Open Access. Powered by Scholars. Published by Universities.®

Electrical and Electronics

Institution
Keyword
Publication Year
Publication
Publication Type

Articles 31 - 51 of 51

Full-Text Articles in Biomedical Devices and Instrumentation

Developing An Optomechanical Approach For Characterizing Mechanical Properties Of Single Adherent Cells, Ali Mehrnezhad May 2019

Developing An Optomechanical Approach For Characterizing Mechanical Properties Of Single Adherent Cells, Ali Mehrnezhad

LSU Doctoral Dissertations

Mechanical properties of a cell reflect its biological and pathological conditions including cellular disorders and fundamental cellular processes such as cell division and differentiation. There have been active research efforts to develop high-throughput platforms to mechanically characterize single cells. Yet, many of these research efforts are focused on suspended cells and use a flow-through configuration. Therefore, adherent cells are detached prior to the characterization, which seriously perturbs the cellular conditions. Also, methods for adherent cells are limited in their throughput.

My study is aimed to fill the technical gap in the field of single cell analysis, which is a high-throughput …


Development Of A Myoelectric Detection Circuit Platform For Computer Interface Applications, Nickolas Andrew Butler Mar 2019

Development Of A Myoelectric Detection Circuit Platform For Computer Interface Applications, Nickolas Andrew Butler

Master's Theses

Personal computers and portable electronics continue to rapidly advance and integrate into our lives as tools that facilitate efficient communication and interaction with the outside world. Now with a multitude of different devices available, personal computers are accessible to a wider audience than ever before. To continue to expand and reach new users, novel user interface technologies have been developed, such as touch input and gyroscopic motion, in which enhanced control fidelity can be achieved. For users with limited-to-no use of their hands, or for those who seek additional means to intuitively use and command a computer, novel sensory systems …


Extended-Use Ecg Monitor, Daniel Aaron Soski Jun 2018

Extended-Use Ecg Monitor, Daniel Aaron Soski

Master's Theses

In this thesis, a prototype ECG monitor was developed that is integrated into an elastic shirt and takes a 3-lead ECG for over 5 days. The high-quality measurements can be used to identify markers indicative of various detrimental heart conditions. Measurements recorded by the device are encrypted and stored onto a micro-SD card. Current Holter monitors are expensive and have functional lives less than 48 hours; however, extended duration monitoring has been proven more useful in diagnosis. The device designed demonstrates that ECG measurements can be taken over longer durations without sacrificing quality, comfort, or device cost.


Power Mobility Sensor Data Collection Verified Through Standardized Pediatric Assessments, Ayshka Elise Rodriguez-Velez Jan 2018

Power Mobility Sensor Data Collection Verified Through Standardized Pediatric Assessments, Ayshka Elise Rodriguez-Velez

UNF Graduate Theses and Dissertations

The collaboration between the School of Engineering and the Department of Physical Therapy at the University of North Florida has introduced the possibility of creating a new environment for pediatric physical therapy assessments. There are currently no methods for remotely monitoring children with impairments. However, with embedded sensor technology in the form of power mobility and accepted therapy assessment tools, remote monitoring can become a possibility. As a part of this work, a ride-on toy car was developed as a remote monitoring device and a case study with a child with a mobility impairment was used as a proof of …


Implantable Wireless Sensor Networks: Application To Measuring Temperature For In Vivo Detection Of Infections, Praharsh Madappaly Veetil Jan 2017

Implantable Wireless Sensor Networks: Application To Measuring Temperature For In Vivo Detection Of Infections, Praharsh Madappaly Veetil

Dissertations, Master's Theses and Master's Reports

It is has been proven that infection in the body cause a local temperature increase due to localized inflammation. Therefore, a method to provide early diagnostic or long-term tracking of this infection will provide great benefits to patients with diabetic foot ulcers or sickle cell disease, and those receiving hemodialysis where they suffer from a weakened immune system. The goal of this project is to develop an implantable wireless temperature sensor based on a wireless sensor network system for monitoring infections in situ. The analog signals from the thermistors are digitized and wirelessly transmitted to a computer with an ez430-rf2500 …


Psychophysiological Analysis Of A Pedagogical Agent And Robotic Peer For Individuals With Autism Spectrum Disorders., Mohammad Nasser Saadatzi Dec 2016

Psychophysiological Analysis Of A Pedagogical Agent And Robotic Peer For Individuals With Autism Spectrum Disorders., Mohammad Nasser Saadatzi

Electronic Theses and Dissertations

Autism spectrum disorder (ASD) is a neurodevelopmental disorder characterized by ongoing problems in social interaction and communication, and engagement in repetitive behaviors. According to Centers for Disease Control and Prevention, an estimated 1 in 68 children in the United States has ASD. Mounting evidence shows that many of these individuals display an interest in social interaction with computers and robots and, in general, feel comfortable spending time in such environments. It is known that the subtlety and unpredictability of people’s social behavior are intimidating and confusing for many individuals with ASD. Computerized learning environments and robots, however, prepare a predictable, …


Design And Development Of A Wearable Wireless Health Monitoring System: A Smart Watch Approach, Keerthi Paranikumar Dec 2015

Design And Development Of A Wearable Wireless Health Monitoring System: A Smart Watch Approach, Keerthi Paranikumar

Graduate Theses and Dissertations

According to Statistics, every year, about 610,000 people die because of heart disease in United States of America. (i.e. 1 in every 4 deaths.*) Heart disease is common for both men and women. Annually, about 370,000 people die because of coronary heart disease, which is the most common type of heart disease [1]. About 735,000 Americans have heart attack every year. In this, 210,000 people gets heart attack who already has heart problems and 525,000 people get heart attack for the first time [2]. Not many people know that they have heart problems. Around 47% of the people in United …


Design And Fabrication Techniques Of Devices For Embedded Power Active Contact Lens, Errol Heradio Leon Jun 2015

Design And Fabrication Techniques Of Devices For Embedded Power Active Contact Lens, Errol Heradio Leon

Master's Theses

This thesis designed and fabricated various devices that were interfaced to an IC for an active contact lens that notifies the user of an event by detection of an external wireless signal. The contact lens consisted of an embedded antenna providing communication with a 2.4GHz system, as well as inductive charging at an operating frequency of 13.56 MHz. The lens utilized a CBC005 5µAh thin film battery by Cymbet and a manufactured graphene super capacitor as a power source. The custom integrated circuit (IC) was designed using the On Semiconductor CMOS C5 0.6 µm process to manage …


Design And Development Of Two Component Hydrogel Ejector For Three-Dimensional Cell Growth, Thomas Dunkle, Jessica Deschamps, Connie Dam May 2015

Design And Development Of Two Component Hydrogel Ejector For Three-Dimensional Cell Growth, Thomas Dunkle, Jessica Deschamps, Connie Dam

Honors Scholar Theses

Hydrogels are useful in wound healing, drug delivery, and tissue engineering applications, but the available methods of injecting them quickly and noninvasively are limited. The medical industry does not yet have access to an all-purpose device that can quickly synthesize hydrogels of different shapes and sizes. Many synthesis procedures that have been developed result in the formation of amorphous hydrogels. While generally useful, amorphous hydrogels exhibit limited capability in tissue engineering applications, especially due to their viscous properties. This endeavor aims to modulate the appropriate gelation parameters, optimize the injection process, and create a prototype that allows for the extrusion …


Assessment Of Electrode Configurations Of Electrical Impedance Myography For The Evaluation Of Neuromuscular Diseases, Khondokar Mohammad Fazle Rabbi Jan 2015

Assessment Of Electrode Configurations Of Electrical Impedance Myography For The Evaluation Of Neuromuscular Diseases, Khondokar Mohammad Fazle Rabbi

College of Graduate Studies: Theses & Dissertations

Electrical impedance myography (EIM) is a painless, noninvasive approach to measure the neuromuscular disease status. EIM parameters- resistance (R), reactance (X) and phase (θ) depend significantly on subcutaneous fat thickness, muscle size and inter electrode distance. The objective of this research is to find an electrode configuration which can minimize the effects on EIM parameters due to subcutaneous fat thickness variation. In this study, a model of human upper arm was developed using finite element method (FEM), which has already been established as an appropriate approach for the analysis of non-symmetrical shape for assessing alternations of muscle in disease-induced changes …


Team Omnimouse, Derek J. Halman, Josh B. Porter, Steven A. Silver, Ian S. Stemper Jun 2014

Team Omnimouse, Derek J. Halman, Josh B. Porter, Steven A. Silver, Ian S. Stemper

Computer Engineering

INFORMATION, DATA, FIGURES AND DRAWINGS EMBODIED IN THIS DOCUMENT ARE STRICTLY CONFIDENTIAL AND ARE SUPPLIED ON THE UNDERSTANDING THAT THEY WILL NOT BE DISCLOSED TO THIRD PARTIES WITHOUT THE PRIOR WRITTEN CONSENT OF QUALITY OF LIFE PLUS.


Sonar For The Visually Impaired, Anastasia Newark, Edwin Ng, Scott Terhorst Jun 2014

Sonar For The Visually Impaired, Anastasia Newark, Edwin Ng, Scott Terhorst

Biomedical Engineering

There are currently no inexpensive assistive devices that allow the visually impaired detect low hanging objects that are above waist height and may cause injury, such as a rope or tree branch. The challenge presented to the team by the Quality of Life Plus Lab (QL+) was to develop a Sonar Cane device that attaches to a traditional white cane to address this problem. This device must be lightweight, inexpensive to manufacture, have a long battery life, and accurately detect obstacles to prevent user injury.


Design And Implementation Of Wireless Point-Of-Care Health Monitoring Systems: Diagnosis For Sleep Disorders And Cardiovascular Diseases, Se Chang Oh May 2013

Design And Implementation Of Wireless Point-Of-Care Health Monitoring Systems: Diagnosis For Sleep Disorders And Cardiovascular Diseases, Se Chang Oh

Graduate Theses and Dissertations

Chronic sleep disorders are present in 40 million people in the United States. More than 25 million people remain undiagnosed and untreated, which accounts for over $22 billion in unnecessary healthcare costs. In addition, another major chronic disease is the heart diseases which cause 23.8% of the deaths in the United States. Thus, there is a need for a low cost, reliable, and ubiquitous patient monitoring system. A remote point-of-care system can satisfy this need by providing real time monitoring of the patient's health condition at remote places. However, the currently available POC systems have some drawbacks; the fixed number …


A Wireless And Digital Electrode Bus Topology For Biopotential Measurement, Mark Nolan, Edward Burke, Eugene Coyle Jun 2012

A Wireless And Digital Electrode Bus Topology For Biopotential Measurement, Mark Nolan, Edward Burke, Eugene Coyle

Conference Papers

The conventional biopotential measurement configuration utilises long lead wires which connect measuring electrodes to signal conditioning circuitry. The majority of bioelectric signals that are measured from the human body have a tiny signal amplitude (5µV-5mV range) and thus any interference that is induced on the lead wires can have a detrimental effect on the original signal. In this paper, we present an alternative configuration, in which digitisation occurs on the electrode, potentially providing enhanced signal measurement as well as significant benefits in terms of the simplification of the physical interconnections between electrodes. Multiple electrodes are combined to form a digital …


Heart-Rate Monitoring Control System Using Photoplethysmography (Ppg), Wesley Nguyen, Ryan Horjus Jun 2011

Heart-Rate Monitoring Control System Using Photoplethysmography (Ppg), Wesley Nguyen, Ryan Horjus

Electrical Engineering

No abstract provided.


Universal Engineering Programmer – An In-House Development Tool For Developing And Testing Implantable Medical Devices In St. Jude Medical, Khoa Tat Do Mar 2011

Universal Engineering Programmer – An In-House Development Tool For Developing And Testing Implantable Medical Devices In St. Jude Medical, Khoa Tat Do

Master's Theses

During development and testing of the functionality of the pacemaker and defibrillator device, engineers in the St. Jude Medical Cardiac Rhythm Management Division use an in-house development tool called Universal Engineering Programmer (UEP) to ensure the device functions as expected, before it can be used to test on an animal or a human during the implantation process.  In addition, some applications of UEP are incorporated into the official releases of the device product.  UEP has been developed and used by engineers across departments in the St. Jude Medical Cardiac Rhythm Management Division (CRMD).  This thesis covers the flexible and reusable …


Intelligibility Of Electrolarynx Speech Using A Novel Hands-Free Actuator, Brian Madden, Mark Nolan, Ted Burke, James Condron, Eugene Coyle Jan 2011

Intelligibility Of Electrolarynx Speech Using A Novel Hands-Free Actuator, Brian Madden, Mark Nolan, Ted Burke, James Condron, Eugene Coyle

Conference Papers

During voiced speech, the larynx provides quasi-periodic acoustic excitation of the vocal tract. In most electrolarynxes, mechanical vibrations are produced by a linear electromechanical actuator, the armature of which percusses against a metal or plastic plate at a frequency within the range of glottal excitation. In this paper, the intelligibility of speech produced using a novel hands-free actuator is compared to speech produced using a conventional electrolarynx. Two able-bodied speakers (one male, one female) performed a closed response test containing 28 monosyllabic words, once using a conventional electrolarynx and a second time using the novel design. The resulting audio recordings …


Augmented Control Of A Hands-Free Electrolarynx, Brian Madden, James Condron, Eugene Coyle Jan 2011

Augmented Control Of A Hands-Free Electrolarynx, Brian Madden, James Condron, Eugene Coyle

Conference Papers

During voiced speech, the larynx acts as the sound source, providing a quasi-periodic excitation of the vocal tract. Following a total laryngectomy, some people speak using an electrolarynx which employs an electromechanical actuator to perform the excitatory function of the absent larynx. Drawbacks of conventional electrolarynx designs include the monotonic sound emitted, the need for a free-hand to operate the device, and the difficulty experienced by many laryngectomees in adapting to its use. One improvement to the electrolarynx, which clinicians and users frequently suggest, is the provision of a convenient hands-free control facility. This would allow more natural use of …


On Improving Electrooculogram-Based Computer Mouse Systems: The Accelerometer Trigger, Johnalan Keegan, Edward Burke, James Condron, Eugene Coyle Jan 2011

On Improving Electrooculogram-Based Computer Mouse Systems: The Accelerometer Trigger, Johnalan Keegan, Edward Burke, James Condron, Eugene Coyle

Conference Papers

Eye tracking is a well-established method of computer control for profoundly paralysed people (Anson et al., 2002). Cameras are commonly used to track eye movements (Morimoto et al., 2005) but one alternative is the bioelectrical signal known as the electrooculogram (EOG). There are some EOG mouse control systems that facilitate the use of GUI applications, but certain actions, which are straightforward using a conventional mouse, remain impossible. Unless the eyes are tracking a target, they move in saccades (jumps), making it impossible to voluntarily trace out smooth trajectories with one's gaze, as would be required to draw a smooth curve. …


Intelligibility Of Electrolarynx Speech Using A Novel Actuator, Brian Madden, Mark Nolan, Ted Burke, James Condron, Eugene Coyle Jun 2010

Intelligibility Of Electrolarynx Speech Using A Novel Actuator, Brian Madden, Mark Nolan, Ted Burke, James Condron, Eugene Coyle

Conference Papers

During voiced speech, the larynx provides quasi-periodic acoustic excitation of the vocal tract. Following a laryngectomy, some people speak using an electrolarynx which replaces the excitatory function of the absent larynx. Drawbacks of conventional electrolarynx designs include the buzzing monotonic sound emitted, the need for a free hand to operate the device, and difficulty experienced by many laryngectomees in adapting to its use. Despite these shortcomings, it remains the preferred method of speech rehabilitation for a substantial minority of laryngectomees. In most electrolarynxes, mechanical vibrations are produced by a linear electromechanical actuator, the armature of which percusses against a metal …


Fetal Heart Rate Detection With A Passive Acoustic Sensor System, Zongyao Zhou Apr 1995

Fetal Heart Rate Detection With A Passive Acoustic Sensor System, Zongyao Zhou

Electrical & Computer Engineering Theses & Dissertations

Research and development is presented of real time signal processing methodologies for the detection of fetal heart tones from noise contaminated signals obtained from passive acoustic sensors. A nonlinear Teager energy operator is utilized for detection of the fetal heart tone event. Autocorrelation and a parallel redundancy correction algorithm derives fetal heart rates. A real time monitoring system is described which records and plots the time history of both the fetal heart rate and the acoustic fetal heart signal. The system is validated in the context of the fetal nonstress test. Comparisons are made with ultrasonic nonstress tests on a …