Open Access. Powered by Scholars. Published by Universities.®
Bioelectrical and Neuroengineering Commons™
Open Access. Powered by Scholars. Published by Universities.®
- Discipline
-
- Life Sciences (8)
- Biomedical Devices and Instrumentation (5)
- Biotechnology (4)
- Electrical and Computer Engineering (4)
- Bioimaging and Biomedical Optics (3)
-
- Biomedical (3)
- Medicine and Health Sciences (3)
- Molecular, Cellular, and Tissue Engineering (3)
- Physiology (3)
- Biological Engineering (2)
- Biology (2)
- Cellular and Molecular Physiology (2)
- Genetics (2)
- Genetics and Genomics (2)
- Neuroscience and Neurobiology (2)
- Signal Processing (2)
- Aerospace Engineering (1)
- Anatomy (1)
- Animal Studies (1)
- Biomechanics and Biotransport (1)
- Cell Biology (1)
- Cell and Developmental Biology (1)
- Civil and Environmental Engineering (1)
- Computational Engineering (1)
- Computer Engineering (1)
- Construction Engineering and Management (1)
- Electromagnetics and Photonics (1)
- Institution
- Keyword
-
- Ablation (2)
- MRI (2)
- Accumulation (1)
- Adenocarcinoma (1)
- Alzheimer’s disease (1)
-
- Artificial Neural Network (1)
- Artificial neural networks (1)
- Auditory Nerve (1)
- Bioinstrumentation (1)
- Biomarker (1)
- Biomedical (1)
- Block (1)
- Brain Computer Interface (1)
- Cancer (1)
- Cell cycle and cell division (1)
- Cell cycle inhibitors (1)
- Cells (1)
- Clinical trials (1)
- Cochlear Non-Linearity (1)
- Connectivity (1)
- Coordination (1)
- Cranial nerves (1)
- Critical Band (1)
- Cuff electrode (1)
- Cyclins (1)
- DNA damage (1)
- Deformable atlas (1)
- EEG (1)
- Electric stimulation (1)
- Electrochemotherapy (1)
- Publication
-
- Bioelectrics Publications (5)
- The Summer Undergraduate Research Fellowship (SURF) Symposium (3)
- Biomedical Engineering Undergraduate Honors Theses (2)
- Biomedical Engineering Western Regional Conference (2)
- Master's Theses (2)
-
- Biological Sciences Faculty Publications (1)
- College of Graduate Studies: Theses & Dissertations (1)
- Computational Modeling & Simulation Engineering Theses & Dissertations (1)
- Dissertations (1934 -) (1)
- Libraries' Newsletters (1)
- Master's Theses (2009 -) (1)
- McKelvey School of Engineering Graduate Student Theses & Dissertations (1)
- Mechanical and Materials Engineering Faculty Publications and Presentations (1)
- Research Opportunities for Engineering Undergraduates (ROEU) Program 2016-17 (1)
- Publication Type
Articles 1 - 23 of 23
Full-Text Articles in Bioelectrical and Neuroengineering
Interfacing A Hirudo Medicinalis Retzius Cell With Insulated Gate Of Mosfet, Rachel M. Smith
Interfacing A Hirudo Medicinalis Retzius Cell With Insulated Gate Of Mosfet, Rachel M. Smith
Master's Theses
Much work has been done to study the external stimulation of nervous tissue as well as the transmission of neural signals to electronics. Peter Fromherz was one of the pioneers in this area of electrophysiology, with a series of experiments in the 1990s that aimed to characterize and optimize the interface between neural tissue and transistors. In this thesis, Kurt Sjoberg and I interfaced a Retzius cell isolated from a Hirudo medicinalis ganglion with the insulated gate of a MOSFET. The goal was to see change in membrane potential that could be related Fromherz’s original 1991 work. Our experimental setup …
Computer-Aided Diagnoses (Cad) System: An Artificial Neural Network Approach To Mri Analysis And Diagnosis Of Alzheimer's Disease (Ad), Berizohar Padilla Cerezo
Computer-Aided Diagnoses (Cad) System: An Artificial Neural Network Approach To Mri Analysis And Diagnosis Of Alzheimer's Disease (Ad), Berizohar Padilla Cerezo
Master's Theses
Alzheimer’s disease (AD) is a chronic and progressive, irreversible syndrome that deteriorates the cognitive functions. Official death certificates of 2013 reported 84,767 deaths from Alzheimer’s disease, making it the 6th leading cause of death in the United States. The rate of AD is estimated to double by 2050. The neurodegeneration of AD occurs decades before symptoms of dementia are evident. Therefore, having an efficient methodology for the early and proper diagnosis can lead to more effective treatments.
Neuroimaging techniques such as magnetic resonance imaging (MRI) can detect changes in the brain of living subjects. Moreover, medical imaging techniques are the …
Muscle Coordination Contributes To Function After Stroke; Proprioception Contributes To Control Of Posture, Movement, Maria Bengtson
Muscle Coordination Contributes To Function After Stroke; Proprioception Contributes To Control Of Posture, Movement, Maria Bengtson
Dissertations (1934 -)
More than half of stroke survivors experience persistent upper extremity motor impairments that can negatively impact quality of life and independence. Effective use of the upper extremity requires coordination of agonist/antagonist muscle pairs, as well as coordination of multiple control actions for stabilizing and moving the arm. In this dissertation, I present three studies in which I recorded isometric torque production, single joint movement and stabilization, and clinical measures of function and impairments after stroke to evaluate the extent to which changes in coordination of agonist/antagonist muscles and of sequential control actions contribute to deficits after stroke. In Aim 1, …
Delayed Hypersensitivity To Nanosecond Pulsed Electric Field In Electroporated Cells, Sarah D. Jensen, Vera A. Khorokhorina, Claudia Muratori, Andrei G. Pakhomov, Olga N. Pakhomova
Delayed Hypersensitivity To Nanosecond Pulsed Electric Field In Electroporated Cells, Sarah D. Jensen, Vera A. Khorokhorina, Claudia Muratori, Andrei G. Pakhomov, Olga N. Pakhomova
Bioelectrics Publications
We demonstrate that conditioning of mammalian cells by electroporation with nanosecond pulsed electric field (nsPEF) facilitates their response to the next nsPEF treatment. The experiments were designed to unambiguously separate the electroporation-induced sensitization and desensitization effects. Electroporation was achieved by bursts of 300-ns, 9 kV/cm pulses (50 Hz, n = 3–100) and quantified by propidium dye uptake within 11 min after the nsPEF exposure. We observed either sensitization to nsPEF or no change (when the conditioning was either too weak or too intense, or when the wait time after conditioning was too short). Within studied limits, conditioning never caused desensitization. …
Damage-Free Peripheral Nerve Stimulation By 12-Ns Pulsed Electric Field, Maura Casciola, Shu Xiao, Andrei G. Pakhomov
Damage-Free Peripheral Nerve Stimulation By 12-Ns Pulsed Electric Field, Maura Casciola, Shu Xiao, Andrei G. Pakhomov
Bioelectrics Publications
Modern technologies enable deep tissue focusing of nanosecond pulsed electric field (nsPEF) for non-invasive nerve and muscle stimulation. However, it is not known if PEF orders of magnitude shorter than the activation time of voltage-gated sodium channels (VGSC) would evoke action potentials (APs). One plausible scenario requires the loss of membrane integrity (electroporation) and resulting depolarization as an intermediate step. We report, for the first time, that the excitation of a peripheral nerve can be accomplished by 12-ns PEF without electroporation. 12-ns stimuli at 4.1-11 kV (3.3-8.8 kV/cm) evoked APs similarly to conventional stimuli (100-250 mus, 1-5 V, 103-515 V/m), …
Controllable Moderate Heating Enhances The Therapeutic Efficacy Of Irreversible Electroporation For Pancreatic Cancer, Chelsea M. Edelblute, James Hornef, Niculina I. Burcus, Thomas Norman, Stephen J. Beebe, Karl Schoenbach, Richard Heller, Chunqi Jiang, Sigi Guo
Controllable Moderate Heating Enhances The Therapeutic Efficacy Of Irreversible Electroporation For Pancreatic Cancer, Chelsea M. Edelblute, James Hornef, Niculina I. Burcus, Thomas Norman, Stephen J. Beebe, Karl Schoenbach, Richard Heller, Chunqi Jiang, Sigi Guo
Bioelectrics Publications
Irreversible electroporation (IRE) as a non-thermal tumor ablation technology has been studied for the treatment of pancreatic carcinoma and has shown a significant survival benefit. We discovered that moderate heating (MH) at 43°C for 1-2 minutes significantly enhanced ex vivo IRE tumor ablation of Pan02 cells by 5.67-fold at 750 V/cm and by 1.67-fold at 1500 V/cm. This amount of heating alone did not cause cell death. An integrated IRE system with controllable laser heating and tumor impedance monitoring was developed to treat mouse ectopic pancreatic cancer. With this novel IRE system, we were able to heat and maintain the …
The Subject Librarian Newsletter, Engineering And Computer Science, Fall 2017, Buenaventura "Ven" Basco
The Subject Librarian Newsletter, Engineering And Computer Science, Fall 2017, Buenaventura "Ven" Basco
Libraries' Newsletters
No abstract provided.
Gui For Mri-Compatible Neural Stimulator And Recorder, Soo Han Soon, Nishant Babaria, Ranajay Mandal, Zhongming Liu
Gui For Mri-Compatible Neural Stimulator And Recorder, Soo Han Soon, Nishant Babaria, Ranajay Mandal, Zhongming Liu
The Summer Undergraduate Research Fellowship (SURF) Symposium
Functional magnetic resonance imaging (fMRI) and electroencephalography (EEG) are useful tools to analyze brain activities given active stimulation. However, the electromagnetic noise from the MRI distorts the brain signal recording and damages the subject with excessive heat generated on the electrodes attached to the skin. MRI-compatible recording and stimulation systems previously developed at LIBI lab were capable of removing the electromagnetic noise during the imaging process. Previously, the hardware systems had required the integrative software that could control both circuits simultaneously and enable users to easily change recording and stimulation parameters. Graphical user interface (GUI) programmed with computer language informed …
Low Power, Low Noise Circuit For Biological Signal Recording, Rachael A. Swenson, Daniel J. Pederson, Pedro Irazoqui
Low Power, Low Noise Circuit For Biological Signal Recording, Rachael A. Swenson, Daniel J. Pederson, Pedro Irazoqui
The Summer Undergraduate Research Fellowship (SURF) Symposium
Implantable devices are ideal for recording biological signals in animal models as they have minimal effect on the animal’s normal behavior during observation. The creation of the circuitry for an implantable device has several restrictions including size, power consumption, and noise reduction. These factors compete against each other, making it necessary to carefully optimize circuit components for a given application. This study evaluates the design of a four-channel analog front end circuit board to record cardiac, neural, and respiratory biological signals. Through a critical analysis of component specifications for the circuit’s components and an evaluation of the circuits’ power and …
Co-Modulation Masking Release Begins In The Auditory Periphery, Kareem R. Hussein, Agudemu Borjigan, Mark Sayles
Co-Modulation Masking Release Begins In The Auditory Periphery, Kareem R. Hussein, Agudemu Borjigan, Mark Sayles
The Summer Undergraduate Research Fellowship (SURF) Symposium
Understanding speech in noisy environments can be difficult, especially for people with hearing loss. The background noise can cover up the sounds of interest. Normally, the auditory system works to alleviate this problem by tagging and then cancelling the noise. Our experiments are aimed at understanding the mechanism of this noise cancellation process. We hypothesize that non-linear signal processing in the mammalian cochlea (the most peripheral part of the auditory system) is the basis of noise cancellation. To test this hypothesis, we measured the responses of auditory-nerve fibers (ANFs) to sounds embedded in background noise with different statistical properties. ANFs …
Characterization Of The High Frequency Alternating Current Block In The Rat Sciatic Nerve Using Cuff Electrodes And Macro-Sieve Electrodes, Soumyajit Ray
McKelvey School of Engineering Graduate Student Theses & Dissertations
Tripolar cuff electrodes were designed, fabricated and non-chronically implanted in the sciatic nerve of two-month-old Lewis rats. A proximal constant current stimulus to the nerve was blocked by applying a high frequency sinusoidal signal to the distally placed tripolar cuff electrode. The frequency voltage characteristic of the blocking signal was obtained. Complete block was not achieved using variants of the tripolar cuff design and bipolar cuff electrodes. Single and dual macro-sieve electrode assemblies were designed, fabricated and chronically implanted in the sciatic nerve of Lewis rats. After a four-month period for regeneration four different electrode configurations were tested to enable …
Anaplasma Phagocytophilum Infection Modulates Expression Of Megakaryocyte Cell Cycle Genes Through Phosphatidylinositol-3-Kinase Signaling, Supreet Khanal, Hameeda Sultana, John D. Catravas, Jason A. Carlyon, Girish Neelakanta
Anaplasma Phagocytophilum Infection Modulates Expression Of Megakaryocyte Cell Cycle Genes Through Phosphatidylinositol-3-Kinase Signaling, Supreet Khanal, Hameeda Sultana, John D. Catravas, Jason A. Carlyon, Girish Neelakanta
Biological Sciences Faculty Publications
Anaplasma phagocytophilum, the agent of human granulocytic anaplasmosis infects neutrophils and other cells from hematopoietic origin. Using human megakaryocytic cell line, MEG-01, we show that expression of cell cycle genes in these cells are altered upon A. phagocytophilum infection. Expression of several cell cycle genes in MEG-01 cells was significantly up regulated at early and then down regulated at later stages of A. phagocytophilum infection. Lactate dehydrogenase (LDH) assays revealed reduced cellular cytotoxicity in MEG-01 cells upon A. phagocytophilum infection. The levels of both PI3KCA (p110 alpha, catalytic subunit) and PI3KR1 (p85, regulatory subunit) of Class …
Reactive Stepping With Functional Neuromuscular Stimulation In Response To Forward-Directed Perturbations, Alexander J. Hunt, Brooke M. Odle, Lisa M. Lombardo, Musa L. Audu, Ronald J. Triolo
Reactive Stepping With Functional Neuromuscular Stimulation In Response To Forward-Directed Perturbations, Alexander J. Hunt, Brooke M. Odle, Lisa M. Lombardo, Musa L. Audu, Ronald J. Triolo
Mechanical and Materials Engineering Faculty Publications and Presentations
Background: Implanted motor system neuroprostheses can be effective at increasing personal mobility of persons paralyzed by spinal cord injuries. However, currently available neural stimulation systems for standing employ patterns of constant activation and are unreactive to changing postural demands. Methods: In this work, we developed a closed-loop controller for detecting forward-directed body disturbances and initiating a stabilizing step in a person with spinal cord injury. Forward-directed pulls at the waist were detected with three body-mounted triaxial accelerometers. A finite state machine was designed and tested to trigger a postural response and apply stimulation to appropriate muscles so as to produce …
Characterization Of The Response Of Trpv4 To Chemical Stimulation, Jacob V. Schluns
Characterization Of The Response Of Trpv4 To Chemical Stimulation, Jacob V. Schluns
Biomedical Engineering Undergraduate Honors Theses
Traumatic Brain Injury (TBI) is a source of acute and chronic health issues for many patients. One of the components of the brain’s response to injury is astrogliosis, in which astrocytes that normally function to repair the brain instead form scar tissue that halts repair processes. Transient Receptor Potential Vanilloid Type 4 (TRPV4) is a trans-membrane calcium channel involved in astrogliosis. Through Fura-2AM based calcium imaging, the base activity of this channel in mouse astrocyte cells was recorded. The cells were then subjected to TRPV4 agonist and antagonist stimulation and their subsequent activity levels were recorded. The data showed that …
Role Of Trpv4 In Astrocyte Extracellular Matrix Production, Abby Terlouw
Role Of Trpv4 In Astrocyte Extracellular Matrix Production, Abby Terlouw
Biomedical Engineering Undergraduate Honors Theses
Traumatic Brain Injury (TBI) is an alteration of brain pathology following damage of the central nervous system (CNS) by an external force. In the CNS, glial scar formation often occurs following TBI, and astrocytes are widely believed to contribute to this scar formation. While the role of astrocytes in extracellular matrix (ECM) production is known, the exact mechanism(s) for this event remain unclear. One possible method is the activation of transient receptor potential vanilloid 4 (TRPV4). TRPV4 is a channel protein found in the astrocyte membrane which has been shown to generate intracellular calcium ions following mechanical stimulation. Previous research …
Developing An Imaging Biomarker To Detect Aberrant Brain Connectivity In Individual Patients, Esther Cox
Developing An Imaging Biomarker To Detect Aberrant Brain Connectivity In Individual Patients, Esther Cox
Master's Theses (2009 -)
Resting state functional MRI (rsfMRI) has been proven to be a valuable tool in clinical applications such as pre-surgical mapping, but there is not yet a functional and usable algorithm that can be used by physicians in a clinical setting to evaluate an individual patient for diseases and aberrant brain connectivity. If a physician wants to evaluate a patient in this way, the rsfMRI data must be looked at “by hand,” i.e. the physician must manually evaluate the data and identify the functional ICN’s and whether they are normal or aberrant. An algorithm that would automate this process and supplement …
Development Of An Atlas-Based Segmentation Of Cranial Nerves Using Shape-Aware Discrete Deformable Models For Neurosurgical Planning And Simulation, Sharmin Sultana
Development Of An Atlas-Based Segmentation Of Cranial Nerves Using Shape-Aware Discrete Deformable Models For Neurosurgical Planning And Simulation, Sharmin Sultana
Computational Modeling & Simulation Engineering Theses & Dissertations
Twelve pairs of cranial nerves arise from the brain or brainstem and control our sensory functions such as vision, hearing, smell and taste as well as several motor functions to the head and neck including facial expressions and eye movement. Often, these cranial nerves are difficult to detect in MRI data, and thus represent problems in neurosurgery planning and simulation, due to their thin anatomical structure, in the face of low imaging resolution as well as image artifacts. As a result, they may be at risk in neurosurgical procedures around the skull base, which might have dire consequences such as …
Ultrasonic Power Transfer For Medical Implants, Kee S. Moon, Yusuf Ozturk, Sung Q. Lee, Woosub Youm, Guun Hwang, H. W. Park
Ultrasonic Power Transfer For Medical Implants, Kee S. Moon, Yusuf Ozturk, Sung Q. Lee, Woosub Youm, Guun Hwang, H. W. Park
Biomedical Engineering Western Regional Conference
Wireless power transmission is an attractive alternative to low-power biomedical implants to overcome the power limitation of the primary battery. In this paper, we are presenting an efficient ultrasonic wireless power transmission system for implantable medical devices. It is known that the ultrasonic wireless power transmission has a longer power transmission distance as well as free from electromagnetic interference and absorption in the human body. In this research, an ultrasonic resonance will be applied to improve the power transmission efficiency as well as the distance.
A Model Of Gradual Dopamine Depletion In The Rat, Christine Henry, Heidi Y. Febinger, Alan Dorval
A Model Of Gradual Dopamine Depletion In The Rat, Christine Henry, Heidi Y. Febinger, Alan Dorval
Biomedical Engineering Western Regional Conference
No abstract provided.
The Effects Of Exercise And An Enhanced Nerve Conduit On Peripheral Nerve Injury, Anthony R. Mora
The Effects Of Exercise And An Enhanced Nerve Conduit On Peripheral Nerve Injury, Anthony R. Mora
Research Opportunities for Engineering Undergraduates (ROEU) Program 2016-17
The primary objective of this effort is to quantify peripheral nerve recovery as a result of exposure to a multimodal conduit in addition to exercise. Quantification was based on behavioral data collected from a rat sciatic nerve model.
Electrotransfer Of Plasmid Dna Radiosensitizes B16f10 Tumors Through Activation Of Immune Response, Monika Savarin, Urska Kamensek, Maja Cemazar, Richard Heller, Gregor Sersa
Electrotransfer Of Plasmid Dna Radiosensitizes B16f10 Tumors Through Activation Of Immune Response, Monika Savarin, Urska Kamensek, Maja Cemazar, Richard Heller, Gregor Sersa
Bioelectrics Publications
Background. Tumor irradiation combined with adjuvant treatments, either vascular targeted or immunomodulatory, is under intense investigation. Gene electrotransfer of therapeutic genes is one of these approaches. The aim of this study was to determine, whether gene electrotransfer of plasmid encoding shRNA for silencing endoglin, with vascular targeted effectiveness, can radiosensitize melanoma B16F10 tumors.
Materials and methods. The murine melanoma Bl6F10 tumors, growing on the back of C57BI/6 mice, were treated by triple gene electrotransfer and irradiation. The antitumor effect was evaluated by determination of tumor growth delay and proportion of tumor free mice. Furthermore, histological analysis of tumors (necrosis, apoptosis, …
Transient Alt Activation Protects Human Primary Cells From Chromosome Instability Induced By Low Chronic Oxidative Stress, Elisa Coluzzi, Rossella Buonsante, Stefano Leone, Anthony J. Asmar, Kelley L. Miller, Daniela Cimini, Antonella Sgura
Transient Alt Activation Protects Human Primary Cells From Chromosome Instability Induced By Low Chronic Oxidative Stress, Elisa Coluzzi, Rossella Buonsante, Stefano Leone, Anthony J. Asmar, Kelley L. Miller, Daniela Cimini, Antonella Sgura
Bioelectrics Publications
Cells are often subjected to the effect of reactive oxygen species (ROS) as a result of both intracellular metabolism and exposure to exogenous factors. ROS-dependent oxidative stress can induce 8-oxodG within the GGG triplet found in the G-rich human telomeric sequence (TTAGGG), making telomeres highly susceptible to ROS-induced oxidative damage. Telomeres are nucleoprotein complexes that protect the ends of linear chromosomes and their dysfunction is believed to affect a wide range of cellular and/or organismal processes. Acute oxidative stress was shown to affect telomere integrity, but how prolonged low level oxidative stress, which may be more physiologically relevant, affects telomeres …
A Comprehensive Analysis On Eeg Signal Classification Using Advanced Computational Analysis, Kaushik Bhimraj
A Comprehensive Analysis On Eeg Signal Classification Using Advanced Computational Analysis, Kaushik Bhimraj
College of Graduate Studies: Theses & Dissertations
Electroencephalogram (EEG) has been used in a wide array of applications to study mental disorders. Due to its non-invasive and low-cost features, EEG has become a viable instrument in Brain-Computer Interfaces (BCI). These BCI systems integrate user's neural features with robotic machines to perform tasks. However, due to EEG signals being highly dynamic in nature, BCI systems are still unstable and prone to unanticipated noise interference. An important application of this technology is to help facilitate the lives of the tetraplegic through assimilating human brain impulses and converting them into mechanical motion. However, BCI systems are remarkably challenging to implement …