Repeatability Of In Vivo Parafoveal Cone Density And Spacing Measurements, Robert Garrioch, Christopher S. Langlo, Adam M. Dubis, Robert F. Cooper, Alfredo Dubra, Joseph Carroll May 2012

Repeatability Of In Vivo Parafoveal Cone Density And Spacing Measurements, Robert Garrioch, Christopher S. Langlo, Adam M. Dubis, Robert F. Cooper, Alfredo Dubra, Joseph Carroll

Biomedical Engineering Faculty Research and Publications

Purpose. To assess the repeatability and measurement error associated with cone density and nearest neighbor distance (NND) estimates in images of the parafoveal cone mosaic obtained with an adaptive optics scanning light ophthalmoscope (AOSLO).

Methods. Twenty-one participants with no known ocular pathology were recruited. Four retinal locations, approximately 0.65[degrees] eccentricity from the center of fixation, were imaged 10 times in randomized order with an AOSLO. Cone coordinates in each image were identified using an automated algorithm (with or without manual correction) from which cone density and NND were calculated. Owing to naturally occurring fixational instability, the 10 images recorded from …


Within-Subject Joint Independent Component Analysis Of Simultaneous Fmri/Erp In An Auditory Oddball Paradigm, Jain Mangalathu-Arumana, Scott A. Beardsley, E. Liebenthal May 2012

Within-Subject Joint Independent Component Analysis Of Simultaneous Fmri/Erp In An Auditory Oddball Paradigm, Jain Mangalathu-Arumana, Scott A. Beardsley, E. Liebenthal

Biomedical Engineering Faculty Research and Publications

The integration of event-related potential (ERP) and functional magnetic resonance imaging (fMRI) can contribute to characterizing neural networks with high temporal and spatial resolution. This research aimed to determine the sensitivity and limitations of applying joint independent component analysis (jICA) within-subjects, for ERP and fMRI data collected simultaneously in a parametric auditory frequency oddball paradigm. In a group of 20 subjects, an increase in ERP peak amplitude ranging 1–8 μV in the time window of the P300 (350–700 ms), and a correlated increase in fMRI signal in a network of regions including the right superior temporal and supramarginal gyri, was …


Robotic Resistance Treadmill Training Improves Locomotor Function In Human Spinal Cord Injury: A Pilot Study, Ming Wu, Jill M. Landry, Brian D. Schmit, T. George Hornby, Sheng-Che Yen May 2012

Robotic Resistance Treadmill Training Improves Locomotor Function In Human Spinal Cord Injury: A Pilot Study, Ming Wu, Jill M. Landry, Brian D. Schmit, T. George Hornby, Sheng-Che Yen

Biomedical Engineering Faculty Research and Publications

Objective

To determine whether cable-driven robotic resistance treadmill training can improve locomotor function in humans with incomplete spinal cord injury (SCI).

Design

Repeated assessment of the same patients with crossover design.

Setting

Research units of rehabilitation hospitals in Chicago.

Participants

Patients with chronic incomplete SCI (N=10) were recruited to participate in this study.

Interventions

Subjects were randomly assigned to 1 of 2 groups. One group received 4 weeks of assistance training followed by 4 weeks of resistance training, while the other group received 4 weeks of resistance training followed by 4 weeks of assistance training. Locomotor training was provided by …


Effects Of Different Microenvironmental Conditions On The Growth And Differentiation Of Dental Pulp Stem Cells, Matthew Cupelli May 2012

Effects Of Different Microenvironmental Conditions On The Growth And Differentiation Of Dental Pulp Stem Cells, Matthew Cupelli

All Theses

Human teeth are very complex structures that are susceptible to many different pathologies due to poor dental health. Currently, there are many restorative methods to reestablish some of the function that teeth have, but the materials used in these methods all have drawbacks and cannot fully mimic the native teeth. Tissue engineering research groups have begun to explore regenerating bone or dental tissue using mesenchymal stem cells derived from the bone marrow. However, our group focuses on regenerating dental tissues using multipotent stem cells from dental pulp.
Dental pulp stem cells (DPSCs) have shown similarities to bone marrow stem cells …


Electrochemical Capacitance Measurements To Study Molecular Surface Interactions, Nrutya Madduri May 2012

Electrochemical Capacitance Measurements To Study Molecular Surface Interactions, Nrutya Madduri

All Theses

The behavior of biological molecules such as proteins at the electrode/electrolyte has been of considerable interest for the development of biosensors. Several investigative techniques including Potentiometry, Voltammetry, Amperometry, and Electrochemical Impedance Spectroscopy are being employed to study and analyze these molecular surface interactions. Investigative techniques such as cyclic voltammetry involve the application of a large potential to probe the electrode characteristics and capture the bulk membranous events to obtain the required measurements. This study looks to achieve two major objectives through the use of a novel technique, namely, the double layer capacitive method: 1) to analyze the electrochemical behavior of …


Design And Implementation Of A Shoulder Simulator, Chelsea Lynn Kowal May 2012

Design And Implementation Of A Shoulder Simulator, Chelsea Lynn Kowal

Renée Crown University Honors Thesis Projects - All

The main objective of this thesis project is to build a shoulder simulator to be able to understand the mechanics of the shoulder, specifically the rotator cuff and deltoid muscles. The shoulder simulator should be able to mimic the important motions of the human shoulder by pulling on tendons of cadaver shoulders and moving the shoulder in various specified motions. In my thesis project, I worked on creating a shoulder simulator that would control the rotator cuff muscles along with the three deltoid muscles. In order to do this, I needed to design and test the shoulder simulator using cadaver …


Escherichia Coli Hm22 Biofilm Viability When In Contact With Implant-Grade, Titanium-6aluminum-4-Vanadium Alloy Under Varied Electrochemical Conditions, Alexander Ross Weiss May 2012

Escherichia Coli Hm22 Biofilm Viability When In Contact With Implant-Grade, Titanium-6aluminum-4-Vanadium Alloy Under Varied Electrochemical Conditions, Alexander Ross Weiss

Renée Crown University Honors Thesis Projects - All

No abstract provided.


Simulation Of Lower Limb Axial Arterial Length Change During Locomotion, Melissa D. Young, Matthew C. Streicher, Richard J. Beck, Antonie J. Van Den Bogert, Azita Tajaddini, Brian L. Davis May 2012

Simulation Of Lower Limb Axial Arterial Length Change During Locomotion, Melissa D. Young, Matthew C. Streicher, Richard J. Beck, Antonie J. Van Den Bogert, Azita Tajaddini, Brian L. Davis

Mechanical Engineering Faculty Publications

The effect of external forces on axial arterial wall mechanics has conventionally been regarded as secondary to hemodynamic influences. However, arteries are similar to muscles in terms of the manner in which they traverse joints, and their three-dimensional geometrical requirements for joint motion. This study considers axial arterial shortening and elongation due to motion of the lower extremity during gait, ascending stairs, and sitting-to-standing motion. Arterial length change was simulated by means of a graphics based anatomic and kinematic model of the lower extremity. This model estimated the axial shortening to be as much as 23% for the femoropopliteal arterial …


The Use Of A Pylon Mounted Transducer For Investigating The Gait Of Transtibial Amputees, Justin Robert Brink May 2012

The Use Of A Pylon Mounted Transducer For Investigating The Gait Of Transtibial Amputees, Justin Robert Brink

UNLV Theses, Dissertations, Professional Papers, and Capstones

Two areas of research interest in the design and use of lower limb prosthetic devices are how foot performance varies with design and how prosthesis alignment affects gait. The current study addressed both of these areas through the use of the JR3 triaxial transducer mounted at the base of the socket. The transducer is an innovative form of instrumentation that measures forces and moments at the end of the socket. Traditional measurement of gait uses a force plate buried in the floor of a gait laboratory. The study established that the transducer offers a viable means of instrumentation for amputee …


Fluidized-Bed Gasification Of Dairy Manure By Box–Behnken Design, Hanjing Wu, Milford A. Hanna, David D. Jones May 2012

Fluidized-Bed Gasification Of Dairy Manure By Box–Behnken Design, Hanjing Wu, Milford A. Hanna, David D. Jones

Department of Agricultural and Biological Systems Engineering: Faculty Publications

Application of excessive animal manure to the land may cause some environmental problems such as eutrophication of surface waters, degradation of ground water quality, and threats to human health. This paper reports an experimental study on the technology of biomass gasification to treat animal waste by analyzing the effects of key operating parameters on gasification. In this research, dairy manure from the University of Nebraska dairy farm was first collected and dried, and then gasified in a fluidized-bed, laboratory-scale gasifier to generate syngas. The effects of three parameters, namely temperature, steam to biomass ratio (SBR) and the equivalence ratio (ER), …


Engineering Design Of A Prototype Ammonia Absorption Tower, Andrew Warren Calogero May 2012

Engineering Design Of A Prototype Ammonia Absorption Tower, Andrew Warren Calogero

Honors Capstones

No abstract provided.


Even Moderate Visual Impairments Degrade Drivers' Ability To See Pedestrians At Night, Joanne M. Wood, Richard A. Tyrell, Alex Chaparro, Ralph P. Marszalek, Trent P. Carberry, Byoung Sun Chu May 2012

Even Moderate Visual Impairments Degrade Drivers' Ability To See Pedestrians At Night, Joanne M. Wood, Richard A. Tyrell, Alex Chaparro, Ralph P. Marszalek, Trent P. Carberry, Byoung Sun Chu

Publications

PURPOSE. To determine the effect of moderate levels of refractive blur and simulated cataracts on nighttime pedestrian conspicuity in the presence and absence of headlamp glare.

METHODS. The ability to recognize pedestrians at night was measured in 28 young adults (M ¼ 27.6 years) under three visual conditions: normal vision, refractive blur, and simulated cataracts; mean acuity was 20/40 or better in all conditions. Pedestrian recognition distances were recorded while participants drove an instrumented vehicle along a closed road course at night. Pedestrians wore one of three clothing conditions and oncoming headlamps were present for 16 participants and absent for …


Novel Phantoms And Post-Processing For Diffusion Spectrum Imaging, Vaibhav Juneja May 2012

Novel Phantoms And Post-Processing For Diffusion Spectrum Imaging, Vaibhav Juneja

Dissertations and Theses (Open Access)

High Angular Resolution Diffusion Imaging (HARDI) techniques, including Diffusion Spectrum Imaging (DSI), have been proposed to resolve crossing and other complex fiber architecture in the human brain white matter. In these methods, directional information of diffusion is inferred from the peaks in the orientation distribution function (ODF). Extensive studies using histology on macaque brain, cat cerebellum, rat hippocampus and optic tracts, and bovine tongue are qualitatively in agreement with the DSI-derived ODFs and tractography. However, there are only two studies in the literature which validated the DSI results using physical phantoms and both these studies were not performed on a …


Development Of A Lower Extremity Mobility Assessment Methodology For Motor Vehicle Operation And Initial Validation, Justin Arnosky May 2012

Development Of A Lower Extremity Mobility Assessment Methodology For Motor Vehicle Operation And Initial Validation, Justin Arnosky

All Theses

Limited quantifiable data exists on lower extremity mobility and function during driving. To date, the most appropriate existing measures of successful driving function are assessed by a driving rehabilitation specialist during an on-road evaluation. Establishing the kinematic chain- or the order and magnitude in which joints are moved- during driving may prove to be a useful tool in lower extremity function assessment in drivers. To this end, a study was conducted instrumenting both the left and right legs of healthy licensed male drivers (18-26 years old) with a system of angle measuring goniometers (Biometrics, Ltd.) in a driving simulator (DriveSafety …


Mechanical Properties Of Bone Due To Sost Expression: A 3-Point Bending Assessment Of Murine Femurs, Kainoa John Peterson May 2012

Mechanical Properties Of Bone Due To Sost Expression: A 3-Point Bending Assessment Of Murine Femurs, Kainoa John Peterson

Master's Theses

Sclerostin, a protein coded for by the SOST gene, is an osteocyte-expressed negative regulator of bone formation. The absence of SOST in the genome may have an effect on bone formation both during skeletal maturation and full maturity. This study attempts to determine significant differences in the mechanical properties of bone that expresses SOST compared to bone that does not. One hundred femur samples from 6, 8, and 12 month old mice were obtained from Lawrence Livermore National Labs and loaded until failure using three-point bending. Results showed significant differences in treatment group effects for cross sectional area, yield force, …


Surface Damage In Retrieved Total Knee Replacement Femoral Components, Estefania Alvarez May 2012

Surface Damage In Retrieved Total Knee Replacement Femoral Components, Estefania Alvarez

All Dissertations

The metallic femoral components of total knee replacements are subject to in vivo surface damage and roughening that can severely limit the service lifetime of the bearing system. To date, there are no national standards by which to characterize the severity and damage modes of these critical bearing surfaces, and therefore it remains difficult to accurately assess how femoral damage influences total joint replacement bearing longevity. In vitro and in vivo studies have shown that severe surface damage of the femoral component can occur, however, there is still no defined test methodology that can identify or replicate the types of …


A Refreshable And Portable E-Braille System For The Blind And Visually Impaired, Mohammad Yousef Saadeh May 2012

A Refreshable And Portable E-Braille System For The Blind And Visually Impaired, Mohammad Yousef Saadeh

UNLV Theses, Dissertations, Professional Papers, and Capstones

The objective of this research is to design an affordable Braille tactile display that is wearable, refreshable, and portable. The device is intended to be used as an output device that can playback stored media. It can be also incorporated with current Braille reading technologies. The device will control both the electrical and mechanical stimulations to optimize the sensation and ensure extended use of the device. This work is concerned mainly with the mechanical aspects of the design.

This research proposed the development of a finger-wearable, scanning-style electric stimulation based (electrotactile) Braille display with sensing and adaptive rendering/actuation functions for …


Evaluation Of A Bisphosphonate Enriched Ultra-High Molecular Weight Polyethylene For Enhanced Total Joint Replacement Bearing Surface Functionality, Cassandra Wright-Walker May 2012

Evaluation Of A Bisphosphonate Enriched Ultra-High Molecular Weight Polyethylene For Enhanced Total Joint Replacement Bearing Surface Functionality, Cassandra Wright-Walker

All Dissertations

Each year in the United States there is an increasing trend of patients receiving total joint replacement (TJR) procedures. Approximately a half million total knee replacements (TKRs) are performed annually in the United States with increasing prevalence attributed to baby-boomers, obesity, older, and younger patients. This trend is also seen for total hip replacements (THRs) as well. The use of ultra high molecular weight polyethylene (UHMWPE) inserts in TJRs results in wear particle-induced osteolysis, which is the predominant cause for prosthesis failure and revision surgery. Sub-micron size particle generation is inevitable despite the numerous efforts in improving this bearing material. …


Quantitative, Spatial Imaging Based Measurements To Assess Cellular Health And Oxygenation In A Tissue Engineered Test System, Erik Bland May 2012

Quantitative, Spatial Imaging Based Measurements To Assess Cellular Health And Oxygenation In A Tissue Engineered Test System, Erik Bland

All Dissertations

Three-dimensional in vitro tissue test systems are employed to examine cell behavior, test responses to drugs and vaccines, and answer basic biological questions. These systems are more physiologically relevant than two-dimensional cell cultures, and are more relevant, easier and less expensive to maintain than animal models. However, methods used to measure cell behavior and viability have been developed specifically for two-dimensional cell cultures or animal models, and are often not optimally translated to three-dimensional in vitro test systems. The purpose of this work was to aid in the development of three-dimensional, spatially controlled in vitro test systems, and to develop …


Assembly And Disassembly Of Myofibrils In Dissociated Cardiomyocytes, Honghai Liu May 2012

Assembly And Disassembly Of Myofibrils In Dissociated Cardiomyocytes, Honghai Liu

All Dissertations

Significance
1) We have developed a hybrid TPEF-SHG imaging system with an onstage incubator for long-term living-cell imaging. Using the imaging system, the assembly of myosin filaments onto the myofibrils can be investigated without fluorescently labeling the specific proteins, which enabled us to study the dynamic process of the assembly and dedifferentiation of myofibrils in living cardiomyocytes without labeling any sarcomeric proteins for long time.
2) We observed the addition of new sarcomeres during myofibrillogenesis while neonatal cardiomyocytes were spreading on the substrate for up to 10 hours under the customized TPEF-SHG imaging system. New-sarcomere addition at both the ends …


Nanopillar Based Electrochemical Biosensor For Monitoring Microfluidic Based Cell Culture, Rajan Gangadharan May 2012

Nanopillar Based Electrochemical Biosensor For Monitoring Microfluidic Based Cell Culture, Rajan Gangadharan

All Dissertations

In-vitro assays using cultured cells have been widely performed for studying many aspects of cell biology and cell physiology. These assays also form the basis of cell based sensing. Presently, analysis procedures on cell cultures are done using techniques that are not integrated with the cell culture system. This approach makes continuous and real-time in-vitro measurements difficult. It is well known that the availability of continuous online measurements for extended periods of time will help provide a better understanding and will give better insight into cell physiological events.
With this motivation we developed a highly sensitive, selective and stable microfluidic …


Development Of A Microfluidic Device Coupled To Microdialysis Sampling For The Pre-Concentration Of Cytokines, Randy Francisco Espinal Cabrera May 2012

Development Of A Microfluidic Device Coupled To Microdialysis Sampling For The Pre-Concentration Of Cytokines, Randy Francisco Espinal Cabrera

Graduate Theses and Dissertations

A proof-of-concept microfluidic device combined with heparin-immobilized magnetic beads was created to concentrate cytokine proteins collected from microdialysis samples. Cytokines are known to be related to several diseases such as cancer, and Parkinson's diseases, so to be able to develop more effective diseases treatments their interactions have to be well understood. Amine-functionalized polystyrene and carboxyl-functionalized magnetic microspheres of ~6.0 ìm in diameter were used to immobilize heparin. The amount of heparin immobilized on polystyrene beads was 5.82 x 10-8 ± 0.36 x 10-8 M per 1.0 x 106 beads and for magnetic beads was 0.64 x 10-8 ± 0.01 x …


Aptamer-Based Spr Biosensor For Detection Of Avian Influenza Virus, Hua Bai May 2012

Aptamer-Based Spr Biosensor For Detection Of Avian Influenza Virus, Hua Bai

Graduate Theses and Dissertations

Rapid and specific detection of avian influenza (AI) virus is urgently needed with the concerns over the outbreaks of highly pathogenic H5N1 avian influenza in animal and human infection. Aptamers are artificial oligonucleic acid that can specifically bind to target molecules. They show comparable affinity for target virus and better thermal stability than monoclonal antibodies. Those advantages make aptamers promising candidates in diagnostic and detection applications. The goal of this research was to use DNA&ndashaptamer as the specific recognition element in a portable surface plasmon resonance (SPR) biosensor for detection of AI H5N1 virus in poultry.

A SPR biosensor was …


Electrospun Polycaprolactone Nanofiber Scaffolds For Tissue Engineering, Andreas Haukas May 2012

Electrospun Polycaprolactone Nanofiber Scaffolds For Tissue Engineering, Andreas Haukas

Graduate Theses and Dissertations

Stem cell and tissue engineering offer us with a unique opportunity to research and develop new therapies for treating various diseases that are otherwise incurable using traditional medicines. However, development of these new therapies replies upon the establishment of in vitro cell culture and differentiation systems that mimic in vivo microenvironments required for cell-cell and cell-ECM interaction. The development of these cell culture systems depends upon the identification of appropriate biomaterials and cell sources. Biomaterials should be carefully selected and fabricated into scaffolds for supporting cell growth and differentiation. In this study, we explored the fabrication of 3D electrospun nanofiber …


Bioengineering Approach To Understanding Tmj Pathobiology, Jonathan Kuo May 2012

Bioengineering Approach To Understanding Tmj Pathobiology, Jonathan Kuo

All Dissertations

The temporomandibular joint (TMJ) is a load-bearing joint consisting of the condyle of the mandibular bone, the fossa eminence of the temporal bone, and a fibrocartilaginous disc held in between the bone surfaces by ligaments. The TMJ disc serves to distribute stress, lubricate movement, and protect the articular surfaces of the joint. Over ten million Americans suffer from TMJ disorders (TMD) that affect the movement and function of the joint, making everyday tasks like talking and eating difficult and painful. A wide variety of treatments and surgeries have been proposed and undertaken with limited success based on the varying degree …


Engineering Of Polyamidoamine (Pamam) Dendrimers For Gene And Drug Delivery, Quan Yuan Apr 2012

Engineering Of Polyamidoamine (Pamam) Dendrimers For Gene And Drug Delivery, Quan Yuan

Theses and Dissertations

Dendrimers are a class of polymers with a highly branched, three-dimensional architecture composed of an initiator core, several interior layers of repeating units and multiple surface groups. They have been recognized as the most versatile compositionally and structurally controlled nanoscale building blocks throughout the fields of engineering, materials science, chemistry, and biology, and they have been widely investigated for drug and gene delivery. Polyamidoamine (PAMAM) dendrimers have inherent properties for gene delivery because of their high buffering capacity, polycationic surface and numerous surface groups for biofunctionlization. This dissertation is organized into four independent sections. The first section investigates a series …


Electrical & Magnetic Stimulation And Health, Yiyan Li Apr 2012

Electrical & Magnetic Stimulation And Health, Yiyan Li

College of Engineering: Graduate Celebration Programs

1, Introduction Most of the patients with neural diseases such as Parkinson’s disease, Stroke and Depression, cannot be cured by taking pills or conducting surgery. In contrast to the conventional therapies, physical therapies such as TMS (transcranial magnetic stimulation) (Fig. 1) and tDCS (transcranial direct current stimulation) (Fig. 2) are the most popular methods in treating neural disorders with a non-invasive way. TMS employs electromagnetic (1-3 Tesla) induction generates an Electric field suitable for neural stimulation; tDCS employs a weak current (1-2 mA) to modulate neuronal excitabilities.


Real-Time Face Detection And Recognition, Parker Hill, Brendan Morris Apr 2012

Real-Time Face Detection And Recognition, Parker Hill, Brendan Morris

College of Engineering: Graduate Celebration Programs

The face has become a popular biometric for identification due to the wide range of features and difficulty in manipulation of the metric. In order to work towards a robust facial recognition system, this work contains a foundation for using the face as a recognition metric. First, faces are detected from still images using a Viola-Jones object detection algorithm. Then, Eigenfaces is applied to the detected faces. The system was tested on face databases as well as real-time feed from a web camera.


Synthesis And Characterization Of Doxorubicin Carrying Cetuximab-Pamam Dendrimer Bioconjugates, Gunjan Saxena Apr 2012

Synthesis And Characterization Of Doxorubicin Carrying Cetuximab-Pamam Dendrimer Bioconjugates, Gunjan Saxena

Theses and Dissertations

A tumor targeted dendrimer based drug delivery system was designed and synthesized to carry chemotherapy drug doxorubicin. Polyamidoamine (PAMAM) dendrimer G4.5 was chosen as the underlying carrier. Anionic G4.5 is a good option for drug delivery as it consists of 128 surface groups, is less cytotoxic and favorably biodistributed. The delivery system was synthesized using a layer-by layer arrangement of three functional entities: chemotherapy drug doxorubicin, monoclonal antibody Cetuximab against EGF receptor, and polyethylene glycol (PEG). Doxorubicin was attached via an acid-sensitive hydrazon linkage to the dendrimer. Macromolecules are taken in by cells through endocytosis. pH inside the early endosomes …


Semi-Interpenetrating Nanofiber Scaffolds For Transbuccal Drug Delivery, Donald Aduba Jr. Apr 2012

Semi-Interpenetrating Nanofiber Scaffolds For Transbuccal Drug Delivery, Donald Aduba Jr.

Theses and Dissertations

The oral buccal mucosa is a promising absorption site for drug administration because it is permeable, highly vascularized and allows ease of administration. Although there are many platforms that have been used for drug delivery, nanofiber scaffolds as a platform for local or systemic drug delivery through the oral mucosa have not been fully explored. In this thesis, we fabricated a biocompatible electrospun gelatin nanofiber scaffold for local drug delivery at the oral mucosa. To stabilize the electrospun gelatin nanofibers and allow non-invasive incorporation of therapeutics into the scaffold, photo-reactive polyethylene-glycol (PEG)-diacrylate was employed to crosslink the scaffold to form …