Open Access. Powered by Scholars. Published by Universities.®

California Polytechnic State University, San Luis Obispo

Discipline
Keyword
Publication Year
Publication
Publication Type

Articles 121 - 150 of 213

Full-Text Articles in Biomedical Devices and Instrumentation

Slit Lamp Ophthalmoscope Redesign, Michael Hostetler, Austin Mattmiller, Alexis Brewer Mar 2019

Slit Lamp Ophthalmoscope Redesign, Michael Hostetler, Austin Mattmiller, Alexis Brewer

Biomedical Engineering

The slit lamp ophthalmoscope is used by ophthalmologists for diagnosis of pathologies in the eye. The device is used for identifying ocular diseases or indications of other possible systemic diseases to treat them before the diseases progress. Redesign of the ergonomics and adjustment mechanisms of the slit lamp ophthalmoscope will attempt to improve the compatibility of the device across a greater variety of patients. The wider headrest tower of 12.75 inches, the wider table cutout of 12 inches, and the 12 inches of extension of the headrest tower creates a better ergonomic fit for the patient and doctor. The wider …


Development Of A Myoelectric Detection Circuit Platform For Computer Interface Applications, Nickolas Andrew Butler Mar 2019

Development Of A Myoelectric Detection Circuit Platform For Computer Interface Applications, Nickolas Andrew Butler

Master's Theses

Personal computers and portable electronics continue to rapidly advance and integrate into our lives as tools that facilitate efficient communication and interaction with the outside world. Now with a multitude of different devices available, personal computers are accessible to a wider audience than ever before. To continue to expand and reach new users, novel user interface technologies have been developed, such as touch input and gyroscopic motion, in which enhanced control fidelity can be achieved. For users with limited-to-no use of their hands, or for those who seek additional means to intuitively use and command a computer, novel sensory systems …


Upright Sleep Device For Patients Required To Sleep Upright Post Surgery/Medical Procedure, Kristin J. Abele, Madeleine H. Hummel, Tayler R. Kastlunger Jan 2019

Upright Sleep Device For Patients Required To Sleep Upright Post Surgery/Medical Procedure, Kristin J. Abele, Madeleine H. Hummel, Tayler R. Kastlunger

Biomedical Engineering

No abstract provided.


Assessing Endothelial Dysfunction Estimating The Differences Between 3 Minute And 5 Minute Reactive Hyperemia, Tamiko K. Saldin Jan 2019

Assessing Endothelial Dysfunction Estimating The Differences Between 3 Minute And 5 Minute Reactive Hyperemia, Tamiko K. Saldin

Master's Theses

The purpose of this study was to define a lower standard cuff occlusion time to induce reactive hyperemia in assessing endothelial dysfunction. In this study, strong evidence was found by a novel technique that used oscillometric methods, which supported that 3 minute reactive hyperemia was sufficient to elicit a significant difference in arterial compliance from baseline. Twenty healthy Cal Poly students were assessed, (n=12 female, n=8 male) aged 22 years old with a standard deviation of 2.04 years. Arterial compliance was estimated by measuring the peak-to-peak oscillations for baseline, 3 minute reactive hyperemia, and 5 minute reactive hyperemia tests, with …


Wireless Ekg, James Kerman, Chin Chao, Galen Wu, Eric Burstedt Dec 2018

Wireless Ekg, James Kerman, Chin Chao, Galen Wu, Eric Burstedt

Mechanical Engineering

In 2016, Dr. Ahmad Nooristani identified a need for a personal EKG that is cheaper and simpler than hospital grade systems, but more accurate than personal devices currently on the market. Two previous teams did significant background research, prototyping, focusing on ease of use, portability, and physical specifications. However, neither team was able to produce a device with electrodes that could successfully collect an EKG signal and transmit it to a phone or tablet, one of the main requirements from the Dr. Nooristani. This team focused on designing a six lead, five electrode EKG device to transmit EKG data from …


Microfluidic Electrical Impedance Spectroscopy, John J. Foley Sep 2018

Microfluidic Electrical Impedance Spectroscopy, John J. Foley

Master's Theses

The goal of this study is to design and manufacture a microfluidic device capable of measuring changes in impedance valuesof microfluidic cell cultures. Tocharacterize this, an interdigitated array of electrodes was patterned over glass, where it was then bonded to a series of fluidic networks created in PDMS via soft lithography. The device measured ethanol impedance initially to show that values remain consistent over time. Impedance values of water and 1% wt. saltwater were compared to show that the device is able to detect changes in impedance, with up to a 60% reduction in electrical impedance in saltwater. Cells were …


Fixing Vertebral Compression Fractures With Medtronic, Kelly Fitzgerald, Trevor Bingham, Alex Denbaugh, Jordan Tang, Jon Stearns Jun 2018

Fixing Vertebral Compression Fractures With Medtronic, Kelly Fitzgerald, Trevor Bingham, Alex Denbaugh, Jordan Tang, Jon Stearns

Industrial and Manufacturing Engineering

No abstract provided.


Extended-Use Ecg Monitor, Daniel Aaron Soski Jun 2018

Extended-Use Ecg Monitor, Daniel Aaron Soski

Master's Theses

In this thesis, a prototype ECG monitor was developed that is integrated into an elastic shirt and takes a 3-lead ECG for over 5 days. The high-quality measurements can be used to identify markers indicative of various detrimental heart conditions. Measurements recorded by the device are encrypted and stored onto a micro-SD card. Current Holter monitors are expensive and have functional lives less than 48 hours; however, extended duration monitoring has been proven more useful in diagnosis. The device designed demonstrates that ECG measurements can be taken over longer durations without sacrificing quality, comfort, or device cost.


Annuloplasty Mti: Improved Tooling For Annuloplasty Ring Manufacturing, Justin David Smith, Spencer Lee Combs, Luke Edward Maly Jun 2018

Annuloplasty Mti: Improved Tooling For Annuloplasty Ring Manufacturing, Justin David Smith, Spencer Lee Combs, Luke Edward Maly

Mechanical Engineering

The complete senior project report was submitted to the project advisor and sponsor. The results of this project are of a confidential nature and will not be published at this time.


Identification System For Heart Valve Manufacturing, Nicholas Robert Jensen, Edgar Davis Nix, Judith Evelyn Gonzalez, Albert Austin Liddicoat Jun 2018

Identification System For Heart Valve Manufacturing, Nicholas Robert Jensen, Edgar Davis Nix, Judith Evelyn Gonzalez, Albert Austin Liddicoat

Mechanical Engineering

Abstract withheld due to NDA constraints


Transcatheter Heart Valve Leaflet Assembly Tooling Improvement Final Design Report, James Craig Sherman, Zachary Robert Dicks, Luke Edward Williams Jun 2018

Transcatheter Heart Valve Leaflet Assembly Tooling Improvement Final Design Report, James Craig Sherman, Zachary Robert Dicks, Luke Edward Williams

Mechanical Engineering

Statement of Confidentiality: The complete senior project report was submitted to the project advisor and sponsor. The results of this project are of a confidential nature and will not be published at this time.


Dynamic Model For Simulating Motion Of The Right Ventricle, Brian Michael Larsen, Sam Koopman Porter, John Francis D'Ambrosio Jun 2018

Dynamic Model For Simulating Motion Of The Right Ventricle, Brian Michael Larsen, Sam Koopman Porter, John Francis D'Ambrosio

Mechanical Engineering

This report documents all the research, ideation, and mockups used to determine right ventricle motion and develop a system capable of reproducing that motion on a tissue sample. The model is intended for evaluating anchoring systems being developed by Edwards Lifesciences for use with tricuspid valve therapies. Several design solutions were considered for the primary functions of recreating motion of the right ventricle and attaching tissue to the device. From these ideas a primary means of producing motion and attaching tissue was selected. These ideas were then developed over the course of a school year to become the final system …


Virtual Stethoscope/Otoscope Duo, Camila P. Monchini, Paige R. Mazur, Christian Navarro Mar 2018

Virtual Stethoscope/Otoscope Duo, Camila P. Monchini, Paige R. Mazur, Christian Navarro

Biomedical Engineering

The virtual stethoscope/otoscope duo is a medical device intended to allow patients to be seen by their medical provider via internet consultations from the comfort of their own home. This device allows patients to substitute in-person doctor visits by checking a patient’s cardiovascular, respiratory, and auditory health. This document is the statement of work for the virtual stethoscope/otoscope duo and contains information on similar products, patents, and relevant literatures containing virtual technologies that assist in patient diagnosis. Product specifications and other details for the device such as performance evaluation review techniques can also be found within this document outlining the …


Preparation For The Study Of Gene Expression Aboard The International Space Station, Amber Paturzo Jan 2018

Preparation For The Study Of Gene Expression Aboard The International Space Station, Amber Paturzo

STAR Program Research Presentations

WetLab-2 performs quantitative polymerase chain reaction (qPCR) aboard the micro-gravity environment of the International Space Station in order to research how the stress of micro-gravity affects an organism’s RNA production and gene expression. This on-station qPCR allows researchers to gather information earlier and thereby allow them to modify experiments in a matter of hours rather than wait until the next flight opportunity. After a successful validation flight on SpaceX-8 and follow-up investigation on SpaceX-9, system components must now be adjusted for a new type of biological sample. Specifically, the WetLab-2 facility includes a commercial qPCR instrument (RNA SmartCycler), a sample …


Eeg Characterization During Motor Tasks That Are Difficult For Movement Disorder Patients, Adam Joshua Aslam Dec 2017

Eeg Characterization During Motor Tasks That Are Difficult For Movement Disorder Patients, Adam Joshua Aslam

Master's Theses

Movement disorders are a group of syndromes that often arise due to neurological abnormalities. Approximately 40 million Americans are affected by some form of movement disorder, significantly impacting patients’ quality of life and their ability to live independently. Deep brain stimulation (DBS) is one treatment that has shown promising results in the past couple decades, however, the currently used open-loop system has several drawbacks. By implementing a closed-loop or adaptive DBS (aDBS) system, the need for expensive parameter reprogramming sessions would be reduced, side-effects may be relieved, and habituation could be avoided. Several biomarkers, for example signals or activity derived …


Skin Tone Tracking Device (Chromaband), Ziyang Bian Jun 2017

Skin Tone Tracking Device (Chromaband), Ziyang Bian

Computer Engineering

It’s long been said that your skin is a window into your health and with many illnesses the first signs of trouble actually show up in your skin. So if we have this natural warning system, then why isn’t anyone able to effectively use it to predict changes in our health? The problem is that currently there is no reliable way to accurately measure the change in skin tone and how these changes may or may not change with variations in health. This project’s aim is to design and develop a device that will record the changes in a user’s …


Poly Drop, Zachary T. Scott, Lilly J. Paul Jun 2017

Poly Drop, Zachary T. Scott, Lilly J. Paul

Computer Engineering

Poly Drop is a software interface to control an Open Drop digital micro-fluidics system. We obtained a hardware system from Gaudi labs. Our task was to create a Graphical User Interface that made the control of the device easier and more automated for better testing. We created software that had 3 parts: a control GUI, arduino code to control the hardware, and Image Analysis that gives the user information such as location and color of liquid drops as they move across the electrode grid of the Open Drop system. The GUI was developed using Java Swing. The communication between the …


Redesign Of The Medtronic Kyphon Bone Cement Mixer For Vertebral Compression Fractures, Mollie Benson, Sarah Freesemann, Aj Konnath, Benjamin Murray Jun 2017

Redesign Of The Medtronic Kyphon Bone Cement Mixer For Vertebral Compression Fractures, Mollie Benson, Sarah Freesemann, Aj Konnath, Benjamin Murray

Biomedical Engineering

The complete senior project report was submitted to the project advisor and sponsor. The results of this project are of a confidential nature and will not be published at this time.


Final Design Report: Polymer Fatigue Characterization Test Method, Wyatt Ayling, Tyler Price, Brandon Stell, Michela Upson Dec 2016

Final Design Report: Polymer Fatigue Characterization Test Method, Wyatt Ayling, Tyler Price, Brandon Stell, Michela Upson

Mechanical Engineering

Polylogix is a team dedicated to the design, build, and testing of a fatigue machine to simulate cyclic loading on a biomedical polymer. This project is sponsored by Endologix, Inc. to provide test data characterizing mechanical material properties of various formulations of polymer used in abdominal aortic aneurysm surgeries. With this project goal, the machine must be able to test the polymer at body conditions; these include a testing temperature of 37°C and a cycling frequency ranging from 1 Hz to 10 Hz. This report proposes the following solution to this design challenge: an AC motor-driven mechanism utilizing a planetary …


A 3-D Multiplex Paper-Microfluidic Platform, Mitchell Patrick Young Sep 2016

A 3-D Multiplex Paper-Microfluidic Platform, Mitchell Patrick Young

Master's Theses

3-D paper-based microfluidic devices (micoPADs) are small and portable devices made out of paper that offer a promising platform for diagnostic applications outside of a laboratory. These devices are easy to use, low cost, require no power source, and capable of detecting multiple targets simultaneously. The work in this thesis demonstrated the ability of a 3-D paper-microfluidic platform to simultaneously detect 5 targets. Rubber cord stock was used in conjunction with an acrylic housing unit to apply pressure along the edge of the channel. The indirect pressure application was successful in promoting vertical fluid flow between layers. Average channel development …


Fluid Flow Characterization And In Silico Validation In A Rapid Prototyped Aortic Arch Model, Alexandra Mariel Knauer Aug 2016

Fluid Flow Characterization And In Silico Validation In A Rapid Prototyped Aortic Arch Model, Alexandra Mariel Knauer

Master's Theses

Transcatheter aortic heart valve replacement (TAVR) is a procedure to replace a failing aortic valve and is becoming the new standard of care for patients that are not candidates for open-heart surgery [2]. However, this minimally invasive technique has shown to cause ischemic brain lesions, or “silent infarcts”, in 90% of TAVR patients, which can increase the patient’s risk for stroke by two to four times in future years [3]. Claret Medical Inc., a medical device company, has developed a cerebral protection system that filters and captures embolic debris released during endovascular procedures, such as TAVR. This thesis utilized CT …


Modification Of Offset Hip Impactor, Anton Gebert, Michael Rumery, Mark Sidor Jun 2016

Modification Of Offset Hip Impactor, Anton Gebert, Michael Rumery, Mark Sidor

Mechanical Engineering

More than 300,000 total hip replacement surgeries are performed in the US each year. Minimally invasive total hip replacement surgery requires modified tools to access the smaller incision. An offset hip impactor was redesigned to improve tool lifetime, ease of use, and manufacturing cost. The redesigned tool had an increased lifetime and a significant reduction in the number of parts. The report contains detail drawings, a manufacturing plan, and physical testing results.


Prosthetic Socket Cooling System, Benjamin K. Kraw, Kathy Ha, Derek Piastrelli, Cuong Lai Jun 2016

Prosthetic Socket Cooling System, Benjamin K. Kraw, Kathy Ha, Derek Piastrelli, Cuong Lai

Mechanical Engineering

A team of four senior-level undergraduate students in the Interdisciplinary Senior Project Design course in the Engineering Department of California Polytechnic State University: San Luis Obispo have worked to develop a prosthetic socket cooling system, namely for veteran Taylor Morris and exclusively for a transfemoral prosthetic socket, under the Quality of Life+ Laboratory. This cooling system will utilize the thermoelectric effect known as the Peltier effect to transmit heat generated from the residual limb to the surrounding environment by means of forced convection over small aluminum heat sinks. Two measurement devices have also been developed to, one, measure the heat …


Improvement Of Mounting Techniques For Accelerated Wear Testing Of Artificial Heart Valves, Kyle Koon, Clay Bougher, Lawrence Yang Jun 2016

Improvement Of Mounting Techniques For Accelerated Wear Testing Of Artificial Heart Valves, Kyle Koon, Clay Bougher, Lawrence Yang

Mechanical Engineering

Confidential


Prosthetic Leg Kit For Deployment In Developing Countries, Brian Murphy, Dominique Porcincula, Derek Morgan, Kendall Ruggles, Christian Aguayo Jun 2016

Prosthetic Leg Kit For Deployment In Developing Countries, Brian Murphy, Dominique Porcincula, Derek Morgan, Kendall Ruggles, Christian Aguayo

Biomedical Engineering

The World Health Organization estimates that over 30 million people require some sort of prosthetic technology. However, traditional prosthetic fitting practices take a lot of time and cost a lot of money, making them inaccessible to millions of people around the world. StandUP Worldwide is an interdisciplinary project team devoted to creating low-cost prosthetic technologies for use around the world, especially in resource poor areas. They are currently developing a low cost, below-the-knee prosthetic kit that can be easily deployed in a resource-poor area. The following presents their solution for a below-the-knee prosthetic socket, foot, and leg.


Design And Validation Of A Fall Detection Application For Ios, Connor Lewis Mosley Mar 2016

Design And Validation Of A Fall Detection Application For Ios, Connor Lewis Mosley

Master's Theses

Despite significant preventative efforts, falls continue to be a major source of morbidity and mortality among the elderly. Additionally, the fear of falling can be a major obstacle to independent living for otherwise self-sufficient individuals. This fear is significantly heightened in individuals who have sustained a fall and often results in self-imposed restrictions on mobility and exercise, causing weakening in these individuals and further exacerbating the danger. Much time has been spent developing alert systems in an attempt to mitigate these problems. Unfortunately these systems typically involve dedicated monitoring centers and therefore often come with substantial upfront and recurring costs. …


Design And Analysis Of A Lift Assist Walker, Deep P. Shah Mar 2016

Design And Analysis Of A Lift Assist Walker, Deep P. Shah

Master's Theses

Walkers provided stability to the elderly but cannot assist a person from sitting to standing. The objective of this project is to present the design and analysis of a lift assist walker. This report discusses the design and analysis of a collapsible lift assist walker capable of lifting a patient up to 250 lbs. from seated to standing in under 10 seconds. The designed walker utilized a two stage scissor mechanism with a gas spring assisted embedded linear actuator.


The Effect Of Neurostimulation On Ischemic Pain And Methods Of Assessing Pain, Kaylee Keck Dec 2015

The Effect Of Neurostimulation On Ischemic Pain And Methods Of Assessing Pain, Kaylee Keck

Biomedical Engineering

Peripheral arterial disease (PAD) impacts approximately eight million people in the United States [1]. Disease progression leads to chronic ischemic pain, hindering quality of life. Pharmaceuticals are a typical treatment for pain associated with PAD; but as few as 30% of patients have a significant reduction of pain (≥50%) [2].

Neurostimulation is commonly used as a treatment for various diseases and injuries, including Parkinson’s disease and sports-related back and knee injuries [2]. The objective of the study was to explore neurostimulation and its effect on pain and paresthesia for a model of acute peripheral ischemia in young college students.

Pain …


Quantification Of Blood Flow Velocity Using Color Sensing, Aditya Deepak Sanghani Oct 2015

Quantification Of Blood Flow Velocity Using Color Sensing, Aditya Deepak Sanghani

Master's Theses

Blood flow velocity is an important parameter that can give information on several pathologies including atherosclerosis, glaucoma, Raynaud’s phenomenon, and ischemic stroke [2,5,6,10]. Present techniques of measuring blood flow velocity involve expensive procedures such as Doppler echocardiography, Doppler ultrasound, and magnetic resonance imaging [11,12]. They cost from $8500-$20000. It is desired to find a low-cost yet equally effective solution for measuring blood flow velocity. This thesis has a goal of creating a proof of concept device for measuring blood flow velocity.

Finger blood flow velocity is investigated in this project. The close proximity to the skin of the finger’s arteries …


Micro Electrostatic Actuation Of A Silicon Diaphragm, Matthew W. Samples Jun 2015

Micro Electrostatic Actuation Of A Silicon Diaphragm, Matthew W. Samples

Master's Theses

There are a number of applications, from hearing aids to microfluidic pumps, which utilize micro-scale actuating diaphragms. These MEMS (micro-electromechanical system) devices can be actuated by electrostatic forces, which utilize an induced electric field to pull two charged plates towards one another. Such devices were fabricated and electrostatic actuation of the diaphragms was performed to analyze its viability as a micro-speaker. The long-term performance of such products requires adequate diaphragm deflection to create audible pressure waves with relatively low maximum stresses to ensure a high cycle fatigue life. With these requirements, initial calculations and FEA (finite element analysis) were performed …