Open Access. Powered by Scholars. Published by Universities.®

Biomedical Engineering and Bioengineering Commons™

Open Access. Powered by Scholars. Published by Universities.®

California Polytechnic State University, San Luis Obispo

Discipline
Keyword
Publication Year
Publication
Publication Type
File Type

Articles 571 - 600 of 643

Full-Text Articles in Biomedical Engineering and Bioengineering

Preparation And Characterization Of Electrospun Poly(D, L-Lactide-Co-Glycolide) Scaffolds For Vascular Tissue Engineering And The Advancement Of An In Vitro Blood Vessel Mimic, Tiffany Richelle Pena Jun 2009

Preparation And Characterization Of Electrospun Poly(D, L-Lactide-Co-Glycolide) Scaffolds For Vascular Tissue Engineering And The Advancement Of An In Vitro Blood Vessel Mimic, Tiffany Richelle Pena

Master's Theses

PREPARATION AND CHARACTERIZATION OF ELECTROSPUN POLY(D,L-LACTIDE-CO-GLYCOLIDE) SCAFFFOLDS FOR VASCULAR TISSUE ENGINEERING AND THE ADVANCEMENT OF AN IN VITRO BLOOD VESSEL MIMIC

Tiffany Richelle Peña

Currently, an estimated 1 in every 3 adult Americans are affected by one or more cardiovascular complications. The most common complication is coronary artery disease, specifically atherosclerosis. Outcomes of balloon angioplasty treatments have been significantly improved with the addition of drug eluting stents to the process. Although both bare metal and drug eluting stents have greatly increased the effectiveness of angioplasty and decreased the occurrence of restenosis, several complications still exist. For this reason, the stent …


Design, Fabrication, And Implementation Of A Single-Cell Capture Chamber For A Microfluidic Impedance Sensor, Joshua-Jed Doria Fadriquela Jun 2009

Design, Fabrication, And Implementation Of A Single-Cell Capture Chamber For A Microfluidic Impedance Sensor, Joshua-Jed Doria Fadriquela

Master's Theses

A microfluidic device was created for single-cell capture and analysis using polydimethylsiloxane (PDMS) channels and a glass substrate to develop a microfluidic single-cell impedance sensor for cell diagnostics. The device was fabricated using photolithography to create a master mold which in turn will use soft lithography to create the PDMS components for constant device production. The commercial software, COMSOLTM Multiphysics, was used to quantify the fluid dynamics in shallow micro-channels.

The device will be able to capture a cell and sequester it long enough to enable measurement of the impedance spectra that can characterize cell. The proposed device will be …


Implementation Of Physiologic Flow Conditions In A Blood Vessel Mimic Bioreactor System For The Evaluation Of Intravascular Devices, Marc Cody Dawson May 2009

Implementation Of Physiologic Flow Conditions In A Blood Vessel Mimic Bioreactor System For The Evaluation Of Intravascular Devices, Marc Cody Dawson

Master's Theses

The prevalence and devastating nature of cardiovascular diseases has led to many advancements in the therapies used to treat the millions of patients that suffer as a result of these conditions. As coronary artery disease (CAD) is the most common of these cardiovascular conditions, it is a major focus of research among the medical industry. Although lifestyle changes and drug therapies can treat early CAD, more advanced cases often require more definitive interventions. In conjunction with angioplasty, stenting of an occluded vessel has shown significant success in preventing restenosis. However, as with nearly every therapeutic process in the medical field, …


Theoretical Analysis Of Alendronate And Risedronate Effects On Canine Vertebral Remodeling And Microdamage, Xiang Wang, Antonia M. Erickson, Matthew R. Allen, David B. Burr, R. Bruce Martin, Scott J. Hazelwood May 2009

Theoretical Analysis Of Alendronate And Risedronate Effects On Canine Vertebral Remodeling And Microdamage, Xiang Wang, Antonia M. Erickson, Matthew R. Allen, David B. Burr, R. Bruce Martin, Scott J. Hazelwood

Biomedical Engineering

Bisphosphonates suppress bone remodeling activity, increase bone volume, and significantly reduce fracture risk in individuals with osteoporosis and other metabolic bone diseases. The objectives of the current study were to develop a mathematical model that simulates control and 1 year experimental results following bisphosphonate treatment (alendronate or risedronate) in the canine fourth lumbar vertebral body, validate the model by comparing simulation predictions to 3 year experimental results, and then use the model to predict potential long term effects of bisphosphonates on remodeling and microdamage accumulation. To investigate the effects of bisphosphonates on bone volume and microdamage, a mechanistic biological model …


Development Of An In-Vitro Tissue Engineered Blood Vessel Mimic Using Human Large Vessel Cell Sources, Dimitri E. Delagrammaticas May 2009

Development Of An In-Vitro Tissue Engineered Blood Vessel Mimic Using Human Large Vessel Cell Sources, Dimitri E. Delagrammaticas

Master's Theses

Tissue engineering is an emerging field that offers novel and unmatched potential medical therapies and treatments. While the vast aim of tissue engineering endeavors is to provide clinically implantable constructs, secondary applications have been developed to utilize tissue-engineered constructs for in-vitro evaluation of devices and therapies. Specifically, in-vitro blood vessel mimics (BVM) have been developed to create a bench-top blood vessel model using human cells that can be used to test and evaluate vascular disease treatments and intravascular devices. Previous BVM work has used fat derived human microvascular endothelial cells (EC) sodded on an ePTFE scaffold. To create a more …


A Numerical Approach For Predicting The Impact Of Vascular Architecture On Blood Flow During Ischemic Repair, Stephanie Ann Wood, Shilpi Ghosh, Kevin Jones, Gabriel Gruionu, Trevor R. Cardinals Apr 2009

A Numerical Approach For Predicting The Impact Of Vascular Architecture On Blood Flow During Ischemic Repair, Stephanie Ann Wood, Shilpi Ghosh, Kevin Jones, Gabriel Gruionu, Trevor R. Cardinals

Biomedical Engineering

Abstract of conference presentation.


Functional Vasodilation Following Murine Chronic Hindlimb Ischemia, Matthew David Yocum, Trevor R. Cardinal Apr 2009

Functional Vasodilation Following Murine Chronic Hindlimb Ischemia, Matthew David Yocum, Trevor R. Cardinal

Biomedical Engineering

Abstract of conference presentation.


Fatigue Strength Of Common Tibial Intramedullary Nail Distal Locking Screws, Lanny V. Griffin, Robert M. Harris, Joseph J. Zubak Apr 2009

Fatigue Strength Of Common Tibial Intramedullary Nail Distal Locking Screws, Lanny V. Griffin, Robert M. Harris, Joseph J. Zubak

Biomedical Engineering

Premature failure of either the nail and/or locking screws with unstable fracture patterns may lead to angulation, shortening, malunion, and IM nail migration. Up to thirty percent of all unreamed nail locking screws can break after initial weight bearing is allowed at 8–10 weeks if union has not occurred. The primary problem this presents is hardware removal during revision surgery. The purposes of our study was to evaluate the relative fatigue resistance of distal locking screws and bolts from representative manufacturers of tibial IM nail systems, and develop a relative risk assessment of screws and materials used. Evaluations included quantitative …


Nano-Mechanics Of Cartilage Glycosaminoglycans Using Molecular Dynamics Methods, Kevin Neil Hendrickson Jan 2009

Nano-Mechanics Of Cartilage Glycosaminoglycans Using Molecular Dynamics Methods, Kevin Neil Hendrickson

Master's Theses

Articular Cartilage (AC) is the main load carrying material in synovial joints {Hamerman, 1962} and degeneration of AC can cause pain in the form of arthritis. Current work is centered on the method of replacing damaged cartilage inside the body (in vivo) with tissue engineered outside the body (ex vivo) {Temenoff, 2000}. In order to engineer tissue ex vivo similar to the native tissue in structure and function there must be a comprehensive understanding of the mechanical properties of AC. This work focuses on the study of glycosaminoglycans (GAGs), a molecule known to be primarily responsible for the compressive stiffness …


Abnormal Collateral Artery Vasoactivity Following Chronic Ischemia, Trevor Cardinal, Thomas J. Kesler, Matthew D. Yocum Jan 2009

Abnormal Collateral Artery Vasoactivity Following Chronic Ischemia, Trevor Cardinal, Thomas J. Kesler, Matthew D. Yocum

Biomedical Engineering

No abstract provided.


A Numerical Approach To Determine The Impact Of Network Remodeling On Blood Flow, Trevor Cardinal, Shilpi Ghosh, Stephanie A. Wood, Gabriel Gruionu Jan 2009

A Numerical Approach To Determine The Impact Of Network Remodeling On Blood Flow, Trevor Cardinal, Shilpi Ghosh, Stephanie A. Wood, Gabriel Gruionu

Biomedical Engineering

No abstract provided.


Alterations In Femoral Strain Following Hip Resurfacing And Total Hip Replacement, C. R. Deuel, A. A. Jamali, S. M. Stover, S J. Hazelwood Jan 2009

Alterations In Femoral Strain Following Hip Resurfacing And Total Hip Replacement, C. R. Deuel, A. A. Jamali, S. M. Stover, S J. Hazelwood

Biomedical Engineering

Bone surface strains were measured in cadaver femora during loading prior to and after resurfacing of the hip and total hip replacement using an uncemented, tapered femoral component. In vitro loading simulated the single-leg stance phase during walking. Strains were measured on the medial and the lateral sides of the proximal aspect and the middiaphysis of the femur. Bone surface strains following femoral resurfacing were similar to those in the native femur, except for proximal shear strains, which were significantly less than those in the native femur. Proximomedial strains following total hip replacement were significantly less than those in the …


A Novel Method For Characterization Of Peripheral Nerve Fiber Size Distributions By Group Delay, Robert B. Szlavik Dec 2008

A Novel Method For Characterization Of Peripheral Nerve Fiber Size Distributions By Group Delay, Robert B. Szlavik

Biomedical Engineering

The ability to determine the characteristics of peripheral nerve fiber size distributions would provide additional information to clinicians for the diagnosis of specific pathologies of the peripheral nervous system. Investigation of these conditions, using electrodiagnostic techniques, is advantageous in the sense that such techniques tend to be minimally invasive yet provide valuable diagnostic information. One of the principal electrodiagnostic tools available to the clinician is the nerve conduction velocity test. While the peripheral nerve conduction velocity test can provide useful information to the clinician regarding the viability of the nerve under study, it is a single-parameter test that yields no …


Design And Optimization Of A Blood Vessel Mimic Bioreactor System For The Evaluation Of Intravascular Devices In Simple And Complex Vessel Geometries, Sara M. Leifer Nov 2008

Design And Optimization Of A Blood Vessel Mimic Bioreactor System For The Evaluation Of Intravascular Devices In Simple And Complex Vessel Geometries, Sara M. Leifer

Master's Theses

Coronary artery disease affects millions of people and the ability to detect and treat the disease is advancing at a rapid rate. As a result, the development of intravascular technologies is the focus of many medical device manufacturers. Specifically, coronary stent implantation is being performed in an increasing number of patients and a number of new stent designs have been introduced to the market, resulting in the need for improved preclinical testing methods. An in vitro tissue engineered “blood vessel mimic” (BVM) system has previously been established and its feasibility for the initial testing of newly emerging intravascular technology has …


Teaching Physiology To Biomedical Engineers Using Team-Based Learning And Inquiry Research, Trevor R. Cardinal Oct 2008

Teaching Physiology To Biomedical Engineers Using Team-Based Learning And Inquiry Research, Trevor R. Cardinal

Biomedical Engineering

Presentation given at conference.


Volume Effects On Yield Strength Of Equine Cortical Bone, R. F. Bigley, J. C. Gibeling, S. M. Stover, S. J. Hazelwood, D. P. Fyhrie, R. B. Martin Oct 2008

Volume Effects On Yield Strength Of Equine Cortical Bone, R. F. Bigley, J. C. Gibeling, S. M. Stover, S. J. Hazelwood, D. P. Fyhrie, R. B. Martin

Biomedical Engineering

Volume effects are a fundamental determinant of structural failure. A material exhibits a volume effect if its failure properties are dependent on the specimen volume. Many brittle ceramics exhibit volume effects due to loading a structure in the presence of “critical” flaws. The number of flaws, their locations, and the effect of stress field within the stressed volume play a role in determining the structure’s failure properties. Since real materials are imperfect, structures composed of large volumes of material have higher probabilities of containing a flaw than do small volumes. Consequently, large material volumes tend to fail at lower stresses …


Fatigue Testing Of Three Peristernal Median Sternotomy Closure Techniques, Cameron Wangsgard, David J. Cohen, Lanny V. Griffin Sep 2008

Fatigue Testing Of Three Peristernal Median Sternotomy Closure Techniques, Cameron Wangsgard, David J. Cohen, Lanny V. Griffin

Biomedical Engineering

Failure of a sternotomy closure because of closure system fatigue is a complication that may result in dehiscence and put the individual at risk for serious complications. The purpose of this study was to assess the fatigue performance of three peristernal median sternotomy closure techniques (figure-of-eight stainless-steel wires, figure-of-eight stainless-steel cables, or Pectofix Dynamic Sternal Fixation [DSF] stainless-steel plates) in order to quantify the potential risk of fatigue failure of these devices when subject to cyclic loads in physiologically relevant loading directions.


A Novel Method For Characterization Of Peripheral Nerve Fiber Size Distributions By Group Delay Measurements And Simulated Annealing Optimization, Robert B. Szlavik, Galen E. Turner, Iii Aug 2008

A Novel Method For Characterization Of Peripheral Nerve Fiber Size Distributions By Group Delay Measurements And Simulated Annealing Optimization, Robert B. Szlavik, Galen E. Turner, Iii

Biomedical Engineering

The ability to determine the characteristics of peripheral nerve fiber size distributions would provide additional information to clinicians for the diagnosis of specific pathologies of the peripheral nervous system. Investigation of these conditions, using electro-diagnostic techniques, is advantageous in the sense that such techniques tend to be minimally invasive yet provide valuable diagnostic information. One of the principal electro-diagnostic tools available to the clinician is the nerve conduction velocity test. While the peripheral nerve conduction velocity test can provide useful information to the clinician regarding the viability of the nerve under study, it is a single parameter test that yields …


Nicotinic Acetylcholine Receptor Kinetics Of The Neuromuscular Junction Simulated Using Spice: An Illustration Of Physiological Process Simulation With Conventional Circuit Simulation Software, Robert B. Szlavik Jun 2008

Nicotinic Acetylcholine Receptor Kinetics Of The Neuromuscular Junction Simulated Using Spice: An Illustration Of Physiological Process Simulation With Conventional Circuit Simulation Software, Robert B. Szlavik

Biomedical Engineering

With the advent of modern day computational power, there is a great deal of interest in the simulation and modeling of complex biological systems. A significant effort is being made to develop generalized software packages for the simulation of cellular processes, metabolic pathways and complex biochemical reaction systems. The advantages to being able to implement and simulate complex biological systems in a virtual environment are several. Simulations of this type, if sufficiently detailed, provide experimental physiologists with the ability to visualize the dynamics of a given biological system of interest. The validity of hypotheses related to the system under study …


Action At Distance: A Ms Degree Offered Through Distance Learning As A Vector To Student Enrichment And Industrial Interaction, Lanny Griffin, Daniel Walsh, Robert Crockett, Robert B. Szlavik Jun 2008

Action At Distance: A Ms Degree Offered Through Distance Learning As A Vector To Student Enrichment And Industrial Interaction, Lanny Griffin, Daniel Walsh, Robert Crockett, Robert B. Szlavik

Biomedical Engineering

This paper describes the development and implementation of a flourishing MS program offered through distance learning (DL). The program serves the mission of the university – polytechnic education. It provides an intense life-long-learning opportunity for some of the 300,000 degreed engineers working in California industry who can benefit from graduate education. The DL Masters Degree Program in Engineering with a Biomedical Specialization was designed and developed with verisimilitude to the on-campus program in mind. The distance students attend the same classes as students on campus. The DL program has the same learning objectives and student outcomes as those expected for …


An Automatic Alogorithm For Detecting Stent Endothelialization From Volumetric Optical Coherence Tomography Datasets, Garret T. Bonnema, Kristen O'Halloran Cardinal, Stuart K. Williams, Jennifer K. Barton Jun 2008

An Automatic Alogorithm For Detecting Stent Endothelialization From Volumetric Optical Coherence Tomography Datasets, Garret T. Bonnema, Kristen O'Halloran Cardinal, Stuart K. Williams, Jennifer K. Barton

Biomedical Engineering

Recent research has suggested that endothelialization of vascular stents is crucial to reducing the risk of late stent thrombosis. With a resolution of approximately 10 μm, optical coherence tomography (OCT) may be an appropriate imaging modality for visualizing the vascular response to a stent and measuring the percentage of struts covered with an anti-thrombogenic cellular lining. We developed an image analysis program to locate covered and uncovered stent struts in OCT images of tissue-engineered blood vessels. The struts were found by exploiting the highly reflective and shadowing characteristics of the metallic stent material. Coverage was evaluated by comparing the luminal …


A Case-Study Based Course On "Device Evaluation And Fda Approval", Kristen O'Halloran Cardinal Jun 2008

A Case-Study Based Course On "Device Evaluation And Fda Approval", Kristen O'Halloran Cardinal

Biomedical Engineering

Preclinical evaluation of new devices and therapies is an integral part of research and development in the medical device industry, and the regulatory process for FDA approval is a major driving force behind much that goes on in a company setting. A large number of graduating biomedical engineers enter this medical device industry or a related environment upon graduation from our institution. Although these engineers are equipped to address many of the technical challenges that will arise, there is currently limited formal training in or exposure to the regulatory process that is required to bring new devices to market. Knowledge …


Development Of A Cell Depositing System Using Inkjet Technology, Jason Robert Ozaeta Jun 2008

Development Of A Cell Depositing System Using Inkjet Technology, Jason Robert Ozaeta

Master's Theses

In the past decade, advances in tissue engineering have allowed researchers to fabricate simple tissues. However, the process of creating these native tissues is a time consuming and inefficient process. A scaffold must first be fabricated then exposed to a sea of cells in the hopes of seeding. Furthermore, even though cells may have attached, more time must be spent in order to allow the cells to migrate to their ideal locations. To deal with this problem, researchers have investigated whether rapid prototyping principals could be adapted to facilitate the cell seeding process by placing cells in their respective locations …


Elastic Modulus Of Bone Using Ultrasonic Testing, Lanny Griffin, Victor Yu Jun 2007

Elastic Modulus Of Bone Using Ultrasonic Testing, Lanny Griffin, Victor Yu

Biomedical Engineering

No abstract provided.


Biomedical Engineering Virtual Circuit Simulation Laboratories, Robert B. Szlavik Jun 2007

Biomedical Engineering Virtual Circuit Simulation Laboratories, Robert B. Szlavik

Biomedical Engineering

Circuit simulators, such as SPICE (Simulation Program with Integrated Circuit Emphasis) are useful tools that can enhance the educational experience of students in many subject areas within a biomedical engineering curriculum. Courses on biomedical instrumentation are venues for which virtual laboratory experiments, using circuit simulators, can be readily developed. The instructor can use the circuit simulation platform to illustrate relatively complex concepts, such as differential amplification, which have wide applicability to biomedical instrumentation. More advanced courses that focus on the physiology of excitable cells or neural modeling and simulation are also venues for which circuit simulators may be applied to …


Biomedical Engineering Simulation Using Visual Basic Macros In Micrsoft Excel, Lanny Griffin, Robert Crockett Jun 2007

Biomedical Engineering Simulation Using Visual Basic Macros In Micrsoft Excel, Lanny Griffin, Robert Crockett

Biomedical Engineering

No abstract provided.


Biomaterials Screening Experiment Using Sessile Drop Contact Angles, Lanny Griffin Jun 2007

Biomaterials Screening Experiment Using Sessile Drop Contact Angles, Lanny Griffin

Biomedical Engineering

No abstract provided.


Simulated Effects Of Marathon Training On Bone Density, Remodeling, And Microdamage Accumulation Of The Femur, Scott J. Hazelwood, Alesha B. Castillo Jun 2007

Simulated Effects Of Marathon Training On Bone Density, Remodeling, And Microdamage Accumulation Of The Femur, Scott J. Hazelwood, Alesha B. Castillo

Biomedical Engineering

Stress fractures are mechanically induced injuries resulting from fatigue damage to bone due to repetitive loading and are common injuries occurring in runners. In this study, we used computer simulations of marathon training programs to examine the effects of endurance running on femoral density, remodeling, and microdamage accumulation. Simulated remodeling activity increased in the femoral neck and proximal cortex and predicted microdamage increased in all regions examined after 16 weeks for each program. Daily running for three years produced more microdamage than the advanced training schedule over the same time period. Areas of high remodeling and damage corresponded to clinically …


The Use Of Hinged External Fixation To Provide Additional Stabilization For Fractures Of The Distal Humerus, Christopher R. Deuel, Philip Wolinsky, Eric Shepherd, Scott Hazelwood May 2007

The Use Of Hinged External Fixation To Provide Additional Stabilization For Fractures Of The Distal Humerus, Christopher R. Deuel, Philip Wolinsky, Eric Shepherd, Scott Hazelwood

Biomedical Engineering

Objective: To assess improvements in fixation stability when a hinged unilateral external fixator is used to supplement compromised internal fixation for distal humerus fractures.

Methods: Removing a 1-cm section of the distal humerus in cadaveric whole-arm specimens created a comminuted distal humerus fracture model (AO type 13-A3). Fixation was then performed using different constructs representing optimal, compromised, or supplemented internal fixation. Internal fixation consisted of either 2 reconstruction plates with 1, 2, or 3 (optimal) distal attachment screws, or crossing medial and lateral cortical screws. A hinged external fixator was applied in combination with compromised internal fixation. The stability of …


A Bimodular Polyconvex Anisotropic Strain Energy Function For Articular Cartilage, Stephen M. Klisch Apr 2007

A Bimodular Polyconvex Anisotropic Strain Energy Function For Articular Cartilage, Stephen M. Klisch

Mechanical Engineering

A strain energy function for finite deformations is developed that has the capability to describe the nonlinear, anisotropic, and asymmetric mechanical response that is typical of articular cartilage. In particular, the bimodular feature is employed by including strain energy terms that are only mechanically active when the corresponding fiber directions are in tension. Furthermore, the strain energy function is a polyconvex function of the deformation gradient tensor so that it meets material stability criteria. A novel feature of the model is the use of bimodular and polyconvex “strong interaction terms” for the strain invariants of orthotropic materials. Several regression analyses …