Open Access. Powered by Scholars. Published by Universities.®

Biomedical Engineering and Bioengineering Commons™

Open Access. Powered by Scholars. Published by Universities.®

Mechanical Engineering

Institution
Keyword
Publication Year
Publication
Publication Type
File Type

Articles 841 - 870 of 1006

Full-Text Articles in Biomedical Engineering and Bioengineering

Multi-Modal, Surface-Focused Anticoagulation Using Poly-2-Methoxyethylacrylate Polymer Grafts And Surface Nitric Oxide Release, Surbhi Gupta, Kagya Amoako, Ahmed Suhaib, Keith E. Cook Nov 2014

Multi-Modal, Surface-Focused Anticoagulation Using Poly-2-Methoxyethylacrylate Polymer Grafts And Surface Nitric Oxide Release, Surbhi Gupta, Kagya Amoako, Ahmed Suhaib, Keith E. Cook

Mechanical and Industrial Engineering Faculty Publications

This study examines platelet adhesion on surfaces that combine coatings to limit protein adsorption along with “anti-platelet” nitric oxide (NO) release. Uncoated and poly-2-methoxyethylacrylate (PMEA) coated, gas permeable polypropylene (PP) membranes were placed in a bioreactor to separate plasma and gas flows. Nitrogen with 100/500/1000 ppm of NO was supplied to the gas side as a proof of concept. On the plasma side, platelet rich plasma (PRP, 1 × 108 cell/mL) was recirculated at low (60)/high (300) flows (mL/min). After 8 hours, adsorbed platelets on PP was quantified via a lactate dehydrogenase assay. Compared to plain PP, the PMEA coating …


Effects Of Hip And Ankle Moments On Running Stability: Simulation Of A Simplified Model, Rubin C. Cholera Oct 2014

Effects Of Hip And Ankle Moments On Running Stability: Simulation Of A Simplified Model, Rubin C. Cholera

Open Access Theses

In human running, the ankle, knee, and hip moments are known to play different roles to influence the dynamics of locomotion. A recent study of hip moments and several hip-based legged robots have revealed that hip actuation can significantly improve the stability of locomotion, whether controlled or uncontrolled. Ankle moments are expected to also significantly affect running stability, but in a different way than hip moments. Here we seek to advance the current theory of dynamic running and associated legged robots by determining how simple open-loop ankle moments could affect running stability. We simulate a dynamical model, and compare it …


Structure-Functionality Relationship Of Collagen Scaffolds For Tissue Engineering, Seungman Park Oct 2014

Structure-Functionality Relationship Of Collagen Scaffolds For Tissue Engineering, Seungman Park

Open Access Dissertations

Tissue engineering is a promising technology that enables scientists to create artificial organs or replace damaged tissues using animal cells and other components. For successful tissue regeneration, many factors should be taken into account, however, three components are most crucial: cell, scaffold, and soluble factor(s). In order to check the functionality after regeneration of desired tissues, various approaches have been attempted, depending on the physical, biological, and chemical properties of the tissues. Recently, the importance of the extracellular matrix (ECM) microstructure is being considered to be important in this regard. The ECM is closely associated with various functional properties of …


Understanding Preferred Leg Stiffness And Layered Control Strategies For Locomotion, Zhuohua H. Shen Oct 2014

Understanding Preferred Leg Stiffness And Layered Control Strategies For Locomotion, Zhuohua H. Shen

Open Access Dissertations

Despite advancement in the field of robotics, current legged robots still cannot achieve the kind of locomotion stability animals and humans have. In order to develop legged robots with greater stability, we need to better understand general locomotion dynamics and control principles. Here we demonstrate that a mathematical modeling approach could greatly enable the discovery and understanding of general locomotion principles. ^ It is found that animal leg stiffness when scaled by its weight and leg length falls in a narrow region between 7 and 27. Rarely in biology does such a universal preference exist. It is not known completely …


Within-Socket Myoelectric Prediction Of Continuous Ankle Kinematics For Control Of A Powered Transtibial Prosthesis, Samuel Farmer, M. Barbara Silver-Thorn, Philip A. Voglewede, Scott A. Beardsley Oct 2014

Within-Socket Myoelectric Prediction Of Continuous Ankle Kinematics For Control Of A Powered Transtibial Prosthesis, Samuel Farmer, M. Barbara Silver-Thorn, Philip A. Voglewede, Scott A. Beardsley

Biomedical Engineering Faculty Research and Publications

Objective. Powered robotic prostheses create a need for natural-feeling user interfaces and robust control schemes. Here, we examined the ability of a nonlinear autoregressive model to continuously map the kinematics of a transtibial prosthesis and electromyographic (EMG) activity recorded within socket to the future estimates of the prosthetic ankle angle in three transtibial amputees. Approach. Model performance was examined across subjects during level treadmill ambulation as a function of the size of the EMG sampling window and the temporal 'prediction' interval between the EMG/kinematic input and the model's estimate of future ankle angle to characterize the trade-off between model error, …


A Collagen‐Glycosaminoglycan‐Fibrin Scaffold For Heart Valve Tissue Engineering Applications, Claire Brougham, Stefan Jockenhoevel, Thomas Flanagan, Fergal O'Brien Sep 2014

A Collagen‐Glycosaminoglycan‐Fibrin Scaffold For Heart Valve Tissue Engineering Applications, Claire Brougham, Stefan Jockenhoevel, Thomas Flanagan, Fergal O'Brien

Conference Papers

The field of heart valve biology and tissue engineering a heart valve continue to expand. The presentatio ns at this meeting reflect the advances made in both areas due to the multi-disciplinary approach taken by many laboratories.


How Sensitive Is The Deltoid Moment Arm To Joint Center Changes With Rtsa?, David Walker, Allison Kinney, Aimee Struk, Benjamin J. Fregly, Thomas Wright, Scott Banks Sep 2014

How Sensitive Is The Deltoid Moment Arm To Joint Center Changes With Rtsa?, David Walker, Allison Kinney, Aimee Struk, Benjamin J. Fregly, Thomas Wright, Scott Banks

Mechanical and Aerospace Engineering Faculty Publications

The goal of this study was to assess the sensitivity of the deltoid muscle moment arms as a function of joint configuration for an existing RTSA subject. High variations were found for all three deltoid components. Variation over the entire abduction arc was greatest in the anterior and lateral deltoid, while the posterior deltoid moment arm was mostly sensitive to joint center changes early in the abduction arc. Moment arm changes of 10-16mm represent a significant amount of the total deltoid moment arm. This means there is an opportunity to dramatically change the deltoid moments arms through surgical placement of …


Deltoid Moment Arms During Abduction: A Subject-Specific Musculoskeletal Modeling Study In Healthy Shoulders And Shoulders With Rtsa, David Walker, Allison Kinney, Aimee Struk, Benjamin J. Fregly, Thomas Wright, Scott Banks Sep 2014

Deltoid Moment Arms During Abduction: A Subject-Specific Musculoskeletal Modeling Study In Healthy Shoulders And Shoulders With Rtsa, David Walker, Allison Kinney, Aimee Struk, Benjamin J. Fregly, Thomas Wright, Scott Banks

Mechanical and Aerospace Engineering Faculty Publications

Reverse total shoulder arthroplasty (RTSA) is increasingly used in the United States since approval by the FDA in 2003. RTSA relieves pain and restores mobility in arthritic rotator cuff deficient shoulders. Though many advantages of RTSA have been demonstrated, there still are a variety of complications (implant loosening, shoulder impingement, infection, frozen shoulder) making apparent much still is to be learned how RTSA modifies normal shoulder function. The goal of this study was to assess how RTSA affects deltoid muscle moment generating capacity post-surgery using a subjectspecific computational model driven by in vivo kinematic data.


A Novel Approach To Estimation Of Patient-Specific Muscle Strength, David Walker, Allison Kinney, Benjamin J. Fregly, Thomas Wright, Scott Banks Sep 2014

A Novel Approach To Estimation Of Patient-Specific Muscle Strength, David Walker, Allison Kinney, Benjamin J. Fregly, Thomas Wright, Scott Banks

Mechanical and Aerospace Engineering Faculty Publications

Current modeling techniques have been used to model the Reverse Total Shoulder Arthroplasty (RTSA) to account for the geometric changes implemented after RTSA. Though these models have provided insight into the effects of geometric changes from RTSA these is still a limitation of understanding muscle function after RTSA on a patient-specific basis. The goal of this study sought to overcome this limitation by developing an approach to calibrate patient-specific muscle strength for an RTSA subject.


Implementation And Validation Of Aortic Remodeling In Hypertensive Rats, Shijia Zhao, Linxia Gu Sep 2014

Implementation And Validation Of Aortic Remodeling In Hypertensive Rats, Shijia Zhao, Linxia Gu

Department of Mechanical and Materials Engineering: Faculty Publications

A computational framework was implemented and validated to better understand the hypertensive artery remodeling in both geometric dimensions and material properties. Integrating the stress-modulated remodeling equations into commercial finite element codes allows a better control and visualization of local mechanical parameters. Both arterial thickening and stiffening effects were captured and visualized. An adaptive material remodeling strategy combined with the element birth and death techniques for the geometrical growth were implemented. The numerically predicted remodeling results in terms of the wall thickness, inner diameter, and the ratio of elastin to collagen content of the artery were compared with and fine-tuned by …


Fluid Powered Miniature In Vivo Robots For Minimally Invasive Surgery (Mis), Abolfazl Pourghodrat Aug 2014

Fluid Powered Miniature In Vivo Robots For Minimally Invasive Surgery (Mis), Abolfazl Pourghodrat

Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research

Minimizing the invasiveness of surgery is believed to improve patient outcomes. Bleeding, infection, and pain are major concerns in surgery afflicting patients for decades. Minimally invasive techniques have come into play to reduce these concerns and smooth the evolution of abdominal surgery to a scarless process where nearly all surgeries can be performed without a skin incision. Technology continually advances the frontier of development of novel surgical devices to implement less invasive surgical techniques.

Fusion of robotics and Minimally Invasive Surgery (MIS) has created new opportunities to develop diagnostic and therapeutic tools. Surgical robotics is advancing from externally actuated systems …


Cfd Simulation Of The Thermal Performance Of A Parallel Counter-Parallel Flow Heat Exchanger For The Treatment Of Hypothermia, Alex Heller Aug 2014

Cfd Simulation Of The Thermal Performance Of A Parallel Counter-Parallel Flow Heat Exchanger For The Treatment Of Hypothermia, Alex Heller

UNLV Theses, Dissertations, Professional Papers, and Capstones

Hypothermia is a life-threatening condition. Currently, active warming methods are the most effective treatment for dysthermic patients. The aim of this study is to investigate the use of computational fluid dynamics (CFD) in evaluating the thermal performance of a parallel/counter-parallel flow heat exchanger used as part of a fluid warmer to treat Hypothermia. The 3D model of the heat exchanger is divided into three regions; Infusate (fluid to be heated), Hot Water (heating fluid), and a Solid Region (wall). At the end of the heat exchanger, an elbow section is used to create the counter-parallel flow arrangement specific to this …


Implementation Of Analytical Fatigue Models Into Opensim To Predict The Effects Of Fatigue On Anterior Cruciate Ligament Loading, Michael A. Samann Jul 2014

Implementation Of Analytical Fatigue Models Into Opensim To Predict The Effects Of Fatigue On Anterior Cruciate Ligament Loading, Michael A. Samann

Mechanical & Aerospace Engineering Theses & Dissertations

The anterior cruciate ligament (ACL) provides stability to the knee joint while performing activities such as a side step cut. Neuromuscular fatigue, a reduction in muscle force producing capabilities, alters lower extremity mechanics while performing a side step cut and may increase the risk of ACL injury, particularly in females. Musculoskeletal modeling allows for the measurement of muscle forces, which are difficult to measure in-vivo. Therefore, musculoskeletal modeling, may improve our understanding of the effects of neuromuscular fatigue on muscle force production and loading of the ACL. Therefore, the purpose of this study was to develop a musculoskeletal model which …


Experimental And Numerical Investigation Of The Mechanism Of Blast Wave Transmission Through A Surrogate Head, Yi Hua, Praveen Akula, Linxia Gu, Jeff Berg, Carl A. Nelson Jul 2014

Experimental And Numerical Investigation Of The Mechanism Of Blast Wave Transmission Through A Surrogate Head, Yi Hua, Praveen Akula, Linxia Gu, Jeff Berg, Carl A. Nelson

Department of Mechanical and Materials Engineering: Faculty Publications

This work is to develop an experiment-validated numerical model to elucidate the wave transmission mechanisms through a surrogate head under blast loading. Repeated shock tube tests were conducted on a surrogate head, i.e., water-filled polycarbonate shell. Surface strain on the skull simulant and pressure inside the brain simulant were recorded at multiple locations. A numerical model was developed to capture the shock wave propagation within the shock tube and the fluid-structure interaction between the shock wave and the surrogate head. The obtained numerical results were compared with the experimental measurements. The experiment-validated numerical model was then used to further understand …


Uncertainty Quantification Driven Predictive Multi-Scale Model For Synthesis Of Mycotoxins, Sourav Banerjee, Gabriel A. Terejanu, Anindya Chanda Jun 2014

Uncertainty Quantification Driven Predictive Multi-Scale Model For Synthesis Of Mycotoxins, Sourav Banerjee, Gabriel A. Terejanu, Anindya Chanda

Faculty Publications

Many toxic molds synthesize and release an array of poisons, termed mycotoxins that have an enormous impact on human health, agriculture and economy [1]. These molds contaminate our buildings, indoor air and crops, cause life threatening human and animal diseases and reduce agricultural output [2]. In order to design appropriate approaches to minimize the detrimental effects of these fungi, it is essential to develop diagnostic methodologies that can rapidly and accurately determine based on fungal strains and their growth patterns, the extent of mycotoxin mediated damage caused to the environment.Here we developed a novel multi-scale predictive mathematical model that could …


2d Wireform Process Improvement, Katy Conlin, Carlo Ebora, Jordan Gamble Jun 2014

2d Wireform Process Improvement, Katy Conlin, Carlo Ebora, Jordan Gamble

Mechanical Engineering

The body of this work has been created for Edwards Lifesciences in conjunction with senior project requirements. As such, the information produced and contained within is under a non‐disclosure agreement. As per request by sponsor, the body of the work will not be submitted to any outside parties, and the title page will serve as proof of completion.


Fluid Flow-Induced Mesenchymal Stem Cell Migration: Role Of Fak And Rock Mechanosensors, Brandon D. Riehl May 2014

Fluid Flow-Induced Mesenchymal Stem Cell Migration: Role Of Fak And Rock Mechanosensors, Brandon D. Riehl

Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research

The study of mesenchymal stem cell (MSC) migration under mechanical stimulation conditions with investigation of the underlying molecular mechanism could lead to a better understanding and outcomes in stem cell-based regenerative medicine. MSCs having multipotent regenerative capability exist in niches in the bone marrow, muscle, vasculature, and in other tissues throughout the body, and their migration through tissues and vasculature for the repair of damaged tissue is a key process of cell and tissue homeostasis, remodeling, and regeneration. While cell migration in response to cytokines and other chemo-attractants is relatively well understood, little is revealed in regard to the effect …


Application Of Limited Mixing In The Hele–Shaw Geometry In Fabrication Of Janus Hydrogels, Md Mahmudur Rahman Apr 2014

Application Of Limited Mixing In The Hele–Shaw Geometry In Fabrication Of Janus Hydrogels, Md Mahmudur Rahman

Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research

It is widely accepted that cells behave differently responding to the stiffness of their extracellular matrix (ECM). Such observations were made by culturing cells on hydrogel substrates of tunable stiffness. However, it was recently proposed that cells may sense how strongly they are tethered to ECM, not the local stiffness of ECM. To investigate both hypotheses, we developed a method to fabricate Janus polyacrylamide (PAAM) gels. We squeeze two drops of different concentrations in the Hele-Shaw geometry to generate radial Stokes flow. When the drops coalesce, limited mixing occurs at the interface due to the narrow confinement, and diffusion normal …


Subtalar Fusion Fixture Design And Test, Nathan Ortiz Apr 2014

Subtalar Fusion Fixture Design And Test, Nathan Ortiz

Honors Theses

Subtalar arthrodesis is performed when cartilage in the talo-calcaneal (the ankle) joint is degraded in a patient and there are multiple approaches to this surgery. Using synthetic bone material, fixtures were cast from aluminum, using the process of evaporation pattern casting, and epoxy. This casting was used to grip the calcaneus bone of the foot in order to load it mechanically, simulating different scenarios that would be encountered during walking. The relative displacement of the ankle joint was measured using a digital image correlation (DIC) program that was modified to work in both two- and three-dimensional space. This program can …


Hand Prosthesis, Tru Nguyen, Aaron Delano, Kyle M. Green, Jorge Maderal, Cody Poland Apr 2014

Hand Prosthesis, Tru Nguyen, Aaron Delano, Kyle M. Green, Jorge Maderal, Cody Poland

Thinking Matters Symposium Archive

This project deals with engineering students’ prosthetic hand design, submitted to the University of Southern Maine’s engineering department. The primary goal of the prosthetic hand design is to allow an impaired individual to grasp and hold everyday objects ranging from a toothbrush to a jug of milk. The project consists of three teams each designing their respective portion of the prosthetic device. The teams will deal with three specific design areas; computer aided design of the mechanism, electronic integration, and manufacturing implementation. The design team turns notebook doodles into virtual models in SolidWorks. The electronics team will control a battery …


Characterizing Phantom Arteries With Multi-Channel Laser Ultrasonics And Photo-Acoustics, Jami L. Johnson, Kasper Van Wijk, Michelle Sabick Mar 2014

Characterizing Phantom Arteries With Multi-Channel Laser Ultrasonics And Photo-Acoustics, Jami L. Johnson, Kasper Van Wijk, Michelle Sabick

Mechanical and Biomedical Engineering Faculty Publications and Presentations

Multi-channel photo-acoustic and laser ultrasonic waves are used to sense the characteristics of proxies for healthy and diseased vessels. The acquisition system is non-contacting and non-invasive with a pulsed laser source and a laser vibrometer detector. As the wave signatures of our targets are typically low in amplitude, we exploit multi-channel acquisition and processing techniques. These are commonly used in seismology to improve the signal-to-noise ratio of data. We identify vessel proxies with a diameter on the order of 1 mm, at a depth of 18 mm. Variations in scattered and photo-acoustic signatures are related to differences in vessel wall …


Hemocompatibility Comparison Of Biomedical Grade Polymers Using Rabbit Thrombogenicity Model For Preparing Nonthrombogenic Nitric Oxide Releasing Surfaces, Hitesh Handa, Terry C. Major, Elizabeth Brisbois, Kagya Amoako, Mark E. Meyerhoff, Robert E. Bartlett Feb 2014

Hemocompatibility Comparison Of Biomedical Grade Polymers Using Rabbit Thrombogenicity Model For Preparing Nonthrombogenic Nitric Oxide Releasing Surfaces, Hitesh Handa, Terry C. Major, Elizabeth Brisbois, Kagya Amoako, Mark E. Meyerhoff, Robert E. Bartlett

Mechanical and Industrial Engineering Faculty Publications

Nitric oxide (NO) is an endogenous vasodilator as well as natural inhibitor of platelet adhesion/ activation. Nitric oxide releasing (NOrel) materials can be prepared by doping an NO donor species, such as diazeniumdiolated dibutylhexanediamine (DBHD/N2O2), within a polymer coating. The inherent hemocompatibility properties of the base polymer can also influence the efficiency of such NO release coatings. In this study, four biomedical grade polymers were evaluated in a 4 h rabbit model of thrombogenicity for their effects on extracorporeal circuit thrombus formation and circulating platelet count. At the end of 4 h, Elast-Eon E2As was found to preserve 58% of …


Quantification Of Transhumeral Prosthetic Socket Residual Limb Interface Movement Using Motion Capture And A Slip Detection Sensor, Matthew Wernke Jan 2014

Quantification Of Transhumeral Prosthetic Socket Residual Limb Interface Movement Using Motion Capture And A Slip Detection Sensor, Matthew Wernke

USF Tampa Graduate Theses and Dissertations

Current literature focusing on the prosthetic socket is limited by measurement techniques and modeling assumptions, leading to a limited understanding of the forces and motions occurring between the residual limb and prosthesis and how they can be used to influence socket design and fitting. Prosthetic socket fitting and prescription would benefit from an elegant method for comparing socket designs. This dissertation focuses on the development and implementation of a 3D motion capture model and a Slip Detection Sensor to quantify rotations and translations at the prosthetic socket-residual limb interface. The 3D motion capture model defines the residual limb bone position …


Heavy Element Doping For Enhancing Thermoelectric Properties Of Nanostructured Zinc Oxide, Priyanka Jood, Rutvik J. Mehta, Yanliang Zhang, Theo Borca-Tasciuc, Shi Xue Dou, David J. Singh, Ganpati Ramanath Jan 2014

Heavy Element Doping For Enhancing Thermoelectric Properties Of Nanostructured Zinc Oxide, Priyanka Jood, Rutvik J. Mehta, Yanliang Zhang, Theo Borca-Tasciuc, Shi Xue Dou, David J. Singh, Ganpati Ramanath

Mechanical and Biomedical Engineering Faculty Publications and Presentations

ZnO is a high melting point, high charge carrier mobility semiconductor with potential as a thermoelectric material, but its high thermal conductivity κ is the limiting factor for increasing the thermoelectric figure of merit ZT. Here, we demonstrate that doping ZnO with heavy elements can significantly enhance ZT. Indium doping leads to ultralow κ 3 W m−1 K−1 and a high power factor α2σ 1.230 × 10−3 W m−1 K−2, yielding ZT1000K 0.45 that is 80% higher than non-nanostructured In–Zn–O alloys. Although Bi doping also yields a high Seebeck coefficient of …


Electromyogram Synergy Control Of A Dexterous Artificial Hand To Unscrew And Screw Objects, Benjamin A. Kent, Nareen Karnati, Erik D. Engeberg Jan 2014

Electromyogram Synergy Control Of A Dexterous Artificial Hand To Unscrew And Screw Objects, Benjamin A. Kent, Nareen Karnati, Erik D. Engeberg

Mechanical Engineering Faculty Research

Due to their limited dexterity, it is currently not possible to use a commercially available prosthetic hand to unscrew or screw objects without using elbow and shoulder movements. For these tasks, prosthetic hands function like a wrench, which is unnatural and limits their use in tight working environments. Results from timed rotational tasks with human subjects demonstrate the clinical need for increased dexterity of prosthetic hands, and a clinically viable solution to this problem is presented for an anthropomorphic artificial hand.


Biomechanical Performance Of Variable And Fixed Angle Locked Volar Plates For The Dorsally Comminuted Distal Radius, Patrick Atkinson, D. Martineau, J. Shorez, C. Beran, A. G. Dass Jan 2014

Biomechanical Performance Of Variable And Fixed Angle Locked Volar Plates For The Dorsally Comminuted Distal Radius, Patrick Atkinson, D. Martineau, J. Shorez, C. Beran, A. G. Dass

Mechanical Engineering Publications

Background

The ideal treatment strategy for the dorsally comminuted distal radius fracture continues to evolve. Newer plate designs allow for variable axis screw placement while maintaining the advantages of locked technology. The purpose of this study is to compare the biomechanical properties of one variable axis plate with two traditional locked constructs.

Methods

Simulated fractures were created via a distal 1 cm dorsal wedge osteotomy in radius bone analogs. The analogs were of low stiffness and rigidity to create a worst-case strength condition for the subject radius plates. This fracture-gap model was fixated using one of three different locked volar …


A Backing Device Based On An Embedded Stiffener And Retractable Insertion Tool For Thin-Film Cochlear Arrays, Radheshyam Tewari Jan 2014

A Backing Device Based On An Embedded Stiffener And Retractable Insertion Tool For Thin-Film Cochlear Arrays, Radheshyam Tewari

Dissertations, Master's Theses and Master's Reports - Open

Intracochlear trauma from surgical insertion of bulky electrode arrays and inadequate pitch perception are areas of concern with current hand-assembled commercial cochlear implants. Parylene thin-film arrays with higher electrode densities and lower profiles are a potential solution, but lack rigidity and hence depend on manually fabricated permanently attached polyethylene terephthalate (PET) tubing based bulky backing devices. As a solution, we investigated a new backing device with two sub-systems. The first sub-system is a thin poly(lactic acid) (PLA) stiffener that will be embedded in the parylene array. The second sub-system is an attaching and detaching mechanism, utilizing a poly(N-vinylpyrrolidone)-block-poly(d,l-lactide) (PVP-b-PDLLA) copolymer-based …


High-Performance Accelerometer Based On Asymmetric Gapped Cantilevers For Physiological Acoustic Sensing, Yating Hu Jan 2014

High-Performance Accelerometer Based On Asymmetric Gapped Cantilevers For Physiological Acoustic Sensing, Yating Hu

Wayne State University Dissertations

Continuous or mobile monitoring of physiological sounds is expected to play important role in the emerging mobile healthcare field. Because of the miniature size, low cost, and easy installation, accelerometer is an excellent choice for continuous physiological acoustic signal monitoring. However, in order to capture the detailed information in the physiological signals for clinical diagnostic purpose, there are more demanding requirements on the sensitivity/noise performance of accelerometers. In this thesis, a unique piezoelectric accelerometer based on the asymmetric gapped cantilever which exhibits significantly improved sensitivity is extensively studied. A meso-scale prototype is developed for capturing the high quality cardio and …


Analysis And Modeling Of The Roles Of Actin-Myosin Interactions In Bladder Smooth Muscle Biomechanics, Seyed Omid Komariza Jan 2014

Analysis And Modeling Of The Roles Of Actin-Myosin Interactions In Bladder Smooth Muscle Biomechanics, Seyed Omid Komariza

Theses and Dissertations

Muscle mechanical behavior potentially plays an important role in some of the most common bladder disorders. These include overactive bladder, which can involve involuntary contractions during bladder filling, and impaired contractility or underactive bladder, which may involve weak or incomplete contractions during voiding. Actin-myosin cross-bridges in detrusor smooth muscle (DSM) are responsible for contracting and emptying the bladder. The total tension produced by muscle is the sum of its preload and active tensions. Studies suggest that actin-myosin cross-links are involved in adjustable preload stiffness (APS), which is characterized by a preload tension curve that can be shifted along the length …


Applying Spiking Neural Network Simulation To Neuromodulatory Autonomous Robot Control, Cameron Muhammad Jan 2014

Applying Spiking Neural Network Simulation To Neuromodulatory Autonomous Robot Control, Cameron Muhammad

Phi Kappa Phi Research Symposium (Archived)

In this paper, simulation of the brain based on an artificial spiking neuron model is used to create a self-learning algorithm. The spiking neuron simulation is used to demonstrate a neuromodulation program in which the reward seeking properties of dopamine, the risk-adverse effects of serotonin, and the attention-focusing effects of the cholinergic and noradrenergic systems are applied to a mobile robotic platform as it moves autonomously throughout an environment. External stimuli is recorded by the program as spiking “events” that result in corresponding amounts of dopamine and serotonin influenced spiking patterns. These spiking patterns affect how the robot adapts to …