Open Access. Powered by Scholars. Published by Universities.®
Bioelectrical and Neuroengineering Commons™
Open Access. Powered by Scholars. Published by Universities.®
- Discipline
-
- Anatomy (5)
- Cells (5)
- Life Sciences (5)
- Medicine and Health Sciences (5)
- Biochemistry, Biophysics, and Structural Biology (3)
-
- Biochemistry (2)
- Biophysics (2)
- Cell and Developmental Biology (2)
- Molecular Biology (2)
- Amino Acids, Peptides, and Proteins (1)
- Cancer Biology (1)
- Cell Biology (1)
- Chemicals and Drugs (1)
- Chemistry (1)
- Gastroenterology (1)
- Hemic and Immune Systems (1)
- Medical Specialties (1)
- Molecular, Cellular, and Tissue Engineering (1)
- Nanoscience and Nanotechnology (1)
- Physical Sciences and Mathematics (1)
- Tissues (1)
Articles 1 - 7 of 7
Full-Text Articles in Bioelectrical and Neuroengineering
Peculiarities Of Phosphatidylserine Externalization By Nano- And Microsecond Electric Pulses, Mantas Silkunas, Alayna Enos, Iurii Semenov, Giedre Silkuniene, Eleni Zivla, Olga N. Pakhomova, Andrei G. Pakhomov
Peculiarities Of Phosphatidylserine Externalization By Nano- And Microsecond Electric Pulses, Mantas Silkunas, Alayna Enos, Iurii Semenov, Giedre Silkuniene, Eleni Zivla, Olga N. Pakhomova, Andrei G. Pakhomov
Bioelectrics Publications
Phosphatidylserine (PS) externalization is a hallmark of apoptosis but can also be triggered within seconds by pulsed electric fields (PEFs). Whether PS reaches the outer leaflet by lateral migration through electropores or indirectly through Ca²+-dependent signaling and scramblase activation remains debated. We used total internal reflection fluorescence (TIRF) microscopy with Annexin V-Alexa Fluor 568 and/or bovine lactadherin-FITC to resolve PS externalization in HEK293 cells placed on an indium tin oxide (ITO) transparent electrode. PEF exposures produced discrete PS-positive puncta ("freckles") within ~ 10 s after a 20-µs pulse (1.2-2.5 kV/cm) or with a ~ 1-min delay after a …
Dynamics Of Cell Membrane Lesions And Adaptive Conductance Under The Electrical Stress, Mantas Silkunas, Olga N. Pakhomova, Giedre Silkuniene, Andrei G. Pakhomov
Dynamics Of Cell Membrane Lesions And Adaptive Conductance Under The Electrical Stress, Mantas Silkunas, Olga N. Pakhomova, Giedre Silkuniene, Andrei G. Pakhomov
Bioelectrics Publications
Exceeding physiological limits of the cell membrane potential compromises structural integrity, enabling the passage of normally impermeant solutes and disrupting cell function. Electropermeabilization has been studied extensively at the cellular scale, but not at the individual membrane lesion level. We employed fast total internal reflection fluorescence (TIRF) imaging of Ca(2+) entry transients to discern individual lesions in a hyperpolarized cell membrane and characterize their focality, thresholds, electrical conductance, and the lifecycle. A diffuse and momentary membrane permeabilization without a distinct pore formation was observed already at a -100 mV threshold. Polarizing down to -200 mV created focal pores with a …
Control Of The Electroporation Efficiency Of Nanosecond Pulses By Swinging The Electric Field Vector Direction, Vitalii Kim, Iurii Semenov, Allen S. Kiester, Mark A. Keppler, Bennett L. Ibey, Joel N. Bixler, Ruben M. L. Colunga Biancatelli, Andrei G. Pakhomov
Control Of The Electroporation Efficiency Of Nanosecond Pulses By Swinging The Electric Field Vector Direction, Vitalii Kim, Iurii Semenov, Allen S. Kiester, Mark A. Keppler, Bennett L. Ibey, Joel N. Bixler, Ruben M. L. Colunga Biancatelli, Andrei G. Pakhomov
Bioelectrics Publications
Reversing the pulse polarity, i.e., changing the electric field direction by 180°, inhibits electroporation and electrostimulation by nanosecond electric pulses (nsEPs). This feature, known as “bipolar cancellation,” enables selective remote targeting with nsEPs and reduces the neuromuscular side effects of ablation therapies. We analyzed the biophysical mechanisms and measured how cancellation weakens and is replaced by facilitation when nsEPs are applied from different directions at angles from 0 to 180°. Monolayers of endothelial cells were electroporated by a train of five pulses (600 ns) or five paired pulses (600 + 600 ns) applied at 1 Hz or 833 kHz. Reversing …
Pulsed Electric Field Ablation Of Esophageal Malignancies And Mitigating Damage To Smooth Muscle: An In Vitro Study, Emily Gudvangen, Uma Mangalanathan, Iurii Semenov, Allen S. Kiester, Mark A. Keppler, Bennett L. Ibey, Joel N. Bixler, Andrei G. Pakhomov
Pulsed Electric Field Ablation Of Esophageal Malignancies And Mitigating Damage To Smooth Muscle: An In Vitro Study, Emily Gudvangen, Uma Mangalanathan, Iurii Semenov, Allen S. Kiester, Mark A. Keppler, Bennett L. Ibey, Joel N. Bixler, Andrei G. Pakhomov
Bioelectrics Publications
Cancer ablation therapies aim to be efficient while minimizing damage to healthy tissues. Nanosecond pulsed electric field (nsPEF) is a promising ablation modality because of its selectivity against certain cell types and reduced neuromuscular effects. We compared cell killing efficiency by PEF (100 pulses, 200 ns–10 µs duration, 10 Hz) in a panel of human esophageal cells (normal and pre-malignant epithelial and smooth muscle). Normal epithelial cells were less sensitive than the pre-malignant ones to unipolar PEF (15–20% higher LD50, p < 0.05). Smooth muscle cells (SMC) oriented randomly in the electric field were more sensitive, with 30–40% lower LD50 (p < 0.01). Trains of ten, 300-ns pulses at 10 kV/cm caused twofold weaker electroporative uptake of YO-PRO-1 dye in normal epithelial cells than in either pre-malignant cells or in SMC oriented perpendicularly to the field. Aligning SMC with the field reduced the dye uptake fourfold, along with a twofold reduction in Ca2+ transients. A 300-ns pulse induced a twofold smaller transmembrane potential in cells aligned with the field, making them …
Identification Of Proteins Involved In Cell Membrane Permeabilization By Nanosecond Electric Pulses (Nsep), Giedre Silkuniene, Uma Mangalanathan, Alessandra Rossi, Peter A. Mollica, Andrei G. Pakhomov, Olga N. Pakhomova
Identification Of Proteins Involved In Cell Membrane Permeabilization By Nanosecond Electric Pulses (Nsep), Giedre Silkuniene, Uma Mangalanathan, Alessandra Rossi, Peter A. Mollica, Andrei G. Pakhomov, Olga N. Pakhomova
Bioelectrics Publications
The study was aimed at identifying endogenous proteins which assist or impede the permeabilized state in the cell membrane disrupted by nsEP (20 or 40 pulses, 300 ns width, 7 kV/cm). We employed a LentiArray CRISPR library to generate knockouts (KOs) of 316 genes encoding for membrane proteins in U937 human monocytes stably expressing Cas9 nuclease. The extent of membrane permeabilization by nsEP was measured by the uptake of Yo-Pro-1 (YP) dye and compared to sham-exposed KOs and control cells transduced with a non-targeting (scrambled) gRNA. Only two KOs, for SCNN1A and CLCA1 genes, showed a statistically significant reduction in …
Probing Nanoelectroporation And Resealing Of The Cell Membrane By The Entry Of Ca2+ And Ba2+ Ions, Wenfei Bo, Mantas Silkunas, Uma Mangalanathan, Vitalij Novickij, Maura Casciola, Iurii Semenov, Shu Xiao, Olga N. Pakhomova, Andrei G. Pakhomov
Probing Nanoelectroporation And Resealing Of The Cell Membrane By The Entry Of Ca2+ And Ba2+ Ions, Wenfei Bo, Mantas Silkunas, Uma Mangalanathan, Vitalij Novickij, Maura Casciola, Iurii Semenov, Shu Xiao, Olga N. Pakhomova, Andrei G. Pakhomov
Bioelectrics Publications
The principal bioeffect of the nanosecond pulsed electric field (nsPEF) is a lasting cell membrane permeabilization, which is often attributed to the formation of nanometer-sized pores. Such pores may be too small for detection by the uptake of fluorescent dyes. We tested if Ca2+, Cd2+, Zn2+, and Ba2+ ions can be used as nanoporation markers. Time-lapse imaging was performed in CHO, BPAE, and HEK cells loaded with Fluo-4, Calbryte, or Fluo-8 dyes. Ca2+ and Ba2+ did not change fluorescence in intact cells, whereas their entry after nsPEF increased fluorescence within <1 ms. The threshold for one 300-ns pulse was at 1.5–2 kV/cm, much lower than >7 …1>
Electropermeabilization Does Not Correlate With Plasma Membrane Lipid Oxidation, Olga Michel, Andrei G. Pakhomov, Maura Casciola, Jolanta Saczko, Julita Kulbacka, Olga N. Pakhomova
Electropermeabilization Does Not Correlate With Plasma Membrane Lipid Oxidation, Olga Michel, Andrei G. Pakhomov, Maura Casciola, Jolanta Saczko, Julita Kulbacka, Olga N. Pakhomova
Bioelectrics Publications
The permeabilized condition of the cell membrane after electroporation can last minutes but the underlying mechanisms remain elusive. Previous studies suggest that lipid peroxidation could be responsible for the lasting leaky state of the membrane. The present study aims to link oxidation within the plasma membrane of live cells to permeabilization by electric pulses. We have introduced a method for the detection of oxidation by ratiometric fluorescence measurements of BODIPY-C11 dye using total internal reflection fluorescence (TIRF) microscopy, limiting the signal to the cell membrane. CHO-K1 cells were cultured on glass coverslips coated with an electroconductive indium tin oxide (ITO) …