Effect Of Extracellular Matrix (Ecm) Protein Micropatterns On The Behavior Of Human Neuroblastoma Cells, Ishwari Poudel Dec 2011

Effect Of Extracellular Matrix (Ecm) Protein Micropatterns On The Behavior Of Human Neuroblastoma Cells, Ishwari Poudel

Department of Engineering Mechanics: Dissertations, Theses, and Student Research

Recent advances in patterning techniques and emerging surface microtechnologies have allowed cell micropatterning to control spatial location of the cells on a surface as well as cell shape, attachment area, and number of contacting neighbor cells. These parameters play important roles in cell cellular behaviors. Cell micropatterning has thus become one of the most important strategies for biomedical applications, such as, tissue engineering, diagnostic immunoassays, lab-on-chip devices, bio-sensing, etc., and cell biology studies as well. For neuronal cells, there have been attempts to distribute neuronal cells on specific patterns to control cell-to-cell interaction. However, there have been very limited understanding …


Implementation Of Medicinal Leech Preparation To Investigate The Connection Between The Motor Neuron And Muscle Fiber Via Sharp Electrode Electrophysiology, Chandra Nikole Miller Dec 2011

Implementation Of Medicinal Leech Preparation To Investigate The Connection Between The Motor Neuron And Muscle Fiber Via Sharp Electrode Electrophysiology, Chandra Nikole Miller

Master's Theses

There are forty registered organophosphates in the United States and they range from pesticides and insecticides to nerve agents or neurotoxins such as sarin. Organophosphates (OP’s) have been used in chemical warfare for years and tend to lead to death due to an attack on the nervous system. Chemical assays and mass microscopy have been used to assess the concentration of OP’s in the environment, but both methods require the body to metabolize the OP first, which can be detrimental to the victim. It is crucial to come up with a method to investigate and detect these neurotoxins without causing …


An Objective Assessment Of Fetal Neurological Maturation Based On The Co-Variation Of Brain And Heart Rate Patterns, Srinivasan Vairavan Aug 2011

An Objective Assessment Of Fetal Neurological Maturation Based On The Co-Variation Of Brain And Heart Rate Patterns, Srinivasan Vairavan

Theses and Dissertations

An in-utero neurological assessment would aid clinicians in an early detection of fetal neurological distress. However, accessing the fetal brain signal has remained a major challenge. With the advent of Superconducting Quantum Interference Device (SQUID) technology, magnetoencephalogram (MEG), is now an established technique for recording human brain activity. This technique is non-invasive and records the magnetic fields corresponding to electric currents generated by the neurons in the brain. Based on MEG technology, a first-of-a-kind device, named SARA (SQUID Array for Reproductive Assessment), was specifically designed and installed in the Department of Obstetrics and Gynecology, University of Arkansas for Medical Sciences, …


Characterizing Nerve Fiber Activation By Varying Fiber Diameter And Depth Within A Conductive Medium: A Finite Element Approach, Nathan Daniel Soto Aug 2011

Characterizing Nerve Fiber Activation By Varying Fiber Diameter And Depth Within A Conductive Medium: A Finite Element Approach, Nathan Daniel Soto

Master's Theses

In some instances neuropathies can be diagnosed through a conduction velocity test. However, not all neuropathies can be classified using this method. Gaining an understanding of how the stimulus level varies for different fiber sizes at different fiber depths within a conductive medium will provide useful information for simulation studies.

Following a two-step approach using COMSOL and MATLAB, a simulation was implemented to investigate the stimulus necessary to activate different sized fibers at different depths. In this two-step approach, COMSOL was used to describe the voltage profile that would be present within a conductive medium after a stimulus was applied. …


Equivalent Circuit Implementation Of Demyelinated Human Neuron In Spice, Nathan A. Angel Aug 2011

Equivalent Circuit Implementation Of Demyelinated Human Neuron In Spice, Nathan A. Angel

Master's Theses

This work focuses on modeling a demyelinated Hodgkin and Huxley (HH) neuron with Simulated Program with Integrated Circuit Emphasis (SPICE) platform. Demyelinating disorders affect over 350,000 people in the U.S and understanding the demyelination process at the cellular level is necessary to find safe ways to treat the diseases [9]. Utilizing a previous SPICE model of an electrically small cell neuron developed by Szlavik [32], an extended core conductor myelinated neuron was produced in this work. The myelinated neuron developed has seven active Nodes of Ranvier (nodes) separated by a myelin sheath. The myelin sheath can be successfully modeled with …


Brain-Related Chronic Pain Disorder Diagnosis And Assessment Method, Jeffrey Hargrove Jun 2011

Brain-Related Chronic Pain Disorder Diagnosis And Assessment Method, Jeffrey Hargrove

Mechanical Engineering Patents

A method for diagnosing and assessing a brain-related chronic pain disorder. The method includes assessing a subject's brain function, deterrnining the probability that a subject is suffering from chronic pain as a result of an abnormal brain function condition by obtaining a quantitative assessment of the subject's brain function, and making a statistical comparison between the subject's quantitative brain function assessment and either a database of quantitative assessments of the brain functions of normal, healthy individuals, or a database of quantitative assessments of the brain functions of individuals known to have been suffering from chronic pain as a result of …


Evaluation Of Delivery Conditions For Cutaneous Plasmid Electrotransfer Using A Multielectrode Array, Bernadette Ferraro, Loree C. Heller, Yolmari L. Cruz, Siqi Guo, Amy Donate, Richard Heller May 2011

Evaluation Of Delivery Conditions For Cutaneous Plasmid Electrotransfer Using A Multielectrode Array, Bernadette Ferraro, Loree C. Heller, Yolmari L. Cruz, Siqi Guo, Amy Donate, Richard Heller

Bioelectrics Publications

Electroporation (EP) is a simple in vivo method to deliver normally impermeable molecules, such as plasmid DNA, to a variety of tissues. Delivery of plasmid DNA by EP to a large surface area is not practical because the distance between the electrode pairs, and therefore the applied voltage, must be increased to effectively permeabilize the cell membrane. The design of the multielectrode array (MEA) incorporates multiple electrode pairs at a fixed distance to allow for delivery of plasmid DNA to the skin, potentially reducing the sensation associated with in vivo EP. In this report, we evaluate the effects of field …


Investigation Of A Simulated Annealing Cooling Schedule Used To Optimize The Estimation Of The Fiber Diameter Distribution In A Peripheral Nerve Trunk, Arya Vigeh May 2011

Investigation Of A Simulated Annealing Cooling Schedule Used To Optimize The Estimation Of The Fiber Diameter Distribution In A Peripheral Nerve Trunk, Arya Vigeh

Master's Theses

In previous studies it was determined that the fiber diameter distribution in a peripheral nerve could be estimated by a simulation technique known as group delay. These results could be further improved using a combinatorial optimization algorithm called simulated annealing. This paper explores the structure and behavior of simulated annealing for the application of optimizing the group delay estimated fiber diameter distribution. Specifically, a set of parameters known as the cooling schedule is investigated to determine its effectiveness in the optimization process.

Simulated annealing is a technique for finding the global minimum (or maximum) of a cost function which may …


Novel Bioelectrical Measurement Using A Digital Biopotential Monode, Mark Nolan, Edward Burke, Eugene Coyle Jan 2011

Novel Bioelectrical Measurement Using A Digital Biopotential Monode, Mark Nolan, Edward Burke, Eugene Coyle

Conference Papers

In conventional biopotential recording, two or more electrodes are placed on the body. A unipolar lead records the time-varying electrical potential at a single point (relative to a reference potential) via one signal electrode. A bipolar lead records the time-varying potential difference between two points via two signal electrodes. In each case, the signal electrodes are connected to high impedance amplifier inputs, while an additional electrode provides a low-impedance path between the amplifier and human subject. Bipolar leads are usually preferred since interference appearing at both signal electrodes can be eliminated using an instrumentation amplifier with high CMRR. A drawback …


Electro-Gene Transfer To Skin Using A Noninvasive Multielectrode Array, Siqi Guo, Amy Donate, Gaurav Basu, Cathryn Lundberg, Loree Heller, Richard Heller Jan 2011

Electro-Gene Transfer To Skin Using A Noninvasive Multielectrode Array, Siqi Guo, Amy Donate, Gaurav Basu, Cathryn Lundberg, Loree Heller, Richard Heller

Bioelectrics Publications

Because of its large surface area and easy access for both delivery and monitoring, the skin is an attractive target for gene therapy for cutaneous diseases, vaccinations and several metabolic disorders. The critical factors for DNA delivery to the skin by electroporation (EP) are effective expression levels and minimal or no tissue damage. Here, we evaluated the non-invasive multielectrode array (MEA) for gene electrotransfer. For these studies we utilized a guinea pig model, which has been shown to have a similar thickness and structure to human skin. Our results demonstrate significantly increased gene expression 2 to 3 logs above injection …