineering Graduate Student Theses & Dissertations
Many industries are rapidly adopting additive manufacturing (AM) because of the added versatility this technology offers over traditional manufacturing techniques. But with AM, there comes a unique set of security challenges that must be addressed. In particular, the issue of part verification is critically important given the growing reliance of safety-critical systems on 3D printed parts. In this thesis, the current state of part verification technologies will be examined in the con- text of AM-specific geometric-modification attacks, and an automated tool for 3D printed part verification will be presented. This work will cover: 1) the impacts of malicious attacks on …
The Tera Multi Terrain Mobility Aid Chassis, Colton Kemp, Daniel Nicoll, Ibrahim Suleiman, Mohammad Alyami
The Tera Multi Terrain Mobility Aid Chassis, Colton Kemp, Daniel Nicoll, Ibrahim Suleiman, Mohammad Alyami
Williams Honors College, Honors Research Projects
The natural environment poses a significant number of obstacles and dynamic settings that makes mobility difficult for those with physical and mobility impairments. To approach this problem, a suspension was designed using inspiration from the early Mars rovers developed by NASA for traversing the varied Martian landscape. The course of the project followed the direction of a start-up through problem identification, early design generation and review, and final design production. The project outcome, through client request and proven market research, aimed to produce a multi-terrain wheelchair. The final product is a kinematic body with mobile front “legs” and a rotational …
The Effect Of Radial Head Hemiarthroplasty Stem Fit On Radiocapitellar Contact Mechanics: Is Loose Fit Better Than Rigidly Fixed?, Jakub Szmit, Graham J.W. King, James A. Johnson, G. Daniel G. Langohr
The Effect Of Radial Head Hemiarthroplasty Stem Fit On Radiocapitellar Contact Mechanics: Is Loose Fit Better Than Rigidly Fixed?, Jakub Szmit, Graham J.W. King, James A. Johnson, G. Daniel G. Langohr
Western Research Forum
Background/Methods: Radial head hemiarthroplasty is commonly employed to manage comminuted displaced fractures. With regards to implant fixation, current designs vary with some prostheses aiming to achieve a tight 'fixed' fit, and others utilizing a smooth stem with an over reamed 'loose' fit. The purpose of the present study was to evaluate the effect of radial head hemiarthroplasty stem fit on radiocapitellar contact using a finite element model which simulated both fixed (size-for-size) and loose (1, 2 & 3mm over reamed) stem fits.
Hypothesis: It was hypothesized that a loose stem fit would improve radiocapitellar contact mechanics, with increased contact area …
Cooking Hand Multi-Tool, Amanda D. Meares, Amy H. Wilson, Ethan G. Littlejohn, Duania A. Evans
Cooking Hand Multi-Tool, Amanda D. Meares, Amy H. Wilson, Ethan G. Littlejohn, Duania A. Evans
Biomedical Engineering
The purpose of this project was to devise a solution for Jorge Segura, a US Marine who was wounded in Afghanistan and had to have his non-dominant arm amputated above the elbow. His current prosthetic attachments are not suited to cooking tasks, so he needed a way to cook more effectively with either prosthetic attachments or accessibility devices. The main tasks that he needed help with was holding down food on cutting boards and stabilizing pots, pans, and bowls especially when stirring. After background research, exploring commercially available devices, and talking with our challenger, our solution was to design three …
Development Of A Sonically Powered Biodegradable Nanogenerator For Bone Regeneration, Avi S. Patel
Development Of A Sonically Powered Biodegradable Nanogenerator For Bone Regeneration, Avi S. Patel
University Scholar Projects
Background: Reconstruction of bone fractures and defects remains a big challenge in orthopedic surgery. While regenerative engineering has advanced the field greatly using a combination of biomaterial scaffolds and stem cells, one matter of difficulty is inducing osteogenesis in these cells. Recent works have shown electricity’s ability to promote osteogenesis in stem cell lines when seeded in bone scaffolds; however, typical electrical stimulators are either (a) externally housed and require overcomplex percutaneous wires be connected to the implanted scaffold or (b) implanted non-degradable devices which contain toxic batteries and require invasive removal surgeries.
Objective: Here, we establish a biodegradable, piezoelectric …
Development Of A Sonically Powered Biodegradable Nanogenerator For Bone Regeneration, Avi Patel
Development Of A Sonically Powered Biodegradable Nanogenerator For Bone Regeneration, Avi Patel
Honors Scholar Theses
Background: Reconstruction of bone fractures and defects remains a big challenge in orthopedic surgery. While regenerative engineering has advanced the field greatly using a combination of biomaterial scaffolds and stem cells, one matter of difficulty is inducing osteogenesis in these cells. Recent works have shown electricity’s ability to promote osteogenesis in stem cell lines when seeded in bone scaffolds; however, typical electrical stimulators are either (a) externally housed and require overcomplex percutaneous wires be connected to the implanted scaffold or (b) implanted non-degradable devices which contain toxic batteries and require invasive removal surgeries.
Objective: Here, we establish a biodegradable, piezoelectric …
Methods To Remotely Eliminate Biofilm From Medical Implants Using 2.4 Ghz Microwaves, Brett Glenn
Methods To Remotely Eliminate Biofilm From Medical Implants Using 2.4 Ghz Microwaves, Brett Glenn
Mechanical Engineering Undergraduate Honors Theses
Infections associated with biofilm growth are usually challenging to eradicate due to their high tolerance toward antibiotics [11, 12]. Biofilms often form on the inert surfaces of medically implanted devices [13]. No matter the sophistication, microbial infections can develop on all medical devices and tissue engineering constructs [12]. Related infections lead to 2 million cases annually in the U.S., costing the healthcare system over $5 billion in additional healthcare expenses [12].
Novel solutions to biofilm’s microbial colonization span the spectrum of engineering and science disciplines. Yet a practical solution still does not exist. The research presented here will explore a …
Development Of A Counter-Flow Thermal Gradient Microfluidic Device, Shayan Davani
Development Of A Counter-Flow Thermal Gradient Microfluidic Device, Shayan Davani
Doctoral Dissertations
This work presents a novel counter-flow design for thermal stabilization of microfluidic thermal reactors. In these reactors, precise control of temperature of the liquid sample is achieved by moving the liquid sample through the thermal zones established ideally through the conduction in the solid material of the device. The goal here is to establish a linear thermal distribution when there is no flow and to minimize the temperature change at flow condition. External convection as well as internal flowinduced effects influence the prescribed thermal distribution. The counter-flow thermal gradient device developed in this study is capable of both stabilizing the …
Multi-Purpose Heart Valve Therapy Assembly Fixture, Alec John Foster, John Patrick Hofstetter, Emily Lim
Multi-Purpose Heart Valve Therapy Assembly Fixture, Alec John Foster, John Patrick Hofstetter, Emily Lim
Mechanical Engineering
STATEMENT OF CONFIDENTIALITY: The complete senior project report was submitted to the project advisor and sponsors. The results of this project are of a confidential nature and will not be published at this time.
Eigenstrain As A Mechanical Set-Point Of Cells, Shengmao Lin, Marsha C. Lampi, Cynthia A. Reinhart-King, Gary C.P. Tsui, Jian Wang, Carl A. Nelson, Linxia Gu
Eigenstrain As A Mechanical Set-Point Of Cells, Shengmao Lin, Marsha C. Lampi, Cynthia A. Reinhart-King, Gary C.P. Tsui, Jian Wang, Carl A. Nelson, Linxia Gu
Department of Mechanical and Materials Engineering: Faculty Publications
Cell contraction regulates how cells sense their mechanical environment. We sought to identify the set-point of cell contraction, also referred to as tensional homeostasis. In this work, bovine aortic endothelial cells (BAECs), cultured on substrates with different stiffness, were characterized using traction force microscopy (TFM). Numerical models were developed to provide insights into the mechanics of cell–substrate interactions. Cell contraction was modeled as eigenstrain which could induce isometric cell contraction without external forces. The predicted traction stresses matched well with TFM measurements. Furthermore, our numerical model provided cell stress and displacement maps for inspecting the fundamental regulating mechanism of cell …
Analytical Cpg Model Driven By Limb Velocity Input Generates Accurate Temporal Locomotor Dynamics, Sergiy Yakovenko, Anton Sobinov, Valeriya Gritsenko
Analytical Cpg Model Driven By Limb Velocity Input Generates Accurate Temporal Locomotor Dynamics, Sergiy Yakovenko, Anton Sobinov, Valeriya Gritsenko
Faculty & Staff Scholarship
The ability of vertebrates to generate rhythm within their spinal neural networks is essential for walking, running, and other rhythmic behaviors. The central pattern generator (CPG) network responsible for these behaviors is well-characterized with experimental and theoretical studies, and it can be formulated as a nonlinear dynam- ical system. The underlying mechanism responsible for locomotor behavior can be expressed as the process of leaky integration with resetting states generating appropriate phases for changing body velocity. The low-dimensional input to the CPG model generates the bilateral pattern of swing and stance modulation for each limb and is consistent with the desired …
Mimicking Blood Rheology For More Accurate Modeling In Benchtop Research, Lindsey Webb
Mimicking Blood Rheology For More Accurate Modeling In Benchtop Research, Lindsey Webb
Honors Undergraduate Theses
To confirm computer simulations and Computational Fluid Dynamics (CFD) analysis, benchtop experiments are needed with a fluid that mimics blood and its viscoelastic properties. Blood is challenging to use as a working fluid in a laboratory setting because of health and safety concerns. Therefore, a blood analogue is necessary to perform benchtop experiments. Viscosity is an important property of fluids for modeling and experiments. Blood is a shear thinning fluid, so it has a decreasing viscosity with higher shear rates. This project seeks to create a blood mimicking fluid for benchtop laboratory use. Numerous fluids with different combinations of water, …
A Parametric Study Of The Mechanics Of Different Skin Flap Techniques, Steven J. Meza, Adrián Tepole Buganza
A Parametric Study Of The Mechanics Of Different Skin Flap Techniques, Steven J. Meza, Adrián Tepole Buganza
The Summer Undergraduate Research Fellowship (SURF) Symposium
In modern day plastic and reconstructive surgeries numerous skin flap designs have been developed and are used to close open wounds. Skin flaps are developed with the intention of imposing minimal tension in skin closure. Excessive tension can lead to poor blood flow that result in post-surgery complications such as necrosis. Currently there is no standard in choosing a skin flap design and a surgeon's choice is based personal experience. A comparison of the mechanical loading in these various designs has not yet been done. We have developed a parametric study, using finite element analysis, of two advancement skin flaps …
Blood-Brain Barrier-On-A-Chip Systems Based On 3d Printing, Cade I. Harding
Blood-Brain Barrier-On-A-Chip Systems Based On 3d Printing, Cade I. Harding
Mechanical Engineering Undergraduate Honors Theses
This research focused on the design and testing of a blood-brain barrier (BBB)-on-a-chip microfluidic device produced using 3D printing. First, COMSOL simulations were used to define dimensions of the microchannel that would most accurately replicate the flow environment imposed on the blood-brain barrier, the wall shear stress being the most important characteristic. In using COMSOL, water was used as the simulated fluid and also the testing fluid in the fabricated devices. Therefore, the microsystem is designed to produce the BBB environment using water instead of blood. The numerical simulation parameters were based on theoretical calculations performed to scale up the …
Design And Validation Of An In Vivo Long-Term Attachment Capsule Robot, Wanchuan Xie
Design And Validation Of An In Vivo Long-Term Attachment Capsule Robot, Wanchuan Xie
Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research
The invention of capsule endoscopy (CE) made the non-invasive monitoring of the entire small bowel possible and became the primary means for diagnosing small bowel pathology. In the last decade, capsule robots have been transformed from diagnostic devices into a widely studied biomedical platform with the potential for active locomotion, drug delivery and therapeutic capabilities. To perform accurate on-site drug release and therapy, it is necessary for a capsule robot to be able to attach to the intestinal tissue and maintain its position long-term. Design challenges derive from the task of long-term mucosal adhesion which requires firm, quick-response attachment without …
A Nanocomposite Sensor Neck Sleeve For Tracking In Vivo Spine Kinematics In The Alpaca, Colton Porter Graham, Anton Bowden
A Nanocomposite Sensor Neck Sleeve For Tracking In Vivo Spine Kinematics In The Alpaca, Colton Porter Graham, Anton Bowden
Biomedical Engineering Western Regional Conference
Chronic low back pain in the US is often attributed to intervertebral disc degeneration. Camelids, particularly alpacas, pose a potential model for spinal treatment due to similarity of the spinal structure and vertical loading. Alpacas also exhibit a high rate of natural disc degeneration. To gain more understanding about how disc degeneration is caused in alpacas it is necessary to understand the loading and motion of the alpaca cervical spine. The goal of the present work was to incorporate nanocomposite sensors into a custom-designed neck sleeve to track the daily in-vivo neck motion of an alpaca in its natural environment.
Portable Sensory Room For The West Orange County Consortium For Special Education, Lindsey Chase, Emma Eskildsen, Alex Fox, Claire Francis, Nate Hoffman, Kaylee Keck, Sarah Sullivan
Portable Sensory Room For The West Orange County Consortium For Special Education, Lindsey Chase, Emma Eskildsen, Alex Fox, Claire Francis, Nate Hoffman, Kaylee Keck, Sarah Sullivan
Biomedical Engineering
This report discusses the development of a Portable Sensory Room to be used at Newland Elementary School in Huntington Beach. Newland Elementary has an exceptional Special Needs program that teaches the children with the most severe cases of autism in its school district. People with autism typically also have sensory processing disorders, which can be extremely disruptive for a child’s development and can make it difficult for a child to be able to concentrate long enough to gain necessary life skills. The idea behind a Sensory Rooms is to create a place to calm the students and to expose them …
Biomechanical Investigation Of Elite Place-Kicking, Chase M. Pfeifer
Biomechanical Investigation Of Elite Place-Kicking, Chase M. Pfeifer
Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research
Many studies aim to understand the fundamentals of kicking commonly displayed by soccer players [4,6,10,16,17,18,24,25,28,29,30,34,36,38,40]. Of those studies, most are limited to a two-dimensional (2D) analysis using high-speed cameras for position tracking or utilizing electromyography to observe the activity of select muscles [4,6,18,25,29,36]. The few studies that investigate kicking using a three-dimensional (3D) model are limited in their position tracking capabilities and focus mainly on joint flexion potentials and foot speed.
This dissertation is a comprehensive biomechanical analysis (kinematic and EMG) of the field-goal place-kicking techniques of four elite kickers in American football. Data were compared and contrasted with ball …
Indentation Probing Of In Vitro Bovine Articular Cartilage: Effects On Chondrocyte Viability And Tissue Biomechanics, Pablo F. Argote, Alan Poon, Xin Xu Ph.D, Corey P. Neu Ph.D.
Indentation Probing Of In Vitro Bovine Articular Cartilage: Effects On Chondrocyte Viability And Tissue Biomechanics, Pablo F. Argote, Alan Poon, Xin Xu Ph.D, Corey P. Neu Ph.D.
The Summer Undergraduate Research Fellowship (SURF) Symposium
Osteoarthritis (OA) consists of a degenerative disease on articular cartilage, which is prone to excessive mechanical loading and frictional resistance that leads to the wear and tear of the tissue. These factors result in the progressive and incurable disease that affects millions of people worldwide. The goal is to characterize chondrocyte viability and the in vitro biomechanical properties of articular cartilage in two confined indentation studies. One study looks at the chondrocyte viability over seven days. The second compares the immediate effects of strain rates on chondrocyte viability and tissue biomechanics. Bovine cartilage explants are harvested, cultured, and then 40% …
Sapien3 Comb Stitch Improvement For Edwards Lifesciences, William Harley, Thomas Pluschkell, John Mctigue, Garrett Reed
Sapien3 Comb Stitch Improvement For Edwards Lifesciences, William Harley, Thomas Pluschkell, John Mctigue, Garrett Reed
Mechanical Engineering
The complete senior project report was submitted to the project advisor and sponsor. The results of this project are of a confidential nature and will not be published at this time.
Experimental And Numerical Investigation Of The Mechanism Of Blast Wave Transmission Through A Surrogate Head, Yi Hua, Praveen Akula, Linxia Gu, Jeff Berg, Carl A. Nelson
Experimental And Numerical Investigation Of The Mechanism Of Blast Wave Transmission Through A Surrogate Head, Yi Hua, Praveen Akula, Linxia Gu, Jeff Berg, Carl A. Nelson
Department of Mechanical and Materials Engineering: Faculty Publications
This work is to develop an experiment-validated numerical model to elucidate the wave transmission mechanisms through a surrogate head under blast loading. Repeated shock tube tests were conducted on a surrogate head, i.e., water-filled polycarbonate shell. Surface strain on the skull simulant and pressure inside the brain simulant were recorded at multiple locations. A numerical model was developed to capture the shock wave propagation within the shock tube and the fluid-structure interaction between the shock wave and the surrogate head. The obtained numerical results were compared with the experimental measurements. The experiment-validated numerical model was then used to further understand …
Application Of Limited Mixing In The Hele–Shaw Geometry In Fabrication Of Janus Hydrogels, Md Mahmudur Rahman
Application Of Limited Mixing In The Hele–Shaw Geometry In Fabrication Of Janus Hydrogels, Md Mahmudur Rahman
Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research
It is widely accepted that cells behave differently responding to the stiffness of their extracellular matrix (ECM). Such observations were made by culturing cells on hydrogel substrates of tunable stiffness. However, it was recently proposed that cells may sense how strongly they are tethered to ECM, not the local stiffness of ECM. To investigate both hypotheses, we developed a method to fabricate Janus polyacrylamide (PAAM) gels. We squeeze two drops of different concentrations in the Hele-Shaw geometry to generate radial Stokes flow. When the drops coalesce, limited mixing occurs at the interface due to the narrow confinement, and diffusion normal …
Analysis And Modeling Of The Roles Of Actin-Myosin Interactions In Bladder Smooth Muscle Biomechanics, Seyed Omid Komariza
Analysis And Modeling Of The Roles Of Actin-Myosin Interactions In Bladder Smooth Muscle Biomechanics, Seyed Omid Komariza
Theses and Dissertations
Muscle mechanical behavior potentially plays an important role in some of the most common bladder disorders. These include overactive bladder, which can involve involuntary contractions during bladder filling, and impaired contractility or underactive bladder, which may involve weak or incomplete contractions during voiding. Actin-myosin cross-bridges in detrusor smooth muscle (DSM) are responsible for contracting and emptying the bladder. The total tension produced by muscle is the sum of its preload and active tensions. Studies suggest that actin-myosin cross-links are involved in adjustable preload stiffness (APS), which is characterized by a preload tension curve that can be shifted along the length …
Sequential Structural And Fluid Dynamics Analysis Of Balloon-Expandable Coronary Stents., David Martin
Sequential Structural And Fluid Dynamics Analysis Of Balloon-Expandable Coronary Stents., David Martin
Doctoral
As in-stent restenosis following coronary stent deployment has been strongly linked with stent-induced arterial injury and altered vessel hemodynamics, the sequential numerical analysis of the mechanical and hemodynamic impact of stent deployment within a coronary artery is likely to provide an excellent indication of coronary stent performance. Despite this observation, very few numerical studies have considered both the mechanical and hemodynamic impact of stent deployment. In light of this observation, the aim of this research is to develop a robust numerical methodology for investigating the performance of balloon-expandable coronary stents in terms of their mechanical and hemodynamic impact within a …
Guidance System, Kayaking For The Visually Impaired, D. Ryan Kirtland, Ryan Phife, William Gardner, Amy Johnson
Guidance System, Kayaking For The Visually Impaired, D. Ryan Kirtland, Ryan Phife, William Gardner, Amy Johnson
Biomedical Engineering
Quality Life Plus is working with Team River Runner to develop an assistive guidance system for veterans who want to remain active by kayaking, after sustaining an injury that impairs vision. This system allows these veterans to complete a slalom speed race independent of a personal guide in the water. The system incorporates 3 stations that each contain a speaker connected to a microcontroller system covered by a Pelican Case on a custom made buoy. During the slalom race, a kayaker will travel from shore towards buoy #1 as it omits sound from the speaker. As the kayaker moves around …
Design And Development Of A Stair Ascension Assistive Device For Transfemoral Amputees, Casey Michael Barbarino
Design And Development Of A Stair Ascension Assistive Device For Transfemoral Amputees, Casey Michael Barbarino
Master's Theses
Transfemoral amputees around the world experience increased difficulty in climbing stairs due to lack of muscle, balance, and other factors. The loss of a lower limb greatly diminishes the amount of natural force generation provided that is necessary to propel oneself up stairs. This study investigated possible solutions to the problem of stair ascension for transfemoral amputees by the means of designing and developing an externally attachable device to a prosthesis. The number of amputations from military service has greatly increased since 2008, which shows there is a clear need for assistive devices (Wenke, Krueger, & Ficke, 2012). With the …
Hydraulically Driven Mechanical Representation Of A Biological System, Andrea Argouarch, Michael Mceachern, Brandon Parham
Hydraulically Driven Mechanical Representation Of A Biological System, Andrea Argouarch, Michael Mceachern, Brandon Parham
Biomedical Engineering
No abstract provided.
Fracture Of Bone Using Microindentation, Séverine Vennin
Fracture Of Bone Using Microindentation, Séverine Vennin
Department of Engineering Mechanics: Dissertations, Theses, and Student Research
Osteoporosis is a current disease which is especially of concern to post-menopausal women. It is characterized by a decrease of bone density and an increase in the risk of fracture. Interest in the fracture mechanisms with respect to the underlying biological structure of the bone is of great interest to researchers in this field. In this thesis, a new method based on microindentation on rat femurs was developed to determine the relation between the viscoelastic and the fracture properties of bone. The main goal is to measure the viscoelastic properties by using a dynamic mechanical analysis indentation method and then …
An Investigation Of Humeral Stress Fractures In Racing Thoroughbreds Using A 3d Finite Element Model In Conjunction With A Bone Remodeling Algorithm, Ryan James Moore
An Investigation Of Humeral Stress Fractures In Racing Thoroughbreds Using A 3d Finite Element Model In Conjunction With A Bone Remodeling Algorithm, Ryan James Moore
Master's Theses
The humerus of a racing horse Thoroughbred is highly susceptible to stress fractures at a characteristic location as a result of cyclic loading. The propensity of a Thoroughbred to exhibit humeral fracture has made equines useful models in the epidemiology of stress fractures. In this study, a racing Thoroughbred humerus was simulated during training using a 3D finite element model in conjunction with a bone remodeling algorithm. Nine muscle forces and two contact forces were applied to the 3-dimensional finite element model, which contains four separate load cases representing fore-stance, mid-stance, aft-stance, and standing. Four different training programs were incorporated …
Mechanical Simulation Of Articular Cartilage Based On Experimental Results, Kevin Matthew Stewart
Mechanical Simulation Of Articular Cartilage Based On Experimental Results, Kevin Matthew Stewart
Master's Theses
Recently, a constituent based cartilage growth finite element model (CGFEM) was developed in order to predict articular cartilage (AC) biomechanical properties before and after growth. Previous research has noted limitations in the CGFEM such as model convergence with growth periods greater than 12 days. The main aims of this work were to address these limitations through (1) implementation of an exact material Jacobian matrix definition using the Jaumann-Kirchhoff (J-K) method and (2) quantification of elastic material parameters based upon research findings of the Cal Poly Cartilage Biomechanics Group (CPGBG). The J-K method was successfully implemented into the CGFEM and exceeded …