Open Access. Powered by Scholars. Published by Universities.®
Biomedical Engineering and Bioengineering Commons™
Open Access. Powered by Scholars. Published by Universities.®
- Discipline
-
- Biomechanics and Biotransport (49)
- Mechanical Engineering (45)
- Biomedical Devices and Instrumentation (42)
- Biomechanical Engineering (34)
- Medicine and Health Sciences (32)
-
- Life Sciences (30)
- Biological Engineering (28)
- Bioimaging and Biomedical Optics (21)
- Molecular, Cellular, and Tissue Engineering (21)
- Other Biomedical Engineering and Bioengineering (21)
- Physical Sciences and Mathematics (16)
- Biomaterials (15)
- Electrical and Computer Engineering (15)
- Medical Specialties (10)
- Biochemistry, Biophysics, and Structural Biology (9)
- Kinesiology (9)
- Bioelectrical and Neuroengineering (8)
- Biomechanics (8)
- Biomedical (7)
- Biology (6)
- Computer Engineering (6)
- Materials Science and Engineering (6)
- Medical Sciences (6)
- Microbiology (6)
- Analytical, Diagnostic and Therapeutic Techniques and Equipment (5)
- Bioresource and Agricultural Engineering (5)
- Chemical Engineering (5)
- Computer Sciences (5)
- Institution
- Keyword
-
- Daniel Felix Ritchie School of Engineering and Computer Science (84)
- Mechanical and Materials Engineering (46)
- Biomechanics (16)
- Center for Orthopaedic Biomechanics (7)
- Deep learning (7)
-
- Finite element analysis (7)
- Knee (7)
- Machine learning (7)
- Kinematics (6)
- Cancer (5)
- Electrical and Computer Engineering (5)
- Finite element (5)
- Microfluidics (5)
- Nanoparticles (5)
- Total knee arthroplasty (5)
- Computer Science (4)
- Fluoroscopy (4)
- Machine Learning (4)
- Medical imaging (4)
- Modeling (4)
- Orthopaedics (4)
- Total hip arthroplasty (4)
- Total knee replacement (4)
- Ultrasound (4)
- Artificial intelligence (3)
- Bacterial vaginosis (3)
- CFD (3)
- Computational fluid dynamics (3)
- Computational modeling (3)
- Hip fracture (3)
Articles 151 - 180 of 232
Full-Text Articles in Biomedical Engineering and Bioengineering
Investigating The Likelihood Of Pediatric Femur Fracture Due To Falls Through Finite Element Analysis., Keyonna Mckinsey
Investigating The Likelihood Of Pediatric Femur Fracture Due To Falls Through Finite Element Analysis., Keyonna Mckinsey
Electronic Theses and Dissertations
Bone fracture is the second most common injury of child abuse. Studies have generally reported that femur fractures are more likely due to abuse than accidental causes in cases where the child is non-ambulatory. They have also found that household falls are commonly offered as the cause of injury in cases of abuse. In this study, a finite element (FE) pediatric femur model will be developed and used to evaluate likelihood of fracture in common household fall scenarios (bed falls and feet first falls). This will provide greater biomechanical evidence as to the likelihood of femur fracture due to common …
Longitudinal Tracking Of Physiological State With Electromyographic Signals., Robert Warren Stallard
Longitudinal Tracking Of Physiological State With Electromyographic Signals., Robert Warren Stallard
Electronic Theses and Dissertations
Electrophysiological measurements have been used in recent history to classify instantaneous physiological configurations, e.g., hand gestures. This work investigates the feasibility of working with changes in physiological configurations over time (i.e., longitudinally) using a variety of algorithms from the machine learning domain. We demonstrate a high degree of classification accuracy for a binary classification problem derived from electromyography measurements before and after a 35-day bedrest. The problem difficulty is increased with a more dynamic experiment testing for changes in astronaut sensorimotor performance by taking electromyography and force plate measurements before, during, and after a jump from a small platform. A …
Plga-Modified Nanoparticles For The Treatment Of Hypo-Vascularized Hpv-Related Cervical Cancers., Lee B. Sims
Plga-Modified Nanoparticles For The Treatment Of Hypo-Vascularized Hpv-Related Cervical Cancers., Lee B. Sims
Electronic Theses and Dissertations
A major challenge associated with delivery of active agents in the female reproductive tract (FRT) is the ability of agents to efficiently diffuse through the cervicovaginal mucosa (CVM) and reach the underlying sub-epithelial immune cell layer and vasculature. A variety of drug delivery vehicles have been employed to improve the delivery of agents across the CVM and offer the capability to increase the longevity and retention of active agents to treat infections of the female reproductive tract. Nanoparticles (NPs) have been shown to improve retention, diffusion, and cell-specific targeting via specific surface modifications, relative to other delivery platforms. In particular, …
Design And Development Of A Multifunctional Surgical Device For Ground And Space-Based Surgical Applications., Brooke Elaine Barrow
Design And Development Of A Multifunctional Surgical Device For Ground And Space-Based Surgical Applications., Brooke Elaine Barrow
Electronic Theses and Dissertations
With the possibility of longer ventures into space, NASA will face many new medical challenges. The ability to surgically treat trauma and other disorders in reduced gravity requires reliable wound access, containment, and visualization. In collaboration with Carnegie Mellon University, the University of Louisville is currently developing the AISS (Aqueous Immersion Surgical System) to increase efficiency and control of the operative field in space-based surgeries. Reliable wound access and containment is achieved by placing a transparent wound-isolation dome securely over the wound-site and pressurizing it with a saline solution. Leak-free trocars provide access ports for various surgical instruments. This system …
Materials Design With Polylactic Acid-Polyethylene Glycol Blends Using 3d Printing And For Medical Applications., Jeremiah R. Bauer
Materials Design With Polylactic Acid-Polyethylene Glycol Blends Using 3d Printing And For Medical Applications., Jeremiah R. Bauer
Electronic Theses and Dissertations
This thesis is an examination of two material systems derived from polylactic acid (PLA) and polyethylene glycol (PEG). PLA is a polymer commonly sourced from renewable sources such as starches and sugars. It is a relatively strong, biodegradable polymer, making it ideal for use in the body. Even though it has a relative high strength, PLA is also brittle leading to the use of plasticizers to increase flexibility. One such plasticizer is PEG, which is a material that can exist at room temperature as either a thin liquid, or a hard waxy solid depending on the molecular weight. The first …
Tumor-Targeted Double Emulsions For Ultrasound-Triggered Delivery Of Molecular Therapeutics., Connor S Centner
Tumor-Targeted Double Emulsions For Ultrasound-Triggered Delivery Of Molecular Therapeutics., Connor S Centner
Electronic Theses and Dissertations
Cancer is the second leading cause of death in the United States, with 1.74 million new cancer cases diagnosed and 610,000 cancer deaths expected in 2018 alone. Current treatments often result in negative systemic effects and ineffective treatment of the tumor. Drug delivery vehicles have been developed for more effective local delivery methods, but many drug delivery vehicles lack spatial and temporal control. Targeted double emulsions are a new class of drug delivery vehicles which present a promising option for a high payload and controlled delivery. The purpose of our project was to develop and characterize an aptamer-chelated double emulsion …
Development Of Low Frequency Electron Paramagnetic Resonance Methods And Instrumentation For Biological Applications, Laura A. Buchanan
Development Of Low Frequency Electron Paramagnetic Resonance Methods And Instrumentation For Biological Applications, Laura A. Buchanan
Electronic Theses and Dissertations
EPR is a powerful biophysical tool that can be used to measure tumor physiology. With the addition of magnetic field gradients, the spectral properties of paramagnetic species can be mapped. To facilitate EPR imaging, methods and instrumentation at frequencies between 250 MHz and 1 GHz were developed.
At low spin concentrations, the rapid scan background signal is often many times larger than the EPR signal of interest. To help remove the background contribution, a data acquisition procedure that takes advantage of a cross-loop resonator and bipolar power supplies was developed at 250 MHz. In this procedure, two scans are collected. …
Probing The Effects Of Substrate Stiffness On Astrocytes Mechanics, Ariege Bizanti
Probing The Effects Of Substrate Stiffness On Astrocytes Mechanics, Ariege Bizanti
Electronic Theses and Dissertations
Astrocytes are among the most functionally diverse population of cells in the central nervous system (CNS) as they are essential to many important neurological functions including maintaining brain homeostasis, regulating the blood brain barrier, and preventing build-up of toxic substances within the brain, for example. Astrocyte importance to brain physiology and pathology has inspired a host of studies focused on understanding astrocyte behavior primarily from a biological and chemical perspective. However, a clear understanding of astrocyte dysfunction and their link to disease has been hampered by a lack of knowledge of astrocyte behavior from a biomechanical perspective. Furthermore, astrocytes (and …
Restoring Cholesterol Homeostasis In Familial Hypercholesterolemia Cell Line Model, Lubna Hindi
Restoring Cholesterol Homeostasis In Familial Hypercholesterolemia Cell Line Model, Lubna Hindi
Electronic Theses and Dissertations
Familial hypercholesterolemia (FH) is an autosomal dominant disorder that results in elevated levels of low-density lipoprotein cholesterol (LDL-C). This increase in serum cholesterol level has been shown to result in premature coronary artery disease (CAD) with devastating symptoms from a young age. Today, the prevalence of heterozygous FH (HeFH) and homozygous FH (HoFH) is estimated to be 1 in 320 and 1 in 160,000 people, respectively. FH is referred to as an underdiagnosed disease due to the large number of mutations that continues to grow. These mutations often exist in one of or a combination of three genes: low-density lipoprotein …
Lcd 3d Printing Of A Photocurable Elastomer For Tissue Engineering, Beatriz Luiza De Souza
Lcd 3d Printing Of A Photocurable Elastomer For Tissue Engineering, Beatriz Luiza De Souza
Electronic Theses and Dissertations
Three-dimensional scaffolding is an emerging research area in biomedical and tissue engineering. Scaffolds provide the possibility of growing tissues in a controlled environment, with desired characteristics and properties towards a specific application. A new method to 3D print biodegradable and biocompatible material called Polyglycerol Sebacate Acrylate (PGSA) is demonstrated. PGSA is essentially an acrylated form of PGS using photoinitiator to become a photocurable resin suitable for liquid crystal display (LCD) 3D printing. PGSA was selected because its rheological and crosslinking behavior (and hence its mechanical properties) can be controlled by changes in curing time, temperature, and pressure. This material has …
Optimization Of Plga And Plga-Dasatinib Particles Through A Taguchi Design Approach, Rayeanne N Balgemann
Optimization Of Plga And Plga-Dasatinib Particles Through A Taguchi Design Approach, Rayeanne N Balgemann
Electronic Theses and Dissertations
Proliferative vitreoretinopathy (PVR) is a disease of the retina in the human eye. Retinal pigment epithelium cells (RPE) undergo an epithelial to mesenchymal transition in response to retinal trauma. This transition gives the cells mobility and allows them to potentially infiltrate the vitreous chamber and deposit on either side of the retina. Once cell deposition has occurred, along with several other transformed cells derived from cell types such as Müller glia, these migratory cells can form a membrane contiguous with the retinal extracellular matrix and, upon contraction, cause wrinkling of the retina. If left untreated PVR can lead to traction …
Predictive Modeling Of Hip Dislocation: Assessment Of Surgical And Patient Factors To Reduce The Occurrence Of Hip Instability And Adverse Clinical Outcomes, Daniel N. Huff
Electronic Theses and Dissertations
Instability and dislocation remain leading indications for revision of primary Total Hip Arthroplasty (THA). Many studies have addressed the links between implant design and propensity for dislocation, however a comprehensive review of the ability of modern THA constructs to protect against joint instability is needed.
Accordingly, the objective of this study is to provide objective data about THA risks to be considered in the treatment algorithm to protect against adverse joint loading conditions and joint instability. Adverse loading conditions were assessed in a population of activities of daily living using data from telemetric hip implant representation in an FE simulation …
Cementless Tibial Base Micromotion During Activities Of Daily Living, Hayden Wilson
Cementless Tibial Base Micromotion During Activities Of Daily Living, Hayden Wilson
Electronic Theses and Dissertations
Initial stability of cementless total knee replacement (TKR) components is directly related to long-term fixation and success, as excess motion hinders bony ingrowth. To assess implant stability, there is a need for more physiologically accurate loading conditions, incorporating forces and displacements in all 6 degrees-of-freedom found in the knee joint, as well as understanding the impact of femoral flexion on conformity of tibiofemoral articulation. Understanding how different activities of daily living generate tibial micromotion yields insight into surgical technique considerations, and rehabilitation strategies post-operatively. ASTM F3141-15, which specifies knee flexion, Internal-External moment, Medial-Lateral, Anterior-Posterior and Superior-Inferior forces during gait and …
Computational Modeling Of Transcatheter Aortic Valves, Mostafa Abbasi
Computational Modeling Of Transcatheter Aortic Valves, Mostafa Abbasi
Electronic Theses and Dissertations
Transcatheter aortic valve replacement (TAVR) is an established therapy alternative to surgical valve replacement in high-risk and intermediate-risk patients with severe aortic stenosis. Currently, although TAVR is an alternative and less-invasive treatment for high-risk and intermediate-risk patients, surgical aortic valves replacement (SAVR) was still considered as the gold standard for low-risk patients. TAVR could potentially be applied to lower-risk younger patients if the indications can be safely expanded to the patients and transcatheter aortic valve (TAV) long-term durability can match with that of surgical bioprostheses. In contrast to surgical aortic valves (SAVs), there have been limited clinical data on the …
Design, Development, And Characterization Of Breathforce : A Respiratory Training System For Patients With Spinal Cord Injuries., Kevin L Tran
Electronic Theses and Dissertations
Pulmonary and cardiovascular dysfunction are consistently reported as the leading causes of morbidity and mortality among the 1,275,000 people who are living with chronic spinal cord injury (SCI) in the United States. Respiratory-cardiovascular complications from neurological disorders (primarily COPD and sleep apnea) are currently the number one cause of death and disability in the US.
The main goal of this project is to develop an inspiratory-expiratory training device for use in the rehabilitation of patients with respiratory motor and cardiovascular deficits that incorporates existing technologies and promotes successful training methodologies performed at the clinic and at home.
An embedded microprocessor …
Material Properties Design Using Simulations And Experiments For Powder Injection Molding Of Lead Zirconate Titanate (Pzt)., Bhushan Pramod Bandiwadekar
Material Properties Design Using Simulations And Experiments For Powder Injection Molding Of Lead Zirconate Titanate (Pzt)., Bhushan Pramod Bandiwadekar
Electronic Theses and Dissertations
Powder injection molding (PIM) process simulations can be performed to minimize the number of injection molding experiments by estimating material properties necessary for PIM simulations. In current work, lead zirconate titanate (PZT) powder-polymer binder feedstock was compounded for 45 vol. % and 52 vol. % solids loading. PIM experiments on designed micro-pillar array geometry were performed using 52 vol. % PZT. Using PIM experiments results as basis, PIM simulations were performed on designed micro-pillar array geometries to understand the effectiveness of PIM simulations with the use of estimated feedstock properties in predicting molding behavior that have micro-features. Additionally, PIM simulations …
A Novel Approach To Assess Minimally Invasive Surgical Device Failure Utilizing Adverse Event Outcome Severity And Design Complexity., Marie K. Riggs
A Novel Approach To Assess Minimally Invasive Surgical Device Failure Utilizing Adverse Event Outcome Severity And Design Complexity., Marie K. Riggs
Electronic Theses and Dissertations
Medical device failure and misuse have the potential to cause serious injury and death. Given the intricate nature of the instruments utilized specifically in minimally invasive surgery (MIS), users and manufacturers of surgical devices share a responsibility in preventing user error and device failure. A novel approach was presented for the evaluation of minimally invasive device failures, which involved assessing the severity of adverse event outcomes associated with the failures modes and investigating aspects of the devices’ design that may contribute to failure. The goals of this research were to 1) characterize the design attributes, failure modes, and adverse events …
Custom Software For The 3d Printing Of Patient Specific Plate Bending Templates In Pelvic Fracture Repair., Gordon B Lents
Custom Software For The 3d Printing Of Patient Specific Plate Bending Templates In Pelvic Fracture Repair., Gordon B Lents
Electronic Theses and Dissertations
The purpose of this work is to reduce the operative time and blood loss incurred during open reduction and internal fixation (ORIF) of traumatic pelvic injuries through the creation of patient specific bending templates for reconstruction plates. These templates are 3D printed in a resin capable of being sterilized and taken into the operating room so that bending may be performed by the surgeon before the patient is opened or by another team member in parallel with the surgeon.
A novel software extension was created in 3D modeling software to allow a surgeon to individually position screws on a pelvic …
Biomechanical Testing Of An Exercise For Strengthening The Proximal Femur., Alyssa Osbourne
Biomechanical Testing Of An Exercise For Strengthening The Proximal Femur., Alyssa Osbourne
Electronic Theses and Dissertations
Based on the principles of cutting edge bone remodeling research, a unique therapeutic exercise device was designed specifically to improve bone quality at the most critical location of the proximal femur prone to fracture: the superior-lateral femoral neck where the fracture first initiates during a fall. The exercise/device is intended to work by inducing enough strain in the bone to stimulate the body’s natural bone remodeling mechanisms to increase bone density in the proximal femur and consequently prevent a fracture from arising if a fall to the side does occur.
In order to test the proposed exercise, experiments simulating the …
Examining The Effects Of Macrophage Populations On Cancerous Tumor Growth., Grace E. Mahlbacher
Examining The Effects Of Macrophage Populations On Cancerous Tumor Growth., Grace E. Mahlbacher
Electronic Theses and Dissertations
The most abundant immune cell types of the tumor microenvironment macrophages recruited there by tumor-eluted factors. The role of these immune cells in tumor progression, and the interplay between tumor and immune cells is an emerging field of research with potential for novel treatment strategies. Here, a TIE2 expressing macrophage (TEM) subtype is integrated into a virtual tumor model. Within the 2D microenvironment, the TEM will differentiate from an extravasated monocyte precursor, congregate around the abluminal side of the vasculature in response to a chemoattractant gradient, secrete cytokines which favor differentiation of a separate angiogenic macrophage subtype [1]. The effects …
A Novel Mra-Based Framework For The Detection Of Changes In Cerebrovascular Blood Pressure., Yitzhak Atakilt Gebru
A Novel Mra-Based Framework For The Detection Of Changes In Cerebrovascular Blood Pressure., Yitzhak Atakilt Gebru
Electronic Theses and Dissertations
Background: High blood pressure (HBP) affects 75 million adults and is the primary or contributing cause of mortality in 410,000 adults each year in the United States. Chronic HBP leads to cerebrovascular changes and is a significant contributor for strokes, dementia, and cognitive impairment. Non-invasive measurement of changes in cerebral vasculature and blood pressure (BP) may enable physicians to optimally treat HBP patients. This manuscript describes a method to non-invasively quantify changes in cerebral vasculature and BP using Magnetic Resonance Angiography (MRA) imaging.
Methods: MRA images and BP measurements were obtained from patients (n=15, M=8, F=7, Age= 49.2 …
Development Of A Directional Bone Reaming System., Richard J Ackermann
Development Of A Directional Bone Reaming System., Richard J Ackermann
Electronic Theses and Dissertations
Preparation of long bones such as the femur or tibia for placement of intramedullary devices for the treatment of fractures usually involves reaming with a series of central cutters driven by a drill-like device with a flexible shaft over a guide wire. The reamers sequentially enlarge the intramedullary canal into a tunnel of circular cross-section and a diameter appropriate for the procedure. The current technology is concentric, meaning that the system is self-centering within the original intramedullary canal and the expansion is symmetric with respect to the original centerline. A novel system for laterally deflecting the head of a 12mm …
Development And Evaluation Of A Biocompatible Electroactive Sensor For Continuous Blood Pressure Measurement., Scott D. Cambron
Development And Evaluation Of A Biocompatible Electroactive Sensor For Continuous Blood Pressure Measurement., Scott D. Cambron
Electronic Theses and Dissertations
Piezo-active composites have been implemented for sensing and transduction for decades. The 0-3 ceramic/polymer composite is one of the most common composite types used for sensing applications, owing to their tailorable properties of the two-phase composition, consisting of a three-dimensionally connected polymer/rubber matrix (inactive phase) with a dispersion of isolated piezo-ceramic particles (active phase). This thesis describes a method to develop novel biocompatible perivascular band comprised of a two-phase piezo-active composite to be fabricated using simple manufacturing processes. Biomaterials such as tissue scaffolds comprised of silk fibroin (SF) and chitosan (CS), and biocompatible soft rubbers will be implemented as the …
Computer-Aided Cancer Diagnosis And Grading Via Sparse Directional Image Representations, Hadi Rezaeilouyeh
Computer-Aided Cancer Diagnosis And Grading Via Sparse Directional Image Representations, Hadi Rezaeilouyeh
Electronic Theses and Dissertations
Prostate cancer and breast cancer are the second cause of death among cancers in males and females, respectively. If not diagnosed, prostate and breast cancers can spread and metastasize to other organs and bones and make it impossible for treatment. Hence, early diagnosis of cancer is vital for patient survival. Histopathological evaluation of the tissue is used for cancer diagnosis. The tissue is taken during biopsies and stained using hematoxylin and eosin (H&E) stain. Then a pathologist looks for abnormal changes in the tissue to diagnose and grade the cancer. This process can be time-consuming and subjective. A reliable and …
Mechanical Effects Of Surgical Adhesives On Ascending Thoracic Aortic Aneurysm Replacement, Dong Qiu
Mechanical Effects Of Surgical Adhesives On Ascending Thoracic Aortic Aneurysm Replacement, Dong Qiu
Electronic Theses and Dissertations
Ascending thoracic aortic aneurysm (aTAA) is a potentially lethal disease which grows gradually over time and may lead to aortic dissection and rupture. Currently, aTAA surgical repair using Dacron graft is a well-established treatment. In addition, surgical adhesives are frequently used in the surgeries to seal the anastomotic site. This study aims to investigate mechanical effects of four commonly used surgical adhesives, namely BioGlue, CoSeal, Crosseal, and Tisseel, on the suture site using in-vitro digital image correlation (DIC) method and finite element (FE) simulations in an ovine model. In this study, first, mechanical properties of ovine ascending aorta were obtained …
Development Of Highly Sensitive And Selective Breathing Sensors Using Molecular Imprinted Filtering For Diabetic And Alcoholic Patients, Md. Saleh Akram Bhuiyan
Development Of Highly Sensitive And Selective Breathing Sensors Using Molecular Imprinted Filtering For Diabetic And Alcoholic Patients, Md. Saleh Akram Bhuiyan
Electronic Theses and Dissertations
Wellness sensor technology is an emerging diagnostic test research field, which mostly deal with the point of care of the patients in the recent days. Due to the lack of awareness from the patients, most diseases cannot be detected in due time. This led to worse conditions, such as diabetic and alcoholic syndrome. Therefore, many research groups have been working to develop portable sensor devices that can track serious diseases. These include diabetic and alcoholic biomarkers in breathing. These devices have very high selectivity and reliability. However, the major limitation of biomarkers is that it deals with the bio-molecular based …
3d Bioprinting Hydrogel For Tissue Engineering An Ascending Aortic Scaffold, Benjamin Stewart
3d Bioprinting Hydrogel For Tissue Engineering An Ascending Aortic Scaffold, Benjamin Stewart
Electronic Theses and Dissertations
The gold standard in 2016 for thoracic aortic grafts is Dacron®, polyethylene terephthalate, due to the durability over time, the low immune response elicited and the propensity for endothelialization of the graft lumen over time. These synthetic grafts provide reliable materials that show remarkable long term patency. Despite the acceptable performance of Dacron® grafts, it is noted that autographs still outperform other types of vascular grafts when available due to recognition of the host's cells and adaptive mechanical properties of a living graft. 3-D bioprinting patient-specific scaffolds for tissue engineering (TE) brings the benefits of non-degrading synthetic …
Segmental Movement Compensations In Patients With Transtibial Amputation Identified Using Angular Momentum Separation, Brecca M. M. Gaffney
Segmental Movement Compensations In Patients With Transtibial Amputation Identified Using Angular Momentum Separation, Brecca M. M. Gaffney
Electronic Theses and Dissertations
Patients with unilateral dysvascular transtibial amputation (TTA) adopt movement compensations that are required to maintain balance and achieve ambulation in the absence of ankle plantar flexion, and result in increased and asymmetric joint loading patterns. As a result, this population is at an increased risk of overuse injuries, such as low back pain (LBP). Clinical gait analysis is used to guide diagnostics in movement retraining following amputation, and is performed using instrumented (research based) or observational analyses (clinically based). However, instrumented analyses are currently impractical in most clinical settings due to expense and computational limitations. This dissertation presents the use …
Statistical Shape Modeling To Quantify Variation In The Proximal Humeral Anatomy, Paul B. Sade Sr.
Statistical Shape Modeling To Quantify Variation In The Proximal Humeral Anatomy, Paul B. Sade Sr.
Electronic Theses and Dissertations
The fit of the humeral prosthesis to the intramedullary canal and the replication of the anatomic humeral head center are important factors in Total Shoulder Arthroplasty (TSA). The objective of this thesis was to develop a Statistical Shape Model (SSM) of the cortical and cancellous bone regions of the proximal humerus, and to assess potential shape differences with gender and ethnicity, with a goal of informing implant design. An SSM was used and Principal Component Analysis (PCA) was applied to data that represented both the cancellous and cortical humeral bone of 63 healthy subjects and cadavers. Anatomical measurements and PC …
Six Degrees Of Freedom: Kinematics Of The Healthy Ankle Syndesmosis Joint, Veronica A. Hogg-Cornejo
Six Degrees Of Freedom: Kinematics Of The Healthy Ankle Syndesmosis Joint, Veronica A. Hogg-Cornejo
Electronic Theses and Dissertations
Syndesmotic injury, more commonly known as a "high ankle sprain", accounts for over 12% of all ankle sprain incidents in the US; of which, over 25% occur during a sporting activity. Typically, harm to the syndesmosis occurs in sports such as football, soccer, lacrosse, and hockey where it is common for an athlete to experience rapid and extreme dorsiflexion-external rotations of the foot. Severe syndesmotic sprains have been noted by clinicians as the most difficult ankle injury to accurately diagnose and treat, require the most recuperation time, and often results in life-long dysfunction. Even more problematic, 40% of patients suffering …