Open Access. Powered by Scholars. Published by Universities.®
Biomedical Devices and Instrumentation Commons™
Open Access. Powered by Scholars. Published by Universities.®
- Institution
-
- California Polytechnic State University, San Luis Obispo (29)
- University of Nevada, Las Vegas (26)
- University of Arkansas, Fayetteville (11)
- Technological University Dublin (10)
- Old Dominion University (9)
-
- Purdue University (7)
- City University of New York (CUNY) (6)
- Louisiana State University (6)
- Dartmouth College (5)
- Clemson University (4)
- The University of Akron (4)
- University of Nebraska - Lincoln (4)
- Georgia Southern University (3)
- Kennesaw State University (3)
- Michigan Technological University (3)
- University of Connecticut (3)
- University of Kentucky (3)
- University of Malaya (3)
- Chapman University (2)
- Liberty University (2)
- Southern Methodist University (2)
- Tashkent State Technical University (2)
- University of Louisville (2)
- Virginia Commonwealth University (2)
- Air Force Institute of Technology (1)
- American University in Cairo (1)
- Bridgewater College (1)
- Brigham Young University (1)
- California State University, San Bernardino (1)
- Chinese Academy of Sciences (1)
- Keyword
-
- Applied sciences (6)
- Machine Learning (5)
- Arduino (4)
- Biosensor (4)
- Electro-larynx (4)
-
- Intelligibility (4)
- Microfluidics (4)
- Sensor (4)
- Biomedical engineering (3)
- Data acquisition (3)
- Drug delivery (3)
- Electromyography (3)
- Laryngectomy (3)
- Machine learning (3)
- Myoelectric (3)
- Prosthetics (3)
- Signal processing (3)
- Temperature (3)
- Wearable (3)
- Wearable technology (3)
- Alzheimer's Disease (2)
- Biochemical markers (2)
- Bioinstrumentation (2)
- Biomechanics (2)
- Biomedical (2)
- Biomedical Engineering (2)
- Biomedical devices (2)
- Biopotential measurement (2)
- Biosensors (2)
- Blood glucose (2)
- Publication Year
- Publication
-
- UNLV Theses, Dissertations, Professional Papers, and Capstones (25)
- Master's Theses (15)
- Conference Papers (8)
- Graduate Theses and Dissertations (8)
- Electrical Engineering (6)
-
- Electrical & Computer Engineering Theses & Dissertations (5)
- The Summer Undergraduate Research Fellowship (SURF) Symposium (5)
- Biomedical Engineering (4)
- Dartmouth College Ph.D Dissertations (4)
- LSU Doctoral Dissertations (4)
- Williams Honors College, Honors Research Projects (4)
- College of Graduate Studies: Theses & Dissertations (3)
- Computer Engineering (3)
- Dissertations and Theses (3)
- Dissertations, Master's Theses and Master's Reports (3)
- Electronic Theses and Dissertations (3)
- Student Works (2020-2029) (3)
- Symposium of Student Scholars (3)
- Theses and Dissertations (3)
- All Dissertations (2)
- All Theses (2)
- Chemical Technology, Control and Management (2)
- Dissertations (2)
- Electrical and Computer Engineering Faculty Publications (2)
- Engineering Faculty Articles and Research (2)
- Honors Scholar Theses (2)
- LSU Master's Theses (2)
- Publications and Research (2)
- Theses and Dissertations--Electrical and Computer Engineering (2)
- Articles (1)
- Publication Type
- File Type
Articles 151 - 177 of 177
Full-Text Articles in Biomedical Devices and Instrumentation
Design And Implementation Of Wireless Point-Of-Care Health Monitoring Systems: Diagnosis For Sleep Disorders And Cardiovascular Diseases, Se Chang Oh
Graduate Theses and Dissertations
Chronic sleep disorders are present in 40 million people in the United States. More than 25 million people remain undiagnosed and untreated, which accounts for over $22 billion in unnecessary healthcare costs. In addition, another major chronic disease is the heart diseases which cause 23.8% of the deaths in the United States. Thus, there is a need for a low cost, reliable, and ubiquitous patient monitoring system. A remote point-of-care system can satisfy this need by providing real time monitoring of the patient's health condition at remote places. However, the currently available POC systems have some drawbacks; the fixed number …
Independent Component Analysis Enhancements For Source Separation In Immersive Audio Environments, Yue Zhao
Independent Component Analysis Enhancements For Source Separation In Immersive Audio Environments, Yue Zhao
Theses and Dissertations--Electrical and Computer Engineering
In immersive audio environments with distributed microphones, Independent Component Analysis (ICA) can be applied to uncover signals from a mixture of other signals and noise, such as in a cocktail party recording. ICA algorithms have been developed for instantaneous source mixtures and convolutional source mixtures. While ICA for instantaneous mixtures works when no delays exist between the signals in each mixture, distributed microphone recordings typically result various delays of the signals over the recorded channels. The convolutive ICA algorithm should account for delays; however, it requires many parameters to be set and often has stability issues. This thesis introduces the …
A Wireless And Digital Electrode Bus Topology For Biopotential Measurement, Mark Nolan, Edward Burke, Eugene Coyle
A Wireless And Digital Electrode Bus Topology For Biopotential Measurement, Mark Nolan, Edward Burke, Eugene Coyle
Conference Papers
The conventional biopotential measurement configuration utilises long lead wires which connect measuring electrodes to signal conditioning circuitry. The majority of bioelectric signals that are measured from the human body have a tiny signal amplitude (5µV-5mV range) and thus any interference that is induced on the lead wires can have a detrimental effect on the original signal. In this paper, we present an alternative configuration, in which digitisation occurs on the electrode, potentially providing enhanced signal measurement as well as significant benefits in terms of the simplification of the physical interconnections between electrodes. Multiple electrodes are combined to form a digital …
Polygrasp: Reach; Myoelectric Prosthetic Hand Iteration, Devon Patrick Augustus, Mighells Blaed Deuel, Ian Noel Fraser, Nicholas Philip Moesser
Polygrasp: Reach; Myoelectric Prosthetic Hand Iteration, Devon Patrick Augustus, Mighells Blaed Deuel, Ian Noel Fraser, Nicholas Philip Moesser
Mechanical Engineering
Amputations are a common occurrence in soldiers returning home who have suffered the effects of IED and munitions explosions. For upper limb amputees, trans-radial amputations are the most common. Traditional hook devices do not offer an adequate level of normalcy for users, prompting the use of myoelectric devices. While current myoelectric devices do offer a more natural experience, they come with a host of other problems that makes their adoption by service personnel not desirable or not permitted by the VA. PolyGrasp Reach seeks to reduce weight and cost and improve performance. This addresses several of the issues with devices …
The Presence Of Regional Accents In Electrolarynx Speech And The Resultant Effect On Overall Intelligibility., Brian Madden, Eugene Coyle
The Presence Of Regional Accents In Electrolarynx Speech And The Resultant Effect On Overall Intelligibility., Brian Madden, Eugene Coyle
Conference Papers
During voiced speech, the larynx provides quasi-periodic acoustic excitation of the vocal tract. In most electrolarynxes, mechanical vibrations are produced by a linear electromechanical actuator, the armature of which percusses against a metal or plastic plate at a frequency within the range of glottal excitation. In this paper, a phonological analysis of a section of results from an online perceptual intelligibility test was performed which compared speech produced using a novel hands-free electrolarynx and a commercially available electrolarynx. A portion of the test consisted of a closed-set format containing a selection of four sets of four random CVC audio samples …
A Silicon Nanoparticle-Based Polymeric Nano-Composite Material For Glucose Sensing, Qiang Liu, Munir H. Nayfeh, Siu-Tung Yau
A Silicon Nanoparticle-Based Polymeric Nano-Composite Material For Glucose Sensing, Qiang Liu, Munir H. Nayfeh, Siu-Tung Yau
Electrical and Computer Engineering Faculty Publications
A novel non-enzyme glucose sensing material has been prepared by incorporating ultrasmall (1–3 nm) silicon nanoparticles in polyaniline, a conducting polymer, as a nano-composite material (NCM). When deposited on electrodes, the composite material with three-dimensional loading of the nanoparticles showed a significantly enhanced amperometric response to glucose, compared to the nanoparticles deposited on bare electrodes and electrodes immobilized with the enzyme, glucose oxidase. The linear range of the glucose response of NCM electrodes covered both the hypo- and hyper-glycaemic glucose levels. The sensitivity of the NCM electrodes was 2.5 μA cm−2 mM−1. The NCM electrodes’ selectivity for …
Cyberknife Radiation Modeling: Effects Of Relaxed Translational And Rotational Constraints On Healthy Tissue Irradiation, Sudha Bhavaroop Potineni
Cyberknife Radiation Modeling: Effects Of Relaxed Translational And Rotational Constraints On Healthy Tissue Irradiation, Sudha Bhavaroop Potineni
Electrical & Computer Engineering Theses & Dissertations
The Cyberknife system is a robotic radio surgery instrument that is used to treat cancers in different parts of the human body. Because of its accuracy and precision, it has become one of the best radio surgery systems in the world. However, even with Cyberknife the treatment time for one session takes from 30 minutes up to 120 minutes depending on the size, shape, and position of the tumor in the human body. In this research, a solution is presented to aid in reducing this long treatment time. An algorithm is developed which simulates the amount of the healthy tissue …
Heart-Rate Monitoring Control System Using Photoplethysmography (Ppg), Wesley Nguyen, Ryan Horjus
Heart-Rate Monitoring Control System Using Photoplethysmography (Ppg), Wesley Nguyen, Ryan Horjus
Electrical Engineering
No abstract provided.
Universal Engineering Programmer – An In-House Development Tool For Developing And Testing Implantable Medical Devices In St. Jude Medical, Khoa Tat Do
Master's Theses
During development and testing of the functionality of the pacemaker and defibrillator device, engineers in the St. Jude Medical Cardiac Rhythm Management Division use an in-house development tool called Universal Engineering Programmer (UEP) to ensure the device functions as expected, before it can be used to test on an animal or a human during the implantation process. In addition, some applications of UEP are incorporated into the official releases of the device product. UEP has been developed and used by engineers across departments in the St. Jude Medical Cardiac Rhythm Management Division (CRMD). This thesis covers the flexible and reusable …
Sar Map Of Gel Phantom In A 64mhz Mri Birdcage By Fiber-Optic Thermometry And Fdtd Simulation, Chirag Mukesh Patel
Sar Map Of Gel Phantom In A 64mhz Mri Birdcage By Fiber-Optic Thermometry And Fdtd Simulation, Chirag Mukesh Patel
Master's Theses
As implantable medical devices are being used more often to treat medical problems for which pharmaceuticals don’t suffice, it is important to understand their interactions with commonly used medical modalities. The interactions between medical implants and Magnetic Resonance Imaging machines have proven to be a risk for patients with implants.
Implanted medical devices with elongated metallic components can create harmful levels of local heating in a Magnetic Resonance Imaging (MRI) environment [1]. The heating of a biological medium under MRI is monitored via the Specific Absorption Rate (SAR). SAR, defined as power absorbed per unit mass (W/kg), can be calculated …
Novel Bioelectrical Measurement Using A Digital Biopotential Monode, Mark Nolan, Edward Burke, Eugene Coyle
Novel Bioelectrical Measurement Using A Digital Biopotential Monode, Mark Nolan, Edward Burke, Eugene Coyle
Conference Papers
In conventional biopotential recording, two or more electrodes are placed on the body. A unipolar lead records the time-varying electrical potential at a single point (relative to a reference potential) via one signal electrode. A bipolar lead records the time-varying potential difference between two points via two signal electrodes. In each case, the signal electrodes are connected to high impedance amplifier inputs, while an additional electrode provides a low-impedance path between the amplifier and human subject. Bipolar leads are usually preferred since interference appearing at both signal electrodes can be eliminated using an instrumentation amplifier with high CMRR. A drawback …
Intelligibility Of Electrolarynx Speech Using A Novel Hands-Free Actuator, Brian Madden, Mark Nolan, Ted Burke, James Condron, Eugene Coyle
Intelligibility Of Electrolarynx Speech Using A Novel Hands-Free Actuator, Brian Madden, Mark Nolan, Ted Burke, James Condron, Eugene Coyle
Conference Papers
During voiced speech, the larynx provides quasi-periodic acoustic excitation of the vocal tract. In most electrolarynxes, mechanical vibrations are produced by a linear electromechanical actuator, the armature of which percusses against a metal or plastic plate at a frequency within the range of glottal excitation. In this paper, the intelligibility of speech produced using a novel hands-free actuator is compared to speech produced using a conventional electrolarynx. Two able-bodied speakers (one male, one female) performed a closed response test containing 28 monosyllabic words, once using a conventional electrolarynx and a second time using the novel design. The resulting audio recordings …
Augmented Control Of A Hands-Free Electrolarynx, Brian Madden, James Condron, Eugene Coyle
Augmented Control Of A Hands-Free Electrolarynx, Brian Madden, James Condron, Eugene Coyle
Conference Papers
During voiced speech, the larynx acts as the sound source, providing a quasi-periodic excitation of the vocal tract. Following a total laryngectomy, some people speak using an electrolarynx which employs an electromechanical actuator to perform the excitatory function of the absent larynx. Drawbacks of conventional electrolarynx designs include the monotonic sound emitted, the need for a free-hand to operate the device, and the difficulty experienced by many laryngectomees in adapting to its use. One improvement to the electrolarynx, which clinicians and users frequently suggest, is the provision of a convenient hands-free control facility. This would allow more natural use of …
In-Silico Hyperthermia Performance Of A Near-Field Patch Antenna At Various Positions On A Human Body Model, Sergio Curto, Terrence See, Patrick Mcevoy, Max Ammann, Zhi Ning Chen
In-Silico Hyperthermia Performance Of A Near-Field Patch Antenna At Various Positions On A Human Body Model, Sergio Curto, Terrence See, Patrick Mcevoy, Max Ammann, Zhi Ning Chen
Articles
A compact patch applicator designed to enhance targeted energy coupling at 434 MHz is a key enabler for sensitizing temperature increments in body regions containing superficial tumours. A detailed FDTD body model is used to explore simulated RF coupling and temperature increments for typical clinical conditions. The antenna impedance matching, specific absorption rate and thermal distribution parameters are evaluated to identify applied performance outcomes. The analysis reveals physiological-RF coupling patterns for an optimised closely-coupled single element applicator.
On Improving Electrooculogram-Based Computer Mouse Systems: The Accelerometer Trigger, Johnalan Keegan, Edward Burke, James Condron, Eugene Coyle
On Improving Electrooculogram-Based Computer Mouse Systems: The Accelerometer Trigger, Johnalan Keegan, Edward Burke, James Condron, Eugene Coyle
Conference Papers
Eye tracking is a well-established method of computer control for profoundly paralysed people (Anson et al., 2002). Cameras are commonly used to track eye movements (Morimoto et al., 2005) but one alternative is the bioelectrical signal known as the electrooculogram (EOG). There are some EOG mouse control systems that facilitate the use of GUI applications, but certain actions, which are straightforward using a conventional mouse, remain impossible. Unless the eyes are tracking a target, they move in saccades (jumps), making it impossible to voluntarily trace out smooth trajectories with one's gaze, as would be required to draw a smooth curve. …
Multi-Frequency Processing For Lumen Enhancement With Wideband Intravascular Ultrasound, Rory A. Carrillo
Multi-Frequency Processing For Lumen Enhancement With Wideband Intravascular Ultrasound, Rory A. Carrillo
Master's Theses
The application of high frequency ultrasound is the key to higher resolution intravascular ultrasound (IVUS) images. The need to further improve the IVUS spatial resolution may drive the transducer center frequency even higher than the current 40 MHz range. However, increasing the center frequency may be challenging as it leads to stronger scattering echoes from blood. The high level of blood scattering echoes may obscure the arterial lumen and make image interpretation difficult. Blood backscatter levels increase with transmission center frequency at a much greater rate compared to arterial tissue. These different frequency dependencies provide a potential method to distinguish …
Application Of Signal Advance Technology To Electrophysiology, Chris M. Hymel
Application Of Signal Advance Technology To Electrophysiology, Chris M. Hymel
Dissertations and Theses (Open Access)
Medical instrumentation used in diagnosis and treatment relies on the accurate detection and processing of various physiological events and signals. While signal detection technology has improved greatly in recent years, there remain inherent delays in signal detection/ processing. These delays may have significant negative clinical consequences during various pathophysiological events. Reducing or eliminating such delays would increase the ability to provide successful early intervention in certain disorders thereby increasing the efficacy of treatment.
In recent years, a physical phenomenon referred to as Negative Group Delay (NGD), demonstrated in simple electronic circuits, has been shown to temporally advance the detection of …
Intelligibility Of Electrolarynx Speech Using A Novel Actuator, Brian Madden, Mark Nolan, Ted Burke, James Condron, Eugene Coyle
Intelligibility Of Electrolarynx Speech Using A Novel Actuator, Brian Madden, Mark Nolan, Ted Burke, James Condron, Eugene Coyle
Conference Papers
During voiced speech, the larynx provides quasi-periodic acoustic excitation of the vocal tract. Following a laryngectomy, some people speak using an electrolarynx which replaces the excitatory function of the absent larynx. Drawbacks of conventional electrolarynx designs include the buzzing monotonic sound emitted, the need for a free hand to operate the device, and difficulty experienced by many laryngectomees in adapting to its use. Despite these shortcomings, it remains the preferred method of speech rehabilitation for a substantial minority of laryngectomees. In most electrolarynxes, mechanical vibrations are produced by a linear electromechanical actuator, the armature of which percusses against a metal …
Combining Molecular And Imaging Biomarkers To Enhance Maldi Biomarker Analysis, Ayyappa Chowdary Vadlamudi
Combining Molecular And Imaging Biomarkers To Enhance Maldi Biomarker Analysis, Ayyappa Chowdary Vadlamudi
Electrical & Computer Engineering Theses & Dissertations
This thesis presents a three-step method to predict prostate cancer (PCa) regions on biopsy tissue samples based on high confident, low resolution PCa regions marked by a pathologist. First, a prediction model is designed to predict PCa regions using matrix-assisted laser desorption mass spectrometry (MALDI-MS) tissue imaging data from one prostate tissue slice. Second, a texture analysis technique is applied to a high magnification optical image for the same purpose from an adjacent tissue slice. Finally, those two results are fused to obtain the PCa regions that will assist MALDI imaging biomarker analysis. Experiments show that the texture analysis based …
Theory Of ‘Selectivity’ Of Label-Free Nanobiosensors – A Geometro-Physical Perspective, Pradeep R. Nair, Muhammad A. Alam
Theory Of ‘Selectivity’ Of Label-Free Nanobiosensors – A Geometro-Physical Perspective, Pradeep R. Nair, Muhammad A. Alam
Birck and NCN Publications
Modern label-free biosensors are generally far more sensitive and require orders of magnitude less incubation time compared to their classical counterparts. However, a more important characteristic regarding the viability of this technology for applications in Genomics/Proteomics is defined by the ‘Selectivity’, i.e., the ability to concurrently and uniquely detect multiple target biomolecules in the presence of interfering species. Currently, there is no theory of Selectivity that allows optimization of competing factors and there are few experiments to probe this problem systematically. In this article, we use the elementary considerations of surface exclusion, diffusion limited transport, and void distribution function to …
Towards Supervised Autonomous Task Completion Using An In Vivo Surgical Robot, Jason J. Dumpert
Towards Supervised Autonomous Task Completion Using An In Vivo Surgical Robot, Jason J. Dumpert
Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research
Laparoscopy is a minimally invasive alternative to traditional abdominal surgery. Unlike traditional surgery, a laparoscopic procedure can be completed using small incisions. The use of these small incision results in reduced pain to the patient, shorter recovery times, and less trauma to skin, muscle and other tissues. However, these benefits to the patient are offset by the increased difficulty to the surgeon performing the procedure. These difficulties include reduced dexterity, reduced perception, and longer procedure times. The use of small in vivo robotic devices in minimally invasive surgery is one possible solution to these problems. The movement of these devices …
Ekg Tracking For Augmented Standardized Patient Virtual Pathology Stethoscope Heart Auscultation, Sujith Surendran
Ekg Tracking For Augmented Standardized Patient Virtual Pathology Stethoscope Heart Auscultation, Sujith Surendran
Electrical & Computer Engineering Theses & Dissertations
In recent years, a lot of research has focused on improving the clinical skills of medical students and medical practitioners using standardized patients. Standardized patients (SP's) are used by the medical students and physicians in place of mannequins for a more realistic experience. SP's are real people trained to simulate specific illnesses and conditions to a high degree of accuracy which makes it difficult for the medical students to distinguish them from real patients. This research will enhance the capabilities of the standardized patients by providing a non-invasive, natural, harmless and realistic appearing tracking method for placing virtual pathologies using …
Time-Frequency Analysis Of Intracardiac Electrogram, Erik Brockman
Time-Frequency Analysis Of Intracardiac Electrogram, Erik Brockman
Master's Theses
The Cardiac Rhythm Management Division of St. Jude Medical specializes in the development of implantable cardioverter defibrillators that improve the quality of life for patients diagnosed with a variety of cardiac arrhythmias, especially for patients prone to sudden cardiac death. With the goal to improve detection of cardiac arrhythmias, this study explored the value in time-frequency analysis of intracardiac electrogram in four steps. The first two steps characterized, in the frequency domain, the waveforms that construct the cardiac cycle. The third step developed a new algorithm that putatively provides the least computationally expensive way to identifying cardiac waveforms in the …
Magnetic Sensors For Biodetection, Pranjali Vineet Sneha Deshpande
Magnetic Sensors For Biodetection, Pranjali Vineet Sneha Deshpande
UNLV Theses, Dissertations, Professional Papers, and Capstones
The objective of thesis is to design magnetic sensor for detection of nanoparticles. Recently integrating the standard laboratory techniques into integrated system on chip is growing attention. Recent development is to combine magnetic markers and magnetoresistive sensors together in magnetic chip. In this thesis two magnetoresistive sensors were studied and designed.
By applying magnetic fields, magnetic nanoparticles can be manipulated on-chip, which can be utilized to pull the molecules to specific binding sites or to test the binding strength and distinguish between specifically and non-specifically bound molecules
Magnetoresistive sensors are compatible with the semiconductor industry which provides electronic signal directly …
A Mobile Ecg Monitoring System With Context Collection, Jin Peng Li, Damon Berry, Richard Hayes
A Mobile Ecg Monitoring System With Context Collection, Jin Peng Li, Damon Berry, Richard Hayes
Conference Papers
Preventative health management represents a shift from the traditional approach of reactive treatment-based healthcare towards a proactive wellness-management approach where patients are encouraged to stay healthy with expert support when they need it, at any location and any time. This work represents a step along the road towards proactive, preventative healthcare for cardiac patients. It seeks to develop a smart mobile ECG monitoring system that requests and records context information about what is happening around the subject when an arrhythmia event occurs. Context information about the subject’s activities of daily living will, it is hoped, provide an enriched data set …
Fetal Heart Rate Detection With A Passive Acoustic Sensor System, Zongyao Zhou
Fetal Heart Rate Detection With A Passive Acoustic Sensor System, Zongyao Zhou
Electrical & Computer Engineering Theses & Dissertations
Research and development is presented of real time signal processing methodologies for the detection of fetal heart tones from noise contaminated signals obtained from passive acoustic sensors. A nonlinear Teager energy operator is utilized for detection of the fetal heart tone event. Autocorrelation and a parallel redundancy correction algorithm derives fetal heart rates. A real time monitoring system is described which records and plots the time history of both the fetal heart rate and the acoustic fetal heart signal. The system is validated in the context of the fetal nonstress test. Comparisons are made with ultrasonic nonstress tests on a …
Signal Processing Methodologies For An Acoustic Fetal Heart Rate Monitor, Robert A. Pretlow Iii
Signal Processing Methodologies For An Acoustic Fetal Heart Rate Monitor, Robert A. Pretlow Iii
Electrical & Computer Engineering Theses & Dissertations
Research and development is presented of real time signal processing methodologies for the detection of fetal heart tones within a noise-contaminated signal from a passive acoustic sensor. A linear predictor algorithm is utilized for detection of the heart tone event and additional processing derives heart rate. The linear predictor is adaptively "trained" in a least mean square error sense on generic fetal heart tones recorded from patients. A real time monitor system is described which outputs to a strip chart recorder for plotting the time history of the fetal heart rate. The system is validated in the context of the …