Open Access. Powered by Scholars. Published by Universities.®
Biomedical Engineering and Bioengineering Commons™
Open Access. Powered by Scholars. Published by Universities.®
- Discipline
-
- Biomedical Devices and Instrumentation (79)
- Other Biomedical Engineering and Bioengineering (38)
- Molecular, Cellular, and Tissue Engineering (26)
- Biomechanics and Biotransport (17)
- Biological Engineering (14)
-
- Medicine and Health Sciences (14)
- Mechanical Engineering (13)
- Biomaterials (12)
- Bioimaging and Biomedical Optics (11)
- Systems and Integrative Engineering (10)
- Biomechanical Engineering (8)
- Life Sciences (7)
- Analytical, Diagnostic and Therapeutic Techniques and Equipment (5)
- Electrical and Computer Engineering (5)
- Medical Specialties (5)
- Physiology (5)
- Biomedical (4)
- Cellular and Molecular Physiology (4)
- Electrical and Electronics (4)
- Diseases (3)
- Manufacturing (3)
- Materials Science and Engineering (3)
- Other Mechanical Engineering (3)
- Therapeutics (3)
- Anatomy (2)
- Biology (2)
- Cardiovascular Diseases (2)
- Child Psychology (2)
- Keyword
-
- Arteriogenesis (18)
- Ischemia (12)
- Biomechanics (9)
- Myoblast (7)
- Medical device (5)
-
- Peripheral arterial occlusive disease (5)
- Tissue Engineering (5)
- Tissue engineering (5)
- Baseball (4)
- Biomedical (4)
- Microfluidics (4)
- Motion analysis (4)
- Osteoporosis (4)
- Vasodilation (4)
- Angiogenesis (3)
- Biomaterials (3)
- Biomedical Engineering (3)
- Cell therapy (3)
- Cell transplantation (3)
- Device (3)
- Electrospinning (3)
- Neural-electronics (3)
- PAOD (3)
- Principal component analysis (3)
- Spinotrapezius (3)
- Temperature (3)
- Ankle (2)
- Arterialization (2)
- BVM (2)
- Balance (2)
- Publication Year
- Publication Type
- File Type
Articles 61 - 90 of 278
Full-Text Articles in Biomedical Engineering and Bioengineering
Bone And Cartilage Compression Simulator, Karoline M. Wucherer, Benjamin A. Parmentier, Thomasina E. Hinkle
Bone And Cartilage Compression Simulator, Karoline M. Wucherer, Benjamin A. Parmentier, Thomasina E. Hinkle
Biomedical Engineering
A device was developed that delivers mechanical loads to bone and soft tissue samples under physiological conditions to aid in the research of tissue engineering bone and cartilage. To begin the design process, a Network Diagram and Gantt Chart were produced to create a general timeline for the project to follow. This allowed us to measure our progress and determine what effects (if any) delays could have on our project.
Live Cell Imaging Gas Control, Elsa M. Bean, Brady C. Berg, Abby A. Jens
Live Cell Imaging Gas Control, Elsa M. Bean, Brady C. Berg, Abby A. Jens
Biomedical Engineering
The following document outlines the entire process for designing and manufacturing a Live Cell Imaging Gas Control subsystem in tandem with the Heated Stage subsystem to make a CO2 and temperature-controlled chamber for use with the Olympus IX73P2F Microscope. It highlights the current literature and patents surrounding live cell imaging and touches on the existing live cell imaging setups currently being used by other entities. Following this, it defines the scope of the project, key customer requirements, and engineering specifications to ensure the design meets all the needs of its users. This document includes project planning steps to establish …
Live Cell Imaging Heated Stage, Kerri Byrne, Anna Frauenheim, Simon Park
Live Cell Imaging Heated Stage, Kerri Byrne, Anna Frauenheim, Simon Park
Biomedical Engineering
Live cell imaging is a method used by scientists to obtain a better understanding of tissue and cell functions through the study and imaging of cellular dynamics, however it is often detrimental to cell cultures due to effects of changing environment on dynamic cellular events. In order to combat the effects of a changing environment, our team has designed, manufactured, and tested an incubation chamber that will control the heat and pH environment that these cells are experiencing throughout the imaging process. This project is sponsored by the BMED microscopy core group to be used with the Olympus IX73P2F inverted …
Minivette Integrated Sample Prep Funnel For Cepheid Cartridges, Hanna N. Blumer, Sophia Arias, Camille Porciuncula, Ben Runkle
Minivette Integrated Sample Prep Funnel For Cepheid Cartridges, Hanna N. Blumer, Sophia Arias, Camille Porciuncula, Ben Runkle
Biomedical Engineering
This report covers the redesign of the Sample Prep Funnel for Cepheid’s engineering team. The Sample Prep Funnel, responsible for relaying liquid from the sample collection device to the testing cartridge, experiences fluid loss that causes invalid test results. Our group's task was to redesign this funnel to minimize fluid loss and, overall, increase efficiency and effectiveness.
Pickleball Paddle For Minimizing Elbow/Shoulder Joint Forces, Kaley Sapper, Nick Rodgers, Claire Steines
Pickleball Paddle For Minimizing Elbow/Shoulder Joint Forces, Kaley Sapper, Nick Rodgers, Claire Steines
Biomedical Engineering
The goal of this project was to design a pickleball paddle to prevent overuse injuries. This was accomplished through a design that minimizes joint forces experienced by the player during backhand strokes.
Feverdots, Kameryn Laureano, Heidi Silk, Rita Grigorian
Feverdots, Kameryn Laureano, Heidi Silk, Rita Grigorian
Biomedical Engineering
FeverDots are wearable temperature sensitive stickers that change color from black to pink at 99°F when placed on the temple or forehead. The objective of this project was to develop an efficient manufacturing method for FeverDots, and manufacture a device along with it. To create the FeverDots manufacturing device, the full design process was executed. The team went through a thorough ideation phase before ultimately defining and specifying the scope of the project.
The key customer requirements of this device include that it is lightweight, portable, durable, simple to assemble, easy to use, and able to generate uniform ink and …
Astm Test Fixture For Spinal Screws, Sarah K. Pickering, Matthew W. Rowen, Kaajal N. Khanna, Thomas A. Sunding
Astm Test Fixture For Spinal Screws, Sarah K. Pickering, Matthew W. Rowen, Kaajal N. Khanna, Thomas A. Sunding
Biomedical Engineering
This document is an overview report of the Cal Poly Senior Project ASTM Test Fixture for SeaSpine orthopedic bone screws. The main application of orthopedic screws is to fasten implants directly to the bone structure, enhancing structural integrity. Testing for breaking angle, insertion torque, removal torque, axial pullout strength, and self-tapping force as specified in the ASTM F543 Annexes provides the FDA with vital screw mechanics and ensures manufacturing uniformity. The test system is comprised of custom and off the shelf components allowing for interchangeability, in case of part failure, and a low overall cost. It is mechanically capable of …
Flywheel Fanny Pack Balance Assist, Ella Joy Mahood, Jason Scott Provol, Raymond Ming Tseng
Flywheel Fanny Pack Balance Assist, Ella Joy Mahood, Jason Scott Provol, Raymond Ming Tseng
Biomedical Engineering
The aim of this project is to develop a wearable device that will provide support to a balance impaired individual. The device will be predicated on the principle of gyroscopes. It will include a rapidly spinning flywheel, which will resist any changes to spatial orientation.
Handheld Transvaginal Probe For Pap Smear Exams, Kim Knollenberg, Taeah Truong
Handheld Transvaginal Probe For Pap Smear Exams, Kim Knollenberg, Taeah Truong
Biomedical Engineering
This project aims to discard the use of the speculum in pap smear exams. A pap smear is a procedure that tests for cervical cancer in individuals assigned female at birth (AFAB) by screening cells collected from the cervix. Speculums are utilized in these examinations, as well as other gynecologic examinations and procedures. Due to the stigma and racist and misogynistic history of the speculum, we moved to design a device that removes the need for specula in pap smear exams. This device will aim to decrease the cervical cancer mortality rate and reduce the stigma around pap smear exams.
3-D Positioning System For Trackable Adjustments Of Papillary Muscles, Ryan Michael Winters, Micaela Andrea Bataclan, Christine Do, Giselle Morales
3-D Positioning System For Trackable Adjustments Of Papillary Muscles, Ryan Michael Winters, Micaela Andrea Bataclan, Christine Do, Giselle Morales
Biomedical Engineering
Redacted.
Hand Strength And Dexterity Enhancer, Julia Ann Denison, Autumn B. Rexford, Melissa A. Kurani, Christina K. Fong
Hand Strength And Dexterity Enhancer, Julia Ann Denison, Autumn B. Rexford, Melissa A. Kurani, Christina K. Fong
Biomedical Engineering
Good Grips created the hand strength and dexterity enhancer project to meet the challenge presented by Bill Phelps. He has Inclusion Body Myositis (IBM), an inflammatory muscle disease characterized by progressive muscle weakness and atrophy. Bill has limited strength in both hands and lost the ability to bend his fingers, making it difficult to grip anything. He needed a device that would help with everyday tasks such as writing, lifting, and holding various objects.
Our team consists of four engineering students attending Cal Poly, San Luis Obispo. We researched, designed, manufactured, and tested a device that would fulfill the problem …
Automatic Tourniquet For Military Emergencies, Arshia Nazerani Houshmand, Marina Felt, Blake Juett
Automatic Tourniquet For Military Emergencies, Arshia Nazerani Houshmand, Marina Felt, Blake Juett
Biomedical Engineering
This document contains the progress and development of an automated tourniquet that would be intended for use within the United States military. The project was student-led and sponsored. Coordination and confirmation of our device was provided by Dr. John F. Kragh, who is part of the U.S. Army Institute of Surgical Research. The document will outline the research conducted on tourniquets, specification development of the tourniquet, morphology process, and final design production of the automatic tourniquet.
The Impact Of Myoblast Transplantation On Collateral Capillary Arteriogenesis And Macrophage Phenotype, Christine Hue Do
The Impact Of Myoblast Transplantation On Collateral Capillary Arteriogenesis And Macrophage Phenotype, Christine Hue Do
Biomedical Engineering
Gangrene, pain, loss of limb function, amputation, and death are only few of the grievous consequences associated with peripheral arterial disease (PAD), a vascular disease caused by an obstruction that narrows the blood vessels. Since some patients have collateral vessels that can re-route blood to its downstream destination, much focus has been spotlighted upon discovering the mechanism of this process, termed arteriogenesis, as well as cell therapies to increase arterial diameter of collateral vessels. Since some patients do not have native pre-existing collateral vessels, another method to re-route blood is through arterialized collateral capillaries (ACC), which is the conversion of …
Calibrated Tensioner For Total Knee Arthroplasty Gap Balancer, Lauren Henigman, Jaypreet Dhanota, Corey Catuara
Calibrated Tensioner For Total Knee Arthroplasty Gap Balancer, Lauren Henigman, Jaypreet Dhanota, Corey Catuara
Biomedical Engineering
The purpose of this project was to design a device that interfaces with the previously created gap balancer to simultaneously measure the gap between the femur and tibia and measure the tension in the ligaments of the knee. First, we met with Dr. Delagrammaticas to outline the key customer requirements: we wanted the device to be precise, sterilizable, reliable, and compatible with the gap balancer. Based on the customer requirements, we outlined the specifications that would drive our design and testing, which included precision, ease of use, size, and material properties. The design process began by using a morphology to …
Stair Wagon To Heaven, Maria Cristina Solis Andrade, Nick Ryan Dion, Alexander Pham
Stair Wagon To Heaven, Maria Cristina Solis Andrade, Nick Ryan Dion, Alexander Pham
Biomedical Engineering
Our design process began with developing a list of questions for our sponsor based on the problem statement we were provided. We took these questions to interview our sponsor. From this interview, we derived a series of customer requirements, which were then used to develop our more specific engineering specifications (Table 8.1). We used these engineering specifications to develop a design morphology. Each of our group mates used the concepts from our design morphology to develop their own full concept sketches. We used Pugh charts to compare the different aspects of each design. The designs were compared based off their …
Knee Angles After Crosstalk Correction With Principal Component Analysis In Gait And Cycling, Jordan Skaro, Scott J. Hazelwood, Stephen M. Klisch
Knee Angles After Crosstalk Correction With Principal Component Analysis In Gait And Cycling, Jordan Skaro, Scott J. Hazelwood, Stephen M. Klisch
Biomedical Engineering
Principal component analysis (PCA) has been used as a post-hoc method for reducing knee crosstalk errors during gait analysis. PCA minimizes correlations between flexion–extension (FE), abduction–adduction (AA), and internal–external rotation (IE) angles. However, previous studies have not considered PCA for exercises involving knee flexion angles that are greater than those typically experienced during gait. Thus, the goal of this study was to investigate using PCA to correct for crosstalk during one exercise (i.e., cycling) that involves relatively high flexion angles. Fifteen participants were tested in gait and cycling using a motion analysis system. Uncorrected FE, AA and IE angles were …
The Tierni Resistance Training System, Michael J. Hansen, Abigail M. Youngblood, Gabriel M. Johnson
The Tierni Resistance Training System, Michael J. Hansen, Abigail M. Youngblood, Gabriel M. Johnson
Biomedical Engineering
The purpose of the Tierni Resistance Training System project was to design and construct functional workout apparel that has built-in resistance. For this product, the key customer requirements we set out to address were most importantly material comfort and functionality, followed by stylishness, lack of latex, safety for injured and uninjured users, and washer safety. To meet these customer requirements, we started by researching current resistance training technology, and used the findings as a springboard for our own design development. After initial brainstorming, engineering specifications were generated based on the customer requirements. These specifications revolved around the thermal insulation, pressure, …
Electro-Muscle-To-Muscle Transfer, Hailey Quinn Casino, Jake Keola Javier, Samuel Joseph Borda, Charlotte Amalie Anderson
Electro-Muscle-To-Muscle Transfer, Hailey Quinn Casino, Jake Keola Javier, Samuel Joseph Borda, Charlotte Amalie Anderson
Biomedical Engineering
The Electro Muscle to Muscle Transfer (EMMT) system will entail designing, manufacturing, and providing a wearable device that stimulates paralyzed muscles in the hand by sampling and amplifying muscles from the forearm. With further development, the system may be capable of using different muscle inputs other than the forearm muscles along with different stimulated muscle outputs other than the hand. The system functions as a rehabilitative device for spinal cord injuries, irreparable nerve loss and/or damage, and improper neuromuscular function. It is not for total treatment nor for curing of the disabilities listed above but to alleviate the side effects …
Gyroscopic Human Balance Device, Randy Lam Hau, Spencer Ross, Yael Farkash
Gyroscopic Human Balance Device, Randy Lam Hau, Spencer Ross, Yael Farkash
Biomedical Engineering
This project’s sponsor, Charlie Guitierrez, has decades of experience building assistive walking devices for the wheelchair bound population. During his work, he noticed that many of his clients retained some ability to balance themselves and so theorized that they would be able to walk independently if given some form of assistance. This assistance could potentially be in the form of a wearable gyroscope. Gyroscopes are commonly used to stabilize objects subjected to instability, such as bicycles, motorcycles, and ships. Thus, a wearable gyroscope would assist its user in maintaining overall stability by imparting reactive torques and forces if the user …
Hypoxic Incubation Chamber, Makenzie Jones, Andrea Skattenborg, Henry Elsner
Hypoxic Incubation Chamber, Makenzie Jones, Andrea Skattenborg, Henry Elsner
Biomedical Engineering
In developing a model to test anti-tumor drugs, Dr. Christopher Heylman’s lab requires the ability to culture cells in a hypoxic environment. The purpose of this project was to make this possible. Funding for this project comes from the Biomedical Engineering Department, the Hannah-Forbes Fund, and Dr. Heylman’s lab. The chamber must be able to reach a user-defined oxygen concentration and hold that concentration for 48 hours while creating an environment conducive to cell culture. Importantly, the chamber must also be sterilizable and cleanable for repeated use. While several products exist to create hypoxic environments for cell culture, they are …
Alternative Epinephrine Auto-Injector, Joshua Wong, Uriel Nieves-Cruz, Tara Howard
Alternative Epinephrine Auto-Injector, Joshua Wong, Uriel Nieves-Cruz, Tara Howard
Biomedical Engineering
Project: Alternative Epinephrine Injector started as a solution for Bianca Aleman’s little brother however the scope has evolved to include the many millions of individuals across the world who struggle with a life-threatening allergen. The stakeholders of this project are Cal Poly and Dr. Michael D. Whitt. Our goals are the following:
● Develop a foolproof method of injection that consistently delivers a dosage of epinephrine
● Be equal or less than the current size of an EpiPen (6 in)
● Be easy to transport or store when not-in-use
● Create an isolated environment where the epinephrine will not be …
Virtual Stethoscope - Otoscope, Ermen J. Elenes-Cazares, Ceasar A. Hurtado, Thomas M. Margolle
Virtual Stethoscope - Otoscope, Ermen J. Elenes-Cazares, Ceasar A. Hurtado, Thomas M. Margolle
Biomedical Engineering
The purpose of this report was to develop a working prototype for a virtual stethoscope and otoscope. Sponsored by Courtney Farr, the virtual diagnostic care system – HouseCalls Mobile digital stethoscope/otoscope is meant for use by medical professionals and non – medical professionals for preliminary medical exams while physically not in a medical setting. The HouseCalls Mobile device is to characterize key biometric parameters such as breathing patterns, heart irregularities, and visual clinical evaluation of the inner ear. This device is intended for pediatric use.
Tmtt Chimera Valve Attachment Process, Paulina Nguyen, Devin Debouk, Tamar Kazazian, Noah Thompson
Tmtt Chimera Valve Attachment Process, Paulina Nguyen, Devin Debouk, Tamar Kazazian, Noah Thompson
Biomedical Engineering
No abstract provided.
Non-Invasive Peripheral Venous And Arterial Line Air Detector For Embolization Prevention, Alexandria Kwong, Kevin Shu, Dylan Meinster
Non-Invasive Peripheral Venous And Arterial Line Air Detector For Embolization Prevention, Alexandria Kwong, Kevin Shu, Dylan Meinster
Biomedical Engineering
The scope of this project includes designing a non-invasive bubble detector for peripheral venous and arterial lines. For minimally invasive cardiac procedures, arterial and venous access is necessary for these procedures as is constant flow through the tubing to prevent clotting and to administer drugs. Air bubbles are common in these lines and can be consequential if enough air is introduced into the human system. Air embolisms are the most common and relevant issues during these procedures. The goal of this device is to create an attachable detector for air bubbles in saline that can also terminate flow and alert …
Concussion Detection Device, Jenna C. Sussex, Mark B. Edin, Bianca X. Aleman
Concussion Detection Device, Jenna C. Sussex, Mark B. Edin, Bianca X. Aleman
Biomedical Engineering
No abstract provided.
D.I.Y. Clean Hood, Samuel G. Porter, Ryan E. Shimogaki, Ryan S. Staples
D.I.Y. Clean Hood, Samuel G. Porter, Ryan E. Shimogaki, Ryan S. Staples
Biomedical Engineering
The DIY Clean Hood is a low-cost, sterile, and accessible scientific workspace intended for installation in the BioElectroFluidics Lab of California Polytechnic State University’s (San Luis Obispo) Biomedical Engineering Department (BMED), under the sponsorship of Dr. Benjamin Hawkins, PhD. As normal Clean Hood, Biosafety Cabinets, and the like are generally too expensive for a university, a competitive solution to an expensive problem can assist research students and professors alike continue their own work with an inexpensive yet effective environment.
Specific design elements that the customer requirements entailed for the project include a low-particle-count air filtration system, positive pressure air flow …
Septal Closure Device, Olivia N. Welch, Hillal H. Jarrar, Kai Harrison
Septal Closure Device, Olivia N. Welch, Hillal H. Jarrar, Kai Harrison
Biomedical Engineering
The septal closure device was designed to seal defects in the atrial septum. To fully seal an atrial defect, the device was designed to consist of two circular seals to cover the defect in both the right and left atria, attached with a central rod. The materials were chosen for compressibility (for ease of insertion), biocompatibility, and tissue ingrowth. A CAD model was drafted in SolidWorks. Key customer requirements include ease of implantation (specifications: adjustable sizing and clear directions for use), physician controlled (specifications: short implantation time and compatibility with current catheter/scope techniques), and a long lifetime (specifications: materials that …
Opendrop Elisa: Surface Development For Digital Microfluidic Elisa Testing, Michaela Q. Mead, Madeline G. Jackson, Jacob G. Taylor
Opendrop Elisa: Surface Development For Digital Microfluidic Elisa Testing, Michaela Q. Mead, Madeline G. Jackson, Jacob G. Taylor
Biomedical Engineering
This project aimed to develop a process to create a hydrophobic coating with capture antibodies attached. This process was developed in an attempt to create a digital microfluidic platform upon which an enzyme-linked immunosorbent assay (ELISA) could be run, indicated for clinicians and educators in low-resource settings. Four requirements dictated the course of the design process: 1) the contact angle with water of the hydrophobic layer must be greater than 90º, 2) the colorimetric response of a positive ELISA result on our platform must be at least 85% of that run on polystyrene with the same result, 3) the platform …
Inverse Dynamics Analysis Of Youth Pitching Arm Kinetics Using Body Composition Imaging, Jay A. Sterner, Scott K. Reaves, Arnel L. Aguinaldo, Scott Hazelwood, Stephen M. Klisch
Inverse Dynamics Analysis Of Youth Pitching Arm Kinetics Using Body Composition Imaging, Jay A. Sterner, Scott K. Reaves, Arnel L. Aguinaldo, Scott Hazelwood, Stephen M. Klisch
Biomedical Engineering
This study’s objectives were to: (1) assess whether dual energy X-ray absorptiometry (DXA)-mass inverse dynamics (ID) alters predictions of youth pitching arm kinetics and (2) investigate correlations between kinetics and body composition. Eighteen 10- to 11-year-olds pitched 10 fastballs. DXA scans were conducted to obtain participant-specific upper arm, forearm, and hand masses. Pitching arm segment masses and kinetics calculated with scaled and DXA masses were compared with paired t-tests and correlations were investigated with linear regression. Hand (p < 0.001) and upper arm (p < 0.001) DXA masses were greater, while forearm (p < 0.001) DXA masses were lesser, than their scaled masses. Shoulder compressive force (p < 0.001), internal rotation torque (p < 0.001), and horizontal adduction torque (p = 0.002) increased when using DXA masses. Shoulder compressive force correlated with body mass (p < 0.001) and body mass index (BMI; p = 0.002) and elbow varus torque correlated with body mass (p < 0.05). The main conclusions were that (1) using participant-specific mass ratios leads to different predictions of injury-related pitching arm kinetics and, thus, may improve our understanding of injury risk factors; and (2) pitching arm kinetics were correlated with body composition measures and a relatively high total body mass and/or BMI may increase shoulder and/or elbow injury risk.
Diy Incubator, Aryan Zia, Grace Spurlock, Garrett Janney
Diy Incubator, Aryan Zia, Grace Spurlock, Garrett Janney
Biomedical Engineering
This project report provides detailed information on designing and building a DIY Incubator. The device is indicated for growing and maintaining BSL-1 mammalian or bacterial cell culture with a temperature control in the range of 25-45°C ± 1°C. The device is made fully programmable via an Arduino, and is structurally designed to fit two T75 cell culture flasks at a time. The device is able to return to a specified temperature set point within 10 minutes and maintains 5% CO2 partial pressure conditions. The incubator has a small physical footprint, with an overall dimension of 22in x 16in x 15.5in …