Open Access. Powered by Scholars. Published by Universities.®

Engineering Commons™

Open Access. Powered by Scholars. Published by Universities.®

Biomedical Engineering and Bioengineering

Institution
Keyword
Publication Year
Publication
Publication Type
File Type

Articles 8401 - 8430 of 11465

Full-Text Articles in Engineering

Challenges In Development Of An Anti-Idiotypic Cancer Vaccine, Adolfo Castillo May 2012

Challenges In Development Of An Anti-Idiotypic Cancer Vaccine, Adolfo Castillo

Vaccine Technology IV

No abstract provided.


The Role Of Public-Private Partnerships In Advancing Vaccine Technologies And Improving Vaccine Effectiveness And Delivery For Developing Countries, Ray Cummings May 2012

The Role Of Public-Private Partnerships In Advancing Vaccine Technologies And Improving Vaccine Effectiveness And Delivery For Developing Countries, Ray Cummings

Vaccine Technology IV

No abstract provided.


Challenges In Batch Production Of Malaria Vaccines, Nicolas Havelange May 2012

Challenges In Batch Production Of Malaria Vaccines, Nicolas Havelange

Vaccine Technology IV

No abstract provided.


Establishing Human Vaccine Manufacturing In Southern Africa, Morena Makhoana May 2012

Establishing Human Vaccine Manufacturing In Southern Africa, Morena Makhoana

Vaccine Technology IV

No abstract provided.


Rational Design Of A Fully Synthetic Nanoparticle-Based Vaccine For Smoking Cessatio, Takashi Kishimoto May 2012

Rational Design Of A Fully Synthetic Nanoparticle-Based Vaccine For Smoking Cessatio, Takashi Kishimoto

Vaccine Technology IV

No abstract provided.


Recombinant Vlp Based Human Vaccines For Emerging Markets, Qinjian Zhao May 2012

Recombinant Vlp Based Human Vaccines For Emerging Markets, Qinjian Zhao

Vaccine Technology IV

No abstract provided.


111 Years Producing Immunobiologicals: New Challenges, Jorge Kalil May 2012

111 Years Producing Immunobiologicals: New Challenges, Jorge Kalil

Vaccine Technology IV

No abstract provided.


Development Of A Vaccine Against Clostridium Difficile Infection (Cdi): Design, Purification, And Biological Activities Of The Recombinant Toxin 1 Antigens, Jerzy Karczewski May 2012

Development Of A Vaccine Against Clostridium Difficile Infection (Cdi): Design, Purification, And Biological Activities Of The Recombinant Toxin 1 Antigens, Jerzy Karczewski

Vaccine Technology IV

No abstract provided.


Recombinant Influenza Vaccine, Manon Cox May 2012

Recombinant Influenza Vaccine, Manon Cox

Vaccine Technology IV

No abstract provided.


Computational Design And Characterization Of A Temperature-Sensitive Plasmid Replicon For Gram Positive Thermophiles, Daniel G. Olson, Lee R. Lynd May 2012

Computational Design And Characterization Of A Temperature-Sensitive Plasmid Replicon For Gram Positive Thermophiles, Daniel G. Olson, Lee R. Lynd

Dartmouth Scholarship

Temperature-sensitive (Ts) plasmids are useful tools for genetic engineering, but there are currently none compatible with the gram positive, thermophilic, obligate anaerobe, Clostridium thermocellum. Traditional mutagenesis techniques yield Ts mutants at a low frequency, and therefore requires the development of high-throughput screening protocols, which are also not available for this organism. Recently there has been progress in the development of computer algorithms which can predict Ts mutations. Most plasmids currently used for genetic modification of C. thermocellum are based on the replicon of plasmid pNW33N, which replicates using the RepB replication protein. To address this problem, we set out …


Development Of A Multiple Contact Haptic Display With Texture-Enhanced Graphics, David Burch May 2012

Development Of A Multiple Contact Haptic Display With Texture-Enhanced Graphics, David Burch

Theses and Dissertations

This dissertation presents work towards the development of a multiple finger, worn, dynamic display device, which utilizes a method of texture encoded information to haptically render graphical images for individuals who are blind or visually impaired. The device interacts directly with the computer screen, using the colors and patterns displayed by the image as a means to encode complex patterns of vibrotactile output, generating the texture feedback to render the image. In turn, the texture feedback was methodically designed to enable parallel processing of certain coarse information, speeding up the exploration of the diagram and improving user performance. The design …


Optimization Of Feature Selection In A Brain-Computer Interface Switch Based On Event-Related Desynchronization And Synchronization Detected By Eeg, Mason Montgomery May 2012

Optimization Of Feature Selection In A Brain-Computer Interface Switch Based On Event-Related Desynchronization And Synchronization Detected By Eeg, Mason Montgomery

Theses and Dissertations

There are hundreds of thousands of people who could benefit from a Brain-Computer Interface. However, not all are willing to undergo surgery, so an EEG is the prime candidate for use as a BCI. The features of Event-Related Desynchronization and Synchronization could be used for a switch and have been in the past. A new method of feature selection was proposed to optimize classification of active motor movement vs a non-active idle state. The previous method had pre-selected which frequency and electrode to use as electrode C3 at the 20Hz bin. The new method used SPSS statistical software to determine …


Finite Element Analysis Of Transverse Medial Malleolar Fracture Fixation, Ruchi Chande May 2012

Finite Element Analysis Of Transverse Medial Malleolar Fracture Fixation, Ruchi Chande

Theses and Dissertations

Injury to the medial malleolus, the distal end of the tibia and one of the bones comprising the ankle joint, can occur in various loading scenarios. Open reduction/internal fixation (ORIF) to reattach the malleolar fragment to the proximal tibia can be achieved via various devices, however small fragments are particularly challenging to treat. In this study, computational finite element analysis (FEA) was utilized to investigate the fixation of transverse medial malleolar fractures by two cancellous screws or by a new fixation device, the Medial Malleolar Sled™. Cadaveric testing assessed the performance of the two constructs in both tension and torsion. …


Current Trends Of Fmri In Vision Science: A Review, Nasser H. Kashou May 2012

Current Trends Of Fmri In Vision Science: A Review, Nasser H. Kashou

Biomedical, Industrial & Human Factors Engineering Faculty Publications

Studying brain functional activities is an area that is experiencing rapid interest in the field of neuroimaging. Functional magnetic resonance imaging (fMRI) has provided vision science researchers a powerful and noninvasive tool to understand eye function and correlate it with brain activities. In this chapter, we focus on the physiological aspects followed by a literature review. More specifically, to motivate and appreciate the complexity of the visual system, we will begin with a description of specific stages the visual pathway, beginning from the distal stimulus and ending in the visual cortex. More importantly, the development of ascending visual pathway will …


Brain Controlled Switch, Dimple Bhuta May 2012

Brain Controlled Switch, Dimple Bhuta

Theses and Dissertations

This study aims at designing and implementing a single channel stand-alone Brain-Controlled Switch (BCS) device, which records the electroencephalography (EEG) signals from the scalp using electrodes, amplifies it, eliminates interferences (associated with the EEG signals) and processes the EEG signals to extract and decode temporal signal features to determine user’s intention of regulating an external switch. The design of our “brain-controlled switch” device is implemented using a bio-potential amplifier and a microcontroller. The bio-potential amplifier amplifies the EEG signals to a level sufficient for processing, eliminates interferences and ensures patient safety. The microcontroller (dsPIC30F4013) digitizes the amplified and conditioned analog …


Improved Tissue Caliper, Kenneth Ted-Luck Hung May 2012

Improved Tissue Caliper, Kenneth Ted-Luck Hung

Honors Scholar Theses

My honors thesis will be covering the work that I am doing for my senior design project. My senior design project involves building a tissue caliper for medical device company, Covidien. During medical research and development it is often necessary to measure and document the thickness of tissue samples and media (simulated tissue foam). A device known as a tissue caliper is currently used to perform such measurements. Our project requires us to design, build, calibrate, and validate an instrument, which will be capable of measuring sample thicknesses ranging from 0.10 to 1.00 inches with an accuracy of ± 0.005 …


Growth And Expression Of Halorhodopsin For Application In A Protein-Based Artificial Retina, Megan Ryan Gillespie May 2012

Growth And Expression Of Halorhodopsin For Application In A Protein-Based Artificial Retina, Megan Ryan Gillespie

Honors Scholar Theses

Halorhodopsin (HR), a light-activated chloride ion pump, demonstrates potential for use as the scaffolding in an artificial retina. Retinal implants are needed to restore vision to people afflicted with ophthalmic diseases, such as age-related macular degeneration (AMD) and retinitis pigmentosa (RP). A protein-based chloride ion-patch would be utilized by the eye to create an influx of chloride ions, similar to ion concentrations in healthy retinas during the conversion of light stimuli to electrochemical signals. This protein-based retinal prosthesis will directly stimulate the bipolar cells of the retina, replacing the function of damaged photoreceptor cells. Other alternative treatments for AMD and …


Electronic Circuit To Mimic The Neural Network For The Saccade Controller, Justin D. Morse May 2012

Electronic Circuit To Mimic The Neural Network For The Saccade Controller, Justin D. Morse

Honors Scholar Theses

The proposed device is an electronic circuit that mimics the neural network controlling fast eye movements, or saccades. The device simulates the signals produced by each neuronal population during the control of a horizontal saccade and allows for observing and recording. It will serve as a valuable teaching tool in the field of neural control. Furthermore, the device will have applications in the realm of diagnosing and properly treating brain injury. Finally, this device could be incorporated into a system for controlling the eye movements of a realistic, artificially intelligent robot.

The FitzHugh-Nagumo model of the action potential is used …


A Stochastic Simulation Model Of Alarm Response Strategies On A Telemetry Floor, Tasneem M. Pishori May 2012

A Stochastic Simulation Model Of Alarm Response Strategies On A Telemetry Floor, Tasneem M. Pishori

Master's Theses

The large quantity of alarms characteristic of clinical settings have resulted in nursing staff suffering from a phenomenon termed ‘alarm fatigue’. Alarm fatigue is desensitization via habituation – as these commonly heard noises cause caregivers to have delayed or no response to alarms. Alarm management was ranked number one on the annual top ten list of technology hazards afflicting healthcare institutions published by the ECRI Institute for 2012. Several patient safety organizations have established alarm fatigue as a priority concern, and are working to eradicate the issue from the healthcare environment by 2017. To better understand the problem, a simplified …


Development And Application Of A Portable System To Reliably Measure Grip Forces Using Thin-Film Force Sensors, Shane Vincent Tornifoglio May 2012

Development And Application Of A Portable System To Reliably Measure Grip Forces Using Thin-Film Force Sensors, Shane Vincent Tornifoglio

Master's Theses

Accurate tracking of hand grip force is an important consideration needed for a robust understanding in the study of human biomechanics. One aspect where it proves useful is in hand-arm vibration, such as from gripping a power tool. Depending on how firmly the user is gripping the tool, they may change their exposure levels to the tool vibration, which can lead to potential disorders such as Hand-Arm Vibration Syndrome (HAVS).

A small, battery powered portable force unit has been developed to supply power to, and condition, the signals from eight thin-film force sensors. This gives a better understanding of the …


A Comprehensive Methodology For Assessing Biomechanical Risks Associated With Hand Tool Use: Applied To Laparoscopic Surgical Instruments, Drew R. Seils May 2012

A Comprehensive Methodology For Assessing Biomechanical Risks Associated With Hand Tool Use: Applied To Laparoscopic Surgical Instruments, Drew R. Seils

Master's Theses

Biomechanical risk factors are physical stressors that act on the neuromuscular structures of the human body and are present in all occupational settings. Repetition and intensity of tasks performed can magnify the effects of the biomechanical risks that a worker is exposed to.

After reviewing the current literature on ergonomics in laparoscopic surgery it was clear that a comprehensive approach to quantitatively reporting on the biomechanical risk factors associated with surgical hand tools had never been performed. Utilizing an opto-electronic motion capture system meant the exact surgeon posture was recorded during simulated surgical tasks. Electromyography was used to evaluate muscle …


Quantification Of Preterm Infant Feeding Coordination: An Algorithmic Approach, Pallavi Ramnarain May 2012

Quantification Of Preterm Infant Feeding Coordination: An Algorithmic Approach, Pallavi Ramnarain

Theses and Dissertations

Oral feeding competency is a primary requirement for preterm infant hospital release. Currently there is no widely accepted method to objectively measure oral feeding. Feeding consists primarily of the integration of three individual feeding events: sucking, breathing, and swallowing, and the objective of feeding coordination is to minimize aspiration. The purpose of this work was to quantify the infant feeding process from signals obtained during bottle feeding and ultimately develop a measure of feeding coordination. Sucking was measured using a pressure transducer embedded within a modified silicone bottle block. Breathing was measured using a thermistor embedded within nasal cannula, and …


In Vivo Immunotoxicological Evaluation Of Electrospun Polycaprolactone (Epcl) And Investigation Of Epcl As A Drug Delivery System For Immunomodulatory Compounds, Colleen Mcloughlin May 2012

In Vivo Immunotoxicological Evaluation Of Electrospun Polycaprolactone (Epcl) And Investigation Of Epcl As A Drug Delivery System For Immunomodulatory Compounds, Colleen Mcloughlin

Theses and Dissertations

Electrospun materials have potential use in many biomedical applications such as soft tissue replacements or as scaffolds to target drug delivery to local sites. Electrospinning is a polymer processing technique that can be used to create materials composed of fibers with diameters ranging from the micron to the nanoscale. We investigated the effects of microfibrous and nanofibrous electrospun polycaprolactone (EPCL) on innate, cell-mediated, and humoral components of the immune system. Results demonstrated that in both young (12 week) and old (6 month) mice, EPCL had no effect on various immune parameters. With its lack of immunotoxicity, EPCL presents an excellent …


Non-Invasive Intracranial Pressure Method And Monitor, Tarun Sinha May 2012

Non-Invasive Intracranial Pressure Method And Monitor, Tarun Sinha

Theses and Dissertations

The eyes are acoustically continuous with the brain and inner ear tissues in regard to matched impedances, based on tissue densities, thus, vibration of one site will be reflected in all sites. With this being the case, the vibrational energy response of the eye due to an external source can be used to determine a correlation or draw a conclusion concerning the vibrational energy response of the brain would be. And since there is a correlation between the vibrational energies, any changes in the acoustical energy in the eye can possibly be used to determine the changes in acoustical energy …


Testing The Efficiency Of Vertically Aligned Gold Nanowires On A Titanium Needle Implantable Neural Electrodes In The Rattus Norvegicus Hippocampus, Lauren Kegley May 2012

Testing The Efficiency Of Vertically Aligned Gold Nanowires On A Titanium Needle Implantable Neural Electrodes In The Rattus Norvegicus Hippocampus, Lauren Kegley

Electrical Engineering Undergraduate Honors Theses

Miniaturized multi-electrode arrays are MEMS devices that have found use as neural prosthetics (Neuro-MEMS). As implants they can interface with neurons as sensors or actuators and help compensate for loss of sensory input, motor control, or cognitive function. The micro-electrodes, studied here, were developed in-house. They have a vertically aligned gold nanowire array and are mounted on a sturdy fine gauge titanium needle. Hence, the bill of materials and design characteristics encourage its use as neural probe. For this study, a probe was tested in vivo for signal acquisition in the hippocampus of a Rattus Norvegicus (Sprague Dawley Rat). Using …


Improving Optical Contact For Functional Near-Infrared Brain Spectroscopy And Imaging With Brush Optodes, Bilal Khan, Chester Wildey, Robert Francis, Fenghua Tian, Mauricio R. Delgado, Hanli Liu, Duncan Macfarlane, George Alexandrakis May 2012

Improving Optical Contact For Functional Near-Infrared Brain Spectroscopy And Imaging With Brush Optodes, Bilal Khan, Chester Wildey, Robert Francis, Fenghua Tian, Mauricio R. Delgado, Hanli Liu, Duncan Macfarlane, George Alexandrakis

Bioengineering Faculty Publications - Archive

A novel brush optode was designed and demonstrated to overcome poor optical contact with the scalp that can occur during functional near infrared spectroscopy (fNIRS) and imaging due to light obstruction by hair. The brush optodes were implemented as an attachment to existing commercial flat-faced (conventional) fiber bundle optodes. The goal was that the brush optodes would thread through hair and improve optical contact on subjects with dense hair. Simulations and experiments were performed to assess the magnitude of these improvements. FNIRS measurements on 17 subjects with varying hair colors (blonde, brown, and black) and hair densities (0–2.96 hairs/mm2 ) …


Sparsity Enhanced Spatial Resolution And Depth Localization In Diffuse Optical Tomography, Venkaiah C. Kavuri, Zi-Jing Lin, Fenghua Tian, Hanli Liu May 2012

Sparsity Enhanced Spatial Resolution And Depth Localization In Diffuse Optical Tomography, Venkaiah C. Kavuri, Zi-Jing Lin, Fenghua Tian, Hanli Liu

Bioengineering Faculty Publications - Archive

No abstract provided.


The Effects Of Coated Gold Nanorods On Porcine Atrioventricular Valve Tissues Using Atomic Force Microscopy, Heather L'Ecuyer May 2012

The Effects Of Coated Gold Nanorods On Porcine Atrioventricular Valve Tissues Using Atomic Force Microscopy, Heather L'Ecuyer

All Theses

In this Master's thesis we examine the effect of surface modified gold nanorods (AuNRs) coated with polyelectrolyte multilayers (PEMs) on the mechanical properties of porcine mitral valve tissue ex vivo. The presence of healthy mitral valve tissue in the body is important to ensuring unidirectional flow of blood through the systemic circuit. Unfortunately, due to its anatomic complexity and unique mechanical behavior, pathological mitral valve tissue remains difficult to treat with conventional methods. We hope that the knowledge gleaned from these studies could be useful for developing new and novel treatments treating pathological mitral valve mechanical properties.
Specifically, we examine …


Silver Coated Bioactive Glass Particles For Wound Healing Applications, A. W. Wren, A. Coughlan, P. Hassanzadeh, Mark R. Towler May 2012

Silver Coated Bioactive Glass Particles For Wound Healing Applications, A. W. Wren, A. Coughlan, P. Hassanzadeh, Mark R. Towler

Chemical and Biochemical Engineering Faculty Research & Creative Works

Bioactive glass particles (0.42SiO2-0.15CaO-0.23Na 2O-0.20ZnO) of varying size (<90 >μm and 425-850 μm) were synthesized and coated with silver (Ag) to produce Ag coated particles (PAg). These were compared against the uncoated analogous particles (Pcon.). Surface area analysis determined that Ag coating of the glass particles resulted in increased the surface area from 2.90 to 9.12 m2/g (90 μm) and 1.09-7.71 m2/g (425-850 μm). Scanning electron microscopy determined that the Ag coating remained at the surface and there was little diffusion through the bulk. Antibacterial (Escherichia coli - 13 mm and Staphylococcus epidermidis …


Improving Health Care Quality And Safety: The Development And Assessment Of Laparoscopic Surgery Instrumentation, Practices And Procedures, Bernadette Mccrory May 2012

Improving Health Care Quality And Safety: The Development And Assessment Of Laparoscopic Surgery Instrumentation, Practices And Procedures, Bernadette Mccrory

Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research

Adverse events due to medical errors are a leading cause of death in the United States exceeding the mortality rates of motor vehicle accidents, breast cancer and AIDS. Improvements can and should be made to reduce the rates of preventable surgical errors since they account for nearly half of all adverse events within hospitals. Although minimally invasive surgery has proven patient benefits such as reduced postoperative pain and hospital stay, its operative environment imposes substantial physical and cognitive strain on the surgeon increasing the risk of error. In order to mitigate errors and protect patients, a multidisciplinary approach was taken …