Open Access. Powered by Scholars. Published by Universities.®
Biomedical Engineering and Bioengineering Commons™
Open Access. Powered by Scholars. Published by Universities.®
- Discipline
-
- Molecular, Cellular, and Tissue Engineering (58)
- Medicine and Health Sciences (48)
- Biomaterials (43)
- Mechanical Engineering (36)
- Biological Engineering (34)
-
- Biomechanics and Biotransport (30)
- Other Biomedical Engineering and Bioengineering (30)
- Life Sciences (29)
- Bioelectrical and Neuroengineering (27)
- Biomedical Devices and Instrumentation (25)
- Bioimaging and Biomedical Optics (24)
- Electrical and Computer Engineering (20)
- Physical Sciences and Mathematics (19)
- Chemical Engineering (18)
- Materials Science and Engineering (15)
- Biomechanical Engineering (13)
- Medical Specialties (11)
- Cell and Developmental Biology (10)
- Computer Sciences (10)
- Systems and Integrative Engineering (9)
- Analytical, Diagnostic and Therapeutic Techniques and Equipment (8)
- Cell Biology (8)
- Biochemistry, Biophysics, and Structural Biology (7)
- Diseases (7)
- Pharmacy and Pharmaceutical Sciences (7)
- Biology and Biomimetic Materials (6)
- Biotechnology (6)
- Engineering Science and Materials (6)
- Institution
- Keyword
-
- Electrospinning (25)
- Tissue engineering (14)
- Biomechanics (12)
- Cancer (12)
- Biomaterials (11)
-
- Nanoparticles (11)
- Tissue Engineering (11)
- Drug Delivery (9)
- Extracellular Matrix (8)
- Fibronectin (8)
- Hydrogel (8)
- Rehabilitation (8)
- Collagen (7)
- Engineering, Biomedical Engineering (7)
- Extracellular matrix (7)
- Hydrogels (7)
- Lung (7)
- Mechanotransduction (7)
- Modeling (7)
- Drug delivery (6)
- Haptics (6)
- Angiogenesis (5)
- Bioprinting (5)
- Blind (5)
- Brain Computer Interface (5)
- Breast--Radiography (5)
- Computational model (5)
- Decellularization (5)
- Dendrimer (5)
- Engineering, Biomedical Engineering and Bioengineering (5)
- Publication Year
Articles 481 - 510 of 530
Full-Text Articles in Biomedical Engineering and Bioengineering
Development And Validation Of A Computational Musculoskeletal Model Of The Elbow Joint, Justin Paul Fisk
Development And Validation Of A Computational Musculoskeletal Model Of The Elbow Joint, Justin Paul Fisk
Theses and Dissertations
Musculoskeletal computational modeling is a versatile and effective tool which may be used to study joint mechanics, examine muscle and ligament function, and simulate surgical reconstructive procedures. While injury to the elbow joint can be significantly debilitating, questions still remain regarding its normal, pathologic, and repaired behavior. Biomechanical models of the elbow have been developed, but all have assumed fixed joint axes of rotation and ignored the effects of ligaments. Therefore, the objective of this thesis was to develop and validate a computational model of the elbow joint whereby joint kinematics are dictated by three-dimensional bony geometry contact, ligamentous constraints, …
The Lynks Reader, Anne Marie Reamey
The Lynks Reader, Anne Marie Reamey
Theses and Dissertations
Many adults and children have problems reading and comprehending books, signs, written directions, etc. These same individuals have difficulty processing written materials as a result of right hemisphere interference. The Lynks Reader (DLR Co., Richmond, VA) is a commercially developed device which has been used to help individuals move from their right to their left hemisphere and to increase reading fluency and comprehension. The objective of this project was to evaluate the best way to use the various forms of the Lynks Reader. Using the device demonstrated an increase in reading fluency and comprehension by increasing the left hemisphere dominance. …
The Development Of A Multi-Directional Wear Apparatus And The Characterization And Correlation Of Biomechanical And Biotribological Properties Of Bovine Articular Cartilage, Kelly J. Shields
Theses and Dissertations
A multi-directional wear apparatus was developed to simulate the kinematic motion of diarthrodial joints. A comprehensive evaluation including biotribological and biomechanical characterization of articular surfaces was performed with concomitant translational and oscillating rotational motion similar to that experienced in vivo. Various system parameters were evaluated in the designed experiments including normal load magnitude (high/low), surface quality (defect/no defect), and wear pattern (with/without rotation). Biomechanical characterization was achieved through stress relaxation and dynamic cyclical testing. Quasi-linear viscoelastic theory was used to curve-fit the stress relaxation data, while the dynamic data was used to determine the dynamic properties through Fast Fourier Transform …
Quantitative Object Reconstruction Using Abel Transform Tomography And Mixed Variable Optimization, Kevin R. O'Reilly
Quantitative Object Reconstruction Using Abel Transform Tomography And Mixed Variable Optimization, Kevin R. O'Reilly
Theses and Dissertations
Researchers at the Los Alamos National Laboratory (LANL) are interested in quantitatively reconstructing an object using Abel transform x-ray tomography. Specifically, they obtain a radiograph by x-raying an object and attempt to quantitatively determine the number and types of materials and the thicknesses of each material layer. Their current methodologies either fail to provide a quantitative description of the object or are generally too slow to be useful in practice. As an alternative, the problem is modeled here as a mixed variable programming (MVP) problem, in which some variables are nonnumeric and for which no derivative information is available. The …
Biological System Impedance Identification Using Stochastic Estimation And Control, Enrique Mendezaceves
Biological System Impedance Identification Using Stochastic Estimation And Control, Enrique Mendezaceves
Theses and Dissertations
In an effort to find a less invasive way of testing for different cell abnormalities and finding more practical tests for different cellular mutations, this project makes use of a well-known technique called cellular impedance spectroscopy coupled with stochastic estimation. Impedance spectroscopy, the measurement of the complex resistance of a biological body, is not a new technology; it has been around for many years and has been used to make electrical representations of different biological systems. The problem with this procedure is that models cannot be used for system identification. Stochastic estimation can complement a model produced by analyzing the …
Computational Modeling To Predict Mechanical Function Of Joints: Validations And Applications Of Lower Leg Simulations, Peter C. Liacouras
Computational Modeling To Predict Mechanical Function Of Joints: Validations And Applications Of Lower Leg Simulations, Peter C. Liacouras
Theses and Dissertations
Computational models of musculoskeletal joints and limbs can provide useful information about joint mechanics. Validated models can be used as a predictive device for understanding joint function and serve as a clinical tool for predicting the outcome of surgical procedures. A new computational modeling approach was developed for simulating joint kinematics that are dictated by bone/joint anatomy, ligamentous constraints, and applied loading.Three-dimensional computational models of the lower leg were created. Model development involved generating three-dimensional surfaces from CT images, followed by importing these surfaces into SolidWorks and COSMOSMotion. ThroughSolidWorks and COSMOSMotion, each bone surface was created into a solid object …
Detection, Identification And Classification Of Suck, Swallow And Breathing Activity In Premature Infants During Bottle-Feeding, Fedra Adnani
Theses and Dissertations
Prematurity, especially if extreme, is one of the leading causes of problems and/or death after delivery. Among all the problems encountered by premature infants, feeding difficulties are very common. Many premature infants are fed intravenously at first, and they progress to milk feedings provided by a tube passed into the stomach. At around 34 weeks of gestation, premature infants should be able to breastfeed or take a bottle. At the same time such premature infants are usually faced with difficulty making the transition from tube-feeding to full oral feeding. In this study three physiological measurements of premature infants including sucking, …
Evaluation Of Prototype Cell Delivery Catheters Using Agarose Gel And Cell Culture Experiments, Sagar Panse
Evaluation Of Prototype Cell Delivery Catheters Using Agarose Gel And Cell Culture Experiments, Sagar Panse
Theses and Dissertations
Neurodegenerative diseases and brain tumors affect millions of patients worldwide and are associated with significant morbidity and mortality. The blood brain barrier constitutes a major obstacle to delivery of therapeutic agents administered systemically for treating these disorders. Intracranial drug delivery provides a novel way of bypassing the blood brain barrier and achieving high concentration of therapeutic agents in the brain while avoiding systemic side effects. However damage to tissues during insertion of catheters, release of air in the brain and consequent backtracking of dye are some disadvantages with this mode of treatment. We evaluated prototype cell delivery catheters (each with …
Hmg-Coa Reductase Inhibitors Act Synergistically With Ucn-01 Through Ras Inhibition, Payal Khanna
Hmg-Coa Reductase Inhibitors Act Synergistically With Ucn-01 Through Ras Inhibition, Payal Khanna
Theses and Dissertations
The primary objective of this study is to elucidate the mechanism by which the reagent UCN-01 induces apoptosis when administered to leukemia cells along with HmG-CoA reductase inhibitors, mainly the statins. In this study, we demonstrated that exposure of leukemia cell lines to lovastatin (20 uM, 18 hours) and UCN-01 (100 nM, 18 hours) resulted in mitochondria dysfunction, procaspase 3 and 9 cleavage, and PAW degradation along with marked cytochrome C release and apoptosis. Although similar molecular mechanisms have not yet been confirmed in other cancers, our hypothesis holds that enhanced apoptotic effects of UCN-01 are due in part to …
Design And Validation Of A Full Contact Gait Simulator For The Cadaveric Lower Extremity, Joseph Michael Iaquinto
Design And Validation Of A Full Contact Gait Simulator For The Cadaveric Lower Extremity, Joseph Michael Iaquinto
Theses and Dissertations
The projects goal was to create a device to simulate full contact gait in the cadaveric lower extremity. The Contact Gait Simulation System loads specific muscles to recreate anatomical dorsi and plantar flexion of the ankle under axial loading. A system of pneumatic load generation was connected a LabVIEW virtual instrument (VI), which controlled the application of these loads. The loads were roughly based off literature cited EMG data, and further modified from feedback. In addition to controlling the load system, the VI also coordinates external sensor timing. Along with this simulator, software was developed specifically for analyzing pressure data …
Development Of A Software Application To Extract The Features Of Normal Respiratory Sounds From The Lungs And The Trachea, Ranjani Sabarinathan
Development Of A Software Application To Extract The Features Of Normal Respiratory Sounds From The Lungs And The Trachea, Ranjani Sabarinathan
Theses and Dissertations
Auscultation has been widely regarded as one of the most important noninvasive diagnostic tools for clinical diagnosis of the respiratory tract. The purpose of this thesis was to develop a software application capable of extracting the key features of respiratory sound signals from the lungs and trachea of healthy persons. The efficacy of the program was evaluated by the verification of the important features of the sound signals from the left and right lungs and the trachea such as 1) right and left lung symmetry and 2) dissimilarity between the trachea and both lungs. The program was developed in LabView …
Determination Of The Mechanical Properties Of Electrospun Gelatin Based On Polymer Concentration And Fiber Alignment, Leander Taylor Iii
Determination Of The Mechanical Properties Of Electrospun Gelatin Based On Polymer Concentration And Fiber Alignment, Leander Taylor Iii
Theses and Dissertations
The process of electrospinning has given the field of tissue engineering insight into many aspects of tissue engineered scaffolds, including how factors such as fiber diameter and porosity are affected by polymer concentration. However, the affects of fiber alignment upon the material properties of electrospun scaffolds remains unclear. The purpose of this study is to determine how the material properties of electrospun gelatin scaffolds are affected by changes in fiber alignment and starting gelatin concentration. Gelatin scaffolds, with starting concentrations of 80, 100, and 130mg/m1, were electrospun onto a target mandrel rotating at various speeds. Samples of each scaffold were …
Scaffold Permeability As A Means To Determine Fiber Diameter And Pore Size Of Electrospun Fibrinogen, Scott Allen Sell
Scaffold Permeability As A Means To Determine Fiber Diameter And Pore Size Of Electrospun Fibrinogen, Scott Allen Sell
Theses and Dissertations
The purpose of this study was to construct a flowmeter that could accurately measure the hydraulic permeability of electrospun fibrinogen scaffolds, providing insight into the transport properties of electrospun scaffolds while making the measurement of their topographical features (fiber and pore size) more accurate. Three different concentrations of fibrinogen were used (100, 120, and 150mg/ml) to create scaffolds with three different fiber diameters and pore sizes. The fiber diameters and pore sizes of the electrospun scaffolds were analyzed through scanning electron microscopy and image analysis software. The permeability of each scaffold was measured and used to calculate permeability-based fiber diameters …
The Use Of Computerized Dynamic Posturography To Assess The Balance In Individuals With Parkinson's Disease, Theresa Erin Mcguirk
The Use Of Computerized Dynamic Posturography To Assess The Balance In Individuals With Parkinson's Disease, Theresa Erin Mcguirk
Theses and Dissertations
Postural instability is one of the hallmarks of Parkinson's disease (PD), currently evaluated using several subjective tools. However, the nature and degree of the resulting balance deficit is not well specified by these tools. Computerized dynamic posturography (CDP) provides an objective assessment by isolating and quantifying sensory and motor contributions to balance control. The purpose of this study was to compare balance in individuals with PD to a control group using CDP (NeuroCom Smart Balance Master® system). Testing took place at the Southeast Parkinson's disease Research Education and Clinical Center (PADRECC), an interdisciplinary center of excellence for people with PD …
The Extraction Of Type Ii Collagen And The Electrospinning Of Nano-Fibrous Scaffolds, Danielle Careen Knapp
The Extraction Of Type Ii Collagen And The Electrospinning Of Nano-Fibrous Scaffolds, Danielle Careen Knapp
Theses and Dissertations
Articular cartilage lining joints, such as in the knee, functions to reduce friction and absorb shock. Collagen type II is the largest constituent in the extracellular matrix of articular cartilage and its restoration is of the highest interest to tissue engineers. Cartilage has little ability to naturally regenerate due to the absence of vascularity and the inability of the chondrocytes to proliferate at a high rate. It would be ideal to create a mimicking extracellular matrix/scaffold from type II collagen that could possibly be used to replace damaged articular cartilage that has the same function and morphology. Three different groups …
Joint Center Movement Analysis And 3d Motion Modeling Of Upper Arm - Comparison Of Several Algorithms With The Visual 3-D Program, Leena Joseph
Theses and Dissertations
600 out of every 100,000 people in the United States today suffer from some form of cerebellar disease that causes major abnormalities in the equilibrium and aligned, coordinated movement of the body. Hence it becomes essential to diagnose the extent of the movement and gait disorder and provide required therapy to the patients. Various developments have been made in the designing and application of interactive software system for body positioning. Object oriented design techniques are used in the field of software engineering for interactive geometric representation of system behavior. Motion analysis of the upper and lower extremities of the body …
Myocardial Perfusion Imaging With Rb-82 Pet, George Nittil Francis
Myocardial Perfusion Imaging With Rb-82 Pet, George Nittil Francis
Theses and Dissertations
Myocardial perfusion imaging (MPI) is an effective technique used to study the left ventricular ejection function (LVEF), myocardial perfusion, wall motion, and wall thickening. Positron emission tomography (PET) and single photon emission computed tomography (SPECT) are two modalities that can be used to quantify the left global and regional perfusion at rest and stress. While PET and SPECT rely on similar principles to produce images, important differences in instrumentation and experimental applications are dictated by inherent differences in their respective physics of radioactive decay. With a sensitivity > 90% in combination with a high specificity, PET is today the best available …
The Effects Of Parkinson's On Fixational Stability, Erin L. Mallahan
The Effects Of Parkinson's On Fixational Stability, Erin L. Mallahan
Theses and Dissertations
Parkinson's disease (PD) is a progressive, neurological movement disorder. The stability of eye movements in PD is not well understood but many patients report difficulty doing tasks that require stabilized fixation and gaze. The ability to stabilize an image on the retina is critical is acquiring visual information. The purpose of this study was to compare the stability of fixational eye movements of PD patients to those of age-matched controls. Eye movements during simple fixation tasks were recorded from 66 subjects (ages 52 to 84), and 36 age-matched controls (ages 58-85). The absolute velocity of the fixational eye movements were …
Iterative Methods For The Reconstruction Of Tomographic Images With Unconventional Source-Detector Configurations, Abey Mukkananchery
Iterative Methods For The Reconstruction Of Tomographic Images With Unconventional Source-Detector Configurations, Abey Mukkananchery
Theses and Dissertations
X-ray computed tomography (CT) holds a critical role in current medical practice for the evaluation of patients, particularly in the emergency department and intensive care units. Expensive high resolution stationary scanners are available in radiology departments of most hospitals. In many situations however, a small, inexpensive, portable CT unit would be of significant value. Several mobile or miniature CT scanners are available, but none of these systems have the range, flexibility or overall physical characteristics of a truly portable device. The main challenge is the design of a geometry that optimally trades image quality for system size. The goal of …
Real Time Frequency Analysis Of Signals From Lasso Catheter For Radiofrequency Ablation During Atrial Fibrillation, Prashant Yadav
Real Time Frequency Analysis Of Signals From Lasso Catheter For Radiofrequency Ablation During Atrial Fibrillation, Prashant Yadav
Theses and Dissertations
Real time spectrum analysis of signals obtained through lasso catheter during radiofrequency ablation of pulmonary vein was performed to determine the channel with dominant frequency. Threshold algorithm was used for signals which could be classified as type I and type II AF. Type III AF Signals which were highly fractionated or differentiated were evaluated for frequency content by performing Fast Fourier Transform. Data from Seven patients was collected and an episode of 180 ± 40 seconds was recorded and analyzed for each pulmonary vein that showed electrical activation. Frequency spectra for one second segment of signal for each channel were …
Electrospinning As A Processing Method For Electroactive Polymers And Composites, Kristin Joy Pawlowski
Electrospinning As A Processing Method For Electroactive Polymers And Composites, Kristin Joy Pawlowski
Theses and Dissertations
Electrospinning was examined for its potential to create functional materials. Three distinct electroactive materials were electrospun into fibers and fiber mats and then characterized with the intent of determining their utility in aerospace and biomedical applications such as micro-air vehicles and the cardiovascular system. Electrospun Graft Elastomers demonstrated potential as actuators, as electromechanical strain testing showed comparable response to the film form of this material. Further improvement of electroactive response was realized with high dielectric inclusions and fiber orientation. Electrospin processing imparted piezoelectric properties to the fibers of poly(vinylidene fluoride). Differential scanning calorimetry and infrared spectroscopy indicated a degree of …
Incorporation Of Tetracycline Hydrochloride Into Electrospun Fibrinogen: A Study Of Mechanical Properties And Time Release, Charles Dudley Anderson Jr.
Incorporation Of Tetracycline Hydrochloride Into Electrospun Fibrinogen: A Study Of Mechanical Properties And Time Release, Charles Dudley Anderson Jr.
Theses and Dissertations
Electrospinning has the capacity to create fibers of natural or synthetic polymers with dimensions that are similar to analogous fibers in native tissue. Mats consisting of fibers of these sub-micron dimensions have shown promise in provoking little immune response and in offering a habitable environment for cell proliferation. Fibrinogen is a natural protein capable of being electrospun and offers the benefit of existing as part of the natural coagulation cascade. Mats of fibrinogen could be utilized as possible hemostatic dressings or as an early scaffold for cell migration for either wound repair or tissue engineering. The addition of antibiotic into …
Novel Apparatus To Control Electrospinning Fiber Orientation For The Production Of Tissue Engineering Scaffolds, Eugene David Boland
Novel Apparatus To Control Electrospinning Fiber Orientation For The Production Of Tissue Engineering Scaffolds, Eugene David Boland
Theses and Dissertations
The conception of electrospinning can trace its roots back more than 400 years, when it was observed that rubbed amber can deform a droplet of water on a smooth surface, and is based upon simple concepts of charge separation and surface tension. Since that time, considerable effort has been directed at both the cause and utility of this phenomenon. The specific aim of this dissertation project was to develop an automated electrostatic processing apparatus that was capable of controlling the three-dimensional architecture of an electrospun scaffold to further improve its utility in tissue engineering. The efficacy of using this technique …
Evaluation Of Segmentation For Bone Structures In 3d Rendering Of Ultrasound Residual Limb Images, Min C. Baker
Evaluation Of Segmentation For Bone Structures In 3d Rendering Of Ultrasound Residual Limb Images, Min C. Baker
Theses and Dissertations
Prosthetists today widely practice manual socket fitting, which produces subjective, inconsistent results. To address this problem, the Computerized Anthropometry Research and Design (CARD) Laboratory is developing a computer-aided socket design system that acquires ultrasound datasets of an amputee's residual limb, creates a 3D model, and helps identify load- bearing and pressure-relief areas. This research project focuses on providing 3D visualization of a residual limb to support the CARD Laboratory's efforts. Creating the 3D model of the skin and two bone contours requires two major steps: segmentation to identify the objects of interest and a surface tracking algorithm to generate the …
Clustered Microcalcification Detection Using Optimized Difference Of Gaussians, Edward M. Ochoa
Clustered Microcalcification Detection Using Optimized Difference Of Gaussians, Edward M. Ochoa
Theses and Dissertations
The objective of this thesis is to design an automated microcalcification detection system to be used as an aid in radiologic mammogram interpretation. This research proposes the following methodology for clustered microcalcification detection. First, preprocess the digitized film mammogram to reduce digitization noise. Second, spatially filter the image with a difference of Gaussians (DoG) kernel. To detect potential microcalcifications, segment the filtered image using global and local thresholding. Next, cluster and index these detections into regions of interest (ROIs). Identify ROIs on the digitized image (or hardcopy printout) for final radiologic diagnosis.
Using Kriging To Interpolate Spatially Distributed Volumetric Medical Data, Stephen M. Matechik
Using Kriging To Interpolate Spatially Distributed Volumetric Medical Data, Stephen M. Matechik
Theses and Dissertations
Routine cases in diagnostic radiology require the interpolation of volumetric medical imaging data sets. Inaccurate renditions of interpolated volumes can lead to the misdiagnosis of a patient's condition. It is therefore essential that interpolated modality space estimates accurately portray patient space. Kriging is investigated in this research to interpolate medical imaging volumes. Kriging requires data to be spatially distributed. Therefore, magnetic resonance imaging (MRI) data is shown to exhibit spatially regionalized characteristics such that it can be modeled using regionalized variables and subsequently be interpolated using kriging. A comprehensive, automated, three-dimensional structural analysis of the MRI data is accomplished to …
Pulse Coupled Neural Networks For The Segmentation Of Magnetic Resonance Brain Images, Shane L. Abrahamson
Pulse Coupled Neural Networks For The Segmentation Of Magnetic Resonance Brain Images, Shane L. Abrahamson
Theses and Dissertations
This research develops an automated method for segmenting Magnetic Resonance (MR) brain images based on Pulse Coupled Neural Networks (PCNN). MR brain image segmentation has proven difficult, primarily due to scanning artifacts such as interscan and intrascan intensity inhomogeneities. The method developed and presented here uses a PCNN to both filter and segment MR brain images. The technique begins by preprocessing images with a PCNN filter to reduce scanning artifacts. Images are then contrast enhanced via histogram equalization. Finally, a PCNN is used to segment the images to arrive at the final result. Modifications to the original PCNN model are …
A New Device For Performing Simultaneous Sterno-Thoracic Cardiopulmonary Resuscitation (Sst-Cpr), Deepak S. Gupta
A New Device For Performing Simultaneous Sterno-Thoracic Cardiopulmonary Resuscitation (Sst-Cpr), Deepak S. Gupta
Theses and Dissertations
There are two different physiological mechanisms that cause blood to circulate around the human body during cardiopulmonary resuscitation. The "cardiac pump" generates blood flow by squeezing blood out of the heart as the sternum is depressed. The "thoracic pump" generates flow by forcing blood out of the heart and the great vessels as the intrathoracic pressure rises due to chest compression.
To date, all CPR techniques try to circulate blood during cardiac arrest by exploiting elite; the cardiac pump or the thoracic pump mechanism of blood flow. No mechanical CPR device thus far invented has tried to exploit both mechanisms …
Detection Of Clustered Microcalcifications Using Wavelets, Donald A. Mccandless
Detection Of Clustered Microcalcifications Using Wavelets, Donald A. Mccandless
Theses and Dissertations
An automated method for detecting microcalcification clusters is presented. The algorithm begins with a digitized mammogram and outputs the center coordinates of regions of interest (ROIs) that contain microcalcification clusters. The method presented uses a 12-tap Least Asymmetric Daubechies (LAD12) wavelet in a tree structured filter bank to increase the signal to noise level of microcalcifications. The signal to noise level gain achieved by the filtering allows subsequent thresholding to eliminate on average 90% of the image from further consideration without eliminating actual microcalcifications 95% of the time. A novel approach to isolating individual calcifications from background tissue through non-stationary …
Electroencephalography: Subdural Multi-Electrode Brain Chip, John E. Rosenstengel
Electroencephalography: Subdural Multi-Electrode Brain Chip, John E. Rosenstengel
Theses and Dissertations
In October 1995, a CMOS brain chip consisting of two 8 x 17 multiplexed sub-arrays designed to measure electrical potentials at the cortical column level, was implanted on the somatosensory cortex of a laboratory rhesus monkey. Electroencephalograph (EEG) and averaged evoked response (AEG) data were taken over a period of 40 minutes. The brain chip was replaced with an identical chip, and data were again taken for 40 minutes. In both instances AEG signals of approximately 150 µVpp were recorded. Additionally, the first implanted chip recorded three phases of data: (1) AEG; (2) large clock noise (during a period …