Open Access. Powered by Scholars. Published by Universities.®
Biomedical Engineering and Bioengineering Commons™
Open Access. Powered by Scholars. Published by Universities.®
- Discipline
-
- Biomedical Devices and Instrumentation (213)
- Other Biomedical Engineering and Bioengineering (110)
- Mechanical Engineering (67)
- Molecular, Cellular, and Tissue Engineering (67)
- Biomechanics and Biotransport (65)
-
- Biomaterials (52)
- Electrical and Computer Engineering (44)
- Biological Engineering (43)
- Medicine and Health Sciences (38)
- Biomechanical Engineering (34)
- Bioimaging and Biomedical Optics (33)
- Bioelectrical and Neuroengineering (32)
- Biomedical (29)
- Life Sciences (25)
- Electrical and Electronics (24)
- Manufacturing (23)
- Materials Science and Engineering (23)
- Systems and Integrative Engineering (23)
- Analytical, Diagnostic and Therapeutic Techniques and Equipment (16)
- Computer-Aided Engineering and Design (14)
- Polymer and Organic Materials (14)
- Computer Engineering (13)
- Applied Mechanics (11)
- Other Mechanical Engineering (9)
- Diseases (8)
- Physical Sciences and Mathematics (8)
- Physiology (8)
- Biology and Biomimetic Materials (7)
- Keyword
-
- Arteriogenesis (23)
- Biomechanics (20)
- Ischemia (20)
- Microfluidics (18)
- Tissue Engineering (13)
-
- Electrospinning (12)
- Prosthetic (11)
- Tissue engineering (11)
- Angiogenesis (9)
- Bone (9)
- Gait (9)
- Scaffold (9)
- COMSOL (8)
- Electrophysiology (8)
- Endothelial Dysfunction (8)
- Myoblast (8)
- Device (7)
- FEA (7)
- Finite Element Analysis (7)
- Osteoporosis (7)
- Peripheral arterial occlusive disease (7)
- Vasodilation (7)
- Baseball (6)
- Biomedical (6)
- Collateral circulation (6)
- Cycling (6)
- Diabetes (6)
- Medical device (6)
- Microfluidic (6)
- PLGA (6)
- Publication Year
- Publication
- Publication Type
- File Type
Articles 211 - 240 of 643
Full-Text Articles in Biomedical Engineering and Bioengineering
D.I.Y. Clean Hood, Samuel G. Porter, Ryan E. Shimogaki, Ryan S. Staples
D.I.Y. Clean Hood, Samuel G. Porter, Ryan E. Shimogaki, Ryan S. Staples
Biomedical Engineering
The DIY Clean Hood is a low-cost, sterile, and accessible scientific workspace intended for installation in the BioElectroFluidics Lab of California Polytechnic State University’s (San Luis Obispo) Biomedical Engineering Department (BMED), under the sponsorship of Dr. Benjamin Hawkins, PhD. As normal Clean Hood, Biosafety Cabinets, and the like are generally too expensive for a university, a competitive solution to an expensive problem can assist research students and professors alike continue their own work with an inexpensive yet effective environment.
Specific design elements that the customer requirements entailed for the project include a low-particle-count air filtration system, positive pressure air flow …
Sandy Feet, Garrett E. Herbst, Jacqueline Chuang, Jerin T. Brust, Parker S. Duncan
Sandy Feet, Garrett E. Herbst, Jacqueline Chuang, Jerin T. Brust, Parker S. Duncan
General Engineering
Sgt. Brady is a former armed forces member with a transtibial amputation. He walks on sand frequently for work and leisure, but experiences severe pain and inconvenience because his current prosthesis is not meant for use on sand. Sand Foot V2 is a prosthesis that allows Sgt. Brady to walk on sand for long periods of time without issue.
Mountain Arm, Conner Magnuson, Amanda Lingle, Jordan Ambrose, Marco Lopez
Mountain Arm, Conner Magnuson, Amanda Lingle, Jordan Ambrose, Marco Lopez
General Engineering
QL+ Challenger, US Navy Veteran, and transhumeral amputee Cassie Perando needed a way to backpack comfortably and independently while wearing a transhumeral prosthesis, as this is something that she enjoys doing often. The current prosthesis she wears causes pinching while wearing a backpack. To eliminate this issue, we decided to design and create a dynamic, pin-lock socket. This design decision allowed for a comfortable fit for Cassie that will not interfere with the backpack straps. As a secondary suspension system, we designed a sports bra with straps that attach to her opposing side and connect to the front and the …
Design Of Prototype Prosthesis For A Canine With A Right Front Limb Deformity As An Alternate Approach To Stabilize Gait And Withstand Gait Forces, Tayler R. Kastlunger
Design Of Prototype Prosthesis For A Canine With A Right Front Limb Deformity As An Alternate Approach To Stabilize Gait And Withstand Gait Forces, Tayler R. Kastlunger
Master's Theses
Congenital and developmental limb deformities in canines are rare and can occur as a genetic disorder or be caused by extrinsic factors. Without surgery to correct the deformity, conservative management can be implemented to manage exercise and restrict high-intensity activity of the canine. However, any alteration to the normal gait and locomotive biomechanics of a canine can have significant long-term effects on the musculoskeletal health and quality of life of the canine. To improve quality of life and provide an alternative and more cost-effective approach to surgery, a custom prosthetic was designed and developed for a canine born with a …
Septal Closure Device, Olivia N. Welch, Hillal H. Jarrar, Kai Harrison
Septal Closure Device, Olivia N. Welch, Hillal H. Jarrar, Kai Harrison
Biomedical Engineering
The septal closure device was designed to seal defects in the atrial septum. To fully seal an atrial defect, the device was designed to consist of two circular seals to cover the defect in both the right and left atria, attached with a central rod. The materials were chosen for compressibility (for ease of insertion), biocompatibility, and tissue ingrowth. A CAD model was drafted in SolidWorks. Key customer requirements include ease of implantation (specifications: adjustable sizing and clear directions for use), physician controlled (specifications: short implantation time and compatibility with current catheter/scope techniques), and a long lifetime (specifications: materials that …
Opendrop Elisa: Surface Development For Digital Microfluidic Elisa Testing, Michaela Q. Mead, Madeline G. Jackson, Jacob G. Taylor
Opendrop Elisa: Surface Development For Digital Microfluidic Elisa Testing, Michaela Q. Mead, Madeline G. Jackson, Jacob G. Taylor
Biomedical Engineering
This project aimed to develop a process to create a hydrophobic coating with capture antibodies attached. This process was developed in an attempt to create a digital microfluidic platform upon which an enzyme-linked immunosorbent assay (ELISA) could be run, indicated for clinicians and educators in low-resource settings. Four requirements dictated the course of the design process: 1) the contact angle with water of the hydrophobic layer must be greater than 90º, 2) the colorimetric response of a positive ELISA result on our platform must be at least 85% of that run on polystyrene with the same result, 3) the platform …
Inverse Dynamics Analysis Of Youth Pitching Arm Kinetics Using Body Composition Imaging, Jay A. Sterner, Scott K. Reaves, Arnel L. Aguinaldo, Scott Hazelwood, Stephen M. Klisch
Inverse Dynamics Analysis Of Youth Pitching Arm Kinetics Using Body Composition Imaging, Jay A. Sterner, Scott K. Reaves, Arnel L. Aguinaldo, Scott Hazelwood, Stephen M. Klisch
Biomedical Engineering
This study’s objectives were to: (1) assess whether dual energy X-ray absorptiometry (DXA)-mass inverse dynamics (ID) alters predictions of youth pitching arm kinetics and (2) investigate correlations between kinetics and body composition. Eighteen 10- to 11-year-olds pitched 10 fastballs. DXA scans were conducted to obtain participant-specific upper arm, forearm, and hand masses. Pitching arm segment masses and kinetics calculated with scaled and DXA masses were compared with paired t-tests and correlations were investigated with linear regression. Hand (p < 0.001) and upper arm (p < 0.001) DXA masses were greater, while forearm (p < 0.001) DXA masses were lesser, than their scaled masses. Shoulder compressive force (p < 0.001), internal rotation torque (p < 0.001), and horizontal adduction torque (p = 0.002) increased when using DXA masses. Shoulder compressive force correlated with body mass (p < 0.001) and body mass index (BMI; p = 0.002) and elbow varus torque correlated with body mass (p < 0.05). The main conclusions were that (1) using participant-specific mass ratios leads to different predictions of injury-related pitching arm kinetics and, thus, may improve our understanding of injury risk factors; and (2) pitching arm kinetics were correlated with body composition measures and a relatively high total body mass and/or BMI may increase shoulder and/or elbow injury risk.
Subject-Specific Finite Element Models Of The Human Knee For Transtibial Amputees To Analyze Tibial Cartilage Pressure For Gait, Cycling, And Elliptical Training, Jonathon Stearns
Subject-Specific Finite Element Models Of The Human Knee For Transtibial Amputees To Analyze Tibial Cartilage Pressure For Gait, Cycling, And Elliptical Training, Jonathon Stearns
Master's Theses
It is estimated that approximately 10-12% of the adult population suffers from osteoarthritis (OA), with long reaching burdens personally and socioeconomically. OA also causes mild discomfort to severe pain in those suffering from the disease. The incidence rate of OA for individuals with transtibial amputations is much than average in the tibiofemoral joint (TF). It is well understood that abnormal articular cartilage stress, whether that be magnitude or location, increases the risk of developing OA. Finite element (FE) simulations can predict stress in the TF joint, many studies throughout the years have validated the technology used for this purpose. This …
Diy Incubator, Aryan Zia, Grace Spurlock, Garrett Janney
Diy Incubator, Aryan Zia, Grace Spurlock, Garrett Janney
Biomedical Engineering
This project report provides detailed information on designing and building a DIY Incubator. The device is indicated for growing and maintaining BSL-1 mammalian or bacterial cell culture with a temperature control in the range of 25-45°C ± 1°C. The device is made fully programmable via an Arduino, and is structurally designed to fit two T75 cell culture flasks at a time. The device is able to return to a specified temperature set point within 10 minutes and maintains 5% CO2 partial pressure conditions. The incubator has a small physical footprint, with an overall dimension of 22in x 16in x 15.5in …
Solostand, Hau Nhat Doan, Sydney Gray, Celina Dioso
Solostand, Hau Nhat Doan, Sydney Gray, Celina Dioso
Biomedical Engineering
The purpose of this scope of work is to highlight the progress and development of SoloStand sponsored by Derek Herrera, chief technical officer and founder of SpinalSingularity. SoloStand is an attachment to a wheelchair that will benefit paraplegics that use wheelchairs. A portable and customizable attachment to a wheelchair will allow the user to do everyday tasks without transferring into a separate standing wheelchair and travel more easily. This document outlines everything that has been done in fulfillment of our senior project requirements.
Total Knee Arthroplasty Gap Balancer, Christina Grigorian, Andrew Beckley, Alexandra Rockett
Total Knee Arthroplasty Gap Balancer, Christina Grigorian, Andrew Beckley, Alexandra Rockett
Biomedical Engineering
California Polytechnic State University’s Biomedical Engineering Department worked in conjunction with local San Luis Obispo orthopedic surgeon Dr. Dimitri Delagrammaticas. The goal of the project was to create a surgical tool that assists a surgeon in measuring knee gap distance and balancing collateral ligament tension during a total knee arthroplasty (TKA) surgery. The final product of this project was completed in five months and initially began with understanding our sponsor’s expectations for the device. A portion of time was devoted to conducting research to understand the process of a knee replacement surgery, the requirements of the device, and the limitations …
Left Atrial Appendage Printing Process, Areli Reyes, Brandon James Mukai, Mia Noelle Von Knorring
Left Atrial Appendage Printing Process, Areli Reyes, Brandon James Mukai, Mia Noelle Von Knorring
Biomedical Engineering
The left atrial appendage senior design team aims to assist in closing off the left atrial appendage that is susceptible to coagulation due to non-valvular atrial fibrillation. Coagulation in the left atrial appendage (LAA) can be life threatening as it can lead to a stroke. Dr. Chris Porterfield performs a procedure that uses the Boston Scientific Watchman to close the appendage. He finds that sizing the Watchman properly is difficult with limited visuals from live CT scans. He proposed converting the CT scans into a 3D printed model of the left atrial appendage and left atrium so he can visually …
Cumulative Shear In Vitro Model, Jared Olson, Alex Deppe, Braden Andrews
Cumulative Shear In Vitro Model, Jared Olson, Alex Deppe, Braden Andrews
Biomedical Engineering
The purpose of our project is to find a reliable method of Subclinical Atherosclerosis detection by measuring the pressure drop across an artery. This model is intended to display how a pressure change correlates with arterial shear rate, and how a decrease in shear rate is ultimately related to atherosclerosis wherein early detection could prove life saving for millions of patients worldwide.
On-Body Pressure For Subcutaneous Infusion Of Drug, Hannah Cole, Kayla Meacham, Eleanor Moran, Kaylee Voss
On-Body Pressure For Subcutaneous Infusion Of Drug, Hannah Cole, Kayla Meacham, Eleanor Moran, Kaylee Voss
Biomedical Engineering
No abstract provided.
Integrity Testing Of Gas Permeable Silicone Filters, Maggie M. Baker, Thomas P. Humann, Kevin J. Yerina
Integrity Testing Of Gas Permeable Silicone Filters, Maggie M. Baker, Thomas P. Humann, Kevin J. Yerina
Biomedical Engineering
This report investigates the most reasonable, cost efficient, and reliable ways to integrity test a filter made from a permeable silicone membrane for future biomedical and pharmaceutical applications. The goal of the project was to create a fixture that a pharmaceutical company can use to quickly and reliably test the integrity of the filter. A variety of methods are outlined to test the integrity of the filter, after a series of quantitative tests, a single method was established that meet the requirements most thoroughly. The method that was determined to be most effective involves a series of components including a …
Insulative (Direct Current) Dielectrophoretic Foul-Less Filtration In Microfuidic Systems, Matthew A A Whitman
Insulative (Direct Current) Dielectrophoretic Foul-Less Filtration In Microfuidic Systems, Matthew A A Whitman
Master's Theses
Filtration is a technology that is used almost ubiquitously in society from uses raging from filtration of macroparticles from water to pharmaceutical grade filtration products to remove anything larger than a protein. However, with such a wide range of uses, most filtration products have the same issue; membrane clogging (fouling) that prevents continuous use and requires frequent maintenance. This thesis hypothesizes that by applying a direct current (DC) to an insulating array of posts, they will create a foul-less insulative dielectrophoretic filter (iDEP) that does not clog since particles will levitate above the insulating array.
This thesis tested an inherited …
Methods To Increase Algae Biomass Productivity In Raceway Pond Monocultures, Ryan S. Anderson
Methods To Increase Algae Biomass Productivity In Raceway Pond Monocultures, Ryan S. Anderson
Master's Theses
The economics of algae biofuels and bioproducts would be improved by increased biomass productivity. Two studies on this potential are described in this thesis – one on a locally isolated filamentous yellow-green alga and the other on a planktonic strain genetically improved via selective enrichment.
Polycultures have been viewed as productive, stable, and, in some cases, harvestable by natural bioflocculation. Local native strains might have higher productivity than culture collection strains because they are already adapted to local outdoor conditions. In this study, the filamentous yellow-green alga Tribonema minus was isolated from a local volunteer polyculture. Its productivity as a …
Skier's Edge: Biomechanical Analysis, Benjamin T. Johannes
Skier's Edge: Biomechanical Analysis, Benjamin T. Johannes
Master's Theses
ABSTRACT
Skier’s Edge: Biomechanical Analysis
Benjamin T. Johannes
The Skier’s Edge trainer can be used by novice or expert skiers. Testing was performed to analyze if the use of the Skier’s Edge could reduce in shear forces of the valgus moment on the knee joint and anterior cruciate ligament (ACL) due to lesser fatigue of muscle and a higher hamstring to quadricep (H/Q) ratio activity. This leads to a reduction of improper form and an increase in balance. Experiments performed observed the change in muscle activity with the use of the Skier’s Edge over time when compared to other forms …
Prosthetic Thumb, Allison M. Sigdestad, Sahil Sharma, Cale Foreman
Prosthetic Thumb, Allison M. Sigdestad, Sahil Sharma, Cale Foreman
Biomedical Engineering
The Prosthetic Thumb Project is a senior design project completed by Biomedical Engineering Undergraduate students at California Polytechnic State University. This senior design project is aimed at designing a prosthetic thumb for a Cal Poly Pomona student who lost their thumb in an accident last year. The patient has ultimately lost between 30-40% of functionality of his left hand, and so we would like to give him that mobility back. Originally, the patient was worried about having a prosthesis, and wanted something more stagnant that would resemble the look of the thumb he lost. However, after working with him, we …
Esophageal Temperature Mapping And Monitoring Sheath, Nicole M. Rogers, Hillary Johnson, Alexander Silva
Esophageal Temperature Mapping And Monitoring Sheath, Nicole M. Rogers, Hillary Johnson, Alexander Silva
Biomedical Engineering
The purpose of this document is to provide a product development summary for an accessory device that joins an esophageal temperature probe and a mapping catheter together to be used during cardiac ablation. Catheter ablation therapy is performed in the left atrium, utilizing extremely hot or cold temperatures to create scar tissue and treat atrial fibrillation and other arrhythmias. The close positioning of the left atria adjacent to the esophagus presents a large risk as the extreme temperatures used during ablation can lead to esophageal damage or fistulas. This device is designed to integrate correlate data from the temperature probe …
Ikioo Flying Robot, Nicholas Michael Lapidus, Bosung Josh Kim, Jenny Fong
Ikioo Flying Robot, Nicholas Michael Lapidus, Bosung Josh Kim, Jenny Fong
Biomedical Engineering
No abstract provided.
Gesea Biosciences - Core Shell Pellet Manufacturing Device, Claire Edelman, Maria Medrano, Rachel Longoria
Gesea Biosciences - Core Shell Pellet Manufacturing Device, Claire Edelman, Maria Medrano, Rachel Longoria
Biomedical Engineering
No abstract provided.
Housecalls Mobile: Virtual Stethoscope/Otoscope, Julia Kelley, Cullen Mcgee, Eduardo Uribe-Saldana
Housecalls Mobile: Virtual Stethoscope/Otoscope, Julia Kelley, Cullen Mcgee, Eduardo Uribe-Saldana
Biomedical Engineering
At the start of the project, our initial deliverables were to add a low cost camera into virtual otoscope and to add a pediatric attachment to the stethoscope. However, about half way through the first quarter (1.5 months into the project), our deliverables changed to the following: to design a housing unit for the selected otoscope camera and to increase battery life to allow for 12+ battery life. To accomplish our deliverables, we divided up the responsibilities as follows: One person headed the mechanical design, one person headed the electrical design, and one person served as a liaison between the …
Pulsed Electrical Field Ablation Modulation, Camille Lousie Dozois, Jason Tyler Arias, Courtnee Lin Madsen
Pulsed Electrical Field Ablation Modulation, Camille Lousie Dozois, Jason Tyler Arias, Courtnee Lin Madsen
Biomedical Engineering
This document comprises the steps taken by the senior project team to create a Proof-of-Concept Review for a Variable Pulsed Electric Field Ablation Catheter. First, the team did a significant amount of background research on related literature to better understand the current status of the project topic. After sufficient background information was obtained, project objectives and deliverables were finalized. Once customer requirements and the indications for use were completed, engineering specifications for the product and project were documented. All key customer requirements and engineering specs were related to the variable pulse functionality, maneuverability, as well as overall dimensioning of the …
Opendrop Software Development, Jiajun Guan
Opendrop Software Development, Jiajun Guan
Electrical Engineering
To be able to transfer and mix solutions more efficiently and accurately during biology experiments, the Electrical Engineering department at Cal Poly University is planning to purchase or engineer the OpenDrop device. The OpenDrop device uses electro-wetting technology to control the movement of small droplets of water on a planar electrode array to transport and mix different solutions. This device is an open-source project and could be purchased online through the GaudiLab. The basic code of the system could be found in GitHub. With this code as a reference, the goal of this senior project is to develop the firmware, …
Knee Joint Biomechanics In Transtibial Amputees In Gait, Cycling, And Elliptical Training, Greg Orekhov, A. Matt Robinson, Scott J. Hazelwood, Stephen M. Klisch
Knee Joint Biomechanics In Transtibial Amputees In Gait, Cycling, And Elliptical Training, Greg Orekhov, A. Matt Robinson, Scott J. Hazelwood, Stephen M. Klisch
Biomedical Engineering
Transtibial amputees may experience decreased quality of life due to increased risk of knee joint osteoarthritis (OA). No prior studies have compared knee joint biomechanics for the same group of transtibial amputees in gait, cycling, and elliptical training. Thus, the goal of this study was to identify preferred exercises for transtibial amputees in the context of reducing risk of knee OA. The hypotheses were: 1) knee biomechanics would differ due to participant status (amputee, control), exercise, and leg type (intact, residual) and 2) gait kinematic parameters would differ due to participant status and leg type. Ten unilateral transtibial amputee and …
Blood Glucose Predictor, Jessica Patterson
Blood Glucose Predictor, Jessica Patterson
Electrical Engineering
For my senior project, I perform data analysis using statistical methods to determine body metrics that correlate with blood glucose levels. Working with Dr. Tina Smilkstein, I take repeat measurements from 6 different volunteers to establish trends in bodily metric data. The data taken includes weight, body fat, pulse rate, VO2, blood glucose, blood pressure, hours slept, and quality of sleep. Using these values, I use the program MiniTab to view results.
A few examples of correlations with blood glucose found in this project are:
- Systolic blood pressure for females had a regression line of 124.0 -0.3366*Blood Pressure. This indicates …
Single-Cell Impedance Spectroscopy, David Paul Lange
Single-Cell Impedance Spectroscopy, David Paul Lange
Master's Theses
Impedance spectroscopy (IS) is an important tool for cell detection and characterization in medical and food safety applications. In this thesis, the Cal Poly Biofluidics Lab’s impedance spectroscopy system was re-evaluated and optimized for single-cell impedance spectroscopy. To evaluate the IS system, an impedance spectroscopy bioMEMS chip was fabricated in the Cal Poly Microfabcrication lab, software was developed to run IS experiments, and studies were run to validate the system. To explore IS optimization, Maxwell’s mixture theorem and the Schwartz-Christoffel transform were used to calculate an analytic impedance solution to the co-planar electrode system,a novel volume fraction to account for …
Customization Of Aneurysm Scaffold Geometries For In Vitro Tissue-Engineered Blood Vessel Mimics To Use As Models For Neurovascular Device Testing, Camille D. Villadolid
Customization Of Aneurysm Scaffold Geometries For In Vitro Tissue-Engineered Blood Vessel Mimics To Use As Models For Neurovascular Device Testing, Camille D. Villadolid
Master's Theses
Cerebral aneurysms occur due to the ballooning of blood vessels in the brain. Rupture of aneurysms can cause a subarachnoid hemorrhage, which, if not fatal, can cause permanent neurologic deficits. Minimally invasive neurovascular devices, such as embolization coils and flow diverters, are methods of treatment utilized to prevent aneurysm rupture. The rapidly growing market for neurovascular devices necessitates the development of accurate aneurysm models for preclinical testing. In vivo models, such as the rabbit elastase model, are commonly chosen for preclinical device testing; however, these studies are expensive, and aneurysm geometries are difficult to control and often do not replicate …
Mechanisms Of Reduced Vascular Tone Following Arteriogenesis Induced By Femoral Artery Ligation, Christopher Hatch
Mechanisms Of Reduced Vascular Tone Following Arteriogenesis Induced By Femoral Artery Ligation, Christopher Hatch
Biomedical Engineering
The presence of a developed, native collateral network can decrease the severity of ischemic injury proceeding arterial occlusion. The collateral network must under arteriogenesis to enlarge and increase blood flow to the ischemic region. Although there has been tremendous effort attempting to understand the mechanisms of arteriogenesis, no therapies have been successful in improving patient outcome. To better understand the mechanisms involved in arteriogenesis, the effect of nitric oxide production, myogenic tone, and a-adrenergic receptors were evaluated as these have been identified as playing an important role in vascular injury. Arteriogenesis was induced by ligating the femoral artery between the …