Open Access. Powered by Scholars. Published by Universities.®

Biomedical Engineering and Bioengineering Commons™

Open Access. Powered by Scholars. Published by Universities.®

2014

Discipline
Institution
Keyword
Publication
Publication Type
File Type

Articles 391 - 420 of 465

Full-Text Articles in Biomedical Engineering and Bioengineering

Continuous Monitoring Of Turning In Patients With Movement Disability, Mahmoud Ahmed El-Gohary, Sean Pearson, James Mcnames, Martina Mancini, Fay Horak, Sabato Mellone, Lorenzo Chiari Jan 2014

Continuous Monitoring Of Turning In Patients With Movement Disability, Mahmoud Ahmed El-Gohary, Sean Pearson, James Mcnames, Martina Mancini, Fay Horak, Sabato Mellone, Lorenzo Chiari

Electrical and Computer Engineering Faculty Publications and Presentations

Difficulty with turning is a major contributor to mobility disability and falls in people with movement disorders, such as Parkinson’s disease (PD). Turning often results in freezing and/or falling in patients with PD. However, asking a patient to execute a turn in the clinic often does not reveal their impairments. Continuous monitoring of turning with wearable sensors during spontaneous daily activities may help clinicians and patients determine who is at risk of falls and could benefit from preventative interventions. In this study, we show that continuous monitoring of natural turning with wearable sensors during daily activities inside and outside the …


Identifying Performance Criteria Of Fully Bioresorbable Scaffolds For Endovascular Applications, Jahid Ferdous Jan 2014

Identifying Performance Criteria Of Fully Bioresorbable Scaffolds For Endovascular Applications, Jahid Ferdous

Theses and Dissertations

Background: Bioresorbable scaffolds (BRS) have revolutionized percutaneous coronary intervention in clinical cardiovascular medicine. As opposed to permanent alternatives such as metallic stents, BRS have an inherent potential to reduce the occurrence of untoward events such as vessel re-narrowing or thrombosis by virtue of undergoing complete and controlled resorption post- implantation. While BRS platforms demonstrate a clear potential to mitigate risk stemming from incomplete vessel healing, they introduce a new set of considerations to clinical safety and efficacy. Foremost among these issues is the fate of and biological response to material by-products that evolve throughout the scaffold degradation and erosion processes, …


Isolation Of Natural Nrf2 Activators From American Ginseng, Akrm Abdalrahman Jan 2014

Isolation Of Natural Nrf2 Activators From American Ginseng, Akrm Abdalrahman

Theses and Dissertations

Nuclear factor erythroid-2 related factor 2 (Nrf2), a major transcription factor of the endogenous antioxidant defense system, has been proposed as a potential therapeutic target for the treatment of various diseases. However, a small molecule-driven Nrf2 signaling therapeutic approach remains to be established. Herein, we report one such possibility discovered by the bioassay-based fractionation of American ginseng. Since crude extract of American ginseng was found to suppress the expression of inducible nitric oxide synthase (iNOS) in lipopolysaccharide (LPS)-inflamed macrophages via activating Nrf2, we further fractioned the crude extract using solvents including hexane, dichloromethane, ethyl acetate, butanol, and water, and found …


Discovery And Characterization Of Multi-Target Directed Ligands As Inhibitors Of Amyloid-Β Aggregation And Regulators Of Alzheimer's Disease, Jui-Heng Tseng Jan 2014

Discovery And Characterization Of Multi-Target Directed Ligands As Inhibitors Of Amyloid-Β Aggregation And Regulators Of Alzheimer's Disease, Jui-Heng Tseng

Theses and Dissertations

Alzheimer's disease (AD) is the most common neurodegenerative disease in the world. As the disease advances, symptoms include confusion, language skill breakdown, and long term memory loss - and culminate in death. Existing therapies for AD provide symptomatic benefits but cannot halt or slow the disease pathogenesis.

Increasing evidence reveals the multi-factorial nature of AD. Numerous factors, including amyloid-β (Aβ) aggregation, calcium homeostasis dysregulation, and oxidative stress, contribute to disease development and interplay with each other. Therefore, multi-target directed ligands (MTDLs) may present an effective AD treatment. Among all factors, Aβ aggregation is suggested to play the most crucial role. …


Bioengineered Hearts, Rivky Loeb Jan 2014

Bioengineered Hearts, Rivky Loeb

The Science Journal of the Lander College of Arts and Sciences

Heart disease is one of the highest causes for fatality in the world. Although many such diseases can be treated by a heart transplant, this in itself can cause countless problems. Aside from the high demand for donor hearts, there is the risk of the patient’s immune system rejecting the transplanted heart. A bioengineered heart would reduce the need for donor hearts, and thus save countless lives. Finding a suitable scaffold, obtaining appropriate cells, and ensuring that the tissue will function properly are the main focuses in creating an artificial heart. While most of the studies done have been concentrated …


Human Cardiovascular Responses To Artificial Gravity Variables: Ground-Based Experimentation For Spaceflight Implementation, Mark Howarth Jan 2014

Human Cardiovascular Responses To Artificial Gravity Variables: Ground-Based Experimentation For Spaceflight Implementation, Mark Howarth

Theses and Dissertations--Biomedical Engineering

One countermeasure to cardiovascular spaceflight deconditioning being tested is the application of intermittent artificial gravity provided by centripetal acceleration of a human via centrifuge. However, artificial gravity protocols have not been optimized for the cardiovascular system, or any other physiological system for that matter. Before artificial gravity protocols can be optimized for the cardiovascular system, cardiovascular responses to the variables of artificial gravity need to be quantified.

The research presented in this document is intended to determine how the artificial gravity variables, radius (gravity gradient) and lower limb exercise, affect cardiovascular responses during centrifugation. Net fluid (blood) shifts between body …


Development Of A Moldable Composite Bone Graft Substitute Releasing Antibacterial And Osteogenic Drugs, Matthew E. Brown Jan 2014

Development Of A Moldable Composite Bone Graft Substitute Releasing Antibacterial And Osteogenic Drugs, Matthew E. Brown

Theses and Dissertations--Biomedical Engineering

Large infected bone defects (IBD) are very complicated to treat due to their high variability; they often require multiple procedures. Bone autografts are the gold standard for treatment but have several drawbacks, such as a need for a second surgery site, limited grafting material, and donor site morbidity. The objective of this research was to develop a moldable synthetic bone grafting material capable of releasing both antimicrobial and osteogenic drugs over a clinically relevant time course for the treatment of IBDs. Current treatment methods for large IBDs require two separate procedures to treat the bone defect and the infection.

This …


The Study Of Trunk Mechanical And Neuromuscular Behaviors, Brian D. Koch Jan 2014

The Study Of Trunk Mechanical And Neuromuscular Behaviors, Brian D. Koch

Theses and Dissertations--Biomedical Engineering

Low back pain (LBP) is a common ailment in the United States, affecting up to 80% of adults at least once in their lifetime. Although 90% of LBP cases are considered nonspecific, recent studies show that abnormal mechanics of the lower back can be a major factor. One method of assessing the lower back mechanical environment is through perturbation experiments. An intensive literature review of perturbation systems was used to select and develop a system for the Human Musculoskeletal Biomechanics Lab (HMBL). Following construction, individuals with high/low exposure to day-long physical activity were assessed to quantify daily changes in their …


Stabilization Of Extended Diffuse Optical Spectroscopy Measurements On In Vivo Human Skeletal Muscle During Dynamic Exercise, Brad A. Henry Jan 2014

Stabilization Of Extended Diffuse Optical Spectroscopy Measurements On In Vivo Human Skeletal Muscle During Dynamic Exercise, Brad A. Henry

Theses and Dissertations--Biomedical Engineering

This research investigates various applications of diffuse correlation spectroscopy (DCS) on in-vivo human muscle tissue, both at rest and during dynamic exercise. Previously suspected muscle tissue relative blood flow (rBF) baseline shift during extended measurement with DCS and DCS-Near infrared spectroscopy (NIRS) hybrid optical systems are verified, quantified, and resolved by redesign of optical probe and alteration in optical probe attachment methodology during 40 minute supine bed rest baseline measurements. We then translate previously developed occlusion techniques, whereby rBF and relative oxygen consumption rV̇O2 are calibrated to initial resting absolute values by use of a venous occlusion (VO) and …


Bioerodible Calcium Sulfate Bone Grafting Substitutes With Tailored Drug Delivery Capabilities, Bryan R. Orellana Jan 2014

Bioerodible Calcium Sulfate Bone Grafting Substitutes With Tailored Drug Delivery Capabilities, Bryan R. Orellana

Theses and Dissertations--Biomedical Engineering

Bone regeneration or augmentation is often required prior to or concomitant with implant placement. With the limitations of many existing technologies, a biologically compatible synthetic bone grafting substitute that is osteogenic, bioerodible, and provides spacing-making functionality while acting as a drug delivery vehicle for bioactive molecules could provide an alternative to ‘gold standard’ techniques.

In the first part of this work, calcium sulfate (CS) space-making synthetic bone grafts with uniformly embedded poly(β-amino ester) (PBAE) biodegradable hydrogel particles was developed to allow controlled release of bioactive agents. The embedded gel particles’ influence on the physical and chemical characteristics of CS was …


Mucoadhesive Films For Treatment Of Local Oral Disorders: Development, Characterization And In Vivo Testing, Sandeep K. Ramineni Jan 2014

Mucoadhesive Films For Treatment Of Local Oral Disorders: Development, Characterization And In Vivo Testing, Sandeep K. Ramineni

Theses and Dissertations--Biomedical Engineering

Mucoadhesive drug delivery systems which are being used from 1980’s to avoid first pass metabolism of drugs, commercially exist for only systemic drug delivery with fast erosion times (15-60 min), that may not be appropriate for local oral disorders. The goal of this research was to develop and characterize mucoadhesive films with flexibility of carrying different drugs and proteins and provide sustained release for local treatment of oral disorders.

Mucoadhesive films composed of polyvinylpyrrolidone (PVP) and carboxymethlycellulose (CMC) were formulated with imiquimod, an immune response modifier. Problems such as solubilization of imiquimod to increase drug loading, uniformity in films and …


Relationships Of Long-Term Bisphosphonate Treatment With Measures Of Bone Microarchitecture And Mechanical Competence, Jonathan Joseph Ward Jan 2014

Relationships Of Long-Term Bisphosphonate Treatment With Measures Of Bone Microarchitecture And Mechanical Competence, Jonathan Joseph Ward

Theses and Dissertations--Biomedical Engineering

Oral bisphosphonate drug therapy is a common and effective treatment for osteoporosis. Little is known about the long-term effects of bisphosphonates on bone quality. This study examined the structural and mechanical properties of trabecular bone following 0-16 years of bisphosphonate treatment. Fifty-three iliac crest bone samples of Caucasian women diagnosed with low turnover osteoporosis were identified from the Kentucky Bone Registry. Forty-five were treated with oral bisphosphonates for 1 to 16 years while eight were treatment naive. A section of trabecular bone was chosen from a micro-computed tomography (Scanco µCT 40) scan of each sample for a uniaxial linearly elastic …


Additives To Control Mechanical Properties And Drug Delivery Of Injectable Polymeric Scaffolds, Paul Fisher Jan 2014

Additives To Control Mechanical Properties And Drug Delivery Of Injectable Polymeric Scaffolds, Paul Fisher

Theses and Dissertations--Biomedical Engineering

In situ forming implants (ISIs) are popular due to their ease of use and local drug delivery potential, but they suffer from high initial drug burst, and release behavior is tied closely to solvent exchange and polymer properties. Additionally, such systems are traditionally viewed purely as drug delivery devices rather than potential scaffold materials due to their poor mechanical properties and minimal porosity. The aim of this research was to develop an injectable ISI with drug release, mechanical, and microstructural properties controlled by micro- and nanoparticle additives.

First, an injectable ISI was developed with appropriate drug release kinetics for orthopedic …


Evaluation Of Tissue-Engineered Tendon Enthesis Polymer Constructs, Joshua A. Bundy Bs, Mary Beth Wade Phd, Hitomi Nakao Md, Phillip Mcclellan Phd, Qing Yu Phd, Robin Jacquet-Childs Ms, William J. Landis Phd Jan 2014

Evaluation Of Tissue-Engineered Tendon Enthesis Polymer Constructs, Joshua A. Bundy Bs, Mary Beth Wade Phd, Hitomi Nakao Md, Phillip Mcclellan Phd, Qing Yu Phd, Robin Jacquet-Childs Ms, William J. Landis Phd

Williams Honors College, Honors Research Projects

Both scientists and clinicians have proposed tissue engineering as the future of medicine. The possibilities for tissue engineering, that is, fabrication of tissues and organs in the laboratory and their translation to patients, appear to be endless, and many believe that this new approach in medicine will result in abolishing many common ailments, injuries, and congenital defects. Injuries to a tendon enthesis, the normal tissue connection between tendon and bone, are of particular concern to clinicians because of their frequency and failure to repair as a result of surgery. While these injuries may not be life threatening, they can certainly …


Theoretical And Experimental Investigations To Improve The Performance Of Surface Acoustic Wave (Saw) Biosensors, Mandek Richardson Jan 2014

Theoretical And Experimental Investigations To Improve The Performance Of Surface Acoustic Wave (Saw) Biosensors, Mandek Richardson

USF Tampa Graduate Theses and Dissertations

The objective of this dissertation is to improve the performance of surface acoustic wave (SAW) biosensors for use in point-of-care-testing (POCT) applications. SAW biosensors have the ability to perform fast, accurate detection of an analyte in real time without the use of labels. However, the technology suffers from the inability to differentiate between specific and non-specific binding. Due to this limitation, direct testing of bodily fluids using SAW sensors to accurately determine an analyte's concentration is difficult. In addition, these sensors are challenged by the need to detect small concentrations of a biomarker that are typically required to give a …


Utilizing Dielectrophoresis To Determine The Physiological Differences Of Eukaryotic Cells, Tayloria Nicole Gail Adams Jan 2014

Utilizing Dielectrophoresis To Determine The Physiological Differences Of Eukaryotic Cells, Tayloria Nicole Gail Adams

Dissertations, Master's Theses and Master's Reports - Open

Type 1 diabetes affects over 108,000 children, and this number is steadily increasing. Current insulin therapies help manage the disease but are not a cure. Over a child’s lifetime they can develop kidney disease, blindness, cardiovascular disease and many other issues due to the complications of type 1 diabetes. This autoimmune disease destroys beta cells located in the pancreas, which are used to regulate glucose levels in the body. Because there is no cure and many children are affected by the disease there is a need for alternative therapeutic options that can lead to a cure.

Human mesenchymal stem cells …


A Backing Device Based On An Embedded Stiffener And Retractable Insertion Tool For Thin-Film Cochlear Arrays, Radheshyam Tewari Jan 2014

A Backing Device Based On An Embedded Stiffener And Retractable Insertion Tool For Thin-Film Cochlear Arrays, Radheshyam Tewari

Dissertations, Master's Theses and Master's Reports - Open

Intracochlear trauma from surgical insertion of bulky electrode arrays and inadequate pitch perception are areas of concern with current hand-assembled commercial cochlear implants. Parylene thin-film arrays with higher electrode densities and lower profiles are a potential solution, but lack rigidity and hence depend on manually fabricated permanently attached polyethylene terephthalate (PET) tubing based bulky backing devices. As a solution, we investigated a new backing device with two sub-systems. The first sub-system is a thin poly(lactic acid) (PLA) stiffener that will be embedded in the parylene array. The second sub-system is an attaching and detaching mechanism, utilizing a poly(N-vinylpyrrolidone)-block-poly(d,l-lactide) (PVP-b-PDLLA) copolymer-based …


Design And Application Of Wireless Passive Magnetoelastic Resonance And Magnetoharmonic Force Sensors, Brandon D. Pereles Jan 2014

Design And Application Of Wireless Passive Magnetoelastic Resonance And Magnetoharmonic Force Sensors, Brandon D. Pereles

Dissertations, Master's Theses and Master's Reports - Open

The objective of the work described in this dissertation is the development of new wireless passive force monitoring platforms for applications in the medical field, specifically monitoring lower limb prosthetics. The developed sensors consist of stress sensitive, magnetically soft amorphous metallic glass materials. The first technology is based on magnetoelastic resonance. Specifically, when exposed to an AC excitation field along with a constant DC bias field, the magnetoelastic material mechanically vibrates, and may reaches resonance if the field frequency matches the mechanical resonant frequency of the material. The presented work illustrates that an applied loading pins portions of the strip, …


Fabrication Of Drug Eluting Ti Implants For Dental/Orthopedic Applications, Azhang Hamlekhan Jan 2014

Fabrication Of Drug Eluting Ti Implants For Dental/Orthopedic Applications, Azhang Hamlekhan

Dissertations, Master's Theses and Master's Reports - Open

Titanium and its alloys are typically used for fabrication of dental and orthopedic implants as they possess various desirable properties including biocompatibility and corrosion resistance. In spite of such benefits, titanium implants show lack of osseointegration after surgery in minor cases. The objective of this research has been to modify the surface of titanium alloy for medical applications through increasing surface hydrophilicity and drug loading. Primarily, anodization method is employed for fabrication of nanotubes on titanium surface to act as anchoring cite for cells.

Considering the key role of surface hydrophilicity on cellular attachment to the surface and subsequent biological …


Synergistic Toughening Of Hard, Nacre-Mimetic Mosi2 Coatings By Self-Assembled Hierarchical Structure, Jiang Xu, Xiaoli Zhao, Paul Munroe, Zonghan Xie Jan 2014

Synergistic Toughening Of Hard, Nacre-Mimetic Mosi2 Coatings By Self-Assembled Hierarchical Structure, Jiang Xu, Xiaoli Zhao, Paul Munroe, Zonghan Xie

Research outputs 2014 to 2021

Like many other intermetallic materials, MoSi2 coatings are typically hard, but prone to catastrophic failure due to their low toughness at ambient temperature. In this paper, a self-assembled hierarchical structure that closely resembles that of nacre (i.e., mother of pearl) was developed in a MoSi2 -based coating through a simple, yet cost-effective, depostion technique. The newly formed coating is tough and can withstand multiple indentations at high loads. Key design features responsible for this remarkable outcome were identified. They include a functionally graded multilayer featuring elastic modulus oscillation, varying sublayer thickness and a columnar structure that are able to attenuate …


Apelin Regulation Of K-Cl Cotransport In Vascular Smooth Muscle Cells., Neelima Sharma Jan 2014

Apelin Regulation Of K-Cl Cotransport In Vascular Smooth Muscle Cells., Neelima Sharma

Browse all Theses and Dissertations

Atherosclerosis and high circulating levels of oxidized low density lipoproteins (oxLDL) are considered among the most important risk factors for the occurrence and development of cardiovascular disease (CVD). During the atherosclerotic lesion repair, phenotypic transition of vascular smooth muscle cells (VSMCs) from contractile to synthetic states plays a central role. In this process, enhanced proliferation/migration of VSMCs, from the tunica media to the intima, is required to sustain blood vessel endothelium integrity, and for inducing vessel wall remodeling in response to injury. At the molecular level, the activity of electroneutral potassium-chloride cotransporters or KCCs, is necessary to: a) allow changes …


A Compact Theory Of Magnetic Nerve Stimulation: Predicting How To Aim, Charles F. Babbs Jan 2014

A Compact Theory Of Magnetic Nerve Stimulation: Predicting How To Aim, Charles F. Babbs

Weldon School of Biomedical Engineering Faculty Publications

Background: A compact theory that predicts quantitatively when and where magnetic neurostimulation will occur is needed as a guide to therapy, ideally providing a single equation that defines the target volume of tissue excited by single or dual coils. Methods: A first-principles analysis of magnetic stimulation incorporating a simplified description of electromagnetic fields and a simplified cable theory of the axon yields a mathematical synthesis predicting how to aim. Results: Nerve stimulation produced by a single circular coil having one or more closely packed turns occurs in donut shaped volume of tissue beneath the coil. Axons spanning several millimeters are …


Noninvasive Measurement Of Cardiac Stroke Volume Using Pulse Wave Velocity And Aortic Dimensions: A Simulation Study, Charles F. Babbs Jan 2014

Noninvasive Measurement Of Cardiac Stroke Volume Using Pulse Wave Velocity And Aortic Dimensions: A Simulation Study, Charles F. Babbs

Weldon School of Biomedical Engineering Faculty Publications

Background: Concerns about the cost-effectiveness of invasive hemodynamic monitoring in critically ill patients using pulmonary artery catheters motivate a renewed search for effective noninvasive methods to measure stroke volume. This paper explores a new approach based on noninvasively measured pulse wave velocity, pulse contour, and ultrasonically determined aortic cross sectional area. Methods: The Bramwell-Hill equation relating pulse wave velocity to aortic compliance is applied. At the time point on the noninvasively measured pulse contour, denoted th, when pulse amplitude has fallen midway between systolic and diastolic values, the portion of stroke volume remaining in the aorta, and in turn the …


Choosing Inclusion Criteria That Minimize The Time And Cost Of Clinical Trials, Charles F. Babbs Jan 2014

Choosing Inclusion Criteria That Minimize The Time And Cost Of Clinical Trials, Charles F. Babbs

Weldon School of Biomedical Engineering Faculty Publications

AIM: To present statistical tools to model and optimize the cost of a randomized clinical trial as a function of the stringency of patient inclusion criteria. METHODS: We consider a two treatment, dichotomous outcome trial that includes a proportion of patients who are strong responders to the tested intervention. Patients are screened for inclusion using an arbitrary number of test results that are combined into an aggregate suitability score. The screening score is regarded as a diagnostic test for the responsive phenotype, having a specific cutoff value for inclusion and a particular sensitivity and specificity. The cutoff is a measure …


The Application Of Graphene Films In Biosensing And Electrowetting, Xuebin Tan Jan 2014

The Application Of Graphene Films In Biosensing And Electrowetting, Xuebin Tan

Wayne State University Dissertations

In recent years, graphene has been found to possess extraordinary electronic, optical, mechanical and electrochemical properties. Graphene is optically transparent and mechanically flexible, and has high electron mobility and conductivity. In this thesis, we propose to investigate graphene's properties in the detection of biomolecules as well as the manipulation of biological samples. Graphene without defects has high charge carrier mobility and surface areas, which is ideal for biosensors. However, literature shows a lot of variations in the measurements using graphene biosensors. In addition, the surface functionalization of graphene in order to enhance the specificity has not been fully investigated yet. …


High-Performance Accelerometer Based On Asymmetric Gapped Cantilevers For Physiological Acoustic Sensing, Yating Hu Jan 2014

High-Performance Accelerometer Based On Asymmetric Gapped Cantilevers For Physiological Acoustic Sensing, Yating Hu

Wayne State University Dissertations

Continuous or mobile monitoring of physiological sounds is expected to play important role in the emerging mobile healthcare field. Because of the miniature size, low cost, and easy installation, accelerometer is an excellent choice for continuous physiological acoustic signal monitoring. However, in order to capture the detailed information in the physiological signals for clinical diagnostic purpose, there are more demanding requirements on the sensitivity/noise performance of accelerometers. In this thesis, a unique piezoelectric accelerometer based on the asymmetric gapped cantilever which exhibits significantly improved sensitivity is extensively studied. A meso-scale prototype is developed for capturing the high quality cardio and …


Degradable Borate Glass Polyalkenoate Cements, L. Shen, A. Coughlan, Mark R. Towler, M. Hall Jan 2014

Degradable Borate Glass Polyalkenoate Cements, L. Shen, A. Coughlan, Mark R. Towler, M. Hall

Chemical and Biochemical Engineering Faculty Research & Creative Works

Glass polyalkenoate cements (GPCs) containing aluminum-free borate glasses having the general composition Ag2O-Na2O-CaO-SrO-ZnO- TiO2-B2O3 were evaluated in this work. An initial screening study of sixteen compositions was used to identify regions of glass formation and cement compositions with promising rheological properties. The results of the screening study were used to develop four model borate glass compositions for further study. A second round of rheological experiments was used to identify a preferred GPC formulation for each model glass composition. The model borate glasses containing higher levels of TiO2 (7.5 mol %) …


Tissue Engineering Scaffold Fabrication And Processing Techniques To Improve Cellular Infiltration, Casey Grey Jan 2014

Tissue Engineering Scaffold Fabrication And Processing Techniques To Improve Cellular Infiltration, Casey Grey

Theses and Dissertations

Electrospinning is a technique used to generate scaffolds composed of nano- to micron-sized fibers for use in tissue engineering. This technology possesses several key weaknesses that prevent it from adoption into the clinical treatment regime. One major weakness is the lack of porosity exhibited in most electrospun scaffolds, preventing cellular infiltration and thus hosts tissue integration. Another weakness seen in the field is the inability to physically cut electrospun scaffolds in the frontal plane for subsequent microscopic analysis (current electrospun scaffold analysis is limited to sectioning in the cross-sectional plane). Given this it becomes extremely difficult to associate spatial scaffold …


Evaluation Of Functional Near Infrared Spectroscopy (Fnirs) For Assessment Of The Visual And Motor Cortices In Adults, Brenna Giacherio Jan 2014

Evaluation Of Functional Near Infrared Spectroscopy (Fnirs) For Assessment Of The Visual And Motor Cortices In Adults, Brenna Giacherio

Browse all Theses and Dissertations

Introduction: Functional near-infrared spectroscopy (fNIRS) is a relatively young technique in the field of medical imaging. As such, it has yet to be widely implemented for clinical use, despite its promising advantages. However, unlike fMRI-its much bulkier and costly counterpart-fNIRS has yet to be proven as a standalone imaging tool within a clinical setting, particularly that of ophthalmology or physical therapy.

Methods: Ten healthy young adults (23.8 ± 4.8 years) participated in the study. Activation of the visual cortex was achieved utilizing various reversing checkerboard stimuli across three data collection sessions for each participant. Further, activation of the motor cortex …


Rab3a As A Modulator Of Homeostatic Synaptic Plasticity, Andrew G. Koesters Jan 2014

Rab3a As A Modulator Of Homeostatic Synaptic Plasticity, Andrew G. Koesters

Browse all Theses and Dissertations

The nervous system is faced with perturbations in activity levels throughout development and in disease or injury states. Neurons need to adapt to these changes in activity, but also need to maintain circuit firing within a normal range to stabilize the network from becoming too excited or too depressed. Homeostatic synaptic plasticity, the compensatory increase or decrease in synaptic strength as a result of excessive circuit inhibition or excitation, is a mechanism that the nervous system utilizes to keep network activity at normal levels. Despite intense effort, little is known about the mechanisms underlying homeostatic synaptic plasticity. Numerous studies have …