Open Access. Powered by Scholars. Published by Universities.®
Biomedical Engineering and Bioengineering Commons™
Open Access. Powered by Scholars. Published by Universities.®
- Discipline
-
- Biomedical Devices and Instrumentation (213)
- Other Biomedical Engineering and Bioengineering (110)
- Mechanical Engineering (67)
- Molecular, Cellular, and Tissue Engineering (67)
- Biomechanics and Biotransport (65)
-
- Biomaterials (52)
- Electrical and Computer Engineering (44)
- Biological Engineering (43)
- Medicine and Health Sciences (38)
- Biomechanical Engineering (34)
- Bioimaging and Biomedical Optics (33)
- Bioelectrical and Neuroengineering (32)
- Biomedical (29)
- Life Sciences (25)
- Electrical and Electronics (24)
- Manufacturing (23)
- Materials Science and Engineering (23)
- Systems and Integrative Engineering (23)
- Analytical, Diagnostic and Therapeutic Techniques and Equipment (16)
- Computer-Aided Engineering and Design (14)
- Polymer and Organic Materials (14)
- Computer Engineering (13)
- Applied Mechanics (11)
- Other Mechanical Engineering (9)
- Diseases (8)
- Physical Sciences and Mathematics (8)
- Physiology (8)
- Biology and Biomimetic Materials (7)
- Keyword
-
- Arteriogenesis (23)
- Biomechanics (20)
- Ischemia (20)
- Microfluidics (18)
- Tissue Engineering (13)
-
- Electrospinning (12)
- Prosthetic (11)
- Tissue engineering (11)
- Angiogenesis (9)
- Bone (9)
- Gait (9)
- Scaffold (9)
- COMSOL (8)
- Electrophysiology (8)
- Endothelial Dysfunction (8)
- Myoblast (8)
- Device (7)
- FEA (7)
- Finite Element Analysis (7)
- Osteoporosis (7)
- Peripheral arterial occlusive disease (7)
- Vasodilation (7)
- Baseball (6)
- Biomedical (6)
- Collateral circulation (6)
- Cycling (6)
- Diabetes (6)
- Medical device (6)
- Microfluidic (6)
- PLGA (6)
- Publication Year
- Publication
- Publication Type
- File Type
Articles 421 - 450 of 643
Full-Text Articles in Biomedical Engineering and Bioengineering
Stent Graft Blush, Vanessa Barrett, Thomas Matzinger, Mike Morelli
Stent Graft Blush, Vanessa Barrett, Thomas Matzinger, Mike Morelli
Mechanical Engineering
In order to better understand Type IV endoleaks (“blush”), the Cal Poly Senior Project team GraftTest has developed a blush evaluation system able to mimic several of the aorta’s environmental parameters. Capable of both pressure and flow rate control, this bench top system accommodates Medtronic’s wide range of abdominal and thoracic aortic stent grafts. Having researched endoleaks, stent grafts, and numerous other factors affecting stent graft blush, a system was developed with the aim of assessing and comparing the performance of Medtronic’s stent grafts with regard to blush. Furthermore, this system has been designed to provide reliable and repeatable results …
Guidance System, Kayaking For The Visually Impaired, D. Ryan Kirtland, Ryan Phife, William Gardner, Amy Johnson
Guidance System, Kayaking For The Visually Impaired, D. Ryan Kirtland, Ryan Phife, William Gardner, Amy Johnson
Biomedical Engineering
Quality Life Plus is working with Team River Runner to develop an assistive guidance system for veterans who want to remain active by kayaking, after sustaining an injury that impairs vision. This system allows these veterans to complete a slalom speed race independent of a personal guide in the water. The system incorporates 3 stations that each contain a speaker connected to a microcontroller system covered by a Pelican Case on a custom made buoy. During the slalom race, a kayaker will travel from shore towards buoy #1 as it omits sound from the speaker. As the kayaker moves around …
Evaluation Of Thermophile Algae In Horizontal Photo-Bioreactor, Olivier Schmied
Evaluation Of Thermophile Algae In Horizontal Photo-Bioreactor, Olivier Schmied
BioResource and Agricultural Engineering
No abstract provided.
Matrix Remodeling Accompanies In Vitro Articular Cartilage Spherical Shaping, Nathan Thomas Balcom
Matrix Remodeling Accompanies In Vitro Articular Cartilage Spherical Shaping, Nathan Thomas Balcom
Master's Theses
Introduction: Articular cartilage (AC) is a low friction load bearing material found in synovial joints. The natural repair of damaged tissue is difficult and often requires surgical intervention. With large defects it becomes necessary to match the original tissue geometry. We hypothesized that localized collagen (COL) and/or proteoglycan (PG) remodeling occurs during AC spherical reshaping. The objective of this study was to determine the presence, magnitude and depth dependence of COL and PG remodeling that accompanies AC reshaping. Methods: Full thickness AC blocks (7x7 mm2 surface area) were harvested from the ridges of the patellofemoral groove of immature (1-3 …
Tracking Points On A Pacing Lead In A Beating Heart, Avinash Ramesh Varma
Tracking Points On A Pacing Lead In A Beating Heart, Avinash Ramesh Varma
Master's Theses
Heart failure is a common condition during which the pumping action of the heart is affected because the heart does not contract or relax properly. Heart failure affects about 5 million Americans, with 550,000 new cases diagnosed each year. Cardiac resynchronization therapy (CRT) is used to treat symptoms and other complications associated with a heart failure. While performing CRT, Implantation of a pacing lead in the left ventricle of the heart is a very challenging surgical procedure performed with fluoroscopy. The target location is often difficult to reach through the tortuous coronary venous anatomy, which varies greatly among individuals. Placement …
The Effect Of A Triphasic Pulse On Scs To Icd Crosstalk, Ryan James Wensley
The Effect Of A Triphasic Pulse On Scs To Icd Crosstalk, Ryan James Wensley
Master's Theses
It is a known problem that a Spinal Cord Stimulator (SCS) can interact with an Implantable Cardioverter Defibrillator (ICD) when both devices are implanted in the same patient. Interactions between the SCS and ICD can cause inappropriate therapy which can be harmful to the patient. While ICD devices have a distinct narrowband sensing bandwidth, the pulse configurations that current SCS devices deliver were not designed with this frequency region in mind. In this thesis, I recommend a new pulse configuration for SCS devices that will minimize the interaction between the two devices. I produce a theoretical equation for each pulse …
Evaluation Of The Anterior Talofibular And Calcaneofibular Ligament In Relation To Supination Ankle Sprains, Peter Tran
Evaluation Of The Anterior Talofibular And Calcaneofibular Ligament In Relation To Supination Ankle Sprains, Peter Tran
Biomedical Engineering
Ankle injuries have always posed an issue to a number of athletes. Sports that involve running and jumping accumulate about 25% of injuries correlating to ankle sprains. In most ankle sprains the inversion (supination) of the ankle cause damage to lateral ligaments. The two most common lateral ligaments to experience damage are the anterior talofibular (ATFL) and calcaneofibular (CFL) ligaments. The methods of taping and ankle braces have allowed athletes to prevent recurring sprains from occurring. However, sprains can still occur even when one or both methods are applied. The purpose of each method is to restrict the range of …
Shelf Life Study Of Electrospun Plga Copolymers, Sean Youra, Nick Hudson
Shelf Life Study Of Electrospun Plga Copolymers, Sean Youra, Nick Hudson
Biomedical Engineering
Poly(lactic-co-glycolic acid) (PLGA) is one of the most commonly used copolymers for electrospinning in tissue engineering applications. However, most research has not focused on the copolymer itself in regards to how long it can be used effectively and if varying the concentrations of polylactic acid (PLA) and polyglycolic acid (PGA) affect the resulting properties. Electrospinning is the method we use to create the three-dimensional constructs, or “scaffolds”, for the blood vessel mimic (BVM) in the tissue engineering lab. The aim of our project was to investigate if the morphology and mechanical properties of the scaffolds changed over time when they …
Analysis Of Acetabular Cup Orientation Effects On Stress Shielding In Total Hip Replacements Using Finite Element Methods, Brogan Mcguire, Jennifer Gemkow, Brad Gausewitz, Alex Georges
Analysis Of Acetabular Cup Orientation Effects On Stress Shielding In Total Hip Replacements Using Finite Element Methods, Brogan Mcguire, Jennifer Gemkow, Brad Gausewitz, Alex Georges
Biomedical Engineering
Improper positioning of the acetabular cup has been shown to contribute to issues such as high wear rates and dislocations in total hip replacements. The differences in contact mechanics due to varying orientation of the acetabular cup may also significantly affect strain distribution in the femur. This study examined these effects of acetabular orientation changes and their contribution to stress shielding using finite element analysis. A solid model of a cementless total hip implant was obtained using 3D point scanning and implanted virtually into a femur solid model. The implanted femur model was imported into ABAQUS and loaded with a …
Effect Of Oral Lipids On Blood Glucose, Tyler R. Knisley
Effect Of Oral Lipids On Blood Glucose, Tyler R. Knisley
Biomedical Engineering
Diabetes mellitus is a disease in which insulin hormone is ineffective or no longer produced. Multiple pathophysiologies can cause either insulin dependent diabetes mellitus (IDDM) or insulin independent diabetes mellitus (IIDM), which can lead to chronic hyperglycemia and an array of short and long term health risks. Prior research has shown that IDDM patients have dyslipidemia, and experiments infusing lipids directly into the blood result in heightened insulin resistance. The hypothesis that dyslipidemia increases insulin resistance was tested by performing oral glucose tolerance tests across three treatment conditions. Participants were nondiabetic college-aged students. Data from a control group was gathered …
A Mouse Model Of Aortic Endothelial Denudation And Neointimal Formation, Ashkon C. Nehzati
A Mouse Model Of Aortic Endothelial Denudation And Neointimal Formation, Ashkon C. Nehzati
Biomedical Engineering
More than 385,000 people die from coronary heart disease (CHD) annually and treatment costs $108.9 billion each year including the cost of health care services, medications, and lost productivity. CHD decreases heart function by limiting oxygen and nutrient transport carried through the coronary arteries. A complete block to the coronary arteries causes a myocardial infarction in response to an elimination of blood supply to cardiomyocytes. Partial occlusion results in insufficient blood supply to cardiomyocytes, producing myocardial ischemia and angina, which are usually treated with intravascular stents deployed percutaneously, before myocardial infarction occurs. Stents are the most common ways to expand …
Modeling The Zimmer Fitmore And Ml Taper Implantation, Tyler Kazuo Franklin
Modeling The Zimmer Fitmore And Ml Taper Implantation, Tyler Kazuo Franklin
Master's Theses
With more young adults requiring total hip
arthroplasties the need for bone saving implants becomes
more important. The Zimmer Fitmore is a new bone saving
implant that utilizes an implantation technique that
reduces the damage to the muscle tissue allowing for
patients to have a short recovery time as well as a new
design that allows it to rest on the medial cortex. There
has been anecdotal evidence that this device leads to early
revision within six months of implantation due to failures
occurring in the medial cortex. The main goal of this
study was to computationally model the Zimmer …
Design Of An Experimental Approach To Study The Growth Of Biofilm On Polymethylmethacrylate, Eireen S. Escalona
Design Of An Experimental Approach To Study The Growth Of Biofilm On Polymethylmethacrylate, Eireen S. Escalona
Biomedical Engineering
Biofilms are present in virtually every solid-liquid contact surface and are partially responsible for some diseases and water cleaning. They are a community of a variety of organisms that live symbiotically and are bound together by extracellular polymeric substances, or EPS. Biofilms go through five stages of development. These include initial and irreversible attachments, maturations I and II, and dispersion. In the dental world, biofilms are often associated with mouth infections including dental caries, gingivitis and periodontitis. Elderly denture wearers are susceptible to the pathogen-causing bacteria associated with these diseases, particularly those who have Alzheimer's disease or other forms of …
Finite Element Analysis Of The Nerve Cuff To Determine Usability And Stress Analysis During Regular Use, Vivek Machhi
Finite Element Analysis Of The Nerve Cuff To Determine Usability And Stress Analysis During Regular Use, Vivek Machhi
Biomedical Engineering
To determine the stress analysis on the Nerve Cuff by MicroProbes, a finite element analysis was conducted. A simplified model was created in Solid Works using the geometry of the basic model of the nerve cuff. The solid model was then imported into Abaqus and the appropriate materials, boundary conditions, and loads were designated. Initially a tensile test simulation was conducted using a tensile force of 2.87 Newtons. The maximum stress experienced with this tensile force was 8.225 MPa which was greater than the ultimate tensile strength of 5.5 MPa of Silicone. Both the actual tensile test and the tensile …
Novel Approach To Junctional Bleeding: Tourniquet Device Proposal For Battlefield Hemorrhage Control, Kyle W. Cabaniss
Novel Approach To Junctional Bleeding: Tourniquet Device Proposal For Battlefield Hemorrhage Control, Kyle W. Cabaniss
Master's Theses
This study investigated possible solutions to the current wartime problem of junctional hemorrhaging, or massive traumatic hemorrhaging in non-tourinquetable areas such as the neck, groin, or armpit. Junctional hemorrhaging has been identified as a major contributor to potentially survivable deaths seen on the battlefield today and therefore is a priority for the U.S. armed and coalition forces (Kragh et al., 2011a; Bozeman, 2011). Common tourniquets today are standard issue and carried by soldiers in the military, but are limited to distal extremity trauma. As the battlefield has changes however, trauma has transformed from commonly seen gunshot wounds to more extreme …
A Microfluidic Pretreatment Isoelectric Focusing Dc-Field Assisted H-Filter For The Separation Of Charged Particles, Cameron Sean Carroll
A Microfluidic Pretreatment Isoelectric Focusing Dc-Field Assisted H-Filter For The Separation Of Charged Particles, Cameron Sean Carroll
Biomedical Engineering
Microfluidic devices are small portable diagnostic chips that allow for analysis of a biologic sample at relatively low cost. This makes them ideal for settings where a hospital is unavailable. The microfluidic pretreatment isoelectric focusing DC-field assisted H-filter is a device that allows for the separation of differently charged particles in a biologic sample. It does this by employing the concepts of diffusion, electrophoresis, and isoelectric focusing. This is perfect for isolation of a desired analyte or separation of waste from a sample in order to achieve better diagnostic results. The device was first modeled mathematically and visually using Comsol. …
Investigating The Reproducibility Of The Current Bvm Protocol, Corey Gross
Investigating The Reproducibility Of The Current Bvm Protocol, Corey Gross
Biomedical Engineering
Coronary Artery Disease (CAD) is responsible for 1 death every minute in the US. Angioplasty with the implantation of stents is a common treatment method for CAD. Although there is a variety of stents currently on the market, there is still a need to develop new types for different pathologic conditions. Preliminary assessment of the physiological response to new stents is needed as they are being developed. The FDA approval process implemented today is a long, tedious path with a range of testing methods that include static in vitro testing and high-cost animal testing. Tissue engineered blood vessels have been …
Bacterial Growth On Metal And Non-Metal Surfaces In A Static Bioreactor, Rolan Yuk Loong Liong
Bacterial Growth On Metal And Non-Metal Surfaces In A Static Bioreactor, Rolan Yuk Loong Liong
Master's Theses
Research was conducted to observe bacterial growth on the surface of metals in a static bioreactor. Metal and non-metal samples were subjected to bacterial exposure (1 day and 9 days). The metal samples were surface treated prior to bacterial exposure. The microstructures of the surface treated samples were analyzed by optical microscopy. After exposure, the microstructures of the samples were analyzed by scanning electron microscopy (SEM). The analysis suggested that microbial attachment on the surface was related to the underlying microstructure of steel. The preferential attachment of microbes could potentially be influenced by cathodic and anodic regions created by the …
Effects Of Ovariectomy And Anatomical Location On Osteonal Encroachment In Adult Cortical Ovine Bone, Paige Brell Ryan
Effects Of Ovariectomy And Anatomical Location On Osteonal Encroachment In Adult Cortical Ovine Bone, Paige Brell Ryan
Master's Theses
The purpose of this study is to further quantify adult ovine ovariectomized bone for new remodeling characteristics to obtain a better understanding of how remodeling is occurring and the effectiveness of this animal model for the study of postmenopausal osteoporosis. Postmenopausal osteoporosis is a major health concern and animal models to test new treatment options are needed. The ovine model is a good option because the ewes undergo Haversian remodeling, are a large sized animal, and have a similar hormone profile to humans. Ewes, however, do not undergo a natural menopause, so an ovariectomy surgery was conducted in the sheep …
Biomedical Advancements In Injury Recovery, Performance Enhancement, And Mechanical Assistance Applied To Athletics, Matthew Russell
Biomedical Advancements In Injury Recovery, Performance Enhancement, And Mechanical Assistance Applied To Athletics, Matthew Russell
Biomedical Engineering
Athletics is constantly changing, and athletes are continually getting bigger, faster, and stronger. At the same time, biomedical technology and innovation is rapidly developing. New methods of injury recovery, genetic enhancement, and prosthetic assistance are being assimilated into the athletic world. The up and coming athlete needs to be aware of all of the usable information around them. This project is an accumulation of some of the cutting edge advancements in those fields. Platelet Rich Plasma Injections, Frequency Specific Microcurrent Treatment, and Silk Polymer Anterior Cruciate Ligament Replacement are innovative new ways to treat common sports injuries. Performance enhancement has …
A Biomechanical Comparison Of Three Spondylolysis Repair Techniques In A Calf Spine Model, R. Roberto, B. Dezfuli, C. Deuel, S. Curtiss, S. Hazelwood
A Biomechanical Comparison Of Three Spondylolysis Repair Techniques In A Calf Spine Model, R. Roberto, B. Dezfuli, C. Deuel, S. Curtiss, S. Hazelwood
Biomedical Engineering
Summary of background data: Previous work has demonstrated the efficacy of lumbar pedicle screw hook rod (PSHR) techniques and the Buck screw in the stabilization of spondylolysis. The mechanical behavior of lower profile cervical implants used to create PSHR, hybrid cable plate constructs, and titanium miniplating has not previously been described.
Methods: Calf lumbar spines (L2-L6) were utilized for testing (n = 27). Intervertebral rotation was measured in the intact spines across the L4-5 segment before and after creation of bilateral pars interarticularis defects. Defects were then stabilized with one of three repair techniques, PSHR, miniplate, or …
Slowing The Onset Of Hypoxia Increases Colony Forming Efficiency Of Connective Tissue Progenitor Cells In Vitro, Christopher M. Heylman, Tonya N. Caralla, Cynthia A. Boehm, Thomas E. Patterson, George F. Muschler
Slowing The Onset Of Hypoxia Increases Colony Forming Efficiency Of Connective Tissue Progenitor Cells In Vitro, Christopher M. Heylman, Tonya N. Caralla, Cynthia A. Boehm, Thomas E. Patterson, George F. Muschler
Biomedical Engineering
Background: Survival and colony formation by transplanted tissue derived connective tissue progenitor cells (CTPs) are thought to be important factors in the success of clinical tissue engineering strategies for bone regeneration. Transplantation of cells into defects larger than a few millimeters expose cells to a profoundly hypoxic environment. This study tested the hypothesis that delaying the onset of hypoxia will improve the survival and performance of CTPs in vitro.
Methods: To mimic declines seen in an avascular in vivo bone defect, colony forming efficiency by marrow derived nucleated cells was assessed under osteogenic conditions. Variation in the rate of …
Measuring Impedance Of Tissues Using A Microfabricated Microelectrode Array, Ashwini Bhat
Measuring Impedance Of Tissues Using A Microfabricated Microelectrode Array, Ashwini Bhat
Master's Theses
MEASURING IMPEDANCE OF TISSUES USING A MICROFABRICATED MICROELECTRODE ARRAY By Ashwini Bhat
This thesis looks at the possibility of using impedance spectroscopy for differentiating tissue, using a microelectrode array (MEA). The thesis first discusses the background and the motivation for this thesis. It covers the certain basic concepts of the human skin starting from the top epidermis layer all the way to the deep dermis layers of the skin. Then it discusses different types of skin cancer and how they occur, in humans. It also discusses various microfabrication techniques such as oxidation, wet etching, sputtering and photolithography for the creation …
Handitrike - Recumbent Tricycle, Sean Higginson, Kevin Howie, Vinay Patel
Handitrike - Recumbent Tricycle, Sean Higginson, Kevin Howie, Vinay Patel
Mechanical Engineering
This report covers the design and construction of the recumbent racing tricycle for Mr. Robert T. Kelly, a disabled veteran. Unfortunately Rob’s right leg is five inches shorter than his left one and therefore is unable to properly operate standard cranks. Our team HandiTrike is composed of Sean Higginson, Kevin Howie, and Vinay Patel and our project requires us to come up with a design that is feasible to complete within the given three quarters, as well as allow Rob to gain full use of his tricycle. Currently Rob ‘s trike uses the standard crank set up found on most …
Development Of Simulation Platform For Oropharyngeal Airway Placement And Design Evaluation Of The Bardo Airway, Lewis On Hang Lee
Development Of Simulation Platform For Oropharyngeal Airway Placement And Design Evaluation Of The Bardo Airway, Lewis On Hang Lee
Master's Theses
Off-label use of traditional Oropharyngeal Airway (OPA) as a bite-block, and the subsequential procedure of force exertion of the device by physician has caused many cases of patient’s teeth damage and monetary loss, as the patient’s incisors were damaged while clenching on the OPA during an adverse scenario called “Emergency Clenching”. To remedy this harmful situation, Bardo OPA was developed by Dr. Theodore Burdumy. The Bardo airway has unique design to transfer the clenching force from incisor to the molar. However, the Bardo OPA is one-sized, and cannot fit most of the patients like the commonly-used OPAs, such as the …
Implementation Of Novel Group Delay Decomposition Method And Surgical Protocol For Assessing Peripheral Neuropathy, Sammy Paul Nicolas
Implementation Of Novel Group Delay Decomposition Method And Surgical Protocol For Assessing Peripheral Neuropathy, Sammy Paul Nicolas
Master's Theses
This paper outlines a surgical procedure for exposing and stimulating the sciatic nerve of an anesthetized rodent for purposes of obtaining conduction velocity readings. The ability to accurately quantify nerve conduction velocity has potential for use in the field of diagnostic medicine and disease characterization. An accurate reading depends on both the surgical method used to expose the desired nerve without imposing onto it any physical trauma as well as the stimulation protocol used to initiate action potentials. This paper contains the specific steps required to set up the necessary hardware and software for electrical stimulation as well as a …
Hydrodynamic Focused Passive Separation Under Continuous Flow In A Microfluidic Chip, Jad Kanbar
Hydrodynamic Focused Passive Separation Under Continuous Flow In A Microfluidic Chip, Jad Kanbar
Master's Theses
A continuous flow, passive separation device was designed using an equivalent circuit to create variable flow rates for hydrodynamic focusing to drain channels and collection outlets. By varying the diameter of the sample inlet connection into the reservoir, the particle position was influenced significantly, which enabled desired separations. Additionally it was noted that the relative, horizontal position of the inlet also had a significant influence on particle position within the device. A dimensionless number, the Characteristic Sample Inlet, was developed to relate geometric properties of the inlet reservoir to downstream particle distribution. It was found that a 2:1 ratio between …
Responding To Dangerous Accidents Among The Elderly: A Fall Detection Device With Zigbee-Based Positioning, Michael R. Putnam
Responding To Dangerous Accidents Among The Elderly: A Fall Detection Device With Zigbee-Based Positioning, Michael R. Putnam
Master's Theses
The following paper describes a fall detection and activity monitoring system with position detection based on Zigbee transceivers.The main objective is to reduce the time taken for emergency personnel to respond to falls among the elderly. Especially when the victim is unconscious or delirious, position tracking reduces location determination time within a busy hospital or nursing home environment and facilitates immediate treatment. Reduced response times correlate to decreased morbidity and mortality rates. Background is provided on the major wireless network advances currently deployed in a healthcare setting for asset and personnel tracking, etiology of falls, and several methods of detecting …
Tissue Engineering A Blood Vessel Mimic While Monitoring Contamination Through Sterility Assurance Testing, Navid Djassemi
Tissue Engineering A Blood Vessel Mimic While Monitoring Contamination Through Sterility Assurance Testing, Navid Djassemi
Master's Theses
Tissue Engineering A Blood Vessel Mimic While Monitoring Contamination Through Sterility Assurance Testing
Navid Djassemi
Tissue engineering blood vessel mimics has been proposed as a method to analyze the endothelial cell response to intravascular devices that are used in today’s clinical settings for the treatment of cardiovascular disease. Thus, the development of in vitro blood vessel mimics (BVMs) in Cal Poly’s Tissue Engineering Lab has introduced the possibility of assessing the characteristics of cellular response to past, present, and future intravascular devices that aim at treating coronary artery disease.
This thesis aimed at improving the methods and procedures utilized in …
Development Of In Vitro Tissue Engineered Blood Vessel Mimics In Complex Geometries For Coronary Stent Testing, Robert Dalton Chavez
Development Of In Vitro Tissue Engineered Blood Vessel Mimics In Complex Geometries For Coronary Stent Testing, Robert Dalton Chavez
Master's Theses
Coronary heart disease is the leading cause of death in the United States and occurs when plaque occludes coronary arteries. Coronary stents, which may be used to treat coronary occlusions, are small metal tubes that are implanted in coronary arteries to restore blood flow. After stent implantation, endothelial cells grow over the stent so that blood contacts the endothelial cells instead of the stent surface; this event is known as re-endothelialization. Re-endothelialization prevents blood from clotting on the stent surface and is a good predictor of stent success. Blood vessel mimics (BVMs) are in vitro tissue engineered models of human …