Open Access. Powered by Scholars. Published by Universities.®
Biomedical Engineering and Bioengineering Commons™
Open Access. Powered by Scholars. Published by Universities.®
- Institution
-
- California Polytechnic State University, San Luis Obispo (213)
- Missouri University of Science and Technology (131)
- University of Arkansas, Fayetteville (70)
- The University of Akron (48)
- University of Nebraska - Lincoln (45)
-
- Purdue University (39)
- University of Nevada, Las Vegas (32)
- Technological University Dublin (27)
- Marquette University (26)
- City University of New York (CUNY) (25)
- Dartmouth College (25)
- University of Kentucky (25)
- Old Dominion University (24)
- Virginia Commonwealth University (22)
- University of Louisville (21)
- Clemson University (20)
- University of Mississippi (19)
- University of Connecticut (17)
- Kettering University (16)
- Michigan Technological University (15)
- University of Denver (14)
- University of Malaya (12)
- Brigham Young University (11)
- West Virginia University (11)
- Louisiana State University (10)
- Washington University in St. Louis (10)
- Duquesne University (9)
- Embry-Riddle Aeronautical University (9)
- Cleveland State University (7)
- Georgia Southern University (7)
- Keyword
-
- Microfluidics (34)
- Biomechanics (14)
- Biomedical Engineering (14)
- Biomedical (13)
- Biomedical engineering (13)
-
- Daniel Felix Ritchie School of Engineering and Computer Science (13)
- Machine learning (12)
- Prosthetic (12)
- Cancer (11)
- Device (11)
- Engineering (11)
- Machine Learning (11)
- Prosthetics (11)
- Medical device (10)
- Surgery (10)
- Biomaterials (9)
- Electrophysiology (9)
- Kinematics (9)
- 3D printing (8)
- Applied sciences (8)
- Biosensor (8)
- Diagnostics (8)
- Gait (8)
- Mechanical and Materials Engineering (8)
- Sensor (8)
- Ultrasound (8)
- Wearable (8)
- Arduino (7)
- Bone (7)
- Breast cancer (7)
- Publication Year
- Publication
-
- Chemical and Biochemical Engineering Faculty Research & Creative Works (131)
- Master's Theses (98)
- Biomedical Engineering (79)
- Williams Honors College, Honors Research Projects (47)
- Electronic Theses and Dissertations (42)
-
- Graduate Theses and Dissertations (32)
- The Summer Undergraduate Research Fellowship (SURF) Symposium (30)
- UNLV Theses, Dissertations, Professional Papers, and Capstones (28)
- Biomedical Engineering Undergraduate Honors Theses (26)
- Theses and Dissertations (25)
- Honors Theses (22)
- Mechanical Engineering (22)
- Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research (17)
- Master's Theses (2009 -) (17)
- Theses and Dissertations--Biomedical Engineering (17)
- Conference Papers (16)
- Dissertations, Master's Theses and Master's Reports (15)
- Dissertations and Theses (12)
- Student Works (2020-2029) (12)
- All Dissertations (11)
- Dartmouth College Ph.D Dissertations (11)
- Graduate Theses, Dissertations, and Problem Reports (ETD) (11)
- Mechanical Engineering Patents (11)
- Biomedical Engineering Western Regional Conference (10)
- McKelvey School of Engineering Graduate Student Theses & Dissertations (10)
- Publications and Research (10)
- All Theses (9)
- Dissertations (1934 -) (9)
- Honors Scholar Theses (8)
- Department of Agricultural and Biological Systems Engineering: Dissertations, Theses, and Student Research (7)
- Publication Type
- File Type
Articles 961 - 990 of 1153
Full-Text Articles in Biomedical Engineering and Bioengineering
Aluminium-Free Glass Polyalkenoate Cements: Ion Release And In Vitro Antibacterial Efficacy, A. W. Wren, J. P. Hansen, S. Hayakawa, Mark R. Towler
Aluminium-Free Glass Polyalkenoate Cements: Ion Release And In Vitro Antibacterial Efficacy, A. W. Wren, J. P. Hansen, S. Hayakawa, Mark R. Towler
Chemical and Biochemical Engineering Faculty Research & Creative Works
Glass polyalkenoate cements (GPCs) have exhibited potential as bone cements. This study investigates the effect of substituting TiO2 for SiO2 in the glass phase and the subsequent effect on cement rheology, mechanical properties, ion release and antibacterial properties. Glass characterization revealed a reduction in glass transition temperature (Tg) from 685 to 669 C with the addition of 6 mol % TiO2 (AT-2). Magic angle spinning nuclear magnetic resonance (MAS-NMR) revealed a shift from -81 ppm to -76pmm when comparing a Control glass to AT-2, indicating de-polymerization of the Si network. The incorporation of TiO2 …
Design And Implementation Of Wireless Point-Of-Care Health Monitoring Systems: Diagnosis For Sleep Disorders And Cardiovascular Diseases, Se Chang Oh
Graduate Theses and Dissertations
Chronic sleep disorders are present in 40 million people in the United States. More than 25 million people remain undiagnosed and untreated, which accounts for over $22 billion in unnecessary healthcare costs. In addition, another major chronic disease is the heart diseases which cause 23.8% of the deaths in the United States. Thus, there is a need for a low cost, reliable, and ubiquitous patient monitoring system. A remote point-of-care system can satisfy this need by providing real time monitoring of the patient's health condition at remote places. However, the currently available POC systems have some drawbacks; the fixed number …
Novel Approach To Junctional Bleeding: Tourniquet Device Proposal For Battlefield Hemorrhage Control, Kyle W. Cabaniss
Novel Approach To Junctional Bleeding: Tourniquet Device Proposal For Battlefield Hemorrhage Control, Kyle W. Cabaniss
Master's Theses
This study investigated possible solutions to the current wartime problem of junctional hemorrhaging, or massive traumatic hemorrhaging in non-tourinquetable areas such as the neck, groin, or armpit. Junctional hemorrhaging has been identified as a major contributor to potentially survivable deaths seen on the battlefield today and therefore is a priority for the U.S. armed and coalition forces (Kragh et al., 2011a; Bozeman, 2011). Common tourniquets today are standard issue and carried by soldiers in the military, but are limited to distal extremity trauma. As the battlefield has changes however, trauma has transformed from commonly seen gunshot wounds to more extreme …
A Microfluidic Pretreatment Isoelectric Focusing Dc-Field Assisted H-Filter For The Separation Of Charged Particles, Cameron Sean Carroll
A Microfluidic Pretreatment Isoelectric Focusing Dc-Field Assisted H-Filter For The Separation Of Charged Particles, Cameron Sean Carroll
Biomedical Engineering
Microfluidic devices are small portable diagnostic chips that allow for analysis of a biologic sample at relatively low cost. This makes them ideal for settings where a hospital is unavailable. The microfluidic pretreatment isoelectric focusing DC-field assisted H-filter is a device that allows for the separation of differently charged particles in a biologic sample. It does this by employing the concepts of diffusion, electrophoresis, and isoelectric focusing. This is perfect for isolation of a desired analyte or separation of waste from a sample in order to achieve better diagnostic results. The device was first modeled mathematically and visually using Comsol. …
Comparison Of A Sio2-Cao-Zno-Sro Glass Polyalkenoate Cement To Commercial Dental Materials: Glass Structure And Physical Properties, A. W. Wren, A. Coughlan, F. R. Laffir, Mark R. Towler
Comparison Of A Sio2-Cao-Zno-Sro Glass Polyalkenoate Cement To Commercial Dental Materials: Glass Structure And Physical Properties, A. W. Wren, A. Coughlan, F. R. Laffir, Mark R. Towler
Chemical and Biochemical Engineering Faculty Research & Creative Works
Glass polyalkenoate cements (GPCs) have previously been considered for orthopedic applications. A Zn-GPC (BT 101) was compared to commercial GPCs (Fuji IX and Ketac Molar) which have a setting chemistry analogous to BT 101. Handling properties (working, Tw and setting, Ts times) for BT 101 were shorter than the commercial GPCs. BT 101 also had a higher setting exotherm (Sx - 34 °C) than the commercial GPCs (29 °C). The maximum strengths for BT 101, Fuji IX, and Ketac Molar were 75, 238, and 216 MPa (compressive, σc), and 34, 54, and 62 MPa (biaxial …
Easily Implantable And Stable Nail-Fastener For Skeletal Fixation And Method, Patrick Atkinson, David Lecronier
Easily Implantable And Stable Nail-Fastener For Skeletal Fixation And Method, Patrick Atkinson, David Lecronier
Mechanical Engineering Patents
An intramedullary nail (20) defining a bore (34) is inserted into a medullary canal (26) of a bone (24). A threaded fastener (22) has a compression portion (48) presenting a compression portion diameter (D) and a threaded portion (50) present ing a threaded portion diameter (D). The fastener (22) extends through a near cortex hole (40) and/or a far cortex hole (42), and the threaded portion (22) threadedly engages the bore (34). A compression transmission device (54) is disposed between a head (44) of the fastener (22) and the intramedullary nail (20) for transmitting the compressional load of the threaded …
Automated Point-Of-Care Image Processing Methodology For The Diagnosis Of Malaria, Michael B. Jorgensen
Automated Point-Of-Care Image Processing Methodology For The Diagnosis Of Malaria, Michael B. Jorgensen
Master's Theses
Malaria has profoundly influenced human history for over four thousand years and despite numerous attempts at eradication, the prevention, diagnosis, and treatment of malaria have been largely ineffective. More than five hundred million people are affected by malaria every year resulting in over one million deaths. Drug resistance development by the parasite has diminished the effectiveness of numerous treatment options due, in part, to overtreatment of negative patients based on insufficient clinical algorithms and diagnostic methods. The goal of this research was to develop an image analysis algorithm to diagnose malaria with a high degree of sensitivity and specificity in …
Modeling Hrtf For Sound Localization In Normal Listeners And Bilateral Cochlear Implant Users, Douglas A. Miller
Modeling Hrtf For Sound Localization In Normal Listeners And Bilateral Cochlear Implant Users, Douglas A. Miller
Electronic Theses and Dissertations
Mathematical models can be very useful for understanding complicated systems and for testing algorithms through simulation that would be difficult or expensive to implement. This dissertation presents a model that attempts to simulate the sound localization performance of persons using bilateral cochlear implants. The expectation is that this model could prove to be a useful tool in developing new signal processing algorithms for neural encoding strategies.
The head related transfer function (HRTF) is a critical component of this model, and in the ideal case, provides the base characteristics of head shadow, torso and pinna effects. This defines the temporal, intensity …
Diagnosis Of Systemic Inflammation Using Transendothelial Electrical Resistance And Low-Temperature Co-Fired Ceramic Materials, William L. Mercke
Diagnosis Of Systemic Inflammation Using Transendothelial Electrical Resistance And Low-Temperature Co-Fired Ceramic Materials, William L. Mercke
Theses and Dissertations--Chemical and Materials Engineering
Systemic inflammation involves a complex array of cytokines that can result in organ dysfunction. Mortality remains high despite the vast amount of research conducted to find an effective biomarker. The cause of systemic inflammation can be broad and non-specific; therefore, this research investigates using transendothelial electrical resistance (TEER) measurements to better define systemic inflammatory response syndrome (SIRS)/sepsis within a patient. Results show a difference in TEER measurements between healthy individuals and SIRS-rated patients. This research also displays correlations between TEER measurements and biomarkers currently studied with systemic inflammation (tumor necrosis factor-α, C- reactive protein, procalcitonin). Furthermore, this research also presents …
Independent Component Analysis Enhancements For Source Separation In Immersive Audio Environments, Yue Zhao
Independent Component Analysis Enhancements For Source Separation In Immersive Audio Environments, Yue Zhao
Theses and Dissertations--Electrical and Computer Engineering
In immersive audio environments with distributed microphones, Independent Component Analysis (ICA) can be applied to uncover signals from a mixture of other signals and noise, such as in a cocktail party recording. ICA algorithms have been developed for instantaneous source mixtures and convolutional source mixtures. While ICA for instantaneous mixtures works when no delays exist between the signals in each mixture, distributed microphone recordings typically result various delays of the signals over the recorded channels. The convolutive ICA algorithm should account for delays; however, it requires many parameters to be set and often has stability issues. This thesis introduces the …
Biomechanical Comparison Of Lower Limb Unloading Between Common Modalities Of Ankle Foot Orthoses, Andrea Blake Wanamaker
Biomechanical Comparison Of Lower Limb Unloading Between Common Modalities Of Ankle Foot Orthoses, Andrea Blake Wanamaker
Electronic Theses and Dissertations
Tibial stress fractures and other lower extremity injuries can be treated using an ankle foot orthosis (AFO). AFOs are popular because they allow the patient to ambulate somewhat naturally while reducing weight bearing on the injured limb. Despite their popularity, it is currently unclear how well AFOs reduce lower extremity weight bearing.
The first objective of this investigation was to examine the ability of three commonly used ankle foot orthoses to reduce weight bearing within the lower limb by comparing the ground reaction force measured from a force platform to the force measured from an insole pressure measurement device inside …
Computational Representation Of The Patellofemoral Joint, Abraham Wright
Computational Representation Of The Patellofemoral Joint, Abraham Wright
Electronic Theses and Dissertations
Many people suffer from knee pain due to abnormal function of the patellofemoral joint and are not able to enjoy normal activities of daily living. Surgical treatments are available and new methods are being developed by the medical industry. However, computational tools to efficiently evaluate the effects of the intervention on patellofemoral function are lacking.
Therefore, a validated and efficient computational model of the patellofemoral joint was developed. The subject specific finite element model was validated against the patellar kinematics recorded during cadaveric patellofemoral laxity experiments of the natural knee. The development involved a sequential process in which the soft-tissue …
Measuring Impedance Of Tissues Using A Microfabricated Microelectrode Array, Ashwini Bhat
Measuring Impedance Of Tissues Using A Microfabricated Microelectrode Array, Ashwini Bhat
Master's Theses
MEASURING IMPEDANCE OF TISSUES USING A MICROFABRICATED MICROELECTRODE ARRAY By Ashwini Bhat
This thesis looks at the possibility of using impedance spectroscopy for differentiating tissue, using a microelectrode array (MEA). The thesis first discusses the background and the motivation for this thesis. It covers the certain basic concepts of the human skin starting from the top epidermis layer all the way to the deep dermis layers of the skin. Then it discusses different types of skin cancer and how they occur, in humans. It also discusses various microfabrication techniques such as oxidation, wet etching, sputtering and photolithography for the creation …
On The Importance Of Modeling Stent Procedure For Predicting Arterial Mechanics, Shijia Zhao, Linxia Gu, Stacey R. Froemming
On The Importance Of Modeling Stent Procedure For Predicting Arterial Mechanics, Shijia Zhao, Linxia Gu, Stacey R. Froemming
Department of Mechanical and Materials Engineering: Faculty Publications
The stent-artery interactions have been increasingly studied using the finite element method for better understanding of the biomechanical environment changes on the artery and its implications. However, the deployment of balloon-expandable stents was generally simplified without considering the balloon-stent interactions, the initial crimping process of the stent, its overexpansion routinely used in the clinical practice, or its recoil process. In this work, the stenting procedure was mimicked by incorporating all the above-mentioned simplifications. The impact of various simplifications on the stent-induced arterial stresses was systematically investigated. The plastic strain history of stent and its resulted geometrical variations, as well as …
Morphometric, Biochemical, And Raman Spctral Analyses Of Muscle Damage In Patients With Peripheral Arterial Disease: Provising Objective Criteria For Diagnosis And Treatment Monitoring, Kim Cluff
Department of Agricultural and Biological Systems Engineering: Dissertations, Theses, and Student Research
Peripheral arterial disease (PAD), which affects approximately 10 million Americans, is characterized by atherosclerosis of the non-coronary arteries. PAD produces a progressive accumulation of ischemic injury to the limbs that is reflected in a gradual worsening in the myofiber morphology and oxidative damage in the gastrocnemius muscle. In this study, we evaluated the hypothesis that quantitative morphological and biochemical parameters of gastrocnemius myofibers change in a consistent manner during the progression of PAD, provide an objective grading of muscle degeneration in the ischemic limb, and correlate to clinical stage of PAD. Myofiber morphometrics were determined precisely with mathematical equations that …
Handitrike - Recumbent Tricycle, Sean Higginson, Kevin Howie, Vinay Patel
Handitrike - Recumbent Tricycle, Sean Higginson, Kevin Howie, Vinay Patel
Mechanical Engineering
This report covers the design and construction of the recumbent racing tricycle for Mr. Robert T. Kelly, a disabled veteran. Unfortunately Rob’s right leg is five inches shorter than his left one and therefore is unable to properly operate standard cranks. Our team HandiTrike is composed of Sean Higginson, Kevin Howie, and Vinay Patel and our project requires us to come up with a design that is feasible to complete within the given three quarters, as well as allow Rob to gain full use of his tricycle. Currently Rob ‘s trike uses the standard crank set up found on most …
Fabrication Of Cao-Nao-Sio2/Tio2 Scaffolds For Surgical Applications, A. W. Wren, A. Coughlan, K. E. Smale, S. T. Misture, B. P. Mahon, O. M. Clarkin, Mark R. Towler
Fabrication Of Cao-Nao-Sio2/Tio2 Scaffolds For Surgical Applications, A. W. Wren, A. Coughlan, K. E. Smale, S. T. Misture, B. P. Mahon, O. M. Clarkin, Mark R. Towler
Chemical and Biochemical Engineering Faculty Research & Creative Works
A series of titanium (Ti) based glasses were formulated (0.62 SiO2-0.14 Na2O-0.24 CaO, with 0.05 mol% TiO2 substitutions for SiO2) to develop glass/ceramic scaffolds for bone augmentation. Glasses were initially characterised using X-ray diffraction (XRD) and particle size analysis, where the starting materials were amorphous with 4.5 μm particles. Hot stage microscopy and high temperature XRD were used to determine the sintering temperature (̃700 °C) and any crystalline phases present in this region (Na2Ca3Si6O16, combeite and quartz). Hardness testing revealed that the Ti-free control (ScC- …
Development Of Simulation Platform For Oropharyngeal Airway Placement And Design Evaluation Of The Bardo Airway, Lewis On Hang Lee
Development Of Simulation Platform For Oropharyngeal Airway Placement And Design Evaluation Of The Bardo Airway, Lewis On Hang Lee
Master's Theses
Off-label use of traditional Oropharyngeal Airway (OPA) as a bite-block, and the subsequential procedure of force exertion of the device by physician has caused many cases of patient’s teeth damage and monetary loss, as the patient’s incisors were damaged while clenching on the OPA during an adverse scenario called “Emergency Clenching”. To remedy this harmful situation, Bardo OPA was developed by Dr. Theodore Burdumy. The Bardo airway has unique design to transfer the clenching force from incisor to the molar. However, the Bardo OPA is one-sized, and cannot fit most of the patients like the commonly-used OPAs, such as the …
Compression Transmission Collar For Fastening, Patrick Atkinson
Compression Transmission Collar For Fastening, Patrick Atkinson
Mechanical Engineering Patents
A compression transmission collar apparatus (20) for implantation into a bone (22) with a hole (28) having a hole wall (32) comprising an intramedullary nail (34) defining a bore (40) and a threaded fastener (42) and a compression transmission collar (58) including an exterior face (64) and a top edge (60) and a bottom edge (62) and a first end (70) intersecting the top edge (60) at an acute angle (α1) and …
Easily Implantable And Stable Nail-Fastener For Skeletal Fixation And Method, Patrick Atkinson, David Lecronier
Easily Implantable And Stable Nail-Fastener For Skeletal Fixation And Method, Patrick Atkinson, David Lecronier
Mechanical Engineering Patents
An intramedullary nail (20) for insertion into the medullary canal (26) in a bone (24) surrounded by the cortex (28) and defines a bore (34) extending transverse to the intramedullary nail (20). A threaded fastener (22) extends along a fastener axis (A) and has a compression portion (48) having a compression portion diameter (DCP), and a threaded portion (50) having a threaded portion diameter (DTP) extending through a near cortex hole (40) and a far cortex hole (42), both holes (40, 42) radially overlapping the bore (34) and the threaded portion diameter (DTP) threadedly engaging the bore (34). A compression …
Method And Apparatus For Utilizing Amplitude-Modulated Pulse-Width Modulation Signals For Neurostimulation And Treatment Of Neurological Disorders Using Electrical Stimulation, Jeffrey Hargrove, Theodore Stokes, Mary L. Esty
Method And Apparatus For Utilizing Amplitude-Modulated Pulse-Width Modulation Signals For Neurostimulation And Treatment Of Neurological Disorders Using Electrical Stimulation, Jeffrey Hargrove, Theodore Stokes, Mary L. Esty
Mechanical Engineering Patents
A computing device-controlled system is described for the generation of amplitude-modulated pulse-width modulation (AMPWM) signals for use in treating neurological dysfunction via cranial neurostimulation, where the AMPWM signal is specifically designed to minimize the electrical impedance of the tissues of the head. A low-frequency carrier signal is determined for the AMPWM signal by measuring EEG activity at a reference site or sites, generally corresponding with the location of suspected brain dysfunction. Carrier signal frequency is variably related to critical frequency components of the EEG power spectral density, determined from statistical analysis of amplitudes and variability, and dynamically changed as a …
A Low Cost Motion Analysis System Based On Kinect, Jonathan Michael Cardinale, Tracy N. Jennemann, Vitaliy Sinyuk, Sam Kenji Yokoyama
A Low Cost Motion Analysis System Based On Kinect, Jonathan Michael Cardinale, Tracy N. Jennemann, Vitaliy Sinyuk, Sam Kenji Yokoyama
Undergraduate Research Posters 2012
The project focused on the validation of using the Kinect sensor to build a low cost motion analysis system for physical therapy and rehabilitation, and the identification of the types of the motions that cannot be captured well by the Kinect sensor and are in need of inertial sensors.
Hydrodynamic Focused Passive Separation Under Continuous Flow In A Microfluidic Chip, Jad Kanbar
Hydrodynamic Focused Passive Separation Under Continuous Flow In A Microfluidic Chip, Jad Kanbar
Master's Theses
A continuous flow, passive separation device was designed using an equivalent circuit to create variable flow rates for hydrodynamic focusing to drain channels and collection outlets. By varying the diameter of the sample inlet connection into the reservoir, the particle position was influenced significantly, which enabled desired separations. Additionally it was noted that the relative, horizontal position of the inlet also had a significant influence on particle position within the device. A dimensionless number, the Characteristic Sample Inlet, was developed to relate geometric properties of the inlet reservoir to downstream particle distribution. It was found that a 2:1 ratio between …
Responding To Dangerous Accidents Among The Elderly: A Fall Detection Device With Zigbee-Based Positioning, Michael R. Putnam
Responding To Dangerous Accidents Among The Elderly: A Fall Detection Device With Zigbee-Based Positioning, Michael R. Putnam
Master's Theses
The following paper describes a fall detection and activity monitoring system with position detection based on Zigbee transceivers.The main objective is to reduce the time taken for emergency personnel to respond to falls among the elderly. Especially when the victim is unconscious or delirious, position tracking reduces location determination time within a busy hospital or nursing home environment and facilitates immediate treatment. Reduced response times correlate to decreased morbidity and mortality rates. Background is provided on the major wireless network advances currently deployed in a healthcare setting for asset and personnel tracking, etiology of falls, and several methods of detecting …
Developing Novel Prognostic Biomarkers For Multivariate Fracture Risk Prediction Algorithms, Ernest K. Poku, Mark R. Towler, Niamh M. Cummins, Jeff D. Newman
Developing Novel Prognostic Biomarkers For Multivariate Fracture Risk Prediction Algorithms, Ernest K. Poku, Mark R. Towler, Niamh M. Cummins, Jeff D. Newman
Chemical and Biochemical Engineering Faculty Research & Creative Works
Multivariate prediction algorithms such as FRAX® and QFracture Scores provide an opportunity for new prognostic biomarkers to be developed and incorporated, potentially leading to better fracture prediction. As more research is conducted into these novel biomarkers, a number of factors need to be considered for their successful development for inclusion in these algorithms. In this review, we describe two well-known multivariate prediction algorithms for osteoporosis fracture risk applicable to the UK population, FRAX and QFracture Scores, and comment on the current prognostic tools available for fracture risk; dual X-ray assessment, quantitative ultrasonography, and genomic/biochemical markers. We also highlight the factors …
Experimental Composite Guidance Conduits For Peripheral Nerve Repair: An Evaluation Of Ion Release, X. F. Zhang, A. Coughlan, H. O'Shea, Mark R. Towler, S. Kehoe, D. Boyd
Experimental Composite Guidance Conduits For Peripheral Nerve Repair: An Evaluation Of Ion Release, X. F. Zhang, A. Coughlan, H. O'Shea, Mark R. Towler, S. Kehoe, D. Boyd
Chemical and Biochemical Engineering Faculty Research & Creative Works
Poly (lactide-co-glycolide) (PLGA) - Pluronic F127 - glass composites have demonstrated excellent potential, from the perspective of controlled mechanical properties and cytocompatibility, for peripheral nerve regeneration. In addition to controlling the mechanical properties and cytotoxicity for such composite devices, the glass component may mediate specific responses upon implantation via degradation in the physiological environment and release of constituent elements. However, research focused on quantifying the release levels of such therapeutic ions from these experimental medical devices has been limited. To redress the balance, this paper explores the ion release profiles for Si4+, Ca2+, Na+, …
Two-Dimensional Blood Flow Velocity Estimation Using Ultrasound Speckle Pattern Dependence On Scan Direction And Velocity, Tiantian Xu
Department of Agricultural and Biological Systems Engineering: Dissertations, Theses, and Student Research
Cardiovascular disease is the leading cause death in the United States. Although emergency surgery and medicine can be used for cardiovascular disease treatment, the survivors will suffer for it afterwards. Ultrasound blood flow measurement provides a noninvasive way for cardiovascular diseases diagnosis. In this dissertation, three algorithms for blood flow velocity measurements were investigated and optimized. Feature tracking has been previously proposed for vector velocity measurement. In Chapter 3, the optimal amplitude and time thresholds for feature extraction were investigated to minimize flow estimate variance while providing sufficient spatial and temporal coverage of flow area. A new method of lateral …
Gallium Containing Glass Polyalkenoate Anti-Cancerous Bone Cements: Glass Characterization And Physical Properties, A. W. Wren, A. Coughlan, L. Placek, Mark R. Towler
Gallium Containing Glass Polyalkenoate Anti-Cancerous Bone Cements: Glass Characterization And Physical Properties, A. W. Wren, A. Coughlan, L. Placek, Mark R. Towler
Chemical and Biochemical Engineering Faculty Research & Creative Works
A gallium (Ga) glass series (0.48SiO2-0.40ZnO-0.12CaO, with 0.08 mol% substitution for ZnO) was developed to formulate a Ga-containing Glass Polyalkenoate Cement (GPC) series. Network connectivity (NC) and X-ray Photoelectron Spectroscopy (XPS) was employed to investigate the role of Ga3+ in the glass, where it is assumed to act as a network modifier. Ga-GPC series was formulated with E9 and E11 polyacrylic acid (PAA) at 50, 55 and 60 wt% additions. E11 working times (Tw) ranged from 68 to 96 s (Lcon.) and 106 s for the Ga-GPCs (LGa-1 and LGa-2). Setting times (Ts) …
Design, Analysis And Testing Of Haptic Feedback System For Laparoscopic Graspers In In Vivo Surgical Robots, Nikhil Salvi
Design, Analysis And Testing Of Haptic Feedback System For Laparoscopic Graspers In In Vivo Surgical Robots, Nikhil Salvi
Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research
Laparo-Endoscopic Single Site (LESS) Robotics Surgery is an advanced technology in the field of Minimally Invasive Surgery (MIS). The LESS surgical robots significantly improve the surgeon’s accuracy, dexterity and visualization, and reduce the invasiveness of surgical procedure results in faster recovery time and improved cosmetic results. In a standard robotic endosurgery, the palpation of tissues is performed by laparoscopic graspers located at the end effectors. The master-slave configuration in robotic surgery leads in remote access to the operation site. Therefore, surgeon’s ability to perceive valuable sensory information is severely diminished. Sensory information such as haptics, which is essential for safe …
Development And Characterization Of An In-House Custom Bioreactor For The Cultivation Of A Tissue Engineered Blood-Brain Barrier, Amin Hadi Mirzaaghaeian
Development And Characterization Of An In-House Custom Bioreactor For The Cultivation Of A Tissue Engineered Blood-Brain Barrier, Amin Hadi Mirzaaghaeian
Master's Theses
The development of treatments for neurological disorders such as Alzheimer’s and Parkinson’s disease begins by understanding what these diseases affect and the consequences of further manifestation. One particular region where these diseases can produce substantial problems is the blood-brain barrier (BBB). The BBB is the selective diffusion barrier between the circulating blood and the brain. The barrier’s main function is to maintain CNS homeostasis and protect the brain from the extracellular environment. The progression of BBB research has advanced to the point where many have modeled the BBB in vitro with aims of further characterizing and testing the barrier. Particularly, …