Full-Text Articles in Biomedical Engineering and Bioengineering

A 3d Biomimetic Scaffold Using Electrospinning For Tissue Engineering Applications, Samerender Nagam Hanumantharao Jan 2017

A 3d Biomimetic Scaffold Using Electrospinning For Tissue Engineering Applications, Samerender Nagam Hanumantharao

Dissertations, Master's Theses and Master's Reports

Electrospinning holds great promise for designing functional 3D biomimetic scaffolds for tissue engineering applications. The technique allows for the reproducible fabrication of 3D scaffolds with control over the porosity and thickness. In this work, a novel method for the synthesis of a 3D electroactive scaffold using electrospinning from polycaprolactone (PCL), Polyvinylidene Fluoride (PVDF) and Polyaniline (PANI) is reported. Additional scaffolds involving different morphologies of PCL, PCL-PVDF and PCL-PANI-PVDF were also fabricated and evaluated. The scaffolds were characterized using electron microscopy to visualize the morphologies. Infrared spectroscopy was used to confirm the presence of polymers and their respective phases in the …


Computational Ultrasound Elastography: A Feasibility Study, Yu Wang Jan 2017

Computational Ultrasound Elastography: A Feasibility Study, Yu Wang

Dissertations, Master's Theses and Master's Reports

Ultrasound Elastography (UE) is an emerging set of imaging modalities used to assess the biomechanical properties of soft tissues. UE has been applied to numerous clinical applications. Particularly, results from clinical trials of UE in breast lesion differentiation and staging liver fibrosis indicated that there was a lack of confidence in UE measurements or image interpretation. Confidence on UE measurements interpretation is critically important for improving the clinical utility of UE. The primary objective of my thesis is to develop a computational simulation platform based on open-source software packages including Field II, VTK, FEBio and Tetgen. The proposed virtual simulation …


Surface Enabled Lab-On-A-Chip (Loc) Device For Protein Detection And Separation, Zhichao Wang Jan 2017

Surface Enabled Lab-On-A-Chip (Loc) Device For Protein Detection And Separation, Zhichao Wang

Dissertations, Master's Theses and Master's Reports

Sensitive and selective chemical/biological detection/analysis for proteins is essential for applications such as disease diagnosis, species phenotype identification, product quality control, and sample examination. Lab-on-a-chip (LOC) device provides advantages of fast analysis, reduced amount of sample requirements, and low cost, to magnificently facilitate protein detection research. Isoelectric focusing (IEF) is a strong and reliable electrophoretic technique capable of discerning proteins from complex mixtures based on the isoelectric point (pI) differences. It has experienced plenty of fruitful developments during previous decades which has given it the capability of performing with highly robust and reproducible analysis. This progress has made IEF devices …


Stem Cell And Tissue Engineering Research, Feng Zhao Dec 2016

Stem Cell And Tissue Engineering Research, Feng Zhao

TechTalks

My research focuses on stem cell and tissue engineering. By combining stem cell biology and engineering tools, the Zhao Lab seeks strategies to biofabricate completely biological tissues to regenerate or repair damaged tissues or organs. The function of engineered tissues is being strengthened by recapitulating the in vivo environment of natural tissues. The underlying mechanism is being explored through investigating the interaction of cells with environmental factors such as topographical cues, biophysical forces, and oxygen tensions. We also prompt stem cell research at Michigan Tech to meet the progress and advance of the outside scientific society. Training opportunities are consistently …


Point-Of-Care Microfluidic Device For Blood Typing, Hector Moncada-Hernandez Nov 2016

Point-Of-Care Microfluidic Device For Blood Typing, Hector Moncada-Hernandez

TechTalks

There has been increasing efforts to translate laboratory blood tests analysis into portable, reliable, and cheap miniaturized devices. Electrokinetic-based microfluidic devices provide a new approach to blood tests with a simple infrastructure for the manipulation of cells. Previous studies show red blood cells’ (RBC) dielectrophoretic response changes based on the different ABO-Rh antigens present in the cells membrane. In this research, an alternate-current electric signal with a frequency sweep (0.1 – 1 MHz) is applied through an array of electrodes to generate non-uniform electric fields and induce dielectrophoretic forces on RBC from all eight blood types. The RBC’s response to …


Recent Approaches In Designing Bioadhesive Materials Inspired By Mussel Adhesive Protein, Pegah Kord Forooshani, Bruce P. Lee Oct 2016

Recent Approaches In Designing Bioadhesive Materials Inspired By Mussel Adhesive Protein, Pegah Kord Forooshani, Bruce P. Lee

Department of Biomedical Engineering Publications

Marine mussels secret protein-based adhesives, which enable them to anchor to various surfaces in a saline, intertidal zone. Mussel foot proteins (Mfps) contain a large abundance of a unique, catecholic amino acid, Dopa, in their protein sequences. Catechol offers robust and durable adhe-sion to various substrate surfaces and contributes to the curing of the adhesive plaques. In this article, we review the unique features and the key functionalities of Mfps, catechol chemistry, and strategies for preparing catechol-functionalized poly- mers. Specifically, we reviewed recent findings on the contributions of various features of Mfps on interfacial binding, which include coacervate formation, surface …


Direct Measurement Of Actual Levels Of Nitric Oxide (No) In Cell Culture Conditions Using Soluble No Donors, Weilue He, Megan C. Frost Oct 2016

Direct Measurement Of Actual Levels Of Nitric Oxide (No) In Cell Culture Conditions Using Soluble No Donors, Weilue He, Megan C. Frost

Michigan Tech Publications, Part 1

Applying soluble nitric oxide (NO) donors is the most widely used method to expose cells of interest to exogenous NO. Because of the complex equilibria that exist between components in culture media, the donor compound and NO itself, it is very challenging to predict the dose and duration of NO cells actually experience. To determine the actual level of NO experienced by cells exposed to soluble NO donors, we developed the CellNO Trap, a device that allows continuous, real-time monitoring of the level of NO adherent cells produce and/or experience in culture without the need to alter cell culturing procedures. …


Cellno Trap: Novel Device For Quantitative, Real-Time, Direct Measurement Of Nitric Oxide From Cultured Raw 267.4 Macrophages, Weilue He, Megan C. Frost Aug 2016

Cellno Trap: Novel Device For Quantitative, Real-Time, Direct Measurement Of Nitric Oxide From Cultured Raw 267.4 Macrophages, Weilue He, Megan C. Frost

Michigan Tech Publications, Part 1

Nitric oxide (NO), is arguably one of the most important small signaling molecules in biological systems. It regulates various biological responses in both physiological and pathological conditions, often time producing seemingly contradictory results. The details of the effects of NO are highly dependent on the level of NO that cells experience and the temporal aspect of when and how long cells are exposed to NO. Herein, we present a novel measurement system (CellNO trap) that allows real-time NO measurement via chemiluminescence detection from general adhesive cultured cells using standard cell culture media and reagents that does not perturb the cells …


Spring 2016 Biomedical Engineering Newsletter, Department Of Biomedical Engineering, Michigan Technological University Apr 2016

Spring 2016 Biomedical Engineering Newsletter, Department Of Biomedical Engineering, Michigan Technological University

Department of Biomedical Engineering Newsletters

Table of Contents

  • Focus on Cardiovascular Research
  • BMES Rising Star Feng Zhao
  • Magnetoelastic: Sensing more with less
  • Portage Health/Michigan Tech Partnership
  • Remembering Dr. Michael Neuman


Use Of Lidar In The Design Of Grassed Waterways: Case Study In Agricultural Management In Oklahoma, Annette Sparks Jan 2016

Use Of Lidar In The Design Of Grassed Waterways: Case Study In Agricultural Management In Oklahoma, Annette Sparks

Dissertations, Master's Theses and Master's Reports

Before the advent of Light Detection and Ranging (LiDAR) technology, farm-level infrastructure for sustainable agriculture was designed using topographic maps. LiDAR is a remote sensing method whereby reflected laser pulses are measured to generate high-resolution 3D images of the terrain. This report compares these two methods in the design of grassed waterways for flood drainage and evaluates how the quantitative difference between the two methods can affect the overall hydrologic design. The benefits of LiDAR are expected to be higher accuracy and precision in design, as well as greater reproducibility or consistency, regardless of the designer. To carry out this …


Enhancing Osseointegration Of Orthopaedic Implants With Titania Nanotube Surfaces, Erin A. Baker Jan 2016

Enhancing Osseointegration Of Orthopaedic Implants With Titania Nanotube Surfaces, Erin A. Baker

Dissertations, Master's Theses and Master's Reports

Introduction: As joint arthroplasty surgical procedures increase annually, the development of new strategies, including novel materials and surface modifications, to attain solid bone-implant fixation are needed to increase implant terms of service. In this study, we evaluate two morphologies of titania nanotubes in both in vitro and in vivo experiments to quantify osseointegrative potential and material-level biocompatibility.

Materials and Methods: Samples were prepared via an electrochemical etching process. Two different titania nanotube (TiNT) morphologies were produced, Aligned and Trabecular. For the in vitro experiment, Sprague Dawley (SD) rat marrow-derived bone marrow cells (BMC) were seeded on samples. Alkaline phosphatase (ALP) …


Wireless Implantable Magnetoelastic Sensors And Actuators For Biomedical Applications, Andrew Derouin Jan 2016

Wireless Implantable Magnetoelastic Sensors And Actuators For Biomedical Applications, Andrew Derouin

Dissertations, Master's Theses and Master's Reports

Magnetoelastic sensors represent a low-cost wireless and battery-less method for monitoring parameters in embedded or implanted applications; however, some limitations still exist preventing their commercial implementation. Presented in this work are a variety of studies that are aimed at improving the feasibility of magnetoelastic materials for sensing and actuating applications. Magnetoelastic resonant sensors of non-standard geometries were investigated to determine if geometry could play a role on the sensitivity of the sensor response to mass loading. It was shown that a significant increase in sensitivity could be achieved by using triangular sensors rather than standard rectangular strips. A method for …


Design And Development Of Optical Elastography Setup, Abhinav Madhavachandran Jan 2016

Design And Development Of Optical Elastography Setup, Abhinav Madhavachandran

Dissertations, Master's Theses and Master's Reports

The mechanical properties of the skin are an indication of its physiological condition. The properties can serve as potential information for dermatologists for diagnosis and qualitative assessment. Elastography is a medical imaging modality developed to extract the elastic properties of a tissue by application of an external force. Optical elastography is a technique of elastography which uses laser speckle tracking to study the elastic properties of several soft tissue including skin.

This work is aimed at developing an optical elastography setup that can study the elastic properties of skin. The setup includes an imaging system and a force-application system controlled …


Inhibition Of Bacterial Growth And Prevention Of Bacterial Adhesion With Localized Nitric Oxide Delivery, Julia Osborne Jan 2016

Inhibition Of Bacterial Growth And Prevention Of Bacterial Adhesion With Localized Nitric Oxide Delivery, Julia Osborne

Dissertations, Master's Theses and Master's Reports

Bacterial infections continue to be a problem at the site of an indwelling medical device, and over the years, various bacterial strains have become more resistant to current antibiotic treatments. Bacterial infection at an indwelling medical device can be dangerous and affect the performance of the medical device which can ultimately lead to the failure of the device due to bacterial resistance to treatment.

Nitric Oxide (NO) has been shown to possess antibacterial properties to prevent and inhibit bacterial growth. NO releasing coatings on indwelling medical devices could provide a reduction in bacterial infections that occur at the device site …


Effects Of Scattering And Absorption On Laser Speckle Contrast Imaging, Kosar Khaksari Jan 2016

Effects Of Scattering And Absorption On Laser Speckle Contrast Imaging, Kosar Khaksari

Dissertations, Master's Theses and Master's Reports

Laser Speckle Contrast Imaging (LSCI) is a real-time, non-invasive method in used to investigate blood flow and perfusion in biological tissues with high temporal and spatial resolution. A reduction in speckle contrast due to particle motion is the primary contrast mechanism in LSCI. Motion results in speckle fluctuations in time and reduces the contrast over a given camera integration period. There are a variety of parameters that effect contrast besides motion. The optical properties of the scattering medium are one of the parameters effecting LSCI values. Changes in blood hematocrit levels manifest as changes in optical properties. In this work, …


The Application Of Biomedical Engineering Techniques To The Diagnosis And Management Of Tropical Diseases: A Review, Fatimah Ibrahim, Tzer Hwai Gilbert Thio, Tarig Faisal, Michael Neuman Mar 2015

The Application Of Biomedical Engineering Techniques To The Diagnosis And Management Of Tropical Diseases: A Review, Fatimah Ibrahim, Tzer Hwai Gilbert Thio, Tarig Faisal, Michael Neuman

Michigan Tech Publications, Part 1

This paper reviews a number of biomedical engineering approaches to help aid in the detection and treatment of tropical diseases such as dengue, malaria, cholera, schistosomiasis, lymphatic filariasis, ebola, leprosy, leishmaniasis, and American trypanosomiasis (Chagas). Many different forms of non-invasive approaches such as ultrasound, echocardiography and electrocardiography, bioelectrical impedance, optical detection, simplified and rapid serological tests such as lab-on-chip and micro-/nano-fluidic platforms and medical support systems such as artificial intelligence clinical support systems are discussed. The paper also reviewed the novel clinical diagnosis and management systems using artificial intelligence and bioelectrical impedance techniques for dengue clinical applications.


Mechanical Impedance Of Ankle As A Function Of Electromyography Signals Of Lower Leg Muscles Using Artificial Neural Network, Chen Jia Jan 2015

Mechanical Impedance Of Ankle As A Function Of Electromyography Signals Of Lower Leg Muscles Using Artificial Neural Network, Chen Jia

Dissertations, Master's Theses and Master's Reports - Open

This paper reports on the feasibility of developing a model to describe the nonlinear relationship between the mechanical impedance of the human ankle within a specified range of frequency and the root mean square (RMS) value of the Electromyography (EMG) signals of the muscles of human ankle using Artificial Neural Network (ANN). A lower extremity rehabilitation robot — Anklebot was used to apply pseudo-random mechanical perturbations to the ankle and measure the angular displacement of the ankle to estimate the data of ankle mechanical impedance. Meanwhile, the surface EMG signals from the selected muscles were monitored and recorded using a …


Gelatin Microgel Incorporated Poly (Ethylene Glycol) Bioadhesive With Enhanced Adhesive Property And Bioactivity, Yuting Li Jan 2015

Gelatin Microgel Incorporated Poly (Ethylene Glycol) Bioadhesive With Enhanced Adhesive Property And Bioactivity, Yuting Li

Dissertations, Master's Theses and Master's Reports - Open

In this study, chemically crosslinked gelatin microgels were incorporated into dopamine-modified poly (ethylene glycol) (PEGDM) adhesive to form composite bioadhesive with simultaneously improved adhesive property and bioactivity. Gelatin microgel, with an average diameter of 53.6±14.2μm, was prepared with water in oil emulsification method and chemically crosslinked with
1-ethyl-3-[3-dimethylaminopropyl]carbodiimide hydrochloride (EDC) and N-hydroxysuccinimide (NHS). Gelatin microgels were incorporated into PEGDM adhesive precursor solution at 1.5wt%, 3.75wt% and 7.5wt%. The cure time of adhesive reduced from 54 seconds to 37 seconds with increasing gelatin microgel content. Additionally, the incorporation of the gelatin microgel also increased the crosslinking density of the adhesive network …


Development Of A Cell Morphological Analysis Tool To Evaluate The Ultrasound Vibrational Effects On Cell Adhesion, Joseph M. Smith Jan 2015

Development Of A Cell Morphological Analysis Tool To Evaluate The Ultrasound Vibrational Effects On Cell Adhesion, Joseph M. Smith

Dissertations, Master's Theses and Master's Reports - Open

Fibroblast encapsulation is a stage of the wound healing process in which the implanted device is separated from the biological environment due to the formation of fibrotic tissue. Uncontrolled adhesion of fibroblasts, called fibrosis, has the ability to inhibit an implanted device’s functionality over its lifetime. Over time, fibroblasts have been shown to cause loosening and failure of bone-anchor implants which could include the possibility of harming the patient. The encapsulating process could also hinder the sensitivity of implanted biosensors operating in the body for continuous monitoring. Unfortunately, the antifouling surfaces which are commonly used on implanted devices to control …


The Influence Of Passive Ankle Joint Power On Balance Recovery, Stephanie E. Hamilton Jan 2015

The Influence Of Passive Ankle Joint Power On Balance Recovery, Stephanie E. Hamilton

Dissertations, Master's Theses and Master's Reports - Open

Over one–third of Americans over the age of 65 fall each year, costing more than $19 billion in health care costs in 2000. Many adults 65+ who have not experienced a fall still fear falling, and fear can decrease quality of life and increase the likelihood of falls. Several factors such as muscle strength, power, stiffness and tendon properties change in the human body with age affecting balance, which has been tagged as a fall risk predictor. Additionally, balance recovery strategies also differ between young and older adults, with young adults primarily utilizing their ankle joint and older adults utilizing …


Fibrin Gel As An Injectable Biodegradable Scaffold And Cell Carrier For Tissue Engineering, Yuting Li, Hao Meng, Yuan Liu, Bruce P. Lee Jan 2015

Fibrin Gel As An Injectable Biodegradable Scaffold And Cell Carrier For Tissue Engineering, Yuting Li, Hao Meng, Yuan Liu, Bruce P. Lee

Department of Biomedical Engineering Publications

Due to the increasing needs for organ transplantation and a universal shortage of donated tissues, tissue engineering emerges as a useful approach to engineer functional tissues. Although different synthetic materials have been used to fabricate tissue engineering scaffolds, they have many limitations such as the biocompatibility concerns, the inability to support cell attachment, and undesirable degradation rate. Fibrin gel, a biopolymeric material, provides numerous advantages over synthetic materials in functioning as a tissue engineering scaffold and a cell carrier. Fibrin gel exhibits excellent biocompatibility, promotes cell attachment, and can degrade in a controllable manner. Additionally, fibrin gel mimics the natural …


Ph Responsive, Adhesive Hydrogels Based On Reversible Catechol - Boronic Acid Complexation, Ameya Ravindra Narkar Jan 2015

Ph Responsive, Adhesive Hydrogels Based On Reversible Catechol - Boronic Acid Complexation, Ameya Ravindra Narkar

Dissertations, Master's Theses and Master's Reports - Open

Smart hydrogel adhesives with tunable properties consist of adhesive moieties in the polymer network that respond to external stimuli like pH, temperature, etc. Responsiveness of smart adhesives to pH, in particular, is important because of the simple actuation mechanism and the ability to achieve facile bonding and debonding upon command. Covalently crosslinked hydrogel adhesives were prepared by employing an N-HEAA (hydroxyethyl acrylamide) backbone embedded with dopamine methacrylamide (DMA), a marine mussel inspired adhesive protein and 3-acrylamido phenylboronic acid (AAPBA), to determine the effect of pH on the interfacial binding properties of the hydrogel adhesive with a borosilicate glass substrate. Swelling …


Biocorrosion Rate And Mechanism Of Metallic Magnesium In Model Arterial Environments, Patrick Bowen Jan 2015

Biocorrosion Rate And Mechanism Of Metallic Magnesium In Model Arterial Environments, Patrick Bowen

Dissertations, Master's Theses and Master's Reports

A new paradigm in biomedical engineering calls for biologically active implants that are absorbed by the body over time. One popular application for this concept is in the engineering of endovascular stents that are delivered concurrently with balloon angioplasty. These devices enable the injured vessels to remain patent during healing, but are not needed for more than a few months after the procedure. Early studies of iron- and magnesium-based stents have concluded that magnesium is a potentially suitable base material for such a device; alloys can achieve acceptable mechanical properties and do not seem to harm the artery during degradation. …


Systematic Study Of The Biological Effects Of Nitric Oxide (No) Using Innovative No Measurement And Delivery Systems, Weilue He Jan 2015

Systematic Study Of The Biological Effects Of Nitric Oxide (No) Using Innovative No Measurement And Delivery Systems, Weilue He

Dissertations, Master's Theses and Master's Reports

Nitric oxide (NO) is recognized as the most important small signaling molecule in the human body. An imbalance of NO is closely associated with many serious diseases such as neurological disorders, cardiovascular diseases, chronic inflammations and cancers. Herein two chemiluminescence-based devices (a real-time NO measurement device and a controllable NO delivery device) were developed to facilitate the NO quantitative study and obtain information for NO related drug design.

The first device used for real-time measuring NO(g) flux from living cells was developed and validated. The principle was to use a two-chamber design, with a cell culture chamber and a gaseous …


Development Of High Capacity Hyperbranched Nitric Oxide Donors For Controlling Subcutaneous Inflammation, Sean Hopkins Jan 2015

Development Of High Capacity Hyperbranched Nitric Oxide Donors For Controlling Subcutaneous Inflammation, Sean Hopkins

Dissertations, Master's Theses and Master's Reports

Implanted medical devices undergo complications the longer they remain in contact with tissue or blood. This rejection of foreign materials by our body is one of the largest reasons innovations in biomedical sensors and implanted technology are being held back. One means to hold off this unwanted response is through the utilization of nitric oxide (NO) releasing materials. Two unique NO releasing polymeric materials were synthesized and characterized before being implanted subcutaneously. Both NO releasing materials described used S-nitrosothiol (RSNO) chemistry as the main mechanism for NO release. The first material described covalently links an RSNO to the backbone of …


Engineering Approaches For Suppressing Deleterious Host Responses To Medical Implants, Connor Mccarthy Jan 2015

Engineering Approaches For Suppressing Deleterious Host Responses To Medical Implants, Connor Mccarthy

Dissertations, Master's Theses and Master's Reports

Small diameter (< 6 mm) vascular grafts suffer from serious deleterious effects not encountered with their larger diameter relatives, leading to premature graft failure through restenosis. Platelet activation, inflammation, and smooth muscle cell proliferation are leading contributors to thrombosis and neointimal hyperplasia, both contributors to the progression of restenosis. It may be possible to suppress negative biological responses to vascular implants through the modification of surface properties and incorporation of drug release into blood contacting materials. In this work, bioengineering approaches are presented to improve the biocompatibility of small diameter vascular grafts.

We demonstrate a novel engineering approach for incorporating natural, decollagenized elastin matrices into PEU 1074A reinforced vascular grafts through spray-coating and electrospinning processes in a manner that retains elastin’s excellent blood contacting properties. A vascular construct with excellent mechanical and surgical handling properties demonstrating the suppression of neointimal hyperplasia is presented after 21 days in vivo.

Nitric oxide (NO) has been investigated over the past several decades due to its platelet, inflammation, and smooth muscle cell suppressing effects; and if appropriately delivered, could positively mediate the contributors to restenosis. Here, we characterize a novel macrocyclic NO …


Summer 2014 Biomedical Engineering Newsletter, Department Of Biomedical Engineering, Michigan Technological University Apr 2014

Summer 2014 Biomedical Engineering Newsletter, Department Of Biomedical Engineering, Michigan Technological University

Department of Biomedical Engineering Newsletters

Table of Contents

  • New IEEE, AIMBE and SPIE fellows
  • Arteries on aisle 9
  • Implants with sensors that shake off infection
  • Mitch Kirby wins Whitaker International Fellowship
  • Skin patch warns when it’s time to get out of the sun


Application Of Sub-Micrometer Vibrations To Mitigate Bacterial Adhesion, Will R. Paces, Hal Holmes, Eli Vlaisavljevich, Katherine L. Snyder, Ee Lim Tan, Rupak Rajachar, Keat Ghee Ong Mar 2014

Application Of Sub-Micrometer Vibrations To Mitigate Bacterial Adhesion, Will R. Paces, Hal Holmes, Eli Vlaisavljevich, Katherine L. Snyder, Ee Lim Tan, Rupak Rajachar, Keat Ghee Ong

Michigan Tech Publications, Part 1

As a prominent concern regarding implantable devices, eliminating the threat of opportunistic bacterial infection represents a significant benefit to both patient health and device function. Current treatment options focus on chemical approaches to negate bacterial adhesion, however, these methods are in some ways limited. The scope of this study was to assess the efficacy of a novel means of modulating bacterial adhesion through the application of vibrations using magnetoelastic materials. Magnetoelastic materials possess unique magnetostrictive property that can convert a magnetic field stimulus into a mechanical deformation. In vitro experiments demonstrated that vibrational loads generated by the magnetoelastic materials significantly …


Utilizing Dielectrophoresis To Determine The Physiological Differences Of Eukaryotic Cells, Tayloria Nicole Gail Adams Jan 2014

Utilizing Dielectrophoresis To Determine The Physiological Differences Of Eukaryotic Cells, Tayloria Nicole Gail Adams

Dissertations, Master's Theses and Master's Reports - Open

Type 1 diabetes affects over 108,000 children, and this number is steadily increasing. Current insulin therapies help manage the disease but are not a cure. Over a child’s lifetime they can develop kidney disease, blindness, cardiovascular disease and many other issues due to the complications of type 1 diabetes. This autoimmune disease destroys beta cells located in the pancreas, which are used to regulate glucose levels in the body. Because there is no cure and many children are affected by the disease there is a need for alternative therapeutic options that can lead to a cure.

Human mesenchymal stem cells …


A Backing Device Based On An Embedded Stiffener And Retractable Insertion Tool For Thin-Film Cochlear Arrays, Radheshyam Tewari Jan 2014

A Backing Device Based On An Embedded Stiffener And Retractable Insertion Tool For Thin-Film Cochlear Arrays, Radheshyam Tewari

Dissertations, Master's Theses and Master's Reports - Open

Intracochlear trauma from surgical insertion of bulky electrode arrays and inadequate pitch perception are areas of concern with current hand-assembled commercial cochlear implants. Parylene thin-film arrays with higher electrode densities and lower profiles are a potential solution, but lack rigidity and hence depend on manually fabricated permanently attached polyethylene terephthalate (PET) tubing based bulky backing devices. As a solution, we investigated a new backing device with two sub-systems. The first sub-system is a thin poly(lactic acid) (PLA) stiffener that will be embedded in the parylene array. The second sub-system is an attaching and detaching mechanism, utilizing a poly(N-vinylpyrrolidone)-block-poly(d,l-lactide) (PVP-b-PDLLA) copolymer-based …