Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 3 of 3

Full-Text Articles in Bioelectrical and Neuroengineering

Detection Of Standing And Sitting Variations Based On In-Socket Piezoelectric Sensors For Transfemoral Amputees, Alnusairi Tawfik Yahya Aug 2020

Detection Of Standing And Sitting Variations Based On In-Socket Piezoelectric Sensors For Transfemoral Amputees, Alnusairi Tawfik Yahya

Student Works (2020-2029)

A transfemoral prosthesis is required to assist amputees to perform activities of daily living (ADL). The purely mechanical or passive prosthesis has some drawbacks such as consumption of high metabolic energy and limitations in mimicking normal dynamics and kinematics of gait pattern. In contrast, the active prosthesis offers better performance and consumes less metabolic energy. However, recent active prosthesis uses surface electromyography as its sensory system which requires massive preparation work, causes sores to the patient by its electrodes and requires a lot of computation to extract meaningful features. This thesis focuses on developing signal conditioning circuitry to classify six …


Investigation Of Dielectric Properties Of Urine For Pregnancy And Bladder Cancer Detection, Chao Zhe Zhu Mar 2020

Investigation Of Dielectric Properties Of Urine For Pregnancy And Bladder Cancer Detection, Chao Zhe Zhu

Student Works (2020-2029)

Detection and monitoring of pregnancy and bladder cancer are important for medical treatment and nursing. Urine has diagnostic and prognostic values for pregnancy and bladder cancer due to the presence of biomarkers. This study investigated the dielectric properties of human urine and compared them between two groups: 1) non-pregnant healthy female volunteers and pregnant healthy female volunteers, and; 2) healthy subjects and patients with bladder cancer. An open-ended probe network analyzer was used to measure the urine dielectric constant (Ɛ’) and dielectric loss (Ɛ’’) at microwave frequency ranging from 0.2GHz to 50GHz at 25˚C (room temperature), 30˚C and 37˚C (body …


Speckle-Noise Reduction In Knee Articular Cartilage Ultrasound Image Using Anisotropic Diffusion, Ali Muhammad Shoaib Jan 2020

Speckle-Noise Reduction In Knee Articular Cartilage Ultrasound Image Using Anisotropic Diffusion, Ali Muhammad Shoaib

Student Works (2020-2029)

Knee arthritis is the most common type of arthritis which effects the people and may cause severe pain to the patient and can lead to joint effusion. Ultrasound (US) imaging is an appropriate and consistent substitute for other imaging techniques like magnetic resonance imaging or X-rays in the investigation or screening of knee injury. Nevertheless, one of the major problems in US images which make the analysis of these images hard is the presence of speckle noise. For the reduction of speckle noise, the performance of the anisotropic method is found much better over other approaches. In removing the speckle …