Validation Of Energygauge® Usa Using The Hers Bestest, Florida Solar Energy Center, Philip W. Fairey Dec 2004

Validation Of Energygauge® Usa Using The Hers Bestest, Florida Solar Energy Center, Philip W. Fairey

FSEC Energy Research Center®

This report presents results from the testing and validation of the EnergyGauge USA home energy rating software conducted using the HERS BESTEST procedures. The results show that EnergyGauge USA is an excellent and verifiable simulation program that is capable of meeting all national requirements for home energy rating software tools.


Cold Climate Case Study; High Efficiency North Dakota Twin Homes, Florida Solar Energy Center, Dave Chasar Dec 2004

Cold Climate Case Study; High Efficiency North Dakota Twin Homes, Florida Solar Energy Center, Dave Chasar

FSEC Energy Research Center®

The Eastern Dakota Housing Alliance has completed 8 of 20 planned multi-family and single-family dwellings on Selkirk Circle in Grand Forks, North Dakota. Four twin-home (duplex) units were completed in March of 2003 (Phase I) and four more identical units were completed in February of 2004 (Phase II). Four additional units (Phase III) are due for completion by mid-summer, 2004. Design assistance and performance testing were provided by the Building America Industrialized Housing Project with the goal of achieving up to 50% energy savings over the 1993 Model Energy Code.

To approach this level of savings, various envelope and equipment …


Cooling Load Reduction And Air Conditioner Design In A 19th Century Florida House Museum, Florida Solar Energy Center, Dave Chasar Nov 2004

Cooling Load Reduction And Air Conditioner Design In A 19th Century Florida House Museum, Florida Solar Energy Center, Dave Chasar

FSEC Energy Research Center®

Restoration plans at the H.S. Williams house included the installation of a space conditioning system. This contract report details how building envelope construction and air conditioner design were optimized as a system. Many aspects of the effort lent themselves to maintaining important "character-defining" features of the building including the resurrection of passive cooling attributes like light colored exterior paint and operable storm shutters. In addition, outside air infiltration was measured on the Williams house and six other balloon-frame homes to document this often significant cooling load component.


Performance And Applications Of Gossamer Wind (Tm) Solar Powered Ceiling Fans, Florida Solar Energy Center, M. Lubliner Sep 2004

Performance And Applications Of Gossamer Wind (Tm) Solar Powered Ceiling Fans, Florida Solar Energy Center, M. Lubliner

FSEC Energy Research Center®

Ceiling fans provide a cooling breeze, reduce temperature stratification and improve thermal comfort. Ceiling fans save energy in homes by improving thermal comfort, which results in changes to the thermostat set-point or reduced use of air conditioning.


Photovoltaics: Disaster And Energy Security Applications, Florida Solar Energy Center, William Young Aug 2004

Photovoltaics: Disaster And Energy Security Applications, Florida Solar Energy Center, William Young

FSEC Energy Research Center®

The modernization of our lives with the use of electronic devices has contributed to a steadily increasing dependence on electric power. The degree of importance of electricity is temporarily highlighted with any type of power outage, whether caused by an accident, a natural disaster or a terrorist attack. A disaster can leave many people without adequate medical services, potable water, electrical service and communications.

There is a value in applying photovoltaics (solar electric) to create disaster-resistant buildings and communities, which is to reduce losses and improve quality of life. Photovoltaics provide a viable source of electric power for energy security …


Geographic Variation In Potential Of Rooftop Residential Photovoltaic Electric Power Production In The United States, Florida Solar Energy Center, Matthew Lombardi Aug 2004

Geographic Variation In Potential Of Rooftop Residential Photovoltaic Electric Power Production In The United States, Florida Solar Energy Center, Matthew Lombardi

FSEC Energy Research Center®

This paper describes a geographic evaluation of Zero Energy Home (ZEH) potential, specifically an assessment of residential roof-top solar electric photovoltaic (PV) performance around the United States and how energy produced would match up with very-efficient and super-efficient home designs. We performed annual simulations for 236 TMY2 data locations throughout the United States on two highly-efficient one-story 3-bedroom homes with a generic grid-tied solar electric 2 kW PV system. These annual simulations show how potential annual solar electric power generation (kWh) and potential energy savings from PV power vary geographically around the U.S. giving the user in a specific region …


Energy Star Manufactured Homes: The Plant Certification Process, Florida Solar Energy Center, Dave Chasar Aug 2004

Energy Star Manufactured Homes: The Plant Certification Process, Florida Solar Energy Center, Dave Chasar

FSEC Energy Research Center®

In an on-going collaboration over the last ten years, researchers have worked with the manufactured housing industry offering building science advice and conducting diagnostic testing (Chandra et al 2002). This partnership resulted in the first two HUD code ENERGY STAR homes in 1997 and the development of standardized, in-plant Duct Blaster testing in 2001. One manufacturer is currently testing duct leakage on every home in 12 factories, representing over 8,000 homes per year.

In 2001, the U.S. Environmental Protection Agency (EPA) introduced the ENERGY STAR label for manufactured homes. Guidelines for this program focus on certification of the HUD-code plant …


Measured Energy And Peak Demand Reductionfrom High Efficiency Air Conditioner Replacement, Florida Solar Energy Center, John Masiello Aug 2004

Measured Energy And Peak Demand Reductionfrom High Efficiency Air Conditioner Replacement, Florida Solar Energy Center, John Masiello

FSEC Energy Research Center®

A utility load research project has monitored over 167 single-family residences in Central Florida collecting baseline 15-minute data on air conditioner (AC) power consumption, interior air temperatures and appliance loads over a two year period. Within the project we evaluated the impact of replacing older existing air conditioners with modern high efficiency equipment.


Preliminary Evaluation Of Performance Enhanced Relocatable Classrooms In Three Climates, Florida Solar Energy Center, Danny Parker Aug 2004

Preliminary Evaluation Of Performance Enhanced Relocatable Classrooms In Three Climates, Florida Solar Energy Center, Danny Parker

FSEC Energy Research Center®

A research project has monitored a specifically modified energy efficient portable classroom compared with a standard unit, in side-by-side installations in three states (NY, NC and FL). Energy performance data is summarized in this paper.


Assessing Six Residential Ventilation Techniques In Hot And Humid Climates, Florida Solar Energy Center, Neil Moyer Aug 2004

Assessing Six Residential Ventilation Techniques In Hot And Humid Climates, Florida Solar Energy Center, Neil Moyer

FSEC Energy Research Center®

The addition of mechanical ventilation air to "tight" homes in hot and humid climates may adversely impact health, building durability, comfort and energy use by raising indoor humidity levels (RH) above 50%. High indoor humidity has been linked to microbial growth, building material decay, discomfort, and increased energy use (Moyer, et al, 2001). High indoor humidity in "tight" homes with mechanical ventilation has been documented in various Building America projects in hot humid locations (Rudd 2003).

The research described here quantifies the energy use, and humidity impacts of six mechanical ventilation strategies installed serially in a new, Energy Star Manufactured …


A Review Of Hot Water Draw Profiles Used In Performance Analysis Of Residential Domestic Hot Water Systems, Florida Solar Energy Center, Philip W. Fairey Jul 2004

A Review Of Hot Water Draw Profiles Used In Performance Analysis Of Residential Domestic Hot Water Systems, Florida Solar Energy Center, Philip W. Fairey

FSEC Energy Research Center®

As a result of efforts on the part of various organizations to improve the specifications for performance-based analysis of energy use in residences, the literature on residential hot water use has been reviewed, specifically as it relates to typical hot water use draw profiles. A number of daily hot water use draw profiles have been identified and reviewed.


Assuring Power In A Disaster And Providing Energy Security, Florida Solar Energy Center, William Young Jul 2004

Assuring Power In A Disaster And Providing Energy Security, Florida Solar Energy Center, William Young

FSEC Energy Research Center®

Daily use of a myriad of electrical and electronic devices has contributed to a steadily increasing dependence on electric power. The degree of importance of electricity is temporarily highlighted with any type of power outage, whether caused by a disaster as destructive as a Hurricane Andrew or as minor as an afternoon thunderstorm knocking down local utility lines. After September 11, terrorism added a new dimension to our definition of energy security. While the American public is dependent on utility providers to meet energy needs, it is the right and the responsibility of each citizen to become aware of energy …


Flexible Roofing Facility: 2003 Summer Test Results, Florida Solar Energy Center, Danny Parker Jul 2004

Flexible Roofing Facility: 2003 Summer Test Results, Florida Solar Energy Center, Danny Parker

FSEC Energy Research Center®

The Flexible Roof Facility (FRF) is a test facility in Cocoa, Florida designed to evaluate five roofing systems at a time against a control roof with black shingles and vented attic (Figure E-1). The testing evaluates how roofing systems impact summer residential cooling energy use and peak demand. In the summer of 2003, the following roofing systems were tested: Galvalume® unfinished 5-vee metal with vented attic (2nd year of exposure); sealed attic with proprietary configuration; high reflectance brown metal shingle with vented attic; galvanized unfinished 5-vee metal with vented attic (2nd year of exposure); black shingles with standard attic ventilation …


Optimizing Manufactured Housing Energy Use, Florida Solar Energy Center, Mark Mcginley May 2004

Optimizing Manufactured Housing Energy Use, Florida Solar Energy Center, Mark Mcginley

FSEC Energy Research Center®

In partnership with the Florida Solar Energy Center (FSEC), two manufactured homes were located on North Carolina A&T State University's campus in Greensboro, NC and used in a side-by-side energy consumption comparison. One of the homes was built to the basic HUD code standard and the other was constructed with features expected to produce a home that was 50% more energy efficient.

FSEC and NCATSU began monitoring energy performance in both homes. In addition, the performance of each unit was evaluated using a DOE2 based computer energy analysis program developed by FSEC. A comparison of the performance of the units …


Standards For Clean Air Florida Homes, Florida Solar Energy Center, Subrato Chandra Mar 2004

Standards For Clean Air Florida Homes, Florida Solar Energy Center, Subrato Chandra

FSEC Energy Research Center®

These standards are designed for new, slab on grade homes built in Florida. Changes to the standards may be necessary for other house construction types. These standards are not meant to be exclusionary. The home builder may submit alternative materials or design details which will result in equivalent performance. These standards complement all building codes and do not supersede any codes.


Alleviating Moisture Problems Hot, Humid Climate Housing, Florida Solar Energy Center, Subrato Chandra Feb 2004

Alleviating Moisture Problems Hot, Humid Climate Housing, Florida Solar Energy Center, Subrato Chandra

FSEC Energy Research Center®

The Southeastern U.S. experiences hot, humid conditions throughout the summer months and in Florida, one of the high growth states with large number of homes, these conditions can prevail throughout most of the year. As a result it is not uncommon to find extensive mold, soft drywall, buckled floors, damaged ceilings and other moisture problems in new and existing site built and manufactured homes. Since 1999, as a result of participation in the U.S. DOE funded Building America program, the authors have developed first hand experience and conducted research in these areas. This paper provides a brief summary of the …


Florida's Energy Future: Opportunities For Our Economy, Environment And Security - Executive Summary, Florida Solar Energy Center, Philip W. Fairey Jan 2004

Florida's Energy Future: Opportunities For Our Economy, Environment And Security - Executive Summary, Florida Solar Energy Center, Philip W. Fairey

FSEC Energy Research Center®

The future of Florida's economy, environment and security is inextricably intertwined with our energy use decisions. Our state has one of the nation's fastest growing populations, promoting rapid expansion of an energy industry that imports its fuel supplies. Florida exports approximately $32 billion per year for these energy fuels. Moreover, the Florida economy depends critically on tourism and agriculture, and the fuels and energy products that maintain them. Our pristine environment is the primary natural resource supporting this unique economic engine and the adverse effects of our rapidly growing energy use now stress it. Our State's economic well-being and security …


Florida's Energy Future: Opportunities For Our Economy, Environment And Security - Appendices, Florida Solar Energy Center, Philip W. Fairey Jan 2004

Florida's Energy Future: Opportunities For Our Economy, Environment And Security - Appendices, Florida Solar Energy Center, Philip W. Fairey

FSEC Energy Research Center®

The future of Florida's economy, environment and security is inextricably intertwined with our energy use decisions. Our state has one of the nation's fastest growing populations, promoting rapid expansion of an energy industry that imports its fuel supplies. Florida exports approximately $32 billion per year for these energy fuels. Moreover, the Florida economy depends critically on tourism and agriculture, and the fuels and energy products that maintain them. Our pristine environment is the primary natural resource supporting this unique economic engine and the adverse effects of our rapidly growing energy use now stress it. Our State's economic well-being and security …


Florida's Energy Future: Opportunities For Our Economy, Environment And Security, Florida Solar Energy Center, Philip W. Fairey Jan 2004

Florida's Energy Future: Opportunities For Our Economy, Environment And Security, Florida Solar Energy Center, Philip W. Fairey

FSEC Energy Research Center®

The future of Florida's economy, environment and security is inextricably intertwined with our energy use decisions. Our state has one of the nation's fastest growing populations, promoting rapid expansion of an energy industry that imports its fuel supplies. Florida exports approximately $32 billion per year for these energy fuels. Moreover, the Florida economy depends critically on tourism and agriculture, and the fuels and energy products that maintain them. Our pristine environment is the primary natural resource supporting this unique economic engine and the adverse effects of our rapidly growing energy use now stress it. Our State's economic well-being and security …


The Removal Of Motion Artifacts From Non-Invasive Blood Pressure Measurements, Paresh Thakkar Jan 2004

The Removal Of Motion Artifacts From Non-Invasive Blood Pressure Measurements, Paresh Thakkar

Electronic Theses and Dissertations

Modern Automatic Blood Pressure Measurement Techniques are based on measuring the cuff pressure and on sensing the pulsatile amplitude variations. These measurements are very sensitive to motion of the patient or the surroundings where the patient is. The slightest unexpected movements could offset the readings of the automatic Blood Pressure meter by a large amount or render the readings totally meaningless. Every effort must be taken to avoid subjecting the body of the patient or the patient's surroundings to motion for obtaining a reliable reading. But there are situations in which we need Blood Pressure Measurements with the patient or …


Raindrop Size Distribution Retrieval And Evaluation Using An S-Band Radar Profiler, Fang Fang Jan 2004

Raindrop Size Distribution Retrieval And Evaluation Using An S-Band Radar Profiler, Fang Fang

Electronic Theses and Dissertations

Vertical pointing Doppler radar profilers are used to explore the vertical structure of precipitation cloud systems and to provide validation information for use in weather research. In this thesis, a theoretical radar rain-backscatter model was developed to simulate profiler Doppler spectra as a function of assumed rain parameters, of which the raindrop size distribution (DSD) is the fundamental quantity used to describe the characteristics of rain. Also, profiler observations during stratiform rain are analyzed to retrieve the corresponding rain DSD’s. In particular, a gamma distribution model is introduced, which uses Rayleigh scattering portion of the Doppler velocity spectrum to estimate …


Techniques For Assessing And Improving Performance In Navigation And Wayfinding Using Mobile Augmented Reality, Brian Goldiez Jan 2004

Techniques For Assessing And Improving Performance In Navigation And Wayfinding Using Mobile Augmented Reality, Brian Goldiez

Electronic Theses and Dissertations

Augmented reality is a field of technology in which the real world is overlaid with additional information from a computer generated display. Enhancements to augmented reality technology presently support limited mobility which is expected to increase in the future to provide much greater real world functionality. This work reports on a set of experiments that investigate performance in search and rescue navigating tasks using augmented reality. Augmentation consisted of a spatially and temporally registered map of a maze that was overlaid onto a real world maze. Participants were required to traverse the maze, answer spatially oriented questions in the maze, …


Hydrogen Sulfide Flux Measurements And Dispersion Modeling From Constr, Sangho Eun Jan 2004

Hydrogen Sulfide Flux Measurements And Dispersion Modeling From Constr, Sangho Eun

Electronic Theses and Dissertations

Odor problems are a common complaint from residents living near landfills. Many compounds can cause malodorous conditions. However, hydrogen sulfide (h2s) has been identified as a principal odorous component from construction and demolition (c&d)debris landfills. Although several studies have reported the ambient concentrations of h2s near c&d landfills, few studies have quantified emission rates of h2s. The most widely used and proven technique for measuring gas emission rates from landfills is the flux chamber method. Typically the flux chamber is a cylindrical enclosure device with a spherical top which limits the gas emission area. Pure zero grade air is introduced …


Analysis Of Type And Severity Of Traffic Crashes At Signalized Intersections Using Tree-Based Regression And Ordered Probit Models, Joanne Marie Keller Jan 2004

Analysis Of Type And Severity Of Traffic Crashes At Signalized Intersections Using Tree-Based Regression And Ordered Probit Models, Joanne Marie Keller

Electronic Theses and Dissertations

Many studies have shown that intersections are among the most dangerous locations of a roadway network. Therefore, there is a need to understand the factors that contribute to traffic crashes at such locations. One approach is to model crash occurrences based on configuration, geometric characteristics and traffic. Instead of combining all variables and crash types to create a single statistical model, this analysis created several models that address the different factors that affect crashes, by type of collision as well as injury level, at signalized intersections. The first objective was to determine if there is a difference between important variables …


Expression Morphing Between Different Orientations, Tao Fu Jan 2004

Expression Morphing Between Different Orientations, Tao Fu

Electronic Theses and Dissertations

How to generate new views based on given reference images has been an important and interesting topic in the area of image-based rendering. Two important algorithms that can be used are field morphing and view morphing. Field morphing, which is an algorithm of image morphing, generates new views based on two reference images which were taken at the same viewpoint. The most successful result of field morphing is morphing from one person's face to the other one's face. View morphing, which is an algorithm of view synthesis, generates in between views based on two reference views which were taken at …


Investigation Of Ground Penetrating Radar For Detection Of Leaking Pipelines Under Roadway Pavements And Development Of Fiber-Wrapping Repair Technique, Pedro F. Suarez Jan 2004

Investigation Of Ground Penetrating Radar For Detection Of Leaking Pipelines Under Roadway Pavements And Development Of Fiber-Wrapping Repair Technique, Pedro F. Suarez

Electronic Theses and Dissertations

Nowadays, it has become a common practice to observe urban roadways undergo severe distress characterized by substantial depressions. In some cases, these pavement depressions are caused by leakages in the connecting joints of sewage pipelines laid beneath the roadway pavement. Manual inspection of pipe leakages has become costly and complex since sewage pipes with relative small diameters do not allow inspection from inside and digging may be required. On the other hand, pipes with large diameters, in which inspection can be made from pipe interior, inspector can not remain inside of the pipe for long periods of time because of …


Planar Magnetics Design For Low-Voltage Dc-Dc Converters, Shangyang Xiao Jan 2004

Planar Magnetics Design For Low-Voltage Dc-Dc Converters, Shangyang Xiao

Electronic Theses and Dissertations

The objectives of this thesis are to design planar magnetic devices based on accurate electromagnetic analysis and miniaturize magnetics within desired low profile as well as small footprint. A novel methodology based on FEM simulation is proposed. By introducing Maxwell 2D simulator, optimal interleaving structures can be found to reduce AC losses that cannot otherwise be accounted for by conventional method. And 3D simulator is employed to make the results more realistic. Thus, high-efficiency high-power density magnetics is achieved.


Modeling Of Membrane Solute Mass Transfer In Ro/Nf Membrane Systems, Yu Zhao Jan 2004

Modeling Of Membrane Solute Mass Transfer In Ro/Nf Membrane Systems, Yu Zhao

Electronic Theses and Dissertations

Five articles describing the impact of surface characteristics, and development of mass transfer models for diffusion controlled membrane applications are published in this dissertation. Article 1 (Chapter 3) describes the impact of membrane surface characteristics and NOM on membrane performance for varying pretreatment and membranes during a field study. Surface charge, hydrophobicity and roughness varied significantly among the four membranes used in the study. Membrane surface characteristics, NOM and SUVA measurements were used to describe mass transfer in a low pressure RO integrated membrane system. Inorganic and organic solute and water mass transfer coefficients were systematically investigated for dependence on …


Biostability In Drinking Water Distribution Systems Study At Pilot-Scale, Michael Le Puil Jan 2004

Biostability In Drinking Water Distribution Systems Study At Pilot-Scale, Michael Le Puil

Electronic Theses and Dissertations

Biostability and related issues (e.g. nitrification) were investigated for 18 months in 18 pilot distribution systems, under various water quality scenarios. This study specifically investigated the impact of steady-state water changes on HPC levels in chlorinated and chloraminated distribution systems. Chlorination was more effective than chloramination in reducing HPC levels (1-2 log difference). There was a rapid increase in HPC corresponding to the change in steady-state water quality, which was observed in all PDS. Modeling effort demonstrated that HPC levels reached a maximum within five days after water quality change and return to initial level ten days after the change. …


Effects Of The Soil Properties On The Maximum Dry Density Obtained Fro, Andres Arvelo Jan 2004

Effects Of The Soil Properties On The Maximum Dry Density Obtained Fro, Andres Arvelo

Electronic Theses and Dissertations

In the construction of highways, airports, and other structures, the compaction of soils is needed to improve its strength. In 1933 Proctor developed a laboratory compaction test to determine the maximum dry density of compacted soils, which can be used for specifications of field compaction. The Compaction of soils is influenced by many factors, the most common are the moisture content, the soil type and the applied compaction energy. The objective of this research is the analysis of the maximum dry density values based on the soil classification and characterization. The method of choice in the determination of the maximum …