Open Access. Powered by Scholars. Published by Universities.®
Biomedical Devices and Instrumentation Commons™
Open Access. Powered by Scholars. Published by Universities.®
- Institution
-
- University of Nebraska - Lincoln (8)
- California Polytechnic State University, San Luis Obispo (6)
- Marquette University (3)
- University of Arkansas, Fayetteville (3)
- Virginia Commonwealth University (3)
-
- Dartmouth College (2)
- LSU Health New Orleans (2)
- Technological University Dublin (2)
- The Texas Medical Center Library (2)
- The University of Akron (2)
- University of Denver (2)
- University of South Alabama (2)
- Bridgeport Hospital (1)
- Brigham Young University (1)
- Bucknell University (1)
- City University of New York (CUNY) (1)
- Duquesne University (1)
- East Tennessee State University (1)
- Embry-Riddle Aeronautical University (1)
- Himmelfarb Health Sciences Library, The George Washington University (1)
- New Jersey Institute of Technology (1)
- Nova Southeastern University (1)
- Old Dominion University (1)
- Providence (1)
- Purdue University (1)
- Tower Health (1)
- University of Central Florida (1)
- University of Connecticut (1)
- University of Louisville (1)
- University of Malaya (1)
- Keyword
-
- Machine learning (3)
- Radiotherapy (3)
- Angiogenesis (2)
- Biomedical engineering (2)
- Concussion (2)
-
- Daniel Felix Ritchie School of Engineering and Computer Science (2)
- Electro-larynx (2)
- Heart failure (2)
- Intelligibility (2)
- Laryngectomy (2)
- MATLAB (2)
- Mechanical and Materials Engineering (2)
- Minimally invasive surgery (2)
- Neuroscience (2)
- Parkinson's Disease (2)
- Simulation (2)
- 3D Stem Cell Culture (1)
- 3D-printing (1)
- Absorbable staples (1)
- AccelerometerADXL343 Triple Axisalarm monitorbubble detectorCAD/CAM softwareCPAP devicedisplay systemgas flowmeterhumidifierintegrated circuitlight emitting diodeprintersensorwaterairflowalarm monitoringarticlebubble continuous positive airway pressurebubble continuous positive airway pressure disconnectioncomputer aided designcontrolled studydevice failurehypoxianeonatal intensive care unitnewborn careproduct designsimulationvibration (1)
- Acoustic Transmission (1)
- Aged (1)
- Air-jetting Bioprinting (1)
- Airway clearance technique (1)
- Alginate (1)
- Alzheimer's disease (1)
- Amputation (1)
- Aortic phantom (1)
- Aortic stenosis (1)
- Applied sciences (1)
- Publication Year
- Publication
-
- Biomedical Engineering (4)
- Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research (4)
- Electronic Theses and Dissertations (4)
- Theses and Dissertations (3)
- Conference Papers (2)
-
- Department of Mechanical and Materials Engineering: Faculty Publications (2)
- Graduate Theses and Dissertations (2)
- Master's Theses (2)
- Master's Theses (2009 -) (2)
- School of Medicine Faculty Publications (2)
- Williams Honors College, Honors Research Projects (2)
- Articles, Abstracts, and Reports (1)
- Biomedical Engineering Undergraduate Honors Theses (1)
- Biomedical Engineering Western Regional Conference (1)
- Dartmouth College Ph.D Dissertations (1)
- Department of Civil and Environmental Engineering: Dissertations, Theses, and Student Research (1)
- Department of Psychology: Faculty Publications (1)
- Discovery Day - Daytona Beach (1)
- Dissertations (1)
- Dissertations (1934 -) (1)
- ENGS 88 Honors Thesis (AB Students) (1)
- Faculty Conference Papers and Presentations (1)
- Faculty, Staff and Student Publications (1)
- Graduate Theses and Dissertations (2019 - present) (1)
- HCA-NSU MD Research Day (1)
- Honors Scholar Theses (1)
- Honors Theses (1)
- Honors Undergraduate Theses (1)
- Journal of Mind and Medical Sciences (1)
- McKelvey School of Engineering Graduate Student Theses & Dissertations (1)
- Publication Type
Articles 31 - 60 of 60
Full-Text Articles in Biomedical Devices and Instrumentation
Designing An Antibiotic Eluting Trauma Screw To Reduce Short Term Infection In Bone Fractures, Dominic Lincoln
Designing An Antibiotic Eluting Trauma Screw To Reduce Short Term Infection In Bone Fractures, Dominic Lincoln
Honors Theses
Orthopedic infection in the United States is one of the most common and severe health risks faced by trauma patients. The most prevalent infection is orthopedic and trauma device-related infection (ORDI) and often occurs in long bones at the fracture site. The purpose of this paper is to explore this infection, its causes, and solutions currently on the market while providing novel solutions to the problem. The designs proposed will be evaluated for their effectiveness and value, while attempting to keep costs low for all stakeholders. The feasibility of patenting these ideas will also be considered, as will the testing …
Total Knee Arthroplasty Gap Balancer, Christina Grigorian, Andrew Beckley, Alexandra Rockett
Total Knee Arthroplasty Gap Balancer, Christina Grigorian, Andrew Beckley, Alexandra Rockett
Biomedical Engineering
California Polytechnic State University’s Biomedical Engineering Department worked in conjunction with local San Luis Obispo orthopedic surgeon Dr. Dimitri Delagrammaticas. The goal of the project was to create a surgical tool that assists a surgeon in measuring knee gap distance and balancing collateral ligament tension during a total knee arthroplasty (TKA) surgery. The final product of this project was completed in five months and initially began with understanding our sponsor’s expectations for the device. A portion of time was devoted to conducting research to understand the process of a knee replacement surgery, the requirements of the device, and the limitations …
Development Of A Torque-Based Device For The Quantification Of Arm Rigidity In Patients With Parkinson’S Disease, Georgina O. Miller
Development Of A Torque-Based Device For The Quantification Of Arm Rigidity In Patients With Parkinson’S Disease, Georgina O. Miller
Theses and Dissertations
Parkinsonian rigidity is caused by the inability of the muscles to relax and extend properly, due to reduced dopamine levels and often begins on one side of the body before spreading contralaterally. The current standard for determining joint rigidity in a clinical setting is a test completed by the clinician based on the feel of the relaxed wrist and elbow joints as they are passively flexed and extended and a series of ordinal rating scales, the Movement Disorder Society’s – Unified Parkinson’s Disease Rating Scale (MDS-UPDRS), Hoehn and Yahr Scale (H&Y), and Parkinson’s Disease Questionnaire-39 (PDQ-39). These methods are used …
Seeing Eye To Eye: A Machine Learning Approach To Automated Saccade Analysis, Maigh Attre
Seeing Eye To Eye: A Machine Learning Approach To Automated Saccade Analysis, Maigh Attre
Honors Scholar Theses
Abnormal ocular motility is a common manifestation of many underlying pathologies particularly those that are neurological. Dynamics of saccades, when the eye rapidly changes its point of fixation, have been characterized for many neurological disorders including concussions, traumatic brain injuries (TBI), and Parkinson’s disease. However, widespread saccade analysis for diagnostic and research purposes requires the recognition of certain eye movement parameters. Key information such as velocity and duration must be determined from data based on a wide set of patients’ characteristics that may range in eye shapes and iris, hair and skin pigmentation [36]. Previous work on saccade analysis has …
Brain Image Clustering By Wavelet Energy And Cbsso Optimization Algorithm, Hasan Hosseinzadeh, Mohammad Sedaghat
Brain Image Clustering By Wavelet Energy And Cbsso Optimization Algorithm, Hasan Hosseinzadeh, Mohammad Sedaghat
Journal of Mind and Medical Sciences
Previously, the diagnosis of brain abnormality was significantly important in the saving of social and hospital resources. Wavelet energy is known as an effective feature detection which has great efficiency in different utilities. This paper suggests a new method based on wavelet energy to automatically classify magnetic resonance imaging (MRI) brain images into two groups (normal and abnormal), utilizing support vector machine (SVM) classification based on chaotic binary shark smell optimization (CBSSO) to optimize the SVM weights.
The results of the suggested CBSSO-based KSVM are compared favorably to several other methods in terms of better sensitivity and authenticity. The proposed …
Quickcough: An Instrumentational Proximal Airway Clearance Technique (Act) For Select Patients With Neuromuscular Disease (Nmd), Sean X. Sullivan, Russell K. Catania, Madison K. Plaster, Sydney E. Kandray, Mariah Costa
Quickcough: An Instrumentational Proximal Airway Clearance Technique (Act) For Select Patients With Neuromuscular Disease (Nmd), Sean X. Sullivan, Russell K. Catania, Madison K. Plaster, Sydney E. Kandray, Mariah Costa
Williams Honors College, Honors Research Projects
Patients with neuromuscular disease (NMD) requiring tracheostomy and mechanical ventilation secondary to respiratory failure encounter increased difficulty in removing pulmonary secretions from the airways. To combat issues associated with current treatment modalities for insufficient cough efficacy (cost, poor mobility, discomfort, lack of evidence), we have developed an instrumentational proximal airway clearance technique (ACT) which augments a manual proximal ACT developed by a client with NMD. QuickCough is a 3D-printed PLA attachment to the tracheostomy apparatus which has demonstrated its ability to facilitate pressure changes necessary to increase patient’s peak cough flow (PCF) by providing a stronger exsufflation for the patient. …
Dual-Display Laparoscopic Laser Speckle Contrast Imaging For Real-Time Surgical Assistance, Jaepyeong Cha, Corey Zheng, Lung Wai Lau
Dual-Display Laparoscopic Laser Speckle Contrast Imaging For Real-Time Surgical Assistance, Jaepyeong Cha, Corey Zheng, Lung Wai Lau
Pediatrics Faculty Publications
Laser speckle contrast imaging (LSCI) utilizes the speckle pattern of a laser to determine the blood flow in tissues. The current approaches for its use in a clinical setting require a camera system with a laser source on a separate optical axis making it unsuitable for minimally invasive surgery (MIS). With blood flow visualization, bowel viability, for example, can be determined. Thus, LSCI can be a valuable tool in gastrointestinal surgery. In this work, we develop the first-of-its-kind dual-display laparoscopic vision system integrating LSCI with a commercially available 10mm rigid laparoscope where the laser has the same optical axis as …
Extraction And Analysis Of Vector Flow Imaging Data In A Pediatric Population, Bailey Stinnett
Extraction And Analysis Of Vector Flow Imaging Data In A Pediatric Population, Bailey Stinnett
Biomedical Engineering Undergraduate Honors Theses
Vector flow imaging (VFI) is a new ultrasound technology that provides real time, angle-independent visualization of flow velocities in the heart and great vessels. Thus far, VFI has been used for superficial applications due to the limited penetration depth of available transducer probes; however, this depth in smaller pediatric patients enables adequate aortic views. In this project, VFI was used to study pediatric aortic stenosis (PAS)—a congenital heart defect that results in the narrowing of the aorta and/or aortic valve. The decision to refer PAS patients for surgical or catheter-based intervention is initially based on Doppler ultrasound. VFI is potentially …
Ring And Peg Simulation For Minimally Invasive Surgical Robot, Evan Brown
Ring And Peg Simulation For Minimally Invasive Surgical Robot, Evan Brown
Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research
Surgical procedures utilizing minimally invasive laparoscopic techniques have shown less complications, better cosmetic results, and less time in the hospital than conventional surgery. These advantages are partially offset by inherent difficulties of the procedures which include an inverted control scheme, instrument clashing, and loss of triangulation. Surgical robots have been designed to overcome the limitations, the Da Vinci being the most widely used. A dexterous in vivo, two-armed robot, designed to enter an insufflated abdomen with a limited insertion profile and expand to perform a variety of operations, has been created as a less expensive, versatile alternative to the Da …
Reducing Uncertainty In Head And Neck Radiotherapy With Plastic Robotics, Mark R. Ostyn
Reducing Uncertainty In Head And Neck Radiotherapy With Plastic Robotics, Mark R. Ostyn
Theses and Dissertations
One of the greatest challenges in achieving accurate positioning in head and neck radiotherapy is that the anatomy at and above the cervical spine does not act as a single, mechanically rigid body. Current immobilization techniques contain residual uncertainties that are especially present in the lower neck that cannot be reduced by setting up to any single landmark. The work presented describes the development of a radiotherapy friendly mostly-plastic 6D robotic platform for positioning independent landmarks, (i.e., allowing remote, independent positioning of the skull relative to landmarks in the thorax), including analysis of kinematics, stress, radiographic compatibility, trajectory planning, physical …
Effects Of Random Oscillations On Balance Control In Healthy Young Adults, Jacob Van Dehy
Effects Of Random Oscillations On Balance Control In Healthy Young Adults, Jacob Van Dehy
Master's Theses (2009 -)
In human walking, balance control is managed through proactive changes in spatio-temporal parameters of stepping [1]. It has been suggested that continuous disruptions to healthy young adult balance cause greater changes to overall variability of these parameters than a shift in the mean stepping parameters [2]. This suggests that walking may be occurring in a more reactive manner, modulating to maintain balance without increasing the mean significantly. Work using continuous oscillations to treadmill walking suggest there is an interplay between the predictability of a signal used to disrupt subject balance and the degree to which compensation occurs [3]. To determine …
Biomechanical Testing Of An Exercise For Strengthening The Proximal Femur., Alyssa Osbourne
Biomechanical Testing Of An Exercise For Strengthening The Proximal Femur., Alyssa Osbourne
Electronic Theses and Dissertations
Based on the principles of cutting edge bone remodeling research, a unique therapeutic exercise device was designed specifically to improve bone quality at the most critical location of the proximal femur prone to fracture: the superior-lateral femoral neck where the fracture first initiates during a fall. The exercise/device is intended to work by inducing enough strain in the bone to stimulate the body’s natural bone remodeling mechanisms to increase bone density in the proximal femur and consequently prevent a fracture from arising if a fall to the side does occur.
In order to test the proposed exercise, experiments simulating the …
Sensitivity Of Diffuse Reflectance Spectroscopy To Dose- And Depth-Dependent Changes In Tumor Oxygenation After Radiation Therapy, Daria Semeniak
Sensitivity Of Diffuse Reflectance Spectroscopy To Dose- And Depth-Dependent Changes In Tumor Oxygenation After Radiation Therapy, Daria Semeniak
Graduate Theses and Dissertations
Along with chemotherapy, immunotherapy, and surgery, radiotherapy is one of the most common treatments used against cancer. Around 50% of all cancer patients undergo radiation therapy. While for some patients radiotherapy works efficiently and lead to a complete cancer disappearance, for others treatment outcome may be less favorable due to radioresistance processes happening within a tumor on the molecular level. Radioresistance remains a big challenge for modern oncology. The ability to identify radioresistance at the early stage of radiotherapy would help physicians to improve therapy efficiency. At the current moment, despite the rapid progress in cancer understanding and diagnostic modalities, …
Heart Pump Modelling: Design Of Pulsatile Flow Phantoms, Olivia Coiado, Kevin Jones, Parker Schibel, Nicolas De Almeida
Heart Pump Modelling: Design Of Pulsatile Flow Phantoms, Olivia Coiado, Kevin Jones, Parker Schibel, Nicolas De Almeida
Biomedical Engineering Western Regional Conference
The purpose of this project is to build a model, which mimics physiological conditions of the human cardiovascular system in order to simulate the parameters of the human heart in vivo. For this project, it was developed a flow phantom with vessel mimicking material, as well as blood-mimicking and tissue-mimicking fluid. Phantoms in general are specifically designed objects involving dedicated biomaterials to simulate special realistic circuits of human beings. To develop the flow phantom, low-priced biomaterials for blood mimicking fluid, tissue mimicking, and vessel mimicking material was researched.
Keywords: Cardiovascular system, heart pump, modelling, pulsatile.
A Fourier Description Of Covariance, And Separation Of Simultaneously Encoded Slices With In-Plane Acceleration In Fmri, Mary C. Kociuba
A Fourier Description Of Covariance, And Separation Of Simultaneously Encoded Slices With In-Plane Acceleration In Fmri, Mary C. Kociuba
Dissertations (1934 -)
Functional magnetic resonance imaging (fMRI) studies aim to identify localized neural regions associated with a cognitive task performed by the subject. An indirect measure of the brain activity is the blood oxygenation level dependent (BOLD) signal fluctuations observed within the complex-valued spatial frequencies measured over time. The standard practice in fMRI is to discard the phase information after image reconstruction, even with evidence of biological task-related change in the phase time-series. In the first aim of this dissertation, a complex-valued time-series covariance is derived as a linear combination of second order temporal Fourier frequency coefficients. As opposed to magnitude-only analysis, …
Characterization Of Left-Ventricular Thrombus Formation Using High Frequency Ultrasound, Kelsey A. Bullens, Arvin H. Soepriatna, Pavlos P. Vlachos, Craig J. Goergen
Characterization Of Left-Ventricular Thrombus Formation Using High Frequency Ultrasound, Kelsey A. Bullens, Arvin H. Soepriatna, Pavlos P. Vlachos, Craig J. Goergen
The Summer Undergraduate Research Fellowship (SURF) Symposium
Heart failure is a leading cause of death in the United States, and cardiac thrombus, a common morbidity associated with heart failure, significantly increases a patient’s risk of embolic events. The objective of this project is to characterize left-ventricular (LV) thrombus development using high frequency ultrasound imaging in a murine model. C57BL/6J wild-type mice (n=6) were injected intraperitoneally with iron dextran five times a week for six weeks to increase oxidative stress in the heart. Granulocyte-colony stimulating factor (G-CSF) was subcutaneously injected daily during the second week to initiate stem cell migration and stimulate endothelial cell activation, thus increasing the …
Diffusion Modeling And Device Development For Peritoneal Membrane Oxygenation, Liana Hatoum
Diffusion Modeling And Device Development For Peritoneal Membrane Oxygenation, Liana Hatoum
Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research
Acute respiratory distress syndrome (ARDS) is a pulmonary disease that causes hypoxemia and respiratory failure. The mortality rate for ARDS ranges between 27% and 45%. Current treatments including mechanical ventilation and extracorporeal membrane oxygenation (ECMO) are often associated with high risk complications including barotrauma, infection, thrombosis, and hemorrhage. Alternative pulmonary support techniques are needed to improve the survival rate of patients suffering from ARDS. Previous studies introducing pure O2 gas, perfluorocarbons and red blood cells into the intraperitoneal (IP) cavity have reported no effect or only a mild increase in oxygenation. Here we report peritoneal membrane oxygenation (PMO) using …
A Microfluidic-Based Tactile Sensor For Palpating Mice Tumor Tissues, Yichao Yang, Garett Johnson, Dean Krusienski, Siqi Guo, Cheng Lin, Zhili Hao
A Microfluidic-Based Tactile Sensor For Palpating Mice Tumor Tissues, Yichao Yang, Garett Johnson, Dean Krusienski, Siqi Guo, Cheng Lin, Zhili Hao
Mechanical & Aerospace Engineering Faculty Publications
In light of the need of tissue palpation for Robotics-assisted Minimally Invasive Surgery (RMIS), this paper presents a microfluidic-based tactile sensor for palpating mice tissues for tumor localization. The core of the sensor is a 3x3 sensing-plate/transducer array built into a single polydimethylsiloxane (PDMS) microstructure, with a transducer spacing of 3.75mmx1.5mm. Mounted on a robot, the sensor is pressed against a tissue region with a pre-defined indentation depth pattern, and consequently the stiffness distribution across the tissue region translates to the deflection distribution of the sensing-plate array and is captured by the transducer array underneath as resistance changes. Thus, the …
Feasibility Of Using Raman-Based Techniques For Breast Cancer Detection, Sara Mollamohammada
Feasibility Of Using Raman-Based Techniques For Breast Cancer Detection, Sara Mollamohammada
Department of Civil and Environmental Engineering: Dissertations, Theses, and Student Research
Breast cancer is one of the common types of cancer among women all over the world. Early diagnosis is an effective way that improve the treatment process and gives the patients a better chance of survival. Many of the patients infected by breast cancer choose breast conservation surgery (BCS). However, some of those will be subjected to mastectomy, and many will have tumor recurrence as there is no precise technique to show the tumor margins. Raman-based methods are powerful techniques with potential to rapidly differentiate normal from tumor tissues and provides a solution to detect tumor margin. This is because …
Integrating Meal And Exercise Into Personalized Glucoregulation Models: Metabolic Dynamics And Diabetic Athletes, Sofie Schunk
Integrating Meal And Exercise Into Personalized Glucoregulation Models: Metabolic Dynamics And Diabetic Athletes, Sofie Schunk
Master's Theses (2009 -)
Diabetes affects nearly 26 million Americans, according to the American Diabetes Association, with as many as three million Americans who have Type 1 Diabetes (ADA, 2015). Type 1 Diabetes (T1D) is autoimmune and characterized by little to no insulin production whereas Type 2 Diabetes (T2D) concerns insulin resistance and inability to use produced insulin. Factors contributing to current diabetes management and regulation include exercise type, daily movement activities, and distinct tissue compartment metabolism, each challenging to model in a robust and comprehensive manner. Past models are highly limited in regard to exercise and varying glucose fluctuations dependent on type, intensity, …
Development Of A Heart Rate Variability Measurement System Using Embedded Electronics, Naresh Kumar Velmurugan
Development Of A Heart Rate Variability Measurement System Using Embedded Electronics, Naresh Kumar Velmurugan
Graduate Theses and Dissertations
Recent advances in embedded electronics have a remarkable influence on the health care system. One of the most important applications is to monitor the health care of the patients at anytime and anyplace. In the last two decades, many researchers have focused mainly on heart rate variability (HRV) measurements. Patient's heart rate variability should be continuously monitored to help them in case of emergency. Under these circumstances, patients are required to have a HRV measuring kit for a constant observation.
The proposed project focuses on the development of a heart rate variability measurement system with the use of embedded electronics. …
Implementation And Validation Of Aortic Remodeling In Hypertensive Rats, Shijia Zhao, Linxia Gu
Implementation And Validation Of Aortic Remodeling In Hypertensive Rats, Shijia Zhao, Linxia Gu
Department of Mechanical and Materials Engineering: Faculty Publications
A computational framework was implemented and validated to better understand the hypertensive artery remodeling in both geometric dimensions and material properties. Integrating the stress-modulated remodeling equations into commercial finite element codes allows a better control and visualization of local mechanical parameters. Both arterial thickening and stiffening effects were captured and visualized. An adaptive material remodeling strategy combined with the element birth and death techniques for the geometrical growth were implemented. The numerically predicted remodeling results in terms of the wall thickness, inner diameter, and the ratio of elastin to collagen content of the artery were compared with and fine-tuned by …
Design And Development Of A Miniature In Vivo Surgical Robot With Distributed Motor Control For Laparoendoscopic Single-Site Surgery, Eric J. Markvicka
Design And Development Of A Miniature In Vivo Surgical Robot With Distributed Motor Control For Laparoendoscopic Single-Site Surgery, Eric J. Markvicka
Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research
Paradigm shifts in invasiveness, recovery time, cosmesis, and cost have been seen within the field of general surgery through major advances in surgical technology. Some of the most advanced types of general surgery now include Minimally Invasive Surgery (MIS), LaparoEndoscopic Single-Site (LESS) surgery, and Natural Orifice Translumenal Endoscopic Surgery (NOTES). One of the newest and rapidly developing catalysts is robotic platforms. Such platforms have improved ergonomics and control, increased workspace and dexterity, and have surpassed the efficacy of many non-robotic platforms such as traditional laparoscopic surgical tools. This thesis presents the design and development of a four-degree-of-freedom (4- DOF) miniature …
Utilizing Fast Spin Echo Mri To Reduce Image Artifacts And Improve Implant/Tissue Interface Detection In Refractory Parkinson’S Patients With Deep Brain Stimulators, Subhendra N. Sarkar, Pooja R. Sarkar, Efstathios Papavassiliou, Rafael Rojas
Utilizing Fast Spin Echo Mri To Reduce Image Artifacts And Improve Implant/Tissue Interface Detection In Refractory Parkinson’S Patients With Deep Brain Stimulators, Subhendra N. Sarkar, Pooja R. Sarkar, Efstathios Papavassiliou, Rafael Rojas
Publications and Research
Introduction. In medically refractory Parkinson’s disease (PD) deep-brain stimulation (DBS) is an effective therapeutic tool. Postimplantation MRI is important in assessing tissue damage and DBS lead placement accuracy. We wanted to identify which MRI sequence can detectDBS leads with smallest artifactual signal void, allowing better tissue/electrode edge conspicuity.
Methods. Using an IRB approved protocol 8 advanced PDpatientswere imagedwithinMRconditional safety guidelines at lowRF power (SAR ≤ 0.1 W/kg) in coronal plane at 1.5T by various sequences.The image slices were subjectively evaluated for diagnostic quality and the lead contact diameters were compared to identify a sequence least affected by metallic leads.
Results …
Head Impact Exposure In Male And Female Collegiate Ice Hockey Players, Bethany J. Wilcox, Jonathan G. Beckwith, Richard M. Greenwald, Jeffrey J. Chu, Thomas W. Mcallister, Laura A. Flashman, Arthur C. Maerlender, Ann-Christine Duhaime, Joseph J. Crisco
Head Impact Exposure In Male And Female Collegiate Ice Hockey Players, Bethany J. Wilcox, Jonathan G. Beckwith, Richard M. Greenwald, Jeffrey J. Chu, Thomas W. Mcallister, Laura A. Flashman, Arthur C. Maerlender, Ann-Christine Duhaime, Joseph J. Crisco
Department of Psychology: Faculty Publications
The purpose of this study was to quantify head impact exposure (frequency, location and magnitude of head impacts) for individual male and female collegiate ice hockey players and to investigate differences in exposure by sex, player position, session type, and team. Ninety-nine (41 male, 58 female) players were enrolled and 37,411 impacts were recorded over three seasons. Frequency of impacts varied significantly by sex (males: 287 per season, females: 170, p < 0.001) and helmet impact location (p < 0.001) but not by player position (p = 0.088). Head impact frequency also varied by session type; both male and female players sustained more impacts in games than in practices (p < 0.001), however the magnitude of impacts did not differ between session types. There was no difference in 95th percentile peak linear acceleration between sexes (males: 41.6 g, females: 40.8 g), but 95th percentile peak rotational acceleration and HITsp (a composite severity measure) were greater for males than females (4424, 3409 rad/s2, and 25.6, 22.3, respectively). Impacts to the back of the helmet resulted in the greatest 95th percentile peak linear accelerations for males (45.2 g) and females (50.4 g), while impacts to the side and back of the head were associated with the greatest 95th percentile peak rotational accelerations (males: 4719, 4256 rad/sec2, females: 3567, 3784 rad/sec2, respectively). It has been proposed that reducing an individual’s head impact exposure is a practical approach for reducing the risk of …
On The Importance Of Modeling Stent Procedure For Predicting Arterial Mechanics, Shijia Zhao, Linxia Gu, Stacey R. Froemming
On The Importance Of Modeling Stent Procedure For Predicting Arterial Mechanics, Shijia Zhao, Linxia Gu, Stacey R. Froemming
Department of Mechanical and Materials Engineering: Faculty Publications
The stent-artery interactions have been increasingly studied using the finite element method for better understanding of the biomechanical environment changes on the artery and its implications. However, the deployment of balloon-expandable stents was generally simplified without considering the balloon-stent interactions, the initial crimping process of the stent, its overexpansion routinely used in the clinical practice, or its recoil process. In this work, the stenting procedure was mimicked by incorporating all the above-mentioned simplifications. The impact of various simplifications on the stent-induced arterial stresses was systematically investigated. The plastic strain history of stent and its resulted geometrical variations, as well as …
Improving Health Care Quality And Safety: The Development And Assessment Of Laparoscopic Surgery Instrumentation, Practices And Procedures, Bernadette Mccrory
Improving Health Care Quality And Safety: The Development And Assessment Of Laparoscopic Surgery Instrumentation, Practices And Procedures, Bernadette Mccrory
Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research
Adverse events due to medical errors are a leading cause of death in the United States exceeding the mortality rates of motor vehicle accidents, breast cancer and AIDS. Improvements can and should be made to reduce the rates of preventable surgical errors since they account for nearly half of all adverse events within hospitals. Although minimally invasive surgery has proven patient benefits such as reduced postoperative pain and hospital stay, its operative environment imposes substantial physical and cognitive strain on the surgeon increasing the risk of error. In order to mitigate errors and protect patients, a multidisciplinary approach was taken …
Intelligibility Of Electrolarynx Speech Using A Novel Hands-Free Actuator, Brian Madden, Mark Nolan, Ted Burke, James Condron, Eugene Coyle
Intelligibility Of Electrolarynx Speech Using A Novel Hands-Free Actuator, Brian Madden, Mark Nolan, Ted Burke, James Condron, Eugene Coyle
Conference Papers
During voiced speech, the larynx provides quasi-periodic acoustic excitation of the vocal tract. In most electrolarynxes, mechanical vibrations are produced by a linear electromechanical actuator, the armature of which percusses against a metal or plastic plate at a frequency within the range of glottal excitation. In this paper, the intelligibility of speech produced using a novel hands-free actuator is compared to speech produced using a conventional electrolarynx. Two able-bodied speakers (one male, one female) performed a closed response test containing 28 monosyllabic words, once using a conventional electrolarynx and a second time using the novel design. The resulting audio recordings …
Intelligibility Of Electrolarynx Speech Using A Novel Actuator, Brian Madden, Mark Nolan, Ted Burke, James Condron, Eugene Coyle
Intelligibility Of Electrolarynx Speech Using A Novel Actuator, Brian Madden, Mark Nolan, Ted Burke, James Condron, Eugene Coyle
Conference Papers
During voiced speech, the larynx provides quasi-periodic acoustic excitation of the vocal tract. Following a laryngectomy, some people speak using an electrolarynx which replaces the excitatory function of the absent larynx. Drawbacks of conventional electrolarynx designs include the buzzing monotonic sound emitted, the need for a free hand to operate the device, and difficulty experienced by many laryngectomees in adapting to its use. Despite these shortcomings, it remains the preferred method of speech rehabilitation for a substantial minority of laryngectomees. In most electrolarynxes, mechanical vibrations are produced by a linear electromechanical actuator, the armature of which percusses against a metal …
Effects Of Reamer-Femoral Component Offset On Cement Mantle Penetration In Hip Resurfacing Arthroplasty, Mark Lloyd Paulick
Effects Of Reamer-Femoral Component Offset On Cement Mantle Penetration In Hip Resurfacing Arthroplasty, Mark Lloyd Paulick
Master's Theses
Hip resurfacing arthroplasty has changed the treatment of end stage arthritis without severe deformity for young, active adults. Presently, there are varying clinical approaches to implant design selection and cementation techniques. The purpose of this project is to determine what amount of reamer-femoral component offset allows for the best cement penetration into the femoral head.
Rapid prototyped femoral component models were produced with reamer femoral component offsets of 0.0 mm, 0.5 mm, and 1.0 mm. After implantation onto models of reamed femoral heads made from high-density open-cell reticulated carbon foam, cement penetration was assessed from cross-sections of the foam-implant unit. …