Open Access. Powered by Scholars. Published by Universities.®
Biomedical Engineering and Bioengineering Commons™
Open Access. Powered by Scholars. Published by Universities.®
- Institution
-
- Old Dominion University (61)
- California Polytechnic State University, San Luis Obispo (29)
- University of Nevada, Las Vegas (27)
- University of Arkansas, Fayetteville (13)
- Chapman University (9)
-
- Technological University Dublin (9)
- Purdue University (8)
- Ateneo de Manila University (5)
- Harrisburg University of Science and Technology (5)
- Kennesaw State University (5)
- Louisiana State University (5)
- University of Nebraska - Lincoln (5)
- Dartmouth College (4)
- San Jose State University (4)
- The University of Akron (4)
- University of Denver (4)
- University of Louisville (4)
- City University of New York (CUNY) (3)
- Georgia Southern University (3)
- Liberty University (3)
- Michigan Technological University (3)
- New Jersey Institute of Technology (3)
- Southern Methodist University (3)
- University of Connecticut (3)
- University of Malaya (3)
- University of North Florida (3)
- University of Texas at Tyler (3)
- Brigham Young University (2)
- Clemson University (2)
- University of Central Florida (2)
- Keyword
-
- Electroporation (8)
- Electric fields (7)
- Medical imaging (7)
- Machine Learning (6)
- Machine learning (6)
-
- Cells (5)
- Signal processing (5)
- Biomedical engineering (4)
- EEG (4)
- Electro-larynx (4)
- Federated learning (4)
- Intelligibility (4)
- Magnetic resonance imaging (4)
- Nanoparticles (4)
- Piezoelectric (4)
- Tissue engineering (4)
- Tissues (4)
- Tracking (4)
- Arduino (3)
- Biochemical markers (3)
- Biomedical (3)
- Biopsy (3)
- Biosensor (3)
- Biosensors (3)
- Brain (3)
- Cancer (3)
- Computer aided diagnosis (3)
- Daniel Felix Ritchie School of Engineering and Computer Science (3)
- Deep learning (3)
- Drug delivery (3)
- Publication Year
- Publication
-
- UNLV Theses, Dissertations, Professional Papers, and Capstones (24)
- Electrical & Computer Engineering Theses & Dissertations (22)
- Master's Theses (17)
- Electrical & Computer Engineering Faculty Publications (16)
- Bioelectrics Publications (11)
-
- Engineering Faculty Articles and Research (9)
- Conference Papers (8)
- Electronic Theses and Dissertations (7)
- Graduate Theses and Dissertations (7)
- Electrical Engineering (6)
- The Summer Undergraduate Research Fellowship (SURF) Symposium (6)
- Dissertations (5)
- Faculty Works (5)
- Biomedical Engineering (4)
- LSU Doctoral Dissertations (4)
- Symposium of Student Scholars (4)
- Williams Honors College, Honors Research Projects (4)
- Ateneo Laboratory for Intelligent Visual Environments (3)
- Biomedical Engineering Theses & Dissertations (3)
- College of Graduate Studies: Theses & Dissertations (3)
- Dartmouth College Ph.D Dissertations (3)
- Dissertations and Theses (3)
- Dissertations, Master's Theses and Master's Reports (3)
- Electrical Engineering Theses (3)
- School of Medical Diagnostics & Translational Sciences Publications (3)
- Student Works (2020-2029) (3)
- Theses and Dissertations (3)
- UNF Graduate Theses and Dissertations (3)
- Biomedical Engineering Undergraduate Honors Theses (2)
- Computer Engineering (2)
- Publication Type
Articles 151 - 180 of 270
Full-Text Articles in Biomedical Engineering and Bioengineering
Optimization Of Prosthetic Hands: Utilizing Modularity To Improve Grip Force, Grasp, And Versatility, Jordan William Harris
Optimization Of Prosthetic Hands: Utilizing Modularity To Improve Grip Force, Grasp, And Versatility, Jordan William Harris
UNLV Theses, Dissertations, Professional Papers, and Capstones
It has been demonstrated that although many varieties of upper limb prosthetics exist, commercially available prosthetics are outdated and unsatisfactory. Ineffectiveness and limitations have led to some prosthesis wearers having to own multiple devices, whereas others have given up on them entirely. Even though ample research has been conducted to design and test new hand designs, the industry appears to rest in an overall stagnated state.
It was proposed here, that one problem with prosthetic research is an excess of variables involved in testing, and therefore the improper application of the scientific method. It seems that each time a research …
Skin Tone Tracking Device (Chromaband), Ziyang Bian
Skin Tone Tracking Device (Chromaband), Ziyang Bian
Computer Engineering
It’s long been said that your skin is a window into your health and with many illnesses the first signs of trouble actually show up in your skin. So if we have this natural warning system, then why isn’t anyone able to effectively use it to predict changes in our health? The problem is that currently there is no reliable way to accurately measure the change in skin tone and how these changes may or may not change with variations in health. This project’s aim is to design and develop a device that will record the changes in a user’s …
Poly Drop, Zachary T. Scott, Lilly J. Paul
Poly Drop, Zachary T. Scott, Lilly J. Paul
Computer Engineering
Poly Drop is a software interface to control an Open Drop digital micro-fluidics system. We obtained a hardware system from Gaudi labs. Our task was to create a Graphical User Interface that made the control of the device easier and more automated for better testing. We created software that had 3 parts: a control GUI, arduino code to control the hardware, and Image Analysis that gives the user information such as location and color of liquid drops as they move across the electrode grid of the Open Drop system. The GUI was developed using Java Swing. The communication between the …
3d Printed Microfluidics, Hua Gong, Clayton Ramstedt, Adam T. Woolley, Gregory P. Nordin
3d Printed Microfluidics, Hua Gong, Clayton Ramstedt, Adam T. Woolley, Gregory P. Nordin
Biomedical Engineering Western Regional Conference
3D printing for microfluidic (lab-on-a-chip) devices
A Comprehensive Analysis On Eeg Signal Classification Using Advanced Computational Analysis, Kaushik Bhimraj
A Comprehensive Analysis On Eeg Signal Classification Using Advanced Computational Analysis, Kaushik Bhimraj
College of Graduate Studies: Theses & Dissertations
Electroencephalogram (EEG) has been used in a wide array of applications to study mental disorders. Due to its non-invasive and low-cost features, EEG has become a viable instrument in Brain-Computer Interfaces (BCI). These BCI systems integrate user's neural features with robotic machines to perform tasks. However, due to EEG signals being highly dynamic in nature, BCI systems are still unstable and prone to unanticipated noise interference. An important application of this technology is to help facilitate the lives of the tetraplegic through assimilating human brain impulses and converting them into mechanical motion. However, BCI systems are remarkably challenging to implement …
A Wireless, Passive Sensor For Measuring Temperature At Orthopedic Implant Sites For Early Diagnosis Of Infections, Salil Sidharthan Karipott
A Wireless, Passive Sensor For Measuring Temperature At Orthopedic Implant Sites For Early Diagnosis Of Infections, Salil Sidharthan Karipott
Dissertations, Master's Theses and Master's Reports
Sensorized implants with embedded wireless, passive temperature sensors were developed for early detection of implant-associated infections. The operation principle of the sensor is based on the hypothesis that infections can lead to an increase in local temperature prior to the rise of body temperature. The sensor was an inductive capacitive (LC) circuit that has been used for monitoring of different parameters wirelessly, often in difficult to access environments. The sensor was fabricated on to an interference screw, which is used for tendon and ligament reconstruction surgeries. In this project, a sensorized interference screw was designed and fabricated by accommodating an …
Implantable Wireless Sensor Networks: Application To Measuring Temperature For In Vivo Detection Of Infections, Praharsh Madappaly Veetil
Implantable Wireless Sensor Networks: Application To Measuring Temperature For In Vivo Detection Of Infections, Praharsh Madappaly Veetil
Dissertations, Master's Theses and Master's Reports
It is has been proven that infection in the body cause a local temperature increase due to localized inflammation. Therefore, a method to provide early diagnostic or long-term tracking of this infection will provide great benefits to patients with diabetic foot ulcers or sickle cell disease, and those receiving hemodialysis where they suffer from a weakened immune system. The goal of this project is to develop an implantable wireless temperature sensor based on a wireless sensor network system for monitoring infections in situ. The analog signals from the thermistors are digitized and wirelessly transmitted to a computer with an ez430-rf2500 …
An Emg-Based Patient Monitoring System Using Zynq Soc Device, Farhad Fallahlalehzari
An Emg-Based Patient Monitoring System Using Zynq Soc Device, Farhad Fallahlalehzari
UNLV Theses, Dissertations, Professional Papers, and Capstones
This thesis describes the design, development, and testing of an EMG-based patient monitoring system using the Zynq device. Zynq is a system on chip device designed by Xilinx which consists of an ARM dual cortex-A9 processor as well as an FPGA integrated into one chip. This work also analyzes the performance of image-processing algorithms on this system and compares that performance to more traditional PC-based systems. Image processing algorithms, such as Sobel edge detection, dilation and erosion, could be used in conjunction with a camera for the patient monitoring purposes. These algorithms often perform sub-optimally on processors because of their …
Radiation Therapy And Dosing Material Transport Methodology, Robert O'Brien
Radiation Therapy And Dosing Material Transport Methodology, Robert O'Brien
UNLV Theses, Dissertations, Professional Papers, and Capstones
A technique is examined here that utilizes high energy beta decays from a short lived radioisotope to treat medical conditions such as shallow cancerous lesions. A major benefit of beta particle interaction in tissue is a fixed penetration depth for the charged particle, with dose limited to the ultimate range of the beta particle. This method improves on some current techniques of radioactive brachytherapy, where "seeds" are placed inside patients through temporary or permanent implantation in order to kill cancerous cells or inhibit growth of tissue. The use of low energy gamma-rays is the most common method of treatment currently …
The Effects Of Cryopreservation On Human Dental Pulp-Derived Mesenchymal Stem Cells, Allison Elaine Tomlin
The Effects Of Cryopreservation On Human Dental Pulp-Derived Mesenchymal Stem Cells, Allison Elaine Tomlin
UNLV Theses, Dissertations, Professional Papers, and Capstones
Many studies have demonstrated clinical applications for the use of dental pulp stem cells (DPSC) for the treatment of various conditions. This has driven medical and scientific interest in the collection, isolation and banking of DPSC tissues for research into these potential therapies. Few studies to date have evaluated the viability of DPSC following long-term cryopreservation. The purpose of this study is to evaluate the effects of cryopreservation on dental pulp-derived stem cells (DPSC) viability over a period of three years. Dental pulp-derived stem cells were isolated and cultured from thirty-one healthy teeth. DPSC isolates were assessed for doubling-time and …
Behavior Classification Using Multi-Site Lfp And Ecog Signals, Adam O. Hebb, Hosein M. Golshan, Sara J. Hanrahan, Joshua Nedrud, Mohammad H. Mahoor
Behavior Classification Using Multi-Site Lfp And Ecog Signals, Adam O. Hebb, Hosein M. Golshan, Sara J. Hanrahan, Joshua Nedrud, Mohammad H. Mahoor
Electrical and Computer Engineering: Graduate Student Scholarship
Abstract-Deep Brain Stimulation (DBS) is an effective therapy that alleviates the motor signs of Parkinson’s disease (PD). Existing DBS is open loop, providing a time invariant stimulation pulse train that may generate cognitive, speech, and balance side effects. A closed-loop DBS system that utilizes appropriate physiological control variables may improve therapeutic results, reduce stimulation side effects, and extend battery life of pulse generators. Furthermore, by customizing DBS to a patient’s behavioral goal, side effects of stimulation may arise only when they are non-detrimental to the patient’s current goals. Therefore, classification of human behavior using physiological signals is an …
Ionic Basis Of Ventricular Action Potentials, Ariel L. Escobar
Ionic Basis Of Ventricular Action Potentials, Ariel L. Escobar
Science Seminar Series
Dr. Escobar will talk about his cutting-edge approach to understanding molecular mechanisms underlying electrical activity in the heart.
Mechanical Reliability Of Implantable Polyimide-Based Magnetic Microactuators For Biofouling Removal, Christian G. Figueroa-Espada, Qi Yang, Hyowon Lee
Mechanical Reliability Of Implantable Polyimide-Based Magnetic Microactuators For Biofouling Removal, Christian G. Figueroa-Espada, Qi Yang, Hyowon Lee
The Summer Undergraduate Research Fellowship (SURF) Symposium
Hydrocephalus is a neurological disorder that typically requires a long-term implantation of a shunt system to manage its symptoms. These shunt systems are notorious for their extremely high failure rate. More than 40% of all implanted shunt systems fail within the first year of implantation. On average, 85% of all hydrocephalus patients with shunt systems undergo at least two shunt-revision surgeries within 10 years of implantation. A large portion of this high failure rate can be attributed to biofouling-related obstructions and infections. Previously, we developed flexible polyimide-based magnetic microactuators to remove obstructions formed on hydrocephalus shunts. To test the long-term …
Automated Microscopy Platform For High-Throughput Analysis Of Cellular Characteristics, Hussam Ibrahim
Automated Microscopy Platform For High-Throughput Analysis Of Cellular Characteristics, Hussam Ibrahim
Physics: Student Scholarship & Creative Works
Existing microscopy platforms allow analysis post-hoc, but not in real time. This is an issue in the world of Bioengineering because you are limited to performing further analysis on specimen. The aim of my research was to design a sophisticated system whereby information can be exchanged between the software which acquires images and software that analyzes the images immediately after acquisition. In this system, images would be acquired by the microscope and analyzed by customized scripts (MATLAB, Mathworks) in real time. Specifically, MATLAB would wait for new images to be saved on the hard drive, import these images, and perform …
Microbubble Generation By Piezoelectric Transducers For Biomedical Studies, Mohammed Alkhazal
Microbubble Generation By Piezoelectric Transducers For Biomedical Studies, Mohammed Alkhazal
Electrical & Computer Engineering Theses & Dissertations
Bubbles induced by blast waves or shocks are speculated as the major cause of damage in biological cells in mild traumatic brain injuries (TBI). Microbubble collapse was found to induce noticeable cell detachment from the cell substrate, changes in focal adhesion, and biomechanics. To better understand the bubble mechanism, a system needs to be constructed which allows clear differentiation on the impact of bubbles from that of shocks. Such a generator needs to be low profile in order to place under a microscope. A piezoelectric transducer system was designed to meet the need. The system uses either a flat or …
A 'Tissue Model' To Study The Barrier Effects Of Living Tissues On The Reactive Species Generated By Surface Air Discharge, Tongtong He, Dingxin Liu, Han Xu, Zhichao Liu, Dehui Xu, Dong Li, Qiosong Li, Mingzhe Rong, Michael G. Kong
A 'Tissue Model' To Study The Barrier Effects Of Living Tissues On The Reactive Species Generated By Surface Air Discharge, Tongtong He, Dingxin Liu, Han Xu, Zhichao Liu, Dehui Xu, Dong Li, Qiosong Li, Mingzhe Rong, Michael G. Kong
Bioelectrics Publications
Gelatin gels are used as surrogates of human tissues to study their barrier effects on incoming reactive oxygen and nitrogen species (RONS) generated by surface air discharge. The penetration depth of nitrite into gelatin gel is measured in real time during plasma treatment, and the permeabilities of nitrite, nitrate, O3 and H2O2 through gelatin gel films are quantified by measuring their concentrations in the water underneath such films after plasma treatment. It is found that the penetration speed of nitrite increases linearly with the mass fraction of water in the gelatin gels, and the permeabilities of …
Validation Of A Confocal Light Sheet Microscope Using Push Broom Translation For Biomedical Applications, Joshua Hutcheson
Validation Of A Confocal Light Sheet Microscope Using Push Broom Translation For Biomedical Applications, Joshua Hutcheson
Graduate Theses and Dissertations
There exists a need for research of optical methods capable of image cytometry suitable for point-of-care technology. To propose am optical approach with no moving parts for simplification of mechanical components for the further development of the technology to the poin-of-care, a linear sensor with push broom translation method. Push broom translation is a method of moving objects by the sensor for an extended field of view. A polydimethylsiloxane (PDMS) microfluidic chamber with a syringe pump was used to deliver objects by the sensor. The volumetric rate of the pump was correlated to the integration time of the sensor to …
Portable High Throughput Digital Microfluidics And On-Chip Bacteria Cultures, Yiyan Li
Portable High Throughput Digital Microfluidics And On-Chip Bacteria Cultures, Yiyan Li
UNLV Theses, Dissertations, Professional Papers, and Capstones
An intelligent, portable, and high throughput digital microfluidic (DMF) system is developed. Chapter 1 introduces microfluidics and DMF systems. In Chapter 2, a low-cost and high resolution capacitive-to-digital converter integrated circuit is used for droplet position detection. A field-programmable gate array FPGA is used as the integrated logic hub of the system for highly reliable and efficient control of the circuit. In this chapter a fast-fabricating PCB (printed circuit board) substrate microfluidic system is proposed. Smaller actuation threshold voltages than those previously reported are obtained. Droplets (3 µL) are actuated using 200 V, 500 Hz DC pulses. Droplet positions can …
Experimental Assessment Of Mouse Sociability Using An Automated Image Processing Approach, Frency Varghese, Jessica A. Burket, Andrew D. Benson, Stephen I. Deutsch, Christian W. Zemlin
Experimental Assessment Of Mouse Sociability Using An Automated Image Processing Approach, Frency Varghese, Jessica A. Burket, Andrew D. Benson, Stephen I. Deutsch, Christian W. Zemlin
Electrical & Computer Engineering Faculty Publications
Mouse is the preferred model organism for testing drugs designed to increase sociability. We present a method to quantify mouse sociability in which the test mouse is placed in a standardized apparatus and relevant behaviors are assessed in three different sessions (called session I, II, and III). The apparatus has three compartments (see Figure 1), the left and right compartments contain an inverted cup which can house a mouse (called “stimulus mouse”). In session I, the test mouse is placed in the cage and its mobility is characterized by the number of transitions made between compartments. In session II, a …
The Connectivity Domain: Analyzing Resting State Fmri Data Using Feature-Based Data-Driven And Model-Based Methods, Armin Iraji, Vince D. Calhoun, Natalie M. Wiseman, Esmaeil Davoodi-Bojd, Mohammad R. N. Avanaki, Zhifeng Kou
The Connectivity Domain: Analyzing Resting State Fmri Data Using Feature-Based Data-Driven And Model-Based Methods, Armin Iraji, Vince D. Calhoun, Natalie M. Wiseman, Esmaeil Davoodi-Bojd, Mohammad R. N. Avanaki, Zhifeng Kou
Biomedical Engineering Faculty Research Publications
Spontaneous fluctuations of resting state functional MRI (rsfMRI) have been widely used to understand the macro-connectome of the human brain. However, these fluctuations are not synchronized among subjects, which leads to limitations and makes utilization of first-level model-based methods challenging. Considering this limitation of rsfMRI data in the time domain, we propose to transfer the spatiotemporal information of the rsfMRI data to another domain, the connectivity domain, in which each value represents the same effect across subjects. Using a set of seed networks and a connectivity index to calculate the functional connectivity for each seed network, we transform data into …
Utilizing Brain-Computer Interfacing To Control Neuroprosthetic Devices, Cheyne J. Angy
Utilizing Brain-Computer Interfacing To Control Neuroprosthetic Devices, Cheyne J. Angy
Senior Honors Theses
Advances in neuroprosthetics in recent years have made an enormous impact on the quality of life for many people with disabilities, helping them regain the functionality of damaged or impaired abilities. One of the main hurdles to regaining full functionality regarding neuroprosthetics is the integration between the neural prosthetic device and the method in which the neural prosthetic device is controlled or manipulated to function correctly and efficiently. One of the most promising methods for integrating neural prosthetics to an efficient method of control is through Brian-computer Interfacing (BCI). With this method, the neuroprosthetic device is integrated into the human …
Compressive Sensing Framework For Mass Spectrometry Data Analysis, Khalfalla Ahmad Kh. Awedat
Compressive Sensing Framework For Mass Spectrometry Data Analysis, Khalfalla Ahmad Kh. Awedat
Dissertations
Mass Spectrometry (MS) data is ideal for identifying unique bio-signatures of diseases. However, the high dimensionality of MS data hinders any promising MS-based proteomics development. The goal of this dissertation is to develop an accurate classification tool by employing compressive sensing (CS). Not only can CS significantly reduce MS data dimensionality, but it also will allow for full reconstruction of original data. The framework developed in this work is based on using L2 and a mixed L2-L1 norms, allowing an overdetermined system to be resolved. The results show that the L2- based algorithm with regularization terms has a better performance …
Reduced Haemodynamic Coupling And Exercise Are Associated With Vascular Stiffening In Pulmonary Arterial Hypertension, Alessandro Bellofiore, Eric Dinges, Robert Naeije, Hamorabi Mkrdichian, Lauren Beussink-Nelson, Melissa Bailey, Michael Cuttica, Ranya Sweis, James Runo, Jon Keevil, Christopher Francois, Sanjiv Shah, Naomi Chesler
Reduced Haemodynamic Coupling And Exercise Are Associated With Vascular Stiffening In Pulmonary Arterial Hypertension, Alessandro Bellofiore, Eric Dinges, Robert Naeije, Hamorabi Mkrdichian, Lauren Beussink-Nelson, Melissa Bailey, Michael Cuttica, Ranya Sweis, James Runo, Jon Keevil, Christopher Francois, Sanjiv Shah, Naomi Chesler
Faculty Publications
Inadequate right ventricular (RV) and pulmonary arterial (PA) functional responses to exercise are important yet poorly understood features of pulmonary arterial hypertension (PAH). This study combined invasive catheterisation with echocardiography to assess RV afterload, RV function and ventricular–vascular coupling in subjects with PAH.
Detection Of Electrical Alternans In Ventricular Depolarization Phase Of Human Electrocardiogram, David R. Wasemiller
Detection Of Electrical Alternans In Ventricular Depolarization Phase Of Human Electrocardiogram, David R. Wasemiller
Theses and Dissertations--Biomedical Engineering
T-wave Alternans (TWA) in an electrocardiogram (ECG) has received considerable interest as a potential predictor of sudden cardiac death (SCD). However, large clinical trials have shown that while TWA has a very high negative predictive value, its positive predictive value is poor. Results of previous studies suggest that arrhythmia onset can be affected by the phase relationship of alternans of the depolarization and repolarization phase of the action potentials of the ventricles. To assess this relationship, one would first need to establish that depolarization alternans can be detected and then develop methods to determine its relationship with repolarization alternans, which …
Emlighten, Emily Mulvany
Emlighten, Emily Mulvany
Williams Honors College, Honors Research Projects
This project is focused on creating a system to increase patient satisfaction in hospitals. My senior design team has been working hand in hand with the emergency department of Akron General to design this system called EMlighten. The goal is to create an experience for patients where they exit the hospital feeling more satisfied than they currently are. Patient satisfaction is a key performance indicator used by many hospitals to determine how much additional funding each hospital department is granted. If patients feel more satisfied, not only is that indicative of better care, but departments will receive extra funding. EMlighten …
Polyethylene Oxide Nanofiber Production By Electrospinning, H. E. Schneider, J. G. Steuber, W. Du, M. Mortazavi, D. W. Bullock
Polyethylene Oxide Nanofiber Production By Electrospinning, H. E. Schneider, J. G. Steuber, W. Du, M. Mortazavi, D. W. Bullock
Journal of the Arkansas Academy of Science
Electrospinning is an inexpensive technique that is used to produce nanofibers for a variety of applications. In electrospinning, a polymer solution is dispensed from a hypodermic-like syringe where an intense electric field attracts the solution to a collector while drawing the polymer into a very thin fiber. The diameter of the fiber can be controlled by tuning the process parameters such as the applied electric field, solution flow rate, distance between syringe tip and collector, and the collector geometry. In this paper we describe results from electrospinning poly(ethylene oxide) (PEO), a likely candidate for applications involving scaffolding for tissue engineering. …
Intracellular Ros Mediates Gas Plasma-Facilitated Cellular Transfection In 2d And 3d Cultures, Dehui Xu, Biqing Wang, Yujing Xu, Zeyu Chen, Qinjie Cui, Yanjie Yang, Hailan Chen, Michael G. Kong
Intracellular Ros Mediates Gas Plasma-Facilitated Cellular Transfection In 2d And 3d Cultures, Dehui Xu, Biqing Wang, Yujing Xu, Zeyu Chen, Qinjie Cui, Yanjie Yang, Hailan Chen, Michael G. Kong
Bioelectrics Publications
This study reports the potential of cold atmospheric plasma (CAP) as a versatile tool for delivering oligonucleotides into mammalian cells. Compared to lipofection and electroporation methods, plasma transfection showed a better uptake efficiency and less cell death in the transfection of oligonucleotides. We demonstrated that the level of extracellular aqueous reactive oxygen species (ROS) produced by gas plasma is correlated with the uptake efficiency and that this is achieved through an increase of intracellular ROS levels and the resulting increase in cell membrane permeability. This finding was supported by the use of ROS scavengers, which reduced CAP-based uptake efficiency. In …
Modeling Early Stage Bone Regeneration With Biomimetic Electrospun Fibrinogen Nanofibers And Adipose-Derived Mesenchymal Stem Cells, Michael P. Francis, Yas M. Moghaddam-White, Patrick C. Sachs, Matthew J. Beckman, Stephen M. Chen, Gary L. Bowlin, Lynne W. Elmore, Shawn E. Holt
Modeling Early Stage Bone Regeneration With Biomimetic Electrospun Fibrinogen Nanofibers And Adipose-Derived Mesenchymal Stem Cells, Michael P. Francis, Yas M. Moghaddam-White, Patrick C. Sachs, Matthew J. Beckman, Stephen M. Chen, Gary L. Bowlin, Lynne W. Elmore, Shawn E. Holt
School of Medical Diagnostics & Translational Sciences Publications
The key events of the earliest stages of bone regeneration have been described in vivo although not yet modeled in an in vitro environment, where mechanistic cell-matrix-growth factor interactions can be more effectively studied. Here, we explore an early-stage bone regeneration model where the ability of electrospun fibrinogen (Fg) nanofibers to regulate osteoblastogenesis between distinct mesenchymal stem cells populations is assessed. Electrospun scaffolds of Fg, polydioxanone (PDO), and a Fg:PDO blend were seeded with adipose-derived mesenchymal stem cells (ASCs) and grown for 7-21 days in osteogenic differentiation media or control growth media. Scaffolds were analyzed weekly for histologic and molecular …
A Software Application For Cardiac-Gated Computerized Tomography Scanning, Stephen Caldwell, Trevor Engelsman
A Software Application For Cardiac-Gated Computerized Tomography Scanning, Stephen Caldwell, Trevor Engelsman
Williams Honors College, Honors Research Projects
Computerized tomography (CT) scans are a common clinical imaging procedure used worldwide. Operating in the X-Ray spectrum, these machines rotate scanners around a stationary body in order to compile two-dimensional images into a unified three-dimensional image. With adjustment to scan frequency and intensity, internal features such as muscles, organs, and tendons can easily be viewed. However, the heart has long evaded CT use due to its near-constant motion. Recently, cardiac-gated scans have entered the market as a technique to image the heart at a specific moment in time when it is nearly still - the quiescent period. Occurring during rapid …
Assessment Of Optimized Electrode Configuration In Electrical Impedance Myography Study Using Genetic Algorithm Via Finite Element Model, Somen Baidya
College of Graduate Studies: Theses & Dissertations
Electrical Impedance Myography (EIM) is a neurophysiologic technique in which high- frequency, low-intensity electrical current is applied via surface electrodes over a muscle or muscle group of interest and the resulting electrical parameters (resistance, reactance and phase) are analyzed to isolate diseased muscles from healthy ones. Beside muscle properties, some other anatomic and non-anatomic factors like muscle shape, subcutaneous fat (SF) thickness, inter-electrode distance, etc. also impact the major EIM parameters and thus affect the EIM analysis outcomes. The purpose of this study is to explore the effects of variation in some of these factors impose on EIM parameters and …