Open Access. Powered by Scholars. Published by Universities.®

Biomechanics and Biotransport Commons

Open Access. Powered by Scholars. Published by Universities.®

Medicine and Health Sciences

Institution
Keyword
Publication Year
Publication
Publication Type
File Type

Articles 91 - 106 of 106

Full-Text Articles in Biomechanics and Biotransport

Generation And Delivery Of Charged Aerosols To Infant Airways, Landon T. Holbrook Jan 2015

Generation And Delivery Of Charged Aerosols To Infant Airways, Landon T. Holbrook

Theses and Dissertations

The administration of pharmaceutical aerosols to infants on mechanical ventilation needs to be improved by increasing the efficiency of delivery devices and creating better ways of evaluating potential therapies. Aerosolized medicines such as surfactants have been administered to ventilated infants with mixed results, but studies have shown improvement in respiratory function with a much lower dose than with liquid instillation through an endotracheal tube (ETT). An aerosolized medicine must be transported through the ventilation tubing and deposit in the lungs to have the desired therapeutic response.

This work has taken a systematic approach to (i) develop new devices for the …


Computational Modeling To Assess Surgical Procedures For The Treatment Of Adult Acquired Flatfoot Deformity, Brian A. Smith Jan 2015

Computational Modeling To Assess Surgical Procedures For The Treatment Of Adult Acquired Flatfoot Deformity, Brian A. Smith

Theses and Dissertations

Several surgically corrective procedures are considered to treat Adult Acquired Flatfoot Deformity (AAFD) patients, relieve pain, and restore function. Procedure selection is based on best practices and surgeon preference. Recent research created patient specific models of Adult Acquired Flatfoot Deformity (AAFD) to explore their predictive capabilities and examine effectiveness of the surgical procedure used to treat the deformity. The models’ behavior was governed solely by patient bodyweight, soft tissue constraints, and joint contact without the assumption of idealized joints. The current work expanded those models to determine if an alternate procedure would be more effective for the individual. These procedures …


Evaluation Of The Anterior Talofibular And Calcaneofibular Ligament In Relation To Supination Ankle Sprains, Peter Tran Jun 2013

Evaluation Of The Anterior Talofibular And Calcaneofibular Ligament In Relation To Supination Ankle Sprains, Peter Tran

Biomedical Engineering

Ankle injuries have always posed an issue to a number of athletes. Sports that involve running and jumping accumulate about 25% of injuries correlating to ankle sprains. In most ankle sprains the inversion (supination) of the ankle cause damage to lateral ligaments. The two most common lateral ligaments to experience damage are the anterior talofibular (ATFL) and calcaneofibular (CFL) ligaments. The methods of taping and ankle braces have allowed athletes to prevent recurring sprains from occurring. However, sprains can still occur even when one or both methods are applied. The purpose of each method is to restrict the range of …


The Effects Of Hydrostatic Pressure On Early Endothelial Tubulogenic Processes, Ryan M. Underwood Jan 2013

The Effects Of Hydrostatic Pressure On Early Endothelial Tubulogenic Processes, Ryan M. Underwood

Theses and Dissertations--Biomedical Engineering

The effects of mechanical forces on endothelial cell function and behavior are well documented, but have not been fully characterized. Specifically, fluid pressure has been shown to elicit physical and chemical responses known to be involved in the initiation and progression of endothelial cell-mediated vascularization. Central to the process of vascularization is the formation of tube-like structures. This process—tubulogenesis—is essential to both the physiological and pathological growth of tissues. Given the known effects of pressure on endothelial cells and its ubiquitous presence in the vasculature, we investigated pressure as a magnitude-dependent parameter for the regulation of endothelial tubulogenic activity. To …


The Use Of A Pylon Mounted Transducer For Investigating The Gait Of Transtibial Amputees, Justin Robert Brink May 2012

The Use Of A Pylon Mounted Transducer For Investigating The Gait Of Transtibial Amputees, Justin Robert Brink

UNLV Theses, Dissertations, Professional Papers, and Capstones

Two areas of research interest in the design and use of lower limb prosthetic devices are how foot performance varies with design and how prosthesis alignment affects gait. The current study addressed both of these areas through the use of the JR3 triaxial transducer mounted at the base of the socket. The transducer is an innovative form of instrumentation that measures forces and moments at the end of the socket. Traditional measurement of gait uses a force plate buried in the floor of a gait laboratory. The study established that the transducer offers a viable means of instrumentation for amputee …


Automation Of Orthodontic Wire Tester For Performing Three Point Bending Tests, Adithya Venkatesan Aug 2011

Automation Of Orthodontic Wire Tester For Performing Three Point Bending Tests, Adithya Venkatesan

Master's Theses

Abstract

Understanding the biomechanical factors in orthodontics is important in order to improve the overall effectiveness of actual clinical treatment. An accurate method to study the threedimensional (3D) force systems and the resulting movements of teeth during orthodontic treatment is needed along with the understanding of the material properties of any orthodontic wire. Until recently, most of the orthodontic biomechanics literature was limited to twodimensional experimental studies. Recent advances in threedimensional computer modeling have also been developed but have been limited to the manual control of tooth movement. Overall, there is very little published evidence in the literature on the …


The Use Of Motion Analysis Technology As An Alternative Means Of Assessing Spinal Deformity In Patients With Adolescent Idiopathic Scoliosis, Matthew J. Solomito May 2011

The Use Of Motion Analysis Technology As An Alternative Means Of Assessing Spinal Deformity In Patients With Adolescent Idiopathic Scoliosis, Matthew J. Solomito

Master's Theses

Adolescent Idiopathic Scoliosis (AIS) is a three dimensional deformity of the spine that causes abnormal curvatures in the coronal and sagittal planes and abnormal vertebral rotations. The gold standard for diagnosing and tracking the progression of the deformity is through the use of repeated radiography and a patient can receive upwards of fifteen radiographic series over the course of treatment, which exposes this population to an increased risk of radiation-dependent complications.

This thesis presents the necessary calculations and the marker set required to make the motion capture technology a viable alternative to radiographs, in an effort to reduce the patient’s …


Custom-Molded Foot-Orthosis Intervention And Multisegment Medial Foot Kinematics During Walking, Mark Geil Jan 2011

Custom-Molded Foot-Orthosis Intervention And Multisegment Medial Foot Kinematics During Walking, Mark Geil

Faculty Articles

No abstract provided.


An Investigation Of Humeral Stress Fractures In Racing Thoroughbreds Using A 3d Finite Element Model In Conjunction With A Bone Remodeling Algorithm, Ryan James Moore Feb 2010

An Investigation Of Humeral Stress Fractures In Racing Thoroughbreds Using A 3d Finite Element Model In Conjunction With A Bone Remodeling Algorithm, Ryan James Moore

Master's Theses

The humerus of a racing horse Thoroughbred is highly susceptible to stress fractures at a characteristic location as a result of cyclic loading. The propensity of a Thoroughbred to exhibit humeral fracture has made equines useful models in the epidemiology of stress fractures. In this study, a racing Thoroughbred humerus was simulated during training using a 3D finite element model in conjunction with a bone remodeling algorithm. Nine muscle forces and two contact forces were applied to the 3-dimensional finite element model, which contains four separate load cases representing fore-stance, mid-stance, aft-stance, and standing. Four different training programs were incorporated …


Trunk Response Analysis Under Sudden Forward Perturbations Using A Kinematics-Driven Model, B. Bazrgari, A. Shirazi-Adl, Christian Larivière Jan 2009

Trunk Response Analysis Under Sudden Forward Perturbations Using A Kinematics-Driven Model, B. Bazrgari, A. Shirazi-Adl, Christian Larivière

Études primaires

No abstract provided.


An Approach To Identifying The Biomechanical Differences Between Intercostal Cartilage In Subjects With Pectus Excavatum And Normals In Vivo: Reconstruction And Ct Registration, Zhenzhen Yan Apr 2008

An Approach To Identifying The Biomechanical Differences Between Intercostal Cartilage In Subjects With Pectus Excavatum And Normals In Vivo: Reconstruction And Ct Registration, Zhenzhen Yan

Electrical & Computer Engineering Theses & Dissertations

Pectus excavatum (PE) is a congenital chest wall deformity affecting the ribs and sternum and exhibiting a concave appearance in the anterior chest wall. In this thesis, we describe a study to investigate in vivo differences in the pectus excavatum rib cage and outline steps using normals and pectus patients data in developing models and methods to be used in carrying out the study. We propose methods to develop reconstructed models in order to enable proper registration between data collection points (DCPs) on the 3D CT rib cage model and CT skin surface model and registration between CT surrogate models …


Energy Loss And Stiffness Properties Of Dynamic Elastic Response Prosthetic Feet, Mark Geil Jan 2001

Energy Loss And Stiffness Properties Of Dynamic Elastic Response Prosthetic Feet, Mark Geil

Faculty Articles

No abstract provided.


New In Vivo And In Vitro Techniques For Quantification Of Lateral Force Levels That Cause Implants To Fail : A Progress Report On Monkey Research, V. Leroy Leggitt Jun 1992

New In Vivo And In Vitro Techniques For Quantification Of Lateral Force Levels That Cause Implants To Fail : A Progress Report On Monkey Research, V. Leroy Leggitt

Loma Linda University Electronic Theses, Dissertations & Projects

Two new techniques for quantification of forces generated by an expansion screw apparatus placed between pairs of cylindrical endosseous titanium implants are described, along with preliminary data gained from their use in Macaca rhesus monkeys. Strain gages were bonded to the expansion apparatus and were calibrated either directly by micro load cell, or indirectly by Instron Machine to reflect the applied force.

Immediate loads of up to 6 kilograms have been applied to the implants with no increase in mobility as verified by a Periotest device. No previous studies on the orthodontic uses of implants have evaluated in vivo forces …


A Comparative Analysis Of Intrusion Of Incisor Teeth Achieved In Adults And Children According To Facial Type, Ronald L. Otto Jun 1979

A Comparative Analysis Of Intrusion Of Incisor Teeth Achieved In Adults And Children According To Facial Type, Ronald L. Otto

Loma Linda University Electronic Theses, Dissertations & Projects

A comparison of incisor intrusion achieved in deep bite adults and children was made. Facial type was also examined for affect upon intrusion achieved. Fifty-five cases treated with Bioprogressive mechanics were studied cephalometrically, including twenty-four adults and thirty-one children. Neither age nor facial type was found to be statistically related to the amount of incisor intrusion achieved in this sample. A method of measuring intrusion at the root apices was devised which was felt to give a more accurate indication of actual bodily intrusion. More external root changes during treatment were observed for adults than for growing children. Wide latitude …


A Method Of Analyzing Mandibular Movement, Richard B. Mccoy Jun 1973

A Method Of Analyzing Mandibular Movement, Richard B. Mccoy

Loma Linda University Electronic Theses, Dissertations & Projects

Mandibular movement is considered to be a fundamental factor in the study, analysis, and treatment of occlusion. For many years, dentists have realized that dental health depends upon the compatibility of mandibular movements and occlusion. This realization has led to the development of new methods and techniques for recording accurately and scientifically the movements of the mandible. In order for this data to be of scientific value, it must be stored in a usable form which is easily available for analysis.

The purpose of this research project was to develop a procedure for storing and recalling mandibular-movement information. Before such …


A Procedure For The Measurement Of Glosso-Maxillary Forces, Howard L. Lilly Jr. Jun 1966

A Procedure For The Measurement Of Glosso-Maxillary Forces, Howard L. Lilly Jr.

Loma Linda University Electronic Theses, Dissertations & Projects

The purpose of this investigation was to develop a clinically feasible procedure for recording the magnitudes of glosso-maxillary forces at four palatal loci using an electronic transducer system described by Lear et, al. (1965). Of particular interest was the development of a convenient and accurate calibration device for both intraoral and extraoral application. A further object of interest was the effect an acrylic carrier plate might introduce to the magnitude of force response. Finally whether or not any significant adaptation to the carrier plate or to the transducers occurs during a reasonable testing period (six to seven hours).

A calibration …