Open Access. Powered by Scholars. Published by Universities.®
Bioelectrical and Neuroengineering Commons™
Open Access. Powered by Scholars. Published by Universities.®
- Discipline
- Keyword
Articles 1 - 3 of 3
Full-Text Articles in Bioelectrical and Neuroengineering
A Robust Lpc Filtering Method For Time-Resolved Morphology Of Eeg Activity Analysis, Jin Xu, Mark Davis, Ruairí De Fréin
A Robust Lpc Filtering Method For Time-Resolved Morphology Of Eeg Activity Analysis, Jin Xu, Mark Davis, Ruairí De Fréin
Conference Papers
This paper introduces a new time-resolved spectral analysis method based on Linear Prediction Coding (LPC) method that is particularly suited to the study of the dynamics of EEG (Electroencephalogram) activity. The spectral dynamic of EEG signals can be challenging to analyse as they contain multiple frequency components and are often heavily corrupted by noise. Furthermore, the temporal and spectral resolution that can be achieved is limited by the Heisenberg-Gabor uncertainty principle [1]. The method described here is based on a z-plane analysis of the poles of the LPC which allows us to identify and estimate the frequency of the dominant …
Novel Bioelectrical Measurement Using A Digital Biopotential Monode, Mark Nolan, Edward Burke, Eugene Coyle
Novel Bioelectrical Measurement Using A Digital Biopotential Monode, Mark Nolan, Edward Burke, Eugene Coyle
Conference Papers
In conventional biopotential recording, two or more electrodes are placed on the body. A unipolar lead records the time-varying electrical potential at a single point (relative to a reference potential) via one signal electrode. A bipolar lead records the time-varying potential difference between two points via two signal electrodes. In each case, the signal electrodes are connected to high impedance amplifier inputs, while an additional electrode provides a low-impedance path between the amplifier and human subject. Bipolar leads are usually preferred since interference appearing at both signal electrodes can be eliminated using an instrumentation amplifier with high CMRR. A drawback …
An Investigation Of The Use Of A High Resolution Adc As A Digital Biopotential Amplifier, Damon Berry, Frank Duignan, Richard Hayes
An Investigation Of The Use Of A High Resolution Adc As A Digital Biopotential Amplifier, Damon Berry, Frank Duignan, Richard Hayes
Conference Papers
Sigma delta analogue to digital converters have been used in many signal processing applications including some commercially available systems for sampling of bio-signals Bio-potential amplifiers have traditionally utilised specialised highquality analogue components to amplify bio-signals.
The central aim of this work is to investigate the benefits of using high-resolution sigma delta conversion as a digital amplification stage in the signal path of a bio-potential amplifier. A number of system arrangements specific to bio-potential measurement are presented and discussed. These arrangements are designed to use the high resolution capacity of the sigma delta converter in different ways, providing different benefits. To …