A Three Constituent Mixture Theory Model Of Cutaneous And Subcutaneous Tissue In The Context Of Neonatal Pressure Ulcer Etiology And Prevention, Anne Dye Zakrajsek Apr 2015

A Three Constituent Mixture Theory Model Of Cutaneous And Subcutaneous Tissue In The Context Of Neonatal Pressure Ulcer Etiology And Prevention, Anne Dye Zakrajsek

Open Access Dissertations

Localized ischemia, impaired interstitial fluid flow, and sustained mechanical loading of cells have all been hypothesized as mechanisms of pressure ulcer (PrU) etiology. Time-varying loading has experimentally been shown to increase fluid flow in human skin in vivo. Towards the design of prophylactic protocols and treatment modalities for PrU management there is a need for an analytical model to investigate the local fluid flow characteristics of skin tissue under time-varying loading. In this study, a triphasic mixture theory model with constituents of extracellular matrix, interstitial fluid, and blood was calibrated and validated and used to investigate stress and fluid velocity …


Computational Modeling Of Cardiac Biomechanics, Amir Nikou Jan 2015

Computational Modeling Of Cardiac Biomechanics, Amir Nikou

Theses and Dissertations--Mechanical and Aerospace Engineering

The goal of this dissertation was to develop a realistic and patient-specific computational model of the heart that ultimately would help medical scientists to better diagnose and treat heart diseases. In order to achieve this goal, a three dimensional finite element model of the heart was created using magnetic resonance images of the beating pig heart. This model was loaded by the pressure of blood inside the left ventricle which was measured by synchronous catheterization. A recently developed structurally based constitutive model of the myocardium was incorporated in the finite element solver to model passive left ventricular myocardium. Additionally, an …


Morphology Of Brain Sulci Trabeculae And Its Effect On Brain During Impacts, Sharlin Anwar Jan 2015

Morphology Of Brain Sulci Trabeculae And Its Effect On Brain During Impacts, Sharlin Anwar

Dissertations and Theses

Traumatic brain injury (TBI) is an intracranial injury caused by direct contact or non-contact head impacts to the brain. TBI is a major problem that accounts for high incidents of hospitalizations each year. Thus, it is important to understand and predict the occurrence of TBI in an impact. It has been shown that the subarachnoid space (SAS) trabeculae play an important role in damping the effect of an impact, thus reducing the injuries. However, the influence of sulci parameters and the sulci trabeculae in TBI due to impact is unexplored. Studies have shown that inclusion of sulci in brain models …


Mechanical Impedance Of Ankle As A Function Of Electromyography Signals Of Lower Leg Muscles Using Artificial Neural Network, Chen Jia Jan 2015

Mechanical Impedance Of Ankle As A Function Of Electromyography Signals Of Lower Leg Muscles Using Artificial Neural Network, Chen Jia

Dissertations, Master's Theses and Master's Reports - Open

This paper reports on the feasibility of developing a model to describe the nonlinear relationship between the mechanical impedance of the human ankle within a specified range of frequency and the root mean square (RMS) value of the Electromyography (EMG) signals of the muscles of human ankle using Artificial Neural Network (ANN). A lower extremity rehabilitation robot — Anklebot was used to apply pseudo-random mechanical perturbations to the ankle and measure the angular displacement of the ankle to estimate the data of ankle mechanical impedance. Meanwhile, the surface EMG signals from the selected muscles were monitored and recorded using a …


Generation And Delivery Of Charged Aerosols To Infant Airways, Landon T. Holbrook Jan 2015

Generation And Delivery Of Charged Aerosols To Infant Airways, Landon T. Holbrook

Theses and Dissertations

The administration of pharmaceutical aerosols to infants on mechanical ventilation needs to be improved by increasing the efficiency of delivery devices and creating better ways of evaluating potential therapies. Aerosolized medicines such as surfactants have been administered to ventilated infants with mixed results, but studies have shown improvement in respiratory function with a much lower dose than with liquid instillation through an endotracheal tube (ETT). An aerosolized medicine must be transported through the ventilation tubing and deposit in the lungs to have the desired therapeutic response.

This work has taken a systematic approach to (i) develop new devices for the …


Computational Modeling To Assess Surgical Procedures For The Treatment Of Adult Acquired Flatfoot Deformity, Brian A. Smith Jan 2015

Computational Modeling To Assess Surgical Procedures For The Treatment Of Adult Acquired Flatfoot Deformity, Brian A. Smith

Theses and Dissertations

Several surgically corrective procedures are considered to treat Adult Acquired Flatfoot Deformity (AAFD) patients, relieve pain, and restore function. Procedure selection is based on best practices and surgeon preference. Recent research created patient specific models of Adult Acquired Flatfoot Deformity (AAFD) to explore their predictive capabilities and examine effectiveness of the surgical procedure used to treat the deformity. The models’ behavior was governed solely by patient bodyweight, soft tissue constraints, and joint contact without the assumption of idealized joints. The current work expanded those models to determine if an alternate procedure would be more effective for the individual. These procedures …


Effects Of Hip And Ankle Moments On Running Stability: Simulation Of A Simplified Model, Rubin C. Cholera Oct 2014

Effects Of Hip And Ankle Moments On Running Stability: Simulation Of A Simplified Model, Rubin C. Cholera

Open Access Theses

In human running, the ankle, knee, and hip moments are known to play different roles to influence the dynamics of locomotion. A recent study of hip moments and several hip-based legged robots have revealed that hip actuation can significantly improve the stability of locomotion, whether controlled or uncontrolled. Ankle moments are expected to also significantly affect running stability, but in a different way than hip moments. Here we seek to advance the current theory of dynamic running and associated legged robots by determining how simple open-loop ankle moments could affect running stability. We simulate a dynamical model, and compare it …


Understanding Preferred Leg Stiffness And Layered Control Strategies For Locomotion, Zhuohua H. Shen Oct 2014

Understanding Preferred Leg Stiffness And Layered Control Strategies For Locomotion, Zhuohua H. Shen

Open Access Dissertations

Despite advancement in the field of robotics, current legged robots still cannot achieve the kind of locomotion stability animals and humans have. In order to develop legged robots with greater stability, we need to better understand general locomotion dynamics and control principles. Here we demonstrate that a mathematical modeling approach could greatly enable the discovery and understanding of general locomotion principles. ^ It is found that animal leg stiffness when scaled by its weight and leg length falls in a narrow region between 7 and 27. Rarely in biology does such a universal preference exist. It is not known completely …


Application Of Limited Mixing In The Hele–Shaw Geometry In Fabrication Of Janus Hydrogels, Md Mahmudur Rahman Apr 2014

Application Of Limited Mixing In The Hele–Shaw Geometry In Fabrication Of Janus Hydrogels, Md Mahmudur Rahman

Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research

It is widely accepted that cells behave differently responding to the stiffness of their extracellular matrix (ECM). Such observations were made by culturing cells on hydrogel substrates of tunable stiffness. However, it was recently proposed that cells may sense how strongly they are tethered to ECM, not the local stiffness of ECM. To investigate both hypotheses, we developed a method to fabricate Janus polyacrylamide (PAAM) gels. We squeeze two drops of different concentrations in the Hele-Shaw geometry to generate radial Stokes flow. When the drops coalesce, limited mixing occurs at the interface due to the narrow confinement, and diffusion normal …


Subtalar Fusion Fixture Design And Test, Nathan Ortiz Apr 2014

Subtalar Fusion Fixture Design And Test, Nathan Ortiz

Honors Theses

Subtalar arthrodesis is performed when cartilage in the talo-calcaneal (the ankle) joint is degraded in a patient and there are multiple approaches to this surgery. Using synthetic bone material, fixtures were cast from aluminum, using the process of evaporation pattern casting, and epoxy. This casting was used to grip the calcaneus bone of the foot in order to load it mechanically, simulating different scenarios that would be encountered during walking. The relative displacement of the ankle joint was measured using a digital image correlation (DIC) program that was modified to work in both two- and three-dimensional space. This program can …


Hand Prosthesis, Tru Nguyen, Aaron Delano, Kyle M. Green, Jorge Maderal, Cody Poland Apr 2014

Hand Prosthesis, Tru Nguyen, Aaron Delano, Kyle M. Green, Jorge Maderal, Cody Poland

Thinking Matters Symposium Archive

This project deals with engineering students’ prosthetic hand design, submitted to the University of Southern Maine’s engineering department. The primary goal of the prosthetic hand design is to allow an impaired individual to grasp and hold everyday objects ranging from a toothbrush to a jug of milk. The project consists of three teams each designing their respective portion of the prosthetic device. The teams will deal with three specific design areas; computer aided design of the mechanism, electronic integration, and manufacturing implementation. The design team turns notebook doodles into virtual models in SolidWorks. The electronics team will control a battery …


Analysis And Modeling Of The Roles Of Actin-Myosin Interactions In Bladder Smooth Muscle Biomechanics, Seyed Omid Komariza Jan 2014

Analysis And Modeling Of The Roles Of Actin-Myosin Interactions In Bladder Smooth Muscle Biomechanics, Seyed Omid Komariza

Theses and Dissertations

Muscle mechanical behavior potentially plays an important role in some of the most common bladder disorders. These include overactive bladder, which can involve involuntary contractions during bladder filling, and impaired contractility or underactive bladder, which may involve weak or incomplete contractions during voiding. Actin-myosin cross-bridges in detrusor smooth muscle (DSM) are responsible for contracting and emptying the bladder. The total tension produced by muscle is the sum of its preload and active tensions. Studies suggest that actin-myosin cross-links are involved in adjustable preload stiffness (APS), which is characterized by a preload tension curve that can be shifted along the length …


Finite Element Models Of The Knee & Hip Joints: Using Opensim To Predict Muscle Forces, Kevin S. Jones, Spencer D. Wangerin, Jeffrey D. Pyle, Stephen M. Klisch, Scott J. Hazelwood Aug 2013

Finite Element Models Of The Knee & Hip Joints: Using Opensim To Predict Muscle Forces, Kevin S. Jones, Spencer D. Wangerin, Jeffrey D. Pyle, Stephen M. Klisch, Scott J. Hazelwood

STAR Program Research Presentations

Quantitative data of stresses and strains in the cartilage of the knee and hip joints are required to design prostheses and can be used to give accurate advice to patients with cartilage damage as to which activities should be avoided. Instrumented hip implants can only give the overall resultant force in the joint, not the stresses and strains throughout the cartilage. Finite Element (FE) models of the Knee and Hip are being constructed in order to obtain the stresses and strains in articular (of the joint) cartilage. Muscle forces and joint contact forces are required as inputs to these FE …


Design Of A Compliant Underactuated Robotic Finger With Coordinated Stiffness, Etienne Dessauw Aug 2013

Design Of A Compliant Underactuated Robotic Finger With Coordinated Stiffness, Etienne Dessauw

Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research

The concept of underactuation has been previously developed in the robotic field for grasping applications. For these anthropomorphic grippers, the minimization of the number of input signals, or in other words underactuation, is the most expected characteristic. This method has become very popular in recent decades. Indeed, by minimizing the number of input signals, it minimizes the complexity of the system’s control and at the same time avoids increased weight and cost. The inconvenience of such a technique is that the design of this type of system remains a difficult task if the behavior of the underactuated set of joints …


Subtalar Joint Instability: Diagnosis And Conservative Treatment, Julie Choisne Jul 2013

Subtalar Joint Instability: Diagnosis And Conservative Treatment, Julie Choisne

Mechanical & Aerospace Engineering Theses & Dissertations

Subtalar instability may be caused by various ligamentous injuries. Combined instability at the ankle and subtalar joint is not adequately diagnosed. Further, isolated subtalar instability is usually misdiagnosed which may lead to long term damage to the joint. Developing a non-invasive and clinically practical tool to diagnose subtalar joint instability would be an important asset. The ability of an ankle brace, a common treatment for hindfoot instability, to promote stability for the subtalar joint was not well established. The purposes of this study were to 1) assess the kinematics of the subtalar, ankle, and hindfoot in the presence of isolated …


Design And Development Of A Stair Ascension Assistive Device For Transfemoral Amputees, Casey Michael Barbarino Jun 2013

Design And Development Of A Stair Ascension Assistive Device For Transfemoral Amputees, Casey Michael Barbarino

Master's Theses

Transfemoral amputees around the world experience increased difficulty in climbing stairs due to lack of muscle, balance, and other factors. The loss of a lower limb greatly diminishes the amount of natural force generation provided that is necessary to propel oneself up stairs. This study investigated possible solutions to the problem of stair ascension for transfemoral amputees by the means of designing and developing an externally attachable device to a prosthesis. The number of amputations from military service has greatly increased since 2008, which shows there is a clear need for assistive devices (Wenke, Krueger, & Ficke, 2012). With the …


Distal Placement Of An End-To-Side Bypass Graft Anastomosis: A 3d Computational Study, John Di Cicco, Ayodeji Demuren Jan 2013

Distal Placement Of An End-To-Side Bypass Graft Anastomosis: A 3d Computational Study, John Di Cicco, Ayodeji Demuren

Mechanical & Aerospace Engineering Faculty Publications

A three-dimensional (3D) computational fluid dynamics study of shear rates around distal end-to-side anastomoses has been conducted. Three 51% and three 75% cross-sectional area-reduced 6 mm cylinders were modeled each with a bypass cylinder attached at a 30-degree angle at different placements distal to the constriction. Steady, incompressible, Newtonian blood flow was assumed, and the full Reynolds-averaged Navier-Stokes equations, turbulent kinetic energy, and specific dissipation rate equations were solved on a locally structured multiblock mesh with hexahedral elements. Consequently, distal placement of an end-to-side bypass graft anastomosis was found to have an influence on the shear rate magnitudes. For the …


Designing For Success: Developing Engineers Who Consider Universal Design Principles, Kimberly Edginton Bigelow Oct 2012

Designing For Success: Developing Engineers Who Consider Universal Design Principles, Kimberly Edginton Bigelow

Mechanical and Aerospace Engineering Faculty Publications

Engineers must design for a diverse group of potential users of their products; however, engineering curricula rarely include an emphasis on universal design principles. This research article details the effectiveness of a design project implemented in a first-year engineering course in an effort to raise awareness of the need for engineers to be more inclusive when designing. Students were asked to apply universal design principles to redesign an engineering laboratory to make it more usable to all, including individuals with disabilities who use the room. A representative from the university’s disability services staff, as well as individuals with first-hand experience …


Viscoelastic Anisotropic Finite Element Mixture Model Of Articular Cartilage Using Viscoelastic Collagen Fibers And Validation With Stress Relaxation Data, Matthew Alexander Griebel Jun 2012

Viscoelastic Anisotropic Finite Element Mixture Model Of Articular Cartilage Using Viscoelastic Collagen Fibers And Validation With Stress Relaxation Data, Matthew Alexander Griebel

Master's Theses

Experimental results show that collagen fibers exhibit stress relaxation under tension and a highly anisotropic distribution. To further develop the earlier model of Stender [1], the collagen constituent was updated to reflect its intrinsic viscoelasticity and anisotropic distribution, and integrated with an existing mixture model with glycosaminoglycans and ground substance matrix. A two-term Prony series expansion of the quasi-linear viscoelastic model was chosen to model the viscoelastic properties of the collagen fibers. Material parameters were determined by using the simplex method to minimize the sum of squared errors between model results and experimental stress relaxation data of tissue in tension. …


Hydraulically Driven Mechanical Representation Of A Biological System, Andrea Argouarch, Michael Mceachern, Brandon Parham Jun 2012

Hydraulically Driven Mechanical Representation Of A Biological System, Andrea Argouarch, Michael Mceachern, Brandon Parham

Biomedical Engineering

No abstract provided.


The Use Of A Pylon Mounted Transducer For Investigating The Gait Of Transtibial Amputees, Justin Robert Brink May 2012

The Use Of A Pylon Mounted Transducer For Investigating The Gait Of Transtibial Amputees, Justin Robert Brink

UNLV Theses, Dissertations, Professional Papers, and Capstones

Two areas of research interest in the design and use of lower limb prosthetic devices are how foot performance varies with design and how prosthesis alignment affects gait. The current study addressed both of these areas through the use of the JR3 triaxial transducer mounted at the base of the socket. The transducer is an innovative form of instrumentation that measures forces and moments at the end of the socket. Traditional measurement of gait uses a force plate buried in the floor of a gait laboratory. The study established that the transducer offers a viable means of instrumentation for amputee …


Electrokinetic Transport Phenomena In Nanofluidic Devices, Mingkan Zhang Apr 2012

Electrokinetic Transport Phenomena In Nanofluidic Devices, Mingkan Zhang

Mechanical & Aerospace Engineering Theses & Dissertations

Nanofluidic devices have wide potential applications in biology, chemistry and medicine, and have been proven to be very valuable in sensing biological particles (e.g., DNA and proteins) due to their efficiency, sensitivity and portability. Electrokinetic control of ion, fluid, and particle transport by using only electric field is the most popular method employed in nanofluidic devices. A comprehensive understanding of the electrokinetic ion, fluid, and particle transport in nanofluidics is essential for developing nanofluidic devices for the detection of single molecules, such as the next generation nanopore-based DNA sequencing technology. This research explored numerical simulation of electrokinetic ion and fluid …


Gas Embolic Factors In Cardiovascular Health, Eric L. Cutler Apr 2011

Gas Embolic Factors In Cardiovascular Health, Eric L. Cutler

Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research

Gas emboli are a clinical issue often encountered in the space exploration, marine construction, and medical fields.  Individuals involved with these disciplines will often have asympomatic gas emboli circulating throughout their bodies on a regular basis.  A study into the impact of chronic asymptomatic gas emboli on the risk of atherosclerosis in humans is thus presented.  This research utilized a custom built cardiovascular flow simulator and accompanying data acquisition system to experimentally determine the influence of gas emboli under varied circumstances on the mean wall shear stress of a tube in-vitro.  A directly inverse relationship between gas embolus presence in …


Ultrasonic And Stereo-Optical Characterization Techniques For Applications In Mechanical Testing, Jonathan M. Hein Apr 2011

Ultrasonic And Stereo-Optical Characterization Techniques For Applications In Mechanical Testing, Jonathan M. Hein

Department of Engineering Mechanics: Dissertations, Theses, and Student Research

This thesis considers methods developed based on ultrasonic reflections from interfaces and stereo-optical surface strain measurements to study the mechanical characterization of materials and bodies. The ultrasonic method is used to characterize wave speed and attenuation for highly attenuating samples. The stereo-optical strain measurements are used to characterize the effects of genes on mechanical properties of bone, and the dynamic characterization of blast waves in the UNL Shock Wave Trauma Mechanics facility.

A method is described and developed for characterizing the wave speed and attenuation spectrums from reflected waves from the contact surface with an unknown material. The method is …


Estimation Of The Centre Of Mass From Motion Capture And Force Plate Recordings: A Study On The Elderly, Sebastien Cotton, Michele Vanoncini, Philippe Fraisse, Nacim Ramdani, Emel Demircan, Andrew P. Murray, Thierry Keller Jan 2011

Estimation Of The Centre Of Mass From Motion Capture And Force Plate Recordings: A Study On The Elderly, Sebastien Cotton, Michele Vanoncini, Philippe Fraisse, Nacim Ramdani, Emel Demircan, Andrew P. Murray, Thierry Keller

Mechanical and Aerospace Engineering Faculty Publications

The estimation of the centre of mass position in humans is usually based on biomechanical models developed from anthropometric tables. This method can potentially introduce errors in studies involving elderly people, since the ageing process is typically associated with a modification of the distribution of the body mass. In this paper, an alternative technique is proposed, and evaluated with an experimental study on 9 elderly volunteers. The technique is based on a virtual chain, identified from experimental data and locating the subject's centre of mass. Its configuration defines the location of the centre of mass, and is a function of …


Personal Navigation Via High-Resolution Gait-Corrected Inertial Measurement Units, Özkan Bebek, Michael A. Suster, Srihari Rajgopal, Michael J. Fu, Xuemei Huang, M. Cenk Çavu¸So˘Glu,, Darrin J. Young, Mehran Mehregany, Antonie J. Van Den Bogert, Carlos H. Mastrangelo Nov 2010

Personal Navigation Via High-Resolution Gait-Corrected Inertial Measurement Units, Özkan Bebek, Michael A. Suster, Srihari Rajgopal, Michael J. Fu, Xuemei Huang, M. Cenk Çavu¸So˘Glu,, Darrin J. Young, Mehran Mehregany, Antonie J. Van Den Bogert, Carlos H. Mastrangelo

Mechanical Engineering Faculty Publications

In this paper, a personal micronavigation system that uses high-resolution gait-corrected inertial measurement units is presented. The goal of this paper is to develop a navigation system that uses secondary inertial variables, such as velocity, to enable long-term precise navigation in the absence of Global Positioning System (GPS) and beacon signals. In this scheme, measured zerovelocity duration from the ground reaction sensors is used to reset the accumulated integration errors from accelerometers and gyroscopes in position calculation. With the described system, an average position error of 4 m is achieved at the end of half-hour walks.


An Investigation Of Humeral Stress Fractures In Racing Thoroughbreds Using A 3d Finite Element Model In Conjunction With A Bone Remodeling Algorithm, Ryan James Moore Feb 2010

An Investigation Of Humeral Stress Fractures In Racing Thoroughbreds Using A 3d Finite Element Model In Conjunction With A Bone Remodeling Algorithm, Ryan James Moore

Master's Theses

The humerus of a racing horse Thoroughbred is highly susceptible to stress fractures at a characteristic location as a result of cyclic loading. The propensity of a Thoroughbred to exhibit humeral fracture has made equines useful models in the epidemiology of stress fractures. In this study, a racing Thoroughbred humerus was simulated during training using a 3D finite element model in conjunction with a bone remodeling algorithm. Nine muscle forces and two contact forces were applied to the 3-dimensional finite element model, which contains four separate load cases representing fore-stance, mid-stance, aft-stance, and standing. Four different training programs were incorporated …


Nonequilibrium Thermodynamics Modeling Of Coupled Biochemical Cycles In Living Cells, Yaşar Demirel Jan 2010

Nonequilibrium Thermodynamics Modeling Of Coupled Biochemical Cycles In Living Cells, Yaşar Demirel

Yaşar Demirel Publications

Living cells represent open, nonequilibrium, self organizing, and dissipative systems maintained with the continuous supply of outside and inside material, energy, and information flows. The energy in the form of adenosine triphosphate is utilized in biochemical cycles, transport processes, protein synthesis, reproduction, and performing other biological work. The processes in molecular and cellular biological systems are stochastic in nature with varying spatial and time scales, and bounded with conservation laws, kinetic laws, and thermodynamic constraints, which should be taken into account by any approach for modeling biological systems. In component biology, this review focuses on the modeling of enzyme kinetics …


Mechanical Simulation Of Articular Cartilage Based On Experimental Results, Kevin Matthew Stewart Jun 2009

Mechanical Simulation Of Articular Cartilage Based On Experimental Results, Kevin Matthew Stewart

Master's Theses

Recently, a constituent based cartilage growth finite element model (CGFEM) was developed in order to predict articular cartilage (AC) biomechanical properties before and after growth. Previous research has noted limitations in the CGFEM such as model convergence with growth periods greater than 12 days. The main aims of this work were to address these limitations through (1) implementation of an exact material Jacobian matrix definition using the Jaumann-Kirchhoff (J-K) method and (2) quantification of elastic material parameters based upon research findings of the Cal Poly Cartilage Biomechanics Group (CPGBG). The J-K method was successfully implemented into the CGFEM and exceeded …


Milking Machine Efficiency And Shed Husbandry Practices, G R. Olney Jan 1965

Milking Machine Efficiency And Shed Husbandry Practices, G R. Olney

Journal of the Department of Agriculture, Western Australia, Series 4

MILKING machine efficiency on dairy farms in the Bridgetown, Greenbushes, Balingup, Boyup Brook and Nannup areas was the subject of a recent testing survey.

During the survey 106 machines were tested and the results assessed statistically to gauge the general level of machine efficiency in these districts.