Open Access. Powered by Scholars. Published by Universities.®

Biomedical Engineering and Bioengineering Commons™

Open Access. Powered by Scholars. Published by Universities.®

Purdue University

Discipline
Keyword
Publication Year
Publication
Publication Type

Articles 271 - 300 of 417

Full-Text Articles in Biomedical Engineering and Bioengineering

In Vivo Method For Labeling And Tracking Cells In The Mammalian Limb Bud, James T. Mccarthy, Andrew Schilb, Sarah Calve Oct 2013

In Vivo Method For Labeling And Tracking Cells In The Mammalian Limb Bud, James T. Mccarthy, Andrew Schilb, Sarah Calve

The Summer Undergraduate Research Fellowship (SURF) Symposium

The extracellular matrix (ECM) is composed of many different proteins excreted by cells and is believed to play a very important role in development as well as regeneration and wound healing. In this research, a method to determine the ECM’s effect on the migration of muscle progenitor cells into the mammalian limb bud was investigated. It has traditionally been difficult to obtain in vivo images of the limb bud, due to the difficulty of maintaining embryos in culture and limitations of imaging techniques. In this study, we have worked on optimizing the culture conditions to allow growth of mouse embryos …


Visualization Of Complex Flow Patterns In Angiotensin Ii-Induced Dissecting Murine Abdominal Aortic Aneurysms With High Frequency Ultrasound, Hilary D. Schroeder, Alexa A. Yrineo, Amy E. Bogucki, Craig J. Goergen Oct 2013

Visualization Of Complex Flow Patterns In Angiotensin Ii-Induced Dissecting Murine Abdominal Aortic Aneurysms With High Frequency Ultrasound, Hilary D. Schroeder, Alexa A. Yrineo, Amy E. Bogucki, Craig J. Goergen

The Summer Undergraduate Research Fellowship (SURF) Symposium

Abdominal aortic aneurysm (AAA) rupture is a common cause of mortality in the United States. Current treatments are only employed once the risk of rupture outweighs the risks associated with surgery. Murine models have been developed to characterize AAA pathogenesis in the hope that new treatments will be developed. For this study, angiotensin II (AngII) was infused subcutaneously into apolipoprotein E-deficient (ApoE-/-) mice using an osmotic mini-pump over 28 days. ApoE-/- mice (16-week-old, 3 females, 2 males) were imaged using a VisualSonics Vevo 2100 high frequency ultrasound before pump implantation and 3, 7, 14, 21, and 27 …


Image Skeletal Muscle Progenitors In Situ To Investigate How The Ecm Composition Regulates Musculoskeletal Assembly, Andrew L. Schilb, Sarah Calve Oct 2013

Image Skeletal Muscle Progenitors In Situ To Investigate How The Ecm Composition Regulates Musculoskeletal Assembly, Andrew L. Schilb, Sarah Calve

The Summer Undergraduate Research Fellowship (SURF) Symposium

Regenerative medicine has difficulty with the human body’s inability to functionally repair tissues lost as a result of disease or serious accident. Through tissue engineering, there has been development of various scaffolding with the purpose of enhancing skeletal muscle regrowth and functionality. The scaffolds are typically constructed from artificial polymers or decellularized extracellular matrix (ECM) that mimics adult tissue. These standardized scaffolds are hindered though by the host since tissue engineers have not taken into account of how the composition musculoskeletal ECM during tissue repair is dramatically different than that of a homeostatic adult. Now green fluorescent protein positive (GFP+) …


The Effects Of Exogenous Extracellular Matrix And Substrate Stiffness On Mouse Tendon Cells In Vitro, Caleb J. Mcdaniel, Sarah Calve Oct 2013

The Effects Of Exogenous Extracellular Matrix And Substrate Stiffness On Mouse Tendon Cells In Vitro, Caleb J. Mcdaniel, Sarah Calve

The Summer Undergraduate Research Fellowship (SURF) Symposium

To improve the treatment of musculoskeletal injuries, a better understanding of the transitional environment in which progenitor cells form mature musculoskeletal constructs is necessary. This need arises because injury repair requires restructuring of tissue, similar to the initial tissue construction that occurs during embryonic development by progenitor cells. Differences in both the biochemical and mechanical environments between a transitional and a differentiated state are known to take place, but how these differences affect cell behavior had not yet been characterized in mammalian tendon cells. In order to investigate this, we have determined the effects of exogenous extracellular matrix and the …


Wireless Myoelectric Sensor Minimization And Packaging, Ásbjörg Einarsdóttir, Pedro Irazoqui Dr. Oct 2013

Wireless Myoelectric Sensor Minimization And Packaging, Ásbjörg Einarsdóttir, Pedro Irazoqui Dr.

The Summer Undergraduate Research Fellowship (SURF) Symposium

Many people suffer from amputation, which affects their lives severely by disabling them from doing chores in their daily life as well as chores related to work and leisure. For the last years, prosthetics’ development has been fast and the devices that are being used now are a miracle compared to what has been used before. But still, the battle is not over yet. Although scientists have techniques and devices to use nerve residues from the amputated limb to control the prosthetic, smaller devices that can detect the signals from those nerves better need to be developed. In this research …


Toward An Optogenetic Autonomous Nerve Control (Oanc) System, Malika S. Datta, Matthew Ward, Steven Lee, Kevin Seburn, Pedro Irazoqui Oct 2013

Toward An Optogenetic Autonomous Nerve Control (Oanc) System, Malika S. Datta, Matthew Ward, Steven Lee, Kevin Seburn, Pedro Irazoqui

The Summer Undergraduate Research Fellowship (SURF) Symposium

Optogenetics is a developing field in neuroscience, where nerves are stimulated through optical instead of electrical signals, allowing for a more selective action of nerve populations [Aravanis et al, 2007]. In the context of electrical stimulation, the autonomous nerve control (ANC) system has been used successfully, first to map the response of different nerve fibers to create a Nerve Activation Profile, and then to use this profile in recruiting specific nerve fibers in a controlled way [MP Ward et al, unpublished manuscript in preparation]. The objective of the present project is to apply the ANC system to optical stimulation thus …


Inkjet Printing Of Polarized Yeast Cells, Xiuyuan Yang, Kari Clase Oct 2013

Inkjet Printing Of Polarized Yeast Cells, Xiuyuan Yang, Kari Clase

The Summer Undergraduate Research Fellowship (SURF) Symposium

The motivation is to applying engineering knowledge to develop 3D bio-printing in inkjet printer (first stage--monolayer). To achieve the goal, there are three problems to solve. First, we have to figure out regulation of growth of target cells; inability to regulate the location and pattern of growing cells make us even unable to build 3D printer in the direct way. Second problem is how to protect of yeast cells from high temperature and viscous force when printing. The third issue is how to modify the inkjet printer especially the feeding system in order to implement printing on other materials rather …


Adhesive Elastomeric Proteins, Haefa Mansour, Julie Liu Oct 2013

Adhesive Elastomeric Proteins, Haefa Mansour, Julie Liu

The Summer Undergraduate Research Fellowship (SURF) Symposium

Sutures and staples commonly used to close surgical wounds tend to be much stiffer than the surrounding tissue, often resulting in external tissue damage. Surgical adhesives provide a promising alternative to these sutures and staples. Ideal surgical adhesives are biocompatible, able to set well and remain sticky in moist conditions, possess strong adhesive and cohesive properties, and exhibit mechanical properties that mimic those of the surrounding tissue. Unfortunately, the adhesives available today are unable to satisfactorily meet all of these criteria. We are utilizing protein engineering techniques to design, create, and test a new surgical adhesive that combines the adhesive …


A Quantitative Analysis Of A Paper-Based, Laser-Defined, Oxygen-Generating Platform For Chronic Wounds, Tiffany L. Huang, Babak Ziaie Oct 2013

A Quantitative Analysis Of A Paper-Based, Laser-Defined, Oxygen-Generating Platform For Chronic Wounds, Tiffany L. Huang, Babak Ziaie

The Summer Undergraduate Research Fellowship (SURF) Symposium

Chronic wounds affect 6.5 million patients a year while consuming US$25 billion in health care costs (Sen 2009 Wound Repair Regen.). Despite advances in wound management therapies, modern treatment for chronic wounds still requires continual professional attention and expensive equipment, posing serious practical and financial burdens for the regular patient. To provide an alternative solution, we are developing a low-cost smart bandage platform that integrates actuators and sensors to monitor and treat chronic wounds. One component of the integrated platform is an oxygen-generating module. It is a polydimethylsiloxane (PDMS) based microfluidic device fabricated on a parchment paper substrate that …


Development Of Non-Invasive In Vivo Ultrasound Imaging Techniques For Elastase-Induced Experimental Abdominal Aortic Aneurysms, Alexa A. Yrineo, Elizabeth A. Nunamaker, Hilary D. Schroeder, Amy E. Bogucki, Craig J. Goergen Oct 2013

Development Of Non-Invasive In Vivo Ultrasound Imaging Techniques For Elastase-Induced Experimental Abdominal Aortic Aneurysms, Alexa A. Yrineo, Elizabeth A. Nunamaker, Hilary D. Schroeder, Amy E. Bogucki, Craig J. Goergen

The Summer Undergraduate Research Fellowship (SURF) Symposium

Abdominal aortic aneurysms (AAAs) are pathological dilations of the aorta which are associated with significant morbidity and mortality. The underlying mechanisms that cause this inflammatory disease are not fully understood and thus, are currently under investigation. In the hopes of preventing disease progression, rodent models that mimic the human condition have been developed to provide insight into the pathogenesis of AAAs. In this study, porcine pancreatic elastase (0.44 U; Sigma-Aldrich) was infused into the infrarenal aortas of male, Sprague Dawley rats to induce aneurysms. To perform the surgery, temporary ligatures were placed around proximal and distal sections of the abdominal …


Direct Quantitative Analysis Of Biomarkers Using Mass Spectrometry, Morgan N. Mcluckey, Zheng Ouyang Oct 2013

Direct Quantitative Analysis Of Biomarkers Using Mass Spectrometry, Morgan N. Mcluckey, Zheng Ouyang

The Summer Undergraduate Research Fellowship (SURF) Symposium

Point-of-care (POC) diagnostics describes a step in the medical treatment process where drugs can be monitored in a patient’s body on-site and in a timely fashion. Mass spectrometry (MS) can provide a quick, efficient, and highly accurate method of analysis of patient biofluids and tissues. Developing methods to bring this diagnostic mechanism to hospitals and clinics has the potential to improve patient care through, for example, personalized medicine. Our goal was to develop a way to effectively introduce internal standard (IS), a necessary chemical for the analytical process, to low-volume biofluid samples. Additionally, the effective direct quantitation of biomarkers with …


Iron-Magnesium Alloy Bioabsorbable Blood Stent, Kaitlyn Jarry, L Stanciu Oct 2013

Iron-Magnesium Alloy Bioabsorbable Blood Stent, Kaitlyn Jarry, L Stanciu

The Summer Undergraduate Research Fellowship (SURF) Symposium

Bioabsorbable materials are fairly new and proper alloys for implantation in the body have not yet been established. There are a few polymers that have showed promise, but they do not provide the proper mechanical support that metal does. These materials would be used to create devices such as blood stents and orthopedic screws. Investigation into the properties of different alloys can help to establish a material that can be used for implanted devices that are only needed for a limited amount of time. In order to investigate these alloys many different experiments will to be run to test the …


Characterization Of The Saturation Level Of Nucleosome Arrays And Plasmids By Mnase Digestion, Wenjie Liu, Nathan Nurse, Chongli Yuan Oct 2013

Characterization Of The Saturation Level Of Nucleosome Arrays And Plasmids By Mnase Digestion, Wenjie Liu, Nathan Nurse, Chongli Yuan

The Summer Undergraduate Research Fellowship (SURF) Symposium

Studying processes involving DNA such as DNA replication and transcription is best done in the context of chromatin because the structure of DNA influences the efficiency of such processes. Chromatin structure is derived from DNA wrapping around histone octamers with the histone octamer density termed saturation level. For in vitro studies on DNA replication and transcription, it is important to maintain a constant saturation level so that saturation level can be removed as a variable. Our goal is to characterize the saturation level of plasmids using the rate of MNase digestion. MNase digestions were first performed on reconstituted nucleosome arrays …


We Still Need A Real-Time Hemodynamic Monitor For Cpr, Charles F. Babbs Jun 2013

We Still Need A Real-Time Hemodynamic Monitor For Cpr, Charles F. Babbs

Weldon School of Biomedical Engineering Faculty Publications

No abstract provided.


The Case For Interposed Abdominal Compression Cpr In Hospital Settings, Charles F. Babbs Jan 2013

The Case For Interposed Abdominal Compression Cpr In Hospital Settings, Charles F. Babbs

Weldon School of Biomedical Engineering Faculty Publications

Interposed abdominal compression (IAC)-CPR includes all steps of standard external CPR with the addition of manual mid-abdominal compressions in counterpoint to the rhythm of chest compressions. IAC-CPR can increase blood flow during CPR about two fold compared to standard CPR without IAC, as shown by multiple studies in computer and animal models. The technique increases the rate return of spontaneous circulation (ROSC) for in-hospital resuscitations from roughly 25% to 50%. Improved survival to discharge is demonstrated in two in-hospital trials. IAC as an adjunct technique is quickly taught and is less complex than most other basic life support maneuvers. A …


Differential Mitochondrial Toxicity Screening And Multi- Parametric Data Analysis, Maria V. Tsiper, Jennifer Sturgis, Larisa V. Avramova, Shilpa Parakh, Raymond Fatig, Ana Juan-García, Nianyu Li, Bartek Rajwa, Padma Narayanan, C. W. Wualls Jr., Joseph P. Robinson, Vincent J. Davisson Oct 2012

Differential Mitochondrial Toxicity Screening And Multi- Parametric Data Analysis, Maria V. Tsiper, Jennifer Sturgis, Larisa V. Avramova, Shilpa Parakh, Raymond Fatig, Ana Juan-García, Nianyu Li, Bartek Rajwa, Padma Narayanan, C. W. Wualls Jr., Joseph P. Robinson, Vincent J. Davisson

Weldon School of Biomedical Engineering Faculty Publications

Early evaluation of new drug entities for their potential to cause mitochondrial dysfunction is becoming an important task for drug development. Multi-parametric high-content screening (mp-HCS) of mitochondrial toxicity holds promise as a lead in-vitro strategy for drug testing and safety evaluations. In this study, we have developed a mp-HCS and multi-parametric data analysis scheme for assessing cell responses to induced mitochondrial perturbation. The mp-HCS measurements are shown to be robust enough to allow for quantitative comparison of biological systems with different metabolic pathways simulated by alteration of growth media. Substitution of medium glucose for galactose sensitized cells to drug action …


Predicting Success Or Failure Of Immunotherapy For Cancer: Insights From A Clinically Applicable Mathematical Model, Charles F. Babbs Jan 2012

Predicting Success Or Failure Of Immunotherapy For Cancer: Insights From A Clinically Applicable Mathematical Model, Charles F. Babbs

Weldon School of Biomedical Engineering Faculty Publications

The objective of this study was to create a clinically applicable mathematical model of immunotherapy for cancer and use it to explore differences between successful and unsuccessful treatment scenarios. The simplified predator-prey model includes four lumped parameters: tumor growth rate, g; immune cell killing efficiency, k; immune cell signaling factor, λ; and immune cell half-life decay, μ. The predator-prey equations as functions of time, t, for normalized tumor cell numbers, y, (the prey) and immunocyte numbers, x, (the predators) are: dy/dt = gy – kx and dx/dt = λxy – μx. A parameter estimation procedure that capitalizes on available clinical …


Optimizing Electrode Placement For Hemodynamic Benefit In Cardiac Resynchronization Therapy, Charles F. Babbs Jan 2012

Optimizing Electrode Placement For Hemodynamic Benefit In Cardiac Resynchronization Therapy, Charles F. Babbs

Weldon School of Biomedical Engineering Faculty Publications

Background: Research is needed to explore the relative benefits of alternative electrode placements in biventricular and left ventricular pacing for heart failure with left bundle branch block (LBBB). Methods: A fast computational model of the left ventricle, running on an ordinary laptop computer, was created to simulate the spread of electrical activation over the myocardial surface, together with the resulting electrocardiogram, segmental wall motion, stroke volume, and ejection fraction in the presence of varying degrees of mitral regurgitation. Arbitrary zones of scar and blocked electrical conduction could be modeled. Results: Simulations showed there are both sweet spots and poor spots …


Control System For Mass Spectrometer, Jian Xu May 2011

Control System For Mass Spectrometer, Jian Xu

Purdue Polytechnic Masters Theses

Mass spectrometry (MS) is a very popular analytical methodology that measures the mass of ions using a mass spectrometer. It is widely used for determining masses of chemicals, the elemental composition of a sample and molecule structure. The process of mass spectrometry normally consists of ionizing chemical compounds to ions and measuring their ratios of mass to charge for analysis.

MS instruments consist of three modules: Ionization, Analysis and detection. A LabVIEW system was developed to control the three modules of a mass spectrometer, giving the required signals in a right sequence. Experiments can be carried out by using the …


Quantitative Reappraisal Of The Helmholtz-Guyton Resonance Theory Of Frequency Tuning In The Cochlea, Charles F. Babbs Apr 2011

Quantitative Reappraisal Of The Helmholtz-Guyton Resonance Theory Of Frequency Tuning In The Cochlea, Charles F. Babbs

Weldon School of Biomedical Engineering Faculty Publications

To explore the fundamental biomechanics of sound frequency transduction in the cochlea, a two-dimensional analytical model of the basilar membrane was constructed from first principles. Quantitative analysis showed that axial forces along the membrane are negligible, condensing the problem to a set of ordered one-dimensional models in the radial dimension, for which all parameters can be specified from experimental data. Solutions of the radial models for asymmetrical boundary conditions produce realistic deformation patterns. The resulting second-order differential equations, based on the original concepts of Helmholtz and Guyton, and including viscoelastic restoring forces, predict a frequency map and amplitudes of deflections …


Theory Of ‘Selectivity’ Of Label-Free Nanobiosensors – A Geometro-Physical Perspective, Pradeep R. Nair, Muhammad A. Alam Jan 2010

Theory Of ‘Selectivity’ Of Label-Free Nanobiosensors – A Geometro-Physical Perspective, Pradeep R. Nair, Muhammad A. Alam

Birck and NCN Publications

Modern label-free biosensors are generally far more sensitive and require orders of magnitude less incubation time compared to their classical counterparts. However, a more important characteristic regarding the viability of this technology for applications in Genomics/Proteomics is defined by the ‘Selectivity’, i.e., the ability to concurrently and uniquely detect multiple target biomolecules in the presence of interfering species. Currently, there is no theory of Selectivity that allows optimization of competing factors and there are few experiments to probe this problem systematically. In this article, we use the elementary considerations of surface exclusion, diffusion limited transport, and void distribution function to …


Anterior-Posterior Impedance Cardiography: A New Approach To Accurate, Non-Invasive Monitoring Of Cardiac Function, Charles F. Babbs Jan 2010

Anterior-Posterior Impedance Cardiography: A New Approach To Accurate, Non-Invasive Monitoring Of Cardiac Function, Charles F. Babbs

Weldon School of Biomedical Engineering Faculty Publications

The conventional impedance cardiogram is a record of pulsatile changes in the electrical impedance of the chest with each heartbeat. The signal seems intuitively related to cardiac stroke volume. However doubts persist about the validity of stroke volume measurements based on electrical impedance. This paper presents a new electrical axis for impedance cardiography that is perpendicular to the conventional head-to-foot axis in an anterior-posterior direction. Dual chest and back electrodes are concentric, permitting tetrapolar technique. A relatively simple analytical model is developed, and this model is validated in a three-dimensional finite element model of current flow through the human chest. …


Methods For Calculating Coronary Perfusion Pressure During Cpr, Michael P. Otlewski, Leslie A. Geddes, Michael Pargett, Charles F. Babbs Sep 2009

Methods For Calculating Coronary Perfusion Pressure During Cpr, Michael P. Otlewski, Leslie A. Geddes, Michael Pargett, Charles F. Babbs

Weldon School of Biomedical Engineering Faculty Publications

Coronary perfusion pressure (CPP) is a major indicator of the effectiveness of cardiopulmonary resuscitation in human and animal research studies; however methods for calculating CPP differ among research groups. Here we compare the 6 published methods for calculating CPP using the same data set of aortic (Ao) and right atrial (RA) blood pressures. CPP was computed using each of the 6 calculation methods in an anesthetized pig model, instrumented with catheters with Cobe pressure transducers. Aortic and right atrial pressures were recorded continuously during electrically induced ventricular fibrillation and standard CPR. CPP calculated from the same raw data set by …


Gold Nanorod-Mediated Photothermolysis Induces Apoptosis Of Macrophages Via Damage Of Mitochondria, Ling Tong, Ji-Xin Cheng Apr 2009

Gold Nanorod-Mediated Photothermolysis Induces Apoptosis Of Macrophages Via Damage Of Mitochondria, Ling Tong, Ji-Xin Cheng

Other Nanotechnology Publications

Aims: Induction of apoptosis or necrosis in activated macrophages by gold nanorod-mediated photothermolysis is demonstrated and the mechanisms underlying the processes are investigated. Materials & methods: Gold nanorods were functionalized with cysteine-octaarginine peptides (R8-NRs). Uptake of R8-NRs by activated macrophages was monitored by two-photon luminescence imaging. The laser irradiation conditions were controlled to induce apoptosis or necrosis to R8-NR-internalized macrophages. Mitochondrial damage and reactive oxygen species overproduction during photothermolysis was investigated by confocal fluorescence microscopy and transmission-electron microscopy. Results: Activated macrophages efficiently uptake R8-NRs both in vitro and in live animals. Laser irradiation of internalized nanorods with controlled power density …


Gold Nanorods As Contrast Agents For Biological Imaging: Optical Properties, Surface Conjugation And Photothermal Effects, Ling Tong, Qingshan Wei, Alexander Wei, Ji-Xin Cheng Jan 2009

Gold Nanorods As Contrast Agents For Biological Imaging: Optical Properties, Surface Conjugation And Photothermal Effects, Ling Tong, Qingshan Wei, Alexander Wei, Ji-Xin Cheng

Other Nanotechnology Publications

Gold nanorods (NRs) have plasmon-resonant absorption and scattering in the near-infrared (NIR) region, making them attractive probes for in vitro and in vivo imaging. In the cellular environment, NRs can provide scattering contrast for darkfield microscopy, or emit a strong two-photon luminescence due to plasmon-enhanced two-photon absorption. NRs have also been employed in biomedical imaging modalities such as optical coherence tomography or photoacoustic tomography. Careful control over surface chemistry enhances the capacity of NRs as biological imaging agents by enabling cell-specific targeting, and by increasing their dispersion stability and circulation lifetimes. NRs can also efficiently convert optical energy into heat, …


Quantitative Prediction Of Body Surface Potentials From Myocardial Action Potentials Using A Summed Dipole Model, Charles F. Babbs Jan 2009

Quantitative Prediction Of Body Surface Potentials From Myocardial Action Potentials Using A Summed Dipole Model, Charles F. Babbs

Weldon School of Biomedical Engineering Faculty Publications

This paper demonstrates quantitatively, using streamlined mathematics, how the transmembrane ionic currents in individual cardiac muscle cells act to produce the body surface potentials of the electrocardiogram (ECG). From fundamental principles of electrostatics, anatomy, and physiology, one can characterize the strength of apparent dipoles along a wavefront of depolarization in a local volume of myocardium. Net transmembrane flow of ionic current in actively depolarizing or repolarizing tissue induces extracellular current flow, which sets up a field of electrical potential that resembles that of a dipole. The local dipole strength depends upon the tissue cross section, the tissue resistivity, the resting …


Neonatal Cpr: Room At The Top—A Mathematical Study Of Optimal Chest Compression Frequency Versus Body Size, Charles F. Babbs, Andrew Meyer, Vinay Nadkarni Jan 2009

Neonatal Cpr: Room At The Top—A Mathematical Study Of Optimal Chest Compression Frequency Versus Body Size, Charles F. Babbs, Andrew Meyer, Vinay Nadkarni

Weldon School of Biomedical Engineering Faculty Publications

Objective: To explore in detail the expected magnitude of systemic perfusion pressure during standard CPR as a function of compression frequency for different sized people from neonate to adult. Method: A 7-compartment mathematical model of the human cardiopulmonary system—upgraded to include inertance of blood columns in the aorta and vena cavae—was exercised with parameters scaled to reflect changes in body weight from 1 to 70 kg. Results: Maximal systemic perfusion pressure occurs at chest compression rates near 60, 120, 180, and 250 per minute for subjects weighing 70, 10, 3, and 1 kg, respectively. Such maxima are predicted by analytical …


Release Of Hydrophobic Molecules From Polymer Micelles Into Cell Membranes Revealed By Forster Resonance Energy Transfer Imaging, Hongtao Chen, Sungwon Kim, Shuyi Wang, Kinam Park, Ji-Xin Cheng May 2008

Release Of Hydrophobic Molecules From Polymer Micelles Into Cell Membranes Revealed By Forster Resonance Energy Transfer Imaging, Hongtao Chen, Sungwon Kim, Shuyi Wang, Kinam Park, Ji-Xin Cheng

Other Nanotechnology Publications

it is generally assumed that polymeric micelles, upon administration into the blood stream, carry drug molecules until they are taken up into cells followed by intracellular release. The current work revisits this conventional wisdom. The study using dual-labeled micelles containing fluorescently labeled copolymers and hydrophobic fluorescent probes entrapped in the polymeric micelle core showed that cellular uptake of hydrophobic probes was much faster than that of labeled copolymers. This result implies that the hydrophobic probes in the core are released from micelles in the extracellular space. Forster resonance energy transfer (FRET) imaging and spectroscopy were used to monitor this process …


A New Paradigm For Human Resuscitation Research Using Intelligent Devices, Charles F. Babbs, Andre E. Kemeny, Weilun Quan, Gary Freeman Jan 2008

A New Paradigm For Human Resuscitation Research Using Intelligent Devices, Charles F. Babbs, Andre E. Kemeny, Weilun Quan, Gary Freeman

Weldon School of Biomedical Engineering Faculty Publications

Objectives: To develop new methods for studying correlations between the performance and outcome of resuscitation efforts in real-world clinical settings using data recorded by automatic devices such as automatic external defibrillators (AEDs), and to explore effects of shock timing and chest compression depth in the field. Methods: In 695 records of AED use in the pre-hospital setting, continuous compression data were recorded using AEDs capable of measuring sternal motion during compressions, together with timing of delivered shocks and the electrocardiogram. In patients who received at least one shock, putative return of spontaneous circulation (P-ROSC) was defined as a regular, narrow …


Gold Nanorods Mediate Tumor Cell Death By Compromising Membrane Integrity, Ling Tong, Yan Zhao, Terry B. Huff, Matthew N. Hansen, Alexander Wei, Ji-Xin Cheng Oct 2007

Gold Nanorods Mediate Tumor Cell Death By Compromising Membrane Integrity, Ling Tong, Yan Zhao, Terry B. Huff, Matthew N. Hansen, Alexander Wei, Ji-Xin Cheng

Other Nanotechnology Publications

Folate-conjugated gold nanorods targeted to tumor cell surfaces produced severe membrane damage upon near-infrared irradiation. Photoinduced injury to the plasma membrane resulted in a rapid increase in intracellular calcium (shown in green) with subsequent disruption of the actin network, featured prominently by the formation of membrane blebs.