Open Access. Powered by Scholars. Published by Universities.®
Biomedical Engineering and Bioengineering Commons™
Open Access. Powered by Scholars. Published by Universities.®
- Discipline
- Keyword
-
- Drug delivery (14)
- Electrospun fibers (12)
- Biomaterials (8)
- Astrocyte (6)
- Spinal cord injury (6)
-
- Nanomedicine (5)
- Silica nanoparticles (5)
- Astrocytes (4)
- Dendrimer (4)
- Dorsal root ganglia (4)
- Hydrogel (4)
- Inflammation (4)
- Iron oxide nanoparticles (4)
- Scaffold (4)
- Biodegradation (3)
- Chitosan (3)
- Coating (3)
- Curcumin (3)
- Electrospinning (3)
- Electrospun fiber (3)
- Glaucoma (3)
- Hydrogels (3)
- Macrophage (3)
- Magnesium (3)
- Nanoparticle (3)
- Neuroprotection (3)
- Poly- l -lactic acid (3)
- Poly-l-lactic acid (3)
- Tissue engineering (3)
- Aligned microfibers (2)
Articles 181 - 210 of 247
Full-Text Articles in Biomedical Engineering and Bioengineering
Aluminium-Free Glass Polyalkenoate Spinal Cements, A. W. Wren, N. M. Cummins, Mark R. Towler
Aluminium-Free Glass Polyalkenoate Spinal Cements, A. W. Wren, N. M. Cummins, Mark R. Towler
Chemical and Biochemical Engineering Faculty Research & Creative Works
Addition of Yitanium increased the Wt & St and the sf strength of these cements compared to the control (BT 101). © 2011 IEEE.
Fabrication And Characterization Of A Hydrogel Containing Electrospun Fibers, C. J. Rivet, R. J. Gilbert
Fabrication And Characterization Of A Hydrogel Containing Electrospun Fibers, C. J. Rivet, R. J. Gilbert
Chemical and Biochemical Engineering Faculty Research & Creative Works
Electro spun an fibers hydrogels are two focal points of research within the biomaterial's community. The electrospinning process allows for fabrication of nanoscale, aligned topography and has been shown to direct cellular migration and outgrowth. Hydrogels exhibit benefits over traditional, rigid scaffolds in that they are injectable and can be tailored to mimic the mechanical properties of the surrounding tissue. Although both electro spun fibers and hydrogels display favorable characteristics for biomedical applications in vitro, there in vivo benefits are limited due to inherent deficiencies Therefore, to advance the field of biomaterials research, a composite material containing electro spun fibers …
The Effect Of Adding Organic Polymers To Ca-Sr-Zn-Si Glass Polyalkenoate Cement, A. Coughlan, N. M. Cummins, A. W. Wren, Mark R. Towler
The Effect Of Adding Organic Polymers To Ca-Sr-Zn-Si Glass Polyalkenoate Cement, A. Coughlan, N. M. Cummins, A. W. Wren, Mark R. Towler
Chemical and Biochemical Engineering Faculty Research & Creative Works
To conclude, the addition of polymers to GPCs resulted in little change to the Tw and Ts, however the compressive strength was found to decrease slightly. ASAP tests revealed that the cements may undergo some structural changes as a result of these additions. In the future perhaps the addition of organic polymers suspended in the liquid phase as part of the cement may yield improved results in this type of study. © 2011 IEEE.
Fabrication And Analysis Of Variable Density Poly-(L)-Lactic Acid Fiber Scaffolds, N. W. Zaccor, C. J. Rivet, R. J. Gilbert
Fabrication And Analysis Of Variable Density Poly-(L)-Lactic Acid Fiber Scaffolds, N. W. Zaccor, C. J. Rivet, R. J. Gilbert
Chemical and Biochemical Engineering Faculty Research & Creative Works
Poly-L-lactic acid (PLLA) is an extensively studied synthetic polymer that has demonstrated utility as a scaffolding material. A common technique for the fabrication of PLLA scaffolds is electrospinning. The purpose of the present material study was to assess whether an electrospinning process could produce consistent and uniform PLLA scaffold densities. An 8% PLLA solution was made using a 1:1 chloroform: dichloromethane solution and was then run through an electrospinning apparatus. Samples were spun onto 4% PLLA films for 2- or 20-min. Scanning electron microscopy (SEM) was used for imaging the scaffolds. A nine-measurement data set was used for the assessment …
Aligned, Electrospun Topography For Use With External Stimulus Systems, S. G. Quallich, C. J. Rivet, R. J. Gilbert
Aligned, Electrospun Topography For Use With External Stimulus Systems, S. G. Quallich, C. J. Rivet, R. J. Gilbert
Chemical and Biochemical Engineering Faculty Research & Creative Works
Variations in fiber density, diameter, and orientation can be used to direct cell migration and guide neurite growth. The characterization of electro spun fibers is essential prior to conducting further research that utilizes electro spun scaffolds to control the magnitude and direction of cell migration and neurite growth. The goal of this study is to create highly aligned, electro spun fibers on poly-L-lactic acid (PLLA) films in parallel and perpendicular orientations to the long axis of rectangular cover slips. Fibers were electro spun into scaffolds and scanning electron microscopy (SEM) was used to characterize fiber density and orientation. The construction …
Using Cerebrospinal Fluid For In Situ Fabrication Of Injectable Alginate Hydrogels For Spinal Cord Repair, C. A. Mckay, R. J. Gilbert
Using Cerebrospinal Fluid For In Situ Fabrication Of Injectable Alginate Hydrogels For Spinal Cord Repair, C. A. Mckay, R. J. Gilbert
Chemical and Biochemical Engineering Faculty Research & Creative Works
Severe mechanical trauma of the spinal cord induces a secondary injury response that contributes to post injury cell death and the formation of barriers inhibitory to neuronal regeneration. It is believed that engineered scaffolds produce favorable results when they mimic the properties of the t issue that they are aiming to replicate. Alginate hydrogels have been shown to be beneficial in a number of biomaterial applications and this study shows that alginate hydrogels formed in the presence of an artificial cerebrospinal fluid are able to form hydrogels with mechanical properties similar to those exhibited by neural tissue in the CNS. …
Decreasing The Gelation Time Of Fibrin Hydrogels, C. D. Johnson, J. Zudiema, R. J. Gilbert
Decreasing The Gelation Time Of Fibrin Hydrogels, C. D. Johnson, J. Zudiema, R. J. Gilbert
Chemical and Biochemical Engineering Faculty Research & Creative Works
Spinal cord injury (SCI) is a debilitating problem that often results in paraplegia or quadriplegia. Fibrin hydrogels can be injected into the injured cavity and fill the irregular space. Current techniques require 60 minutes to form a hydrogel. The purpose of this study was to design a fibrin biomaterial that would solidify at a faster rate. By augmenting the existing fabrication procedure, a novel biomaterial was created that formed in 5-7 minutes but lost much of its mechanical stability. Further studies will be performed to improve the mechanical properties while maintaining the faster rate of formation observed here. © 2011 …
Leaching Of Potential Hazardous Elements Of Coal Cleaning Rejects, Luis F.O. Silva, Maria Izquierdo, Xavier Querol, Robert B. Finkelman, Marcos L.S. Oliveira, Marcus Wollenschlager, Mark R. Towler, Rafael Pérez-López, Felipe Macias
Leaching Of Potential Hazardous Elements Of Coal Cleaning Rejects, Luis F.O. Silva, Maria Izquierdo, Xavier Querol, Robert B. Finkelman, Marcos L.S. Oliveira, Marcus Wollenschlager, Mark R. Towler, Rafael Pérez-López, Felipe Macias
Chemical and Biochemical Engineering Faculty Research & Creative Works
The geochemical characteristics of coal cleaning rejects (CCR) in Santa Catarina State, Brazil, were investigated. Around 3.5 million ton/ year of coal waste are dumped in Santa Catarina State. Coal beneficiation by froth flotation results in large amounts of CCR composed of coaly and mineral matter, the latter characterized by the occurrence of sulphide minerals and a broad array of leachable elements. The total and leachable contents of more than 60 elements were analyzed. Atmospheric exposure promotes sulphide oxidation that releases substantial sulphate loads as well as Ca2+, K+, Mg2+, Cl- and Al3+ …
Synthesis Of Latex Based Antibacterial Acrylate Polymer/Nanosilver Via In Situ Miniemulsion Polymerization, Mostafa Yazdi Mamaghani, Malihe Pishvaei, Babak Kaffashi
Synthesis Of Latex Based Antibacterial Acrylate Polymer/Nanosilver Via In Situ Miniemulsion Polymerization, Mostafa Yazdi Mamaghani, Malihe Pishvaei, Babak Kaffashi
Chemical and Biochemical Engineering Faculty Research & Creative Works
Silver nanoparticles were incorporated into poly-{methyl methacrylate-butyl acrylate-acrylic acid} using two different approaches. The first approach was based on dispersing the nano silver particles in acrylic latex (previously synthesized by the emulsion polymerization) and the second is the in-situ polymerization of acrylate monomers in the presence of silver nanoparticles by Mini emulsion polymerization. Mini emulsion polymerization can yield a better dispersion of nano silver in the polymeric particles because organic particles can be dispersed directly in the monomer droplets becoming encapsulated upon polymerization. Morphological investigations were performed using SEM and TEM. FTIR and thermal analyses revealed the silver nanoparticles to …
The Structural Role Of Titanium In Ca-Sr-Zn-Si/Ti Glasses For Medical Applications, A. W. Wren, F. R. Laffir, A. Kidari, Mark R. Towler
The Structural Role Of Titanium In Ca-Sr-Zn-Si/Ti Glasses For Medical Applications, A. W. Wren, F. R. Laffir, A. Kidari, Mark R. Towler
Chemical and Biochemical Engineering Faculty Research & Creative Works
Glasses for medical applications are used in particulate form or as a cement component. This work was undertaken to determine structural changes in 0.48SiO2-0.36ZnO-0.12CaO-0.04SrO glass when the SiO2 is substituted with 5 mol% increments of TiO2. X-ray Diffraction (XRD) was used to determine the presence of crystallinity. This occurred after additions of 20 mol% TiO2. Differential Thermal Analysis (DTA) and Network connectivity (NC) calculations determined that by increasing the TiO2 content, the Tg and NC reduced (Tg 670 °C to 632 °C, NC 1.83 to -1.14) suggesting that TiO2 acts as …
The Bioactivity And Ion Release Of Titanium-Containing Glass Polyalkenoate Cements For Medical Applications, A. W. Wren, N. M. Cummins, F. R. Laffir, S. P. Hudson, Mark R. Towler
The Bioactivity And Ion Release Of Titanium-Containing Glass Polyalkenoate Cements For Medical Applications, A. W. Wren, N. M. Cummins, F. R. Laffir, S. P. Hudson, Mark R. Towler
Chemical and Biochemical Engineering Faculty Research & Creative Works
The ion release profiles and bioactivity of a series of Ti containing glass polyalkenoate cements. Characterization revealed each material to be amorphous with a Tg in the region of 650-660°C. The network connectivity decreased (1.83-1.35) with the addition of TiO2 which was also evident with analysis by X-ray photoelectron spectroscopy. Ion release from cements were determined using atomic absorption spectroscopy for zinc (Zn2+), calcium (Ca2+), strontium (Sr2+), Silica (Si4+) and titanium (Ti4+). Ions such as Zn2+ (0.1-2.0 mg/l), Ca2+ (2.0-8.3 mg/l,) Sr2+ (0.1-3.9 mg/l), and Si4+ …
The Response Of Pseudomonas Aeruginosa Biofilm To The Presence Of A Glass Polyalkenoate Cement Formulated From A Silver Containing Glass, A. Coughlan, M. P. Ryan, N. M. Cummins, Mark R. Towler
The Response Of Pseudomonas Aeruginosa Biofilm To The Presence Of A Glass Polyalkenoate Cement Formulated From A Silver Containing Glass, A. Coughlan, M. P. Ryan, N. M. Cummins, Mark R. Towler
Chemical and Biochemical Engineering Faculty Research & Creative Works
No abstract provided.
The Effect Of Ionic Dissolution Products Of Ca-Sr-Na-Zn-Si Bioactive Glass On In Vitro Cytocompatibility, S. Murphy, A. W. Wren, Mark R. Towler, D. Boyd
The Effect Of Ionic Dissolution Products Of Ca-Sr-Na-Zn-Si Bioactive Glass On In Vitro Cytocompatibility, S. Murphy, A. W. Wren, Mark R. Towler, D. Boyd
Chemical and Biochemical Engineering Faculty Research & Creative Works
Many commercial bone grafts cannot regenerate healthy bone in place of diseased bone. Bioactive glasses have received much attention in this regard due to the ability of their ionic dissolution products to promote cell proliferation, cell differentiation and activate gene expression. Through the incorporation of certain ions, bioactive glasses can become therapeutic for specific pathological situations. Calcium-strontium-sodium-zinc-silicate glass bone grafts have been shown to release therapeutic levels of zinc and strontium, however the in vitro compatibility of these materials is yet to be reported. In this study, the in vitro cytocompatibility of three different calcium-strontium-sodium-zinc-silicate glasses was examined as a …
Comparison Of Antibacterial Properties Of Commercial Bone Cements And Fillers With A Zinc-Based Glass Polyalkenoate Cement, A. W. Wren, N. M. Cummins, Mark R. Towler
Comparison Of Antibacterial Properties Of Commercial Bone Cements And Fillers With A Zinc-Based Glass Polyalkenoate Cement, A. W. Wren, N. M. Cummins, Mark R. Towler
Chemical and Biochemical Engineering Faculty Research & Creative Works
Postoperative infection following invasive surgical procedures is a significant cause for concern, particularly in spinal reconstructive surgery. The objective of this study is to compare the antibacterial efficacy of a novel zinc-based glass polyalkenoate cement (Zn-GPC) based on 0.04SrO-0.12CaO-0.36ZnO- 0.48SiO2 glass, to a number of commercially available bone cements and fillers including Simplex P + Tobramycin (STob), Spineplex (Spine) and Novabone Putty (NPut). The agar diffusion test was performed on each material against Escherichia coli, Staphlococcus epidermidis, Pseudomonas aeruginosa and Staphlococcus Aureus. STob was found to produce large inhibition zones in each …
A Spectroscopic Investigation Into The Setting And Mechanical Properties Of Titanium Containing Glass Polyalkenoate Cements, A. W. Wren, A. Kidari, N. M. Cummins, Mark R. Towler
A Spectroscopic Investigation Into The Setting And Mechanical Properties Of Titanium Containing Glass Polyalkenoate Cements, A. W. Wren, A. Kidari, N. M. Cummins, Mark R. Towler
Chemical and Biochemical Engineering Faculty Research & Creative Works
Titanium (Ti) implants are extensively used in a number of biomedical and dental applications. This work introduces Ti into the glass phase of a zinc-based glass polyalkenoate cement (GPC) and investigates changes in handling and mechanical properties considering two molecular weight polyacrylic acids (PAA), E9 and E11. Considering the handling properties, the working time (Tw) increased from 50 sE9, 32 sE11 (BT 101, Ti-free) to 169 sE9, 74 sE11 with TW-Z (highest Ti content), respectively. The setting time (Ts) increased from 76 sE9, 47 sE11 (BT 101) …
The Effect Of Adding Organic Polymers On The Handling Properties, Strengths And Bioactivity Of A Ca-Sr-Zn-Si Glass Polyalkenoate Cement, A. W. Wren, N. M. Cummins, A. Coughlan, Mark R. Towler
The Effect Of Adding Organic Polymers On The Handling Properties, Strengths And Bioactivity Of A Ca-Sr-Zn-Si Glass Polyalkenoate Cement, A. W. Wren, N. M. Cummins, A. Coughlan, Mark R. Towler
Chemical and Biochemical Engineering Faculty Research & Creative Works
This work demonstrates the addition of a number of naturally occurring proteins/polymers to a zinc-based glass polyalkenoate cements (GPCs). Chitin (Chi.), collagen (Col.), cysteine (Cys.) and keratin (Ker.) were added with the intention of improving the bioactivity of this cement. Initial testing involved characterization of the glass with X-ray diffraction (XRD) and differential thermal analysis (DTA) before and after sterilization with γ-irradiation. No significant changes occurred as a result of sterilization. Handling properties of the modified cements were not significantly different from those of the control, BT 101 (Working Tw-36s, and setting time Ts-70 …
Influence Of Morphology And Processing On Xps Characterisation Of Sro-Ca-Zno-Sio2 Glass, F. R. Laffir, A. W. Wren, Mark R. Towler
Influence Of Morphology And Processing On Xps Characterisation Of Sro-Ca-Zno-Sio2 Glass, F. R. Laffir, A. W. Wren, Mark R. Towler
Chemical and Biochemical Engineering Faculty Research & Creative Works
A study was conducted to demonstrate the influence of morphology and processing on X-ray photoelectron spectroscopic (XPS) characterization SrO-Ca-ZnO-SiO2 glass. The glass formulation being investigated was originally synthesized for developing a novel glass polyalkenoate cement (GPC). High resolution photoelectron spectra of Zn 2p, Ca 2p, Sr 3d, Si 2p, O 1s, and C 1s were recorded for the different forms of glass. It was observed that there was preferential enrichment of Zn2+ with an increase in the proportion of NBO for the investigated BT101 glass. The relative atomic concentration of Zn in BT101 glass was high and resulted …
Mechanical Properties Of Hydroxyapatite-Zirconia Compacts Sintered By Two Different Sintering Methods, Declan J. Curran, Thomas J. Fleming, Mark R. Towler, Stuart Hampshire
Mechanical Properties Of Hydroxyapatite-Zirconia Compacts Sintered By Two Different Sintering Methods, Declan J. Curran, Thomas J. Fleming, Mark R. Towler, Stuart Hampshire
Chemical and Biochemical Engineering Faculty Research & Creative Works
Microwave sintering is traditionally employed to reduce the sintering temperature required to densify powder compacts. The effect of microwave heating on hydroxyapatite (HA)-zirconia (ZrO2) green bodies has been investigated in order to understand how microwave energy may affect the physical and mechanical properties of the resultant densified composites. Laboratory synthesised nano-sized HA and a commercial nano-sized ZrO2 powder have been ball milled to create mixtures containing 0-5 wt% ZrO2 loadings. Compacts were microwave sintered at either 700, 1000 or 1200°C with a 1 h hold time. Comparative firings were also performed in a resistive element furnace …
Surface Engineering Of Macrophages With Nanoparticles To Generate A Cell-Nanoparticle Hybrid Vehicle For Hypoxia-Targeted Drug Delivery, Christopher A. Holden, Quan Yuan, W. Andrew Yeudall, Deborah A. Lebman, Hu Yang
Surface Engineering Of Macrophages With Nanoparticles To Generate A Cell-Nanoparticle Hybrid Vehicle For Hypoxia-Targeted Drug Delivery, Christopher A. Holden, Quan Yuan, W. Andrew Yeudall, Deborah A. Lebman, Hu Yang
Chemical and Biochemical Engineering Faculty Research & Creative Works
Tumors frequently contain hypoxic regions that result from a shortage of oxygen due to poorly organized tumor vasculature. Cancer cells in these areas are resistant to radiation- and chemotherapy, limiting the treatment efficacy. Macrophages have inherent hypoxia-targeting ability and hold great advantages for targeted delivery of anticancer therapeutics to cancer cells in hypoxic areas. However, most anticancer drugs cannot be directly loaded into macrophages because of their toxicity. In this work, we designed a novel drug delivery vehicle by hybridizing macrophages with nanoparticles through cell surface modification. Nanoparticles immobilized on the cell surface provide numerous new sites for anticancer drug …
Evaluation Of Two Novel Aluminum-Free, Zinc-Based Glass Polyalkenoate Cements As Alternatives To Pmma Bone Cement For Use In Vertebroplasty And Balloon Kyphoplasty, Gladius Lewis, Mark R. Towler, Daniel Boyd, Matthew J. German, Anthony W. Wren, Owen M. Clarkin, Andrew Yates
Evaluation Of Two Novel Aluminum-Free, Zinc-Based Glass Polyalkenoate Cements As Alternatives To Pmma Bone Cement For Use In Vertebroplasty And Balloon Kyphoplasty, Gladius Lewis, Mark R. Towler, Daniel Boyd, Matthew J. German, Anthony W. Wren, Owen M. Clarkin, Andrew Yates
Chemical and Biochemical Engineering Faculty Research & Creative Works
Vertebroplasty (VP) and balloon kyphoplasty (BKP) are now widely used for treating patients in whom the pain due to vertebral compression fractures is severe and has proved to be refractory to conservative treatment. These procedures involve percutaneous delivery of a bolus of an injectable bone cement either directly to the fractured vertebral body, VB (VP) or to a void created in it by an inflatable bone tamp (BKP). Thus, the cement is a vital component of both procedures. In the vast majority of VPs and BKPs, a poly(methyl methacrylate) (PMMA) bone cement is used. This material has many shortcomings, notably …
Fabrication Of Spherical Cao-Sro-Zno-Sio2 Particles By Sol-Gel Processing, Ill Yong Kim, Mark R. Towler, Anthony Wren, Chikara Ohtsuki
Fabrication Of Spherical Cao-Sro-Zno-Sio2 Particles By Sol-Gel Processing, Ill Yong Kim, Mark R. Towler, Anthony Wren, Chikara Ohtsuki
Chemical and Biochemical Engineering Faculty Research & Creative Works
This study was concerned with the fabrication of ceramic CaO-SrO-ZnO-SiO2 spherical particles, which are novel candidates for the glass phase in glass polyalkenoate cements (GPCs). GPCs made from these glasses have potential as bone cements because, unlike conventional GPCs, they do not contain aluminum ions, which inhibit the calcification of hydroxyapatite in the body. The glass phase of GPCs require a controllable glass morphology and particle size distribution. Sol-gel processing can potentially be used to fabricate homogenous ceramic particles with controlled morphology. However, a thorough study on preparation conditions of spherical CaO-SrO-ZnO-SiO2 particles by sol-gel processing has, to …
Characterisation And Mechanical Testing Of Hydrothermally Treated Ha/Zro2 Composites, D. J. Curran, T. J. Fleming, G. Kawachi, C. Ohtsuki, Mark R. Towler
Characterisation And Mechanical Testing Of Hydrothermally Treated Ha/Zro2 Composites, D. J. Curran, T. J. Fleming, G. Kawachi, C. Ohtsuki, Mark R. Towler
Chemical and Biochemical Engineering Faculty Research & Creative Works
Hydrothermal treatment is traditionally employed to improve the sinterability of powder compacts by reducing porosity and increasing apparent density. The effect of hydrothermal treatment on green powder compacts has been assessed in order to better understand how treatment may affect the sinter ability of the bodies. Laboratory synthesized nano sized hydroxyapatite (HA) and a commercial zirconia (ZrO2) powder have been ball milled together to create composite mixtures containing 0-5 wt% ZrO2 loadings. Disc shaped bodies have been formed using uniaxial and subsequent isostatic pressure. The resultant coherent samples were subjected to hydrothermal treatment at either 120 or …
Analysis Of Γ-Irradiated Synthetic Bone Grafts By ²⁹Si Mas-Nmr Spectroscopy, Calorimetry And Xrd, D. Boyd, S. Murphy, Mark R. Towler, A. W. Wren, S. Hayakawa
Analysis Of Γ-Irradiated Synthetic Bone Grafts By ²⁹Si Mas-Nmr Spectroscopy, Calorimetry And Xrd, D. Boyd, S. Murphy, Mark R. Towler, A. W. Wren, S. Hayakawa
Chemical and Biochemical Engineering Faculty Research & Creative Works
Ca-Sr-Zn-Si glasses have demonstrated excellent biocompatibility both in vitro using the MTT assay with L929 mouse fibroblast cells, and in vivo using healthy and ovariectomized female Wistar rats. However, the biological evaluation of the materials was performed on glass granules that were autoclaved, rather than γ-irradiated; the sterilisation procedure required prior to implantation of these materials in the human body. Given the fact that when a glass is exposed to ionizing radiation changes in its physical properties can take place, it is imperative to determine whether the structure of such glasses will be altered as a result of exposure to …
Simple Agarose-Chitosan Gel Composite System For Enhanced Neuronal Growth In Three Dimensions, Zheng Cao, Ryan J. Gilbert, Wei He
Simple Agarose-Chitosan Gel Composite System For Enhanced Neuronal Growth In Three Dimensions, Zheng Cao, Ryan J. Gilbert, Wei He
Chemical and Biochemical Engineering Faculty Research & Creative Works
A simplified approach to increase neuronal attachment on an agarose hydrogel was proposed by blending agarose with another biocompatible polysaccharide, chitosan. The stiffness of the agarose gel was maintained despite the inclusion of chitosan, as determined by rheological tests. The structure of the blended hydrogels was characterized using light microscopy and scanning electron microscopy. An in vitro cell study revealed that the blends promoted neuron adhesion. The concentration of chitosan in the hydrogel had great influence on the morphology of neurons. An optimum range of chitosan concentration in agarose gel, to enhance neural cell attachment and differentiation, was identified based …
The Effect Of Glass Synthesis Route On Mechanical And Physical Properties Of Resultant Glass Ionomer Cements, A. Wren, O. M. Clarkin, F. R. Laffir, C. Ohtsuki, I. Y. Kim, Mark R. Towler
The Effect Of Glass Synthesis Route On Mechanical And Physical Properties Of Resultant Glass Ionomer Cements, A. Wren, O. M. Clarkin, F. R. Laffir, C. Ohtsuki, I. Y. Kim, Mark R. Towler
Chemical and Biochemical Engineering Faculty Research & Creative Works
Glass ionomer cements (GICs) have potential orthopaedic applications. Solgel processing is reported as having advantages over the traditional melt-quench route for synthesizing the glass phase of GICs, including far lower processing temperatures and higher levels of glass purity and homogeneity. This work investigates a novel glass formulation, BT 101 (0.48 SiO2-0.36 ZnO-0.12 CaO-0.04 SrO) produced by both the melt-quench and the solgel route. The glass phase was characterized by X-ray diffraction (XRD) to determine whether the material was amorphous and differential thermal analysis (DTA) to measure the glass transition temperature (Tg). Particle size analysis (PSA) was …
Comparison Of Failure Mechanisms For Cements Used In Skeletal Luting Applications, O. Clarkin, D. Boyd, Mark R. Towler
Comparison Of Failure Mechanisms For Cements Used In Skeletal Luting Applications, O. Clarkin, D. Boyd, Mark R. Towler
Chemical and Biochemical Engineering Faculty Research & Creative Works
Glass Polyalkenoate Cements (GPCs) based on strontium calcium zinc silicate (Sr-Ca-Zn-SiO2) glasses and low molecular weight poly (acrylic acid) (PAA) have been shown to exhibit suitable compressive strength (65 MPa) and flexural strength (14 MPa) for orthopaedic luting applications. In this study, two such GPC formulations, alongside two commercial cements (Simplex ® P and Hydroset™) were examined. Fracture toughness and tensile bond strength to sintered hydroxyapatite and a biomedical titanium alloy were examined. Fracture toughness of the commercial Poly(methyl methacrylate) cement, Simplex® P, (3.02 MPa m1/2) was superior to that of the novel GPC (0.36 MPa …
Comparison Of An Experimental Bone Cement With A Commercial Control, Hydroset™, O. M. Clarkin, D. Boyd, S. Madigan, Mark R. Towler
Comparison Of An Experimental Bone Cement With A Commercial Control, Hydroset™, O. M. Clarkin, D. Boyd, S. Madigan, Mark R. Towler
Chemical and Biochemical Engineering Faculty Research & Creative Works
Glass polyalkenoate cements based on strontium calcium zinc silicate glasses (Zn-GPCs) and high molecular weight polyacrylic acids (PAA) (MW; 52,000-210,000) have been shown to exhibit mechanical properties and in vitro bioactivity suitable for arthroplasty applications. Unfortunately, these formulations exhibit working times and setting times which are too short for invasive surgical applications such as bone void filling and fracture fixation. In this study, Zn-GPCs were formulated using a low molecular weight PAA (MW; 12,700) and a modifying agent, trisodium citrate dihydrate (TSC), with the aim of improving the rheological properties of Zn-GPCs. These novel formulations were then compared with commercial …
Biofilm Inhibitory Coatings Formulated From Glass Polyalkenoate Cement Chemistry: An Evaluation Of Their Adhesive Nature, A. Coughlan, D. Boyd, Mark R. Towler
Biofilm Inhibitory Coatings Formulated From Glass Polyalkenoate Cement Chemistry: An Evaluation Of Their Adhesive Nature, A. Coughlan, D. Boyd, Mark R. Towler
Chemical and Biochemical Engineering Faculty Research & Creative Works
Researchers evaluated the adhesive nature of the biofilm inhibitory coatings formulated from glass polyalkenoate cement (GPC) chemistry with the aim to establish the novel testing modality by modifying the conventional T-peel tests. Special consideration was given to determine the resistance of a bonded assembly of two adherents having at least one adherent flexible to quantify the bond between tape and a surgical metal substrate bonded by a luting GPC. The delaminated tape surface was examined by scanning electron microscopy (SEM) with an accelerating voltage of 20 K V to determine whether failure of the bond was adhesive of cohesive in …
Antibacterial Properties Of A Tri-Sodium Citrate Modified Glass Polyalkenoate Cement, A. W. Wren, D. Boyd, R. Thornton, J. C. Cooney, Mark R. Towler
Antibacterial Properties Of A Tri-Sodium Citrate Modified Glass Polyalkenoate Cement, A. W. Wren, D. Boyd, R. Thornton, J. C. Cooney, Mark R. Towler
Chemical and Biochemical Engineering Faculty Research & Creative Works
Primary deep infection following joint replacement surgery accounts for 7% of all revisions. Glass polyalkenoate cements (GPCs) have previously been shown to exhibit antibacterial properties. The present study had two objectives. The first was to determine if addition of tri-sodium citrate (TSC) to the powder phase of an Al-free GPC (0.04 SrO-0.12 CaO-0.36 ZnO-0.48 SiO2, by mole fraction) enhanced the resultant cement's antibacterial properties against three strains of bacteria that are commonly found in periprosthetic sites following total joint replacements (TJRs); namely, E. coli, B. fragilis, and S. epidermidis. Four cement sets were prepared, which contained 0 wt% TSC (control), …
Preliminary Investigation Of Novel Bone Graft Substitutes Based On Strontium-Calcium-Zinc-Silicate Glasses, D. Boyd, G. Carroll, Mark R. Towler, C. Freeman, P. Farthing, I. M. Brook
Preliminary Investigation Of Novel Bone Graft Substitutes Based On Strontium-Calcium-Zinc-Silicate Glasses, D. Boyd, G. Carroll, Mark R. Towler, C. Freeman, P. Farthing, I. M. Brook
Chemical and Biochemical Engineering Faculty Research & Creative Works
Bone graft procedures typically require surgeons to harvest bone from a second site on a given patient (Autograft) before repairing a bone defect. However, this results in increased surgical time, excessive blood loss and a significant increase in pain. In this context a synthetic bone graft with excellent histocompatibility, built in antibacterial efficacy and the ability to regenerate healthy tissue in place of diseased tissue would be a significant step forward relative to current state of the art philosophies. We developed a range of calcium-strontium-zinc-silicate glass-based bone grafts and characterized their structure and physical properties, then evaluated their in vitro …