Open Access. Powered by Scholars. Published by Universities.®
Biomedical Devices and Instrumentation Commons™
Open Access. Powered by Scholars. Published by Universities.®
- Institution
-
- California Polytechnic State University, San Luis Obispo (7)
- Technological University Dublin (7)
- University of Nevada, Las Vegas (6)
- University of Nebraska - Lincoln (3)
- City University of New York (CUNY) (2)
-
- Dartmouth College (2)
- Murray State University (2)
- University of Louisville (2)
- Bridgewater College (1)
- Bucknell University (1)
- Clemson University (1)
- Georgia Southern University (1)
- Michigan Technological University (1)
- Old Dominion University (1)
- Purdue University (1)
- St. Mary's University (1)
- The University of Southern Mississippi (1)
- University of Central Florida (1)
- University of Connecticut (1)
- University of Kentucky (1)
- University of South Carolina (1)
- University of South Florida (1)
- Keyword
-
- Machine learning (4)
- Electro-larynx (3)
- Intelligibility (3)
- Robotics (3)
- Arduino (2)
-
- Biomedical engineering (2)
- Laryngectomy (2)
- Machine Learning (2)
- Medical imaging (2)
- Myoelectric (2)
- Pager motor (2)
- Prosthetics (2)
- Wearable technology (2)
- 3D Printing (1)
- 3D printing (1)
- Accelerometer (1)
- Actuators (1)
- Affective computing (1)
- Amputees (1)
- Android application (1)
- Ankle (1)
- Artificial intelligence (1)
- Artificial muscle (1)
- Assistive Technologies (1)
- Assistive Technology (1)
- Audio Signal Processing (1)
- Audio filtering (1)
- Automated Skill Assessment (1)
- Avalanche photodiodes (1)
- Band (1)
- Publication Year
- Publication
-
- Conference Papers (7)
- UNLV Theses, Dissertations, Professional Papers, and Capstones (5)
- Computer Engineering (4)
- Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research (2)
- Electronic Theses and Dissertations (2)
-
- Master's Theses (2)
- Mechanical Engineering (2)
- Posters-at-the-Capitol (2)
- All Theses (1)
- College of Graduate Studies: Theses & Dissertations (1)
- Dartmouth College Master’s Theses (1)
- Dartmouth College Ph.D Dissertations (1)
- Department of Electrical and Computer Engineering: Dissertations, Theses, and Student Research (1)
- Discovery Undergraduate Interdisciplinary Research Internship (1)
- Dissertations and Theses (1)
- Dissertations, Master's Theses and Master's Reports (1)
- Electrical & Computer Engineering Theses & Dissertations (1)
- Florida Conference on Recent Advances in Robotics (1)
- Honors Projects (1)
- Honors Scholar Theses (1)
- Honors Undergraduate Theses (1)
- Master’s Theses (1)
- Posters - 2025 (1)
- Publications (1)
- Publications and Research (1)
- School of Public Health Faculty Research (1)
- Theses and Dissertations--Electrical and Computer Engineering (1)
- Publication Type
- File Type
Articles 31 - 45 of 45
Full-Text Articles in Biomedical Devices and Instrumentation
Designing A Biomimetic Testing Platform For Actuators In A Series-Elastic Co-Contraction System, Ryan Tyler Schroeder
Designing A Biomimetic Testing Platform For Actuators In A Series-Elastic Co-Contraction System, Ryan Tyler Schroeder
UNLV Theses, Dissertations, Professional Papers, and Capstones
Actuators determine the performance of robotic systems at the most intimate of levels. As a result, much work has been done to assess the performance of different actuator systems. However, biomimetics has not previously been utilized as a pretext for tuning a series elastic actuator system with the purpose of designing an empirical testing platform. Thus, an artificial muscle tendon system has been developed in order to assess the performance of two distinct actuator types: (1) direct current electromagnetic motors and (2) ultrasonic rotary piezoelectric motors. Because the design of the system takes advantage of biomimetic operating principles such as …
Team Omnimouse, Derek J. Halman, Josh B. Porter, Steven A. Silver, Ian S. Stemper
Team Omnimouse, Derek J. Halman, Josh B. Porter, Steven A. Silver, Ian S. Stemper
Computer Engineering
INFORMATION, DATA, FIGURES AND DRAWINGS EMBODIED IN THIS DOCUMENT ARE STRICTLY CONFIDENTIAL AND ARE SUPPLIED ON THE UNDERSTANDING THAT THEY WILL NOT BE DISCLOSED TO THIRD PARTIES WITHOUT THE PRIOR WRITTEN CONSENT OF QUALITY OF LIFE PLUS.
Independent Component Analysis Enhancements For Source Separation In Immersive Audio Environments, Yue Zhao
Independent Component Analysis Enhancements For Source Separation In Immersive Audio Environments, Yue Zhao
Theses and Dissertations--Electrical and Computer Engineering
In immersive audio environments with distributed microphones, Independent Component Analysis (ICA) can be applied to uncover signals from a mixture of other signals and noise, such as in a cocktail party recording. ICA algorithms have been developed for instantaneous source mixtures and convolutional source mixtures. While ICA for instantaneous mixtures works when no delays exist between the signals in each mixture, distributed microphone recordings typically result various delays of the signals over the recorded channels. The convolutive ICA algorithm should account for delays; however, it requires many parameters to be set and often has stability issues. This thesis introduces the …
A Wireless And Digital Electrode Bus Topology For Biopotential Measurement, Mark Nolan, Edward Burke, Eugene Coyle
A Wireless And Digital Electrode Bus Topology For Biopotential Measurement, Mark Nolan, Edward Burke, Eugene Coyle
Conference Papers
The conventional biopotential measurement configuration utilises long lead wires which connect measuring electrodes to signal conditioning circuitry. The majority of bioelectric signals that are measured from the human body have a tiny signal amplitude (5µV-5mV range) and thus any interference that is induced on the lead wires can have a detrimental effect on the original signal. In this paper, we present an alternative configuration, in which digitisation occurs on the electrode, potentially providing enhanced signal measurement as well as significant benefits in terms of the simplification of the physical interconnections between electrodes. Multiple electrodes are combined to form a digital …
Polygrasp: Reach; Myoelectric Prosthetic Hand Iteration, Devon Patrick Augustus, Mighells Blaed Deuel, Ian Noel Fraser, Nicholas Philip Moesser
Polygrasp: Reach; Myoelectric Prosthetic Hand Iteration, Devon Patrick Augustus, Mighells Blaed Deuel, Ian Noel Fraser, Nicholas Philip Moesser
Mechanical Engineering
Amputations are a common occurrence in soldiers returning home who have suffered the effects of IED and munitions explosions. For upper limb amputees, trans-radial amputations are the most common. Traditional hook devices do not offer an adequate level of normalcy for users, prompting the use of myoelectric devices. While current myoelectric devices do offer a more natural experience, they come with a host of other problems that makes their adoption by service personnel not desirable or not permitted by the VA. PolyGrasp Reach seeks to reduce weight and cost and improve performance. This addresses several of the issues with devices …
The Presence Of Regional Accents In Electrolarynx Speech And The Resultant Effect On Overall Intelligibility., Brian Madden, Eugene Coyle
The Presence Of Regional Accents In Electrolarynx Speech And The Resultant Effect On Overall Intelligibility., Brian Madden, Eugene Coyle
Conference Papers
During voiced speech, the larynx provides quasi-periodic acoustic excitation of the vocal tract. In most electrolarynxes, mechanical vibrations are produced by a linear electromechanical actuator, the armature of which percusses against a metal or plastic plate at a frequency within the range of glottal excitation. In this paper, a phonological analysis of a section of results from an online perceptual intelligibility test was performed which compared speech produced using a novel hands-free electrolarynx and a commercially available electrolarynx. A portion of the test consisted of a closed-set format containing a selection of four sets of four random CVC audio samples …
Cyberknife Radiation Modeling: Effects Of Relaxed Translational And Rotational Constraints On Healthy Tissue Irradiation, Sudha Bhavaroop Potineni
Cyberknife Radiation Modeling: Effects Of Relaxed Translational And Rotational Constraints On Healthy Tissue Irradiation, Sudha Bhavaroop Potineni
Electrical & Computer Engineering Theses & Dissertations
The Cyberknife system is a robotic radio surgery instrument that is used to treat cancers in different parts of the human body. Because of its accuracy and precision, it has become one of the best radio surgery systems in the world. However, even with Cyberknife the treatment time for one session takes from 30 minutes up to 120 minutes depending on the size, shape, and position of the tumor in the human body. In this research, a solution is presented to aid in reducing this long treatment time. An algorithm is developed which simulates the amount of the healthy tissue …
Detection Of Breathing And Infant Sleep Apnea, Brian Berg
Detection Of Breathing And Infant Sleep Apnea, Brian Berg
Computer Engineering
Sleep apnea is a condition where people pause while breathing in their sleep; this can be of great concern for infants and premature babies. Current monitoring systems either require physical attachment to a user or may be unreliable. This project is meant to develop a device that can accurately detect breathing through sound and issue appropriate warnings upon its cessation. The device produced is meant to be a standalone device and thus was developed as an embedded systems project on a Xilinx Spartan 6 FPGA.
Universal Engineering Programmer – An In-House Development Tool For Developing And Testing Implantable Medical Devices In St. Jude Medical, Khoa Tat Do
Master's Theses
During development and testing of the functionality of the pacemaker and defibrillator device, engineers in the St. Jude Medical Cardiac Rhythm Management Division use an in-house development tool called Universal Engineering Programmer (UEP) to ensure the device functions as expected, before it can be used to test on an animal or a human during the implantation process. In addition, some applications of UEP are incorporated into the official releases of the device product. UEP has been developed and used by engineers across departments in the St. Jude Medical Cardiac Rhythm Management Division (CRMD). This thesis covers the flexible and reusable …
Intelligibility Of Electrolarynx Speech Using A Novel Hands-Free Actuator, Brian Madden, Mark Nolan, Ted Burke, James Condron, Eugene Coyle
Intelligibility Of Electrolarynx Speech Using A Novel Hands-Free Actuator, Brian Madden, Mark Nolan, Ted Burke, James Condron, Eugene Coyle
Conference Papers
During voiced speech, the larynx provides quasi-periodic acoustic excitation of the vocal tract. In most electrolarynxes, mechanical vibrations are produced by a linear electromechanical actuator, the armature of which percusses against a metal or plastic plate at a frequency within the range of glottal excitation. In this paper, the intelligibility of speech produced using a novel hands-free actuator is compared to speech produced using a conventional electrolarynx. Two able-bodied speakers (one male, one female) performed a closed response test containing 28 monosyllabic words, once using a conventional electrolarynx and a second time using the novel design. The resulting audio recordings …
Augmented Control Of A Hands-Free Electrolarynx, Brian Madden, James Condron, Eugene Coyle
Augmented Control Of A Hands-Free Electrolarynx, Brian Madden, James Condron, Eugene Coyle
Conference Papers
During voiced speech, the larynx acts as the sound source, providing a quasi-periodic excitation of the vocal tract. Following a total laryngectomy, some people speak using an electrolarynx which employs an electromechanical actuator to perform the excitatory function of the absent larynx. Drawbacks of conventional electrolarynx designs include the monotonic sound emitted, the need for a free-hand to operate the device, and the difficulty experienced by many laryngectomees in adapting to its use. One improvement to the electrolarynx, which clinicians and users frequently suggest, is the provision of a convenient hands-free control facility. This would allow more natural use of …
On Improving Electrooculogram-Based Computer Mouse Systems: The Accelerometer Trigger, Johnalan Keegan, Edward Burke, James Condron, Eugene Coyle
On Improving Electrooculogram-Based Computer Mouse Systems: The Accelerometer Trigger, Johnalan Keegan, Edward Burke, James Condron, Eugene Coyle
Conference Papers
Eye tracking is a well-established method of computer control for profoundly paralysed people (Anson et al., 2002). Cameras are commonly used to track eye movements (Morimoto et al., 2005) but one alternative is the bioelectrical signal known as the electrooculogram (EOG). There are some EOG mouse control systems that facilitate the use of GUI applications, but certain actions, which are straightforward using a conventional mouse, remain impossible. Unless the eyes are tracking a target, they move in saccades (jumps), making it impossible to voluntarily trace out smooth trajectories with one's gaze, as would be required to draw a smooth curve. …
Towards Supervised Autonomous Task Completion Using An In Vivo Surgical Robot, Jason J. Dumpert
Towards Supervised Autonomous Task Completion Using An In Vivo Surgical Robot, Jason J. Dumpert
Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research
Laparoscopy is a minimally invasive alternative to traditional abdominal surgery. Unlike traditional surgery, a laparoscopic procedure can be completed using small incisions. The use of these small incision results in reduced pain to the patient, shorter recovery times, and less trauma to skin, muscle and other tissues. However, these benefits to the patient are offset by the increased difficulty to the surgeon performing the procedure. These difficulties include reduced dexterity, reduced perception, and longer procedure times. The use of small in vivo robotic devices in minimally invasive surgery is one possible solution to these problems. The movement of these devices …
An Investigation Of The Use Of A High Resolution Adc As A Digital Biopotential Amplifier, Damon Berry, Frank Duignan, Richard Hayes
An Investigation Of The Use Of A High Resolution Adc As A Digital Biopotential Amplifier, Damon Berry, Frank Duignan, Richard Hayes
Conference Papers
Sigma delta analogue to digital converters have been used in many signal processing applications including some commercially available systems for sampling of bio-signals Bio-potential amplifiers have traditionally utilised specialised highquality analogue components to amplify bio-signals.
The central aim of this work is to investigate the benefits of using high-resolution sigma delta conversion as a digital amplification stage in the signal path of a bio-potential amplifier. A number of system arrangements specific to bio-potential measurement are presented and discussed. These arrangements are designed to use the high resolution capacity of the sigma delta converter in different ways, providing different benefits. To …
A Mobile Ecg Monitoring System With Context Collection, Jin Peng Li, Damon Berry, Richard Hayes
A Mobile Ecg Monitoring System With Context Collection, Jin Peng Li, Damon Berry, Richard Hayes
Conference Papers
Preventative health management represents a shift from the traditional approach of reactive treatment-based healthcare towards a proactive wellness-management approach where patients are encouraged to stay healthy with expert support when they need it, at any location and any time. This work represents a step along the road towards proactive, preventative healthcare for cardiac patients. It seeks to develop a smart mobile ECG monitoring system that requests and records context information about what is happening around the subject when an arrhythmia event occurs. Context information about the subject’s activities of daily living will, it is hoped, provide an enriched data set …