Full-Text Articles in Engineering

Micro Electrostatic Actuation Of A Silicon Diaphragm, Matthew W. Samples Jun 2015

Micro Electrostatic Actuation Of A Silicon Diaphragm, Matthew W. Samples

Master's Theses

There are a number of applications, from hearing aids to microfluidic pumps, which utilize micro-scale actuating diaphragms. These MEMS (micro-electromechanical system) devices can be actuated by electrostatic forces, which utilize an induced electric field to pull two charged plates towards one another. Such devices were fabricated and electrostatic actuation of the diaphragms was performed to analyze its viability as a micro-speaker. The long-term performance of such products requires adequate diaphragm deflection to create audible pressure waves with relatively low maximum stresses to ensure a high cycle fatigue life. With these requirements, initial calculations and FEA (finite element analysis) were performed …


A Finite Element Analysis On The Viscoelasticity Of Postmenopausal Compact Bone Utilizing A Complex Collagen D-Spacing Model, Austin C. Cummings Jun 2015

A Finite Element Analysis On The Viscoelasticity Of Postmenopausal Compact Bone Utilizing A Complex Collagen D-Spacing Model, Austin C. Cummings

Master's Theses

The nanoscale dimension known as D-spacing describes the staggering of collagen molecules, which are fundamental to the biphasic makeup of bone tissue. This dimension was long assumed to be constant, but recent studies have shown that the periodicity of collagen is variable. Given that the arrangement of collagen molecules is closely related to the degree of bone mineralization, recent studies have begun to look at D-spacing as a potential factor in the ongoing effort to battle postmenopausal osteoporosis. The theoretical models presented by previous studies have only opted to model a single collagen-hydroxyapatite period, so the creation of an intricate …


Characterization Of Two Vernier-Tuned Distributed Bragg Reflector (Vt-Dbr) Lasers Used In Swept Source Optical Coherence Tomography (Ss-Oct), Greg M. Bergdoll Jun 2015

Characterization Of Two Vernier-Tuned Distributed Bragg Reflector (Vt-Dbr) Lasers Used In Swept Source Optical Coherence Tomography (Ss-Oct), Greg M. Bergdoll

Master's Theses

Insight Photonic Solutions Inc. has continued to develop their patented VT-DBR laser design; these wavelength tunable lasers promise marked image-quality and acquisition time improvements in SS-OCT applications.

To be well suited for SS-OCT, tunable lasers must be capable of producing a highly linear wavelength sweep across a tuning range well-matched to the medium being imaged; many different tunable lasers used in SS-OCT are compared to identify the optimal solution.

This work electrically and spectrally characterizes two completely new all-semiconductor VT-DBR designs to compare, as well. The Neptune VT-DBR, an O-band laser, operates around the 1310 nm range and is a …


Development And Validation Of A Tibiofemoral Joint Finite Element Model And Subsequent Gait Analysis Of Intact Acl And Acl Deficient Individuals, Nicholas Czapla Jun 2015

Development And Validation Of A Tibiofemoral Joint Finite Element Model And Subsequent Gait Analysis Of Intact Acl And Acl Deficient Individuals, Nicholas Czapla

Master's Theses

Osteoarthritis (OA) is a degenerative condition of articular cartilage that affects more than 25 million people in the US. Joint injuries, like anterior cruciate ligament (ACL) tears, can lead to OA due to a change in articular cartilage loading. Gait analysis combined with knee joint finite element modeling (FEM) has been used to predict the articular cartilage loading. To predict the change of articular cartilage loading during gait due to various ACL injuries, a tibiofemoral FEM was developed from magnetic resonance images (MRIs) of a 33 year male, with no prior history of knee injuries. The FEM was validated for …


Self-Contained Breathing Apparatus For Firefighter With A Permanent Stoma, Jason Delgadillo, Aaron Wheeler, Zachary Wishbow Jun 2015

Self-Contained Breathing Apparatus For Firefighter With A Permanent Stoma, Jason Delgadillo, Aaron Wheeler, Zachary Wishbow

Biomedical Engineering

The purpose of this project was to create a unique SCBA (self-contained breathing apparatus) for a firefighter named Chris Gauer. This prototype consists of a SCBA headgear connected to a polycarbonate-formed stoma mask with a medical-grade sanitary silicone hose.


Exploration Of Stimulus Current Energy Reduction And Bifurcation Dynamics In Conductance-Based Neuron Models Using Optimal Control Theory, Michael E. Ellinger Jun 2015

Exploration Of Stimulus Current Energy Reduction And Bifurcation Dynamics In Conductance-Based Neuron Models Using Optimal Control Theory, Michael E. Ellinger

Dissertations

Hodgkin-Huxley type conductance-based models can simulate the effect of time-varying injected stimulus currents on the neuron membrane voltage. The dynamics simulated by these model types enables investigation of the biophysical basis of neuronal activity which is fundamental to higher level function. Broadened understanding the basis of nervous system function could lead to development of effective treatment for related diseases, disorders, and the effects of trauma. In this dissertation, optimal control is used with conductance-based neuron models to develop a "Reduced Energy Input Stimulus Discovery Method." Within the method, an objective function balances two competing criteria: tracking a reference membrane voltage …


High Frequency Field Potentials Of The Cerebellar Cortex, Jonathan David Groth May 2015

High Frequency Field Potentials Of The Cerebellar Cortex, Jonathan David Groth

Dissertations

The cerebellum plays a crucial role in motor coordination along with basal ganglia and the motor areas of the cerebral cortex. Both somatosensory and the cerebro-cerebral pathways bring in massive amounts of neural information to the cerebellum. The output of the cerebellar cortex projects to various motor cortices as well as down to the spinal cord to make its contributions to the motor function.

The origin and function of the field potential oscillations in the cerebellum, especially in the high frequencies, have not been explored sufficiently. The primary objective of this study was to investigate the spatio-temporal characteristics of high …


Piezoelectric Scaffolds For Osteochondral Defect Repair, Sita Mahalakshmi Damaraju May 2015

Piezoelectric Scaffolds For Osteochondral Defect Repair, Sita Mahalakshmi Damaraju

Dissertations

Osteoarthritis is one of the most prevalent causes of disability affecting nearly 27 million Americans. Osteoarthritis is caused when extensive damage occurs to the articular cartilage later spreading to the underlying subchondral bone, resulting in osteochondral defects. The current clinical therapies aim at regenerating the hyaline cartilage, but instead fibrocartilage forms at the osteochondral defect site, which is inferior in structure and function and fails to integrate with the surrounding tissue. A biomimetic scaffold, which can provide cues similar to the native extracellular matrix, may facilitate osteochondral defect repair. Articular cartilage and bone extracellular matrix have been shown to produce …


Differentiation Of Mouse Embryonic Stem Cells Into Insulin-Producing Cells: Optimization To Enhance The Overall Differentiation Efficiency, Xiaotang Ma May 2015

Differentiation Of Mouse Embryonic Stem Cells Into Insulin-Producing Cells: Optimization To Enhance The Overall Differentiation Efficiency, Xiaotang Ma

Theses

Embryonic stem cells have the potential to differentiate into multiple cell types including insulin-producing cells (IPCs), which is becoming one of the promising cell sources for treating type 1 diabetes mellitus. However, in order to achieve functional stem cell-derived cells, it is important to generate more mature IPCs and to keep long-term viability post differentiation process. In this study, we varied several factors including different embryonic body culture conditions, digested cells seeding density and various coatings required for differentiation to optimize a previously established protocol to enhance the overall differentiation efficiency. Moreover, a three-dimensional in vitro collagen tissue culture system …


Tendon Reflex Protocol For Exploring The Mechanisms Associated With Whole Body Vibration, Ikechukwu Okeke May 2015

Tendon Reflex Protocol For Exploring The Mechanisms Associated With Whole Body Vibration, Ikechukwu Okeke

Theses

Whole body vibration (WBV) machines have in recent years been widely used as rehabilitation equipment. Whole body vibration has been shown to have positive effects on muscle response. Cerebral palsy (CP) is a neurodevelopmental condition that includes a group of non-progressive, but often changing, motor impairment syndromes arising in the early stages of human development. The aim of this project was to design a protocol and related instruments to assess the tendon reflex in response to WBV. Both a press pedal used for measuring the force exerted by the foot and a hammer used for measuring the stimulating force were …


Behavior Of Deformed Dermal Fibroblasts Seeded On A Silicon Membrane Under High Levels Of Strain, Laura Osorno May 2015

Behavior Of Deformed Dermal Fibroblasts Seeded On A Silicon Membrane Under High Levels Of Strain, Laura Osorno

Theses

The main objective of this thesis is to understand, from a molecular perspective, the morphological and functional abnormalities of human dermal fibroblasts as a response to deformation produced by a normal force that can lead to the potential formation of stretch marks in pregnant women, adolescents, and people with Cushing's syndrome. The main function of dermal fibroblasts is to produce the essential fibrous components of the extracellular matrix (ECM) of the skin.

In order to study the mechanism of stretch mark formation, neonatal human dermal fibroblasts were seeded on a silicon membrane for controlled deformation. Upon reaching a confluence of …


Significant Degradability Enhancement In Multilayer Coating Of Polycaprolactone-Bioactive Glass/Gelatin-Bioactive Glass On Magnesium Scaffold For Tissue Engineering Applications, Mostafa Yazdimamaghani, Mehdi Razavi, Daryoosh Vashaee, Venkata Raveendra Pothineni, Jayakumar Rajadas, Lobat Tayebi May 2015

Significant Degradability Enhancement In Multilayer Coating Of Polycaprolactone-Bioactive Glass/Gelatin-Bioactive Glass On Magnesium Scaffold For Tissue Engineering Applications, Mostafa Yazdimamaghani, Mehdi Razavi, Daryoosh Vashaee, Venkata Raveendra Pothineni, Jayakumar Rajadas, Lobat Tayebi

Chemical and Biochemical Engineering Faculty Research & Creative Works

Magnesium (Mg) is a promising candidate to be used in medical products especially as bone tissue engineering scaffolds. The main challenge for using Mg in biomedical applications is its high degradation rate in the body. For this reason, in this study, a multilayer polymeric layer composed of polycaprolactone (PCL) and gelatin (Gel) reinforced with bioactive glass (BaG) particles has been applied on the surface of Mg scaffolds. The materials characteristics of uncoated Mg scaffold, Mg scaffold coated only with PCL-BaG and Mg scaffold coated with PCL-BaG and Gel-BaG have been analyzed and compared in detail. Scanning electron microscope (SEM) equipped …


Effects Of Individualized Centrifugation Training On Orthostatic Tolerance In Men And Women, Nandu Goswami, Joyce Evans, Stefan Schneider, Melanie Von Der Wiesche, Edwin Mulder, Andreas Rössler, Helmut Hinghofer-Szalkay, Andrew P. Blaber May 2015

Effects Of Individualized Centrifugation Training On Orthostatic Tolerance In Men And Women, Nandu Goswami, Joyce Evans, Stefan Schneider, Melanie Von Der Wiesche, Edwin Mulder, Andreas Rössler, Helmut Hinghofer-Szalkay, Andrew P. Blaber

Biomedical Engineering Faculty Publications

AIMS: Exposure to artificial gravity (AG) at different G loads and durations on human centrifuges has been shown to improve orthostatic tolerance in men. However, the effects on women and of an individual-specific AG training protocol on tolerance are not known.

METHODS: We examined the effects of 90 minutes of AG vs. 90 minutes of supine rest on the orthostatic tolerance limit (OTL), using head up tilt and lower body negative pressure until presyncope of 7 men and 5 women. Subjects were placed in the centrifuge nacelle while instrumented and after one-hour they underwent either: 1) AG exposure …


Method And Apparatus For Treating Centralized Pain, Jeffrey Hargrove May 2015

Method And Apparatus For Treating Centralized Pain, Jeffrey Hargrove

Mechanical Engineering Patents

A method for alleviating centralized pain in human subjects includes assessing the brain of a subject suffering from pain, diagnosing abnormal brain function associated with centralized pain, locating at least one area of abnormal brain function associated with the centralized pain, and alleviating the abnormal brain function by applying a cortical stimulation signal to tissues corresponding to the at least one area of abnormal brain function.


Gold Nanostructures For Sensing And Functional Bioimaging, Maximilian Y. Fei May 2015

Gold Nanostructures For Sensing And Functional Bioimaging, Maximilian Y. Fei

McKelvey School of Engineering Graduate Student Theses & Dissertations

Gold nanostructures offer an extremely promising path forward in the fields of imaging and sensing because of their unique optical and chemical properties. Here, we demonstrate that plasmonic nanostructures can be employed as nanoscale transducers to monitor the growth and phase transitions in ultrathin polymer films. In particular, gold nanorods with high refractive index sensitivity (~150 nm / refractive index unit (RIU)) were employed to probe the growth and swelling of polyelectrolyte multilayers (PEM). By comparing the wavelength shift and extinction intensity of the localized surface plasmon resonance (LSPR) of the gold nanorods coated with PEM in air and water, …


Computational Fluid Dynamics Applied To The Analysis Of Blood Flow Through Central Aortic To Pulmonary Artery Shunts, Carey Celestin Jr May 2015

Computational Fluid Dynamics Applied To The Analysis Of Blood Flow Through Central Aortic To Pulmonary Artery Shunts, Carey Celestin Jr

LSU New Orleans Theses and Dissertations

This research utilizes CFD to analyze blood flow through pathways representative of central shunts, commonly used as part of the Fontan procedure to treat cyanotic heart disease. In the first part of this research, a parametric study of steady, Newtonian blood flow through parabolic pathways was performed to demonstrate the effect that flow pathway curvature has on wall shear stress distribution and flow energy losses. In the second part, blood flow through two shunts obtained via biplane angiograms is simulated. Pressure boundary conditions were obtained via catheterization. Results showed that wall shear stresses were of sufficient magnitude to initiate platelet …


Portable Polarimetric Fiber Stress Sensor System For Visco-Elastic And Biomimetic Material Analysis, Mark C. Harrison, Andrea M. Armani May 2015

Portable Polarimetric Fiber Stress Sensor System For Visco-Elastic And Biomimetic Material Analysis, Mark C. Harrison, Andrea M. Armani

Engineering Faculty Articles and Research

Non-destructive materials characterization methods have significantly changed our fundamental understanding of material behavior and have enabled predictive models to be developed. However, the majority of these efforts have focused on crystalline and metallic materials, and transitioning to biomaterials, such as tissue samples, is non-trivial, as there are strict sample handling requirements and environmental controls which prevent the use of conventional equipment. Additionally, the samples are smaller and more complex in composition. Therefore, more advanced sample analysis methods capable of operating in these environments are needed. In the present work, we demonstrate an all-fiber-based material analysis system based on optical polarimetry. …


A Space-Variant Model For Motion Interpretation Across The Visual Field, Guido Maiello, Manuela Chessa, Peter J. Bex, Fabio Solari May 2015

A Space-Variant Model For Motion Interpretation Across The Visual Field, Guido Maiello, Manuela Chessa, Peter J. Bex, Fabio Solari

MODVIS Workshop

We implement a neural model for the estimation of the focus of radial motion (FRM) at different retinal locations and we assess the model by comparing its results with respect to the precision with which human observers can estimate the FRM in naturalistic, moving dead leaves stimuli. The proposed neural model describes the deep hierarchy of the first stages of the dorsal visual pathway [Solari et al., 2014]. Such a model is space-variant, since it takes into account the retino-cortical transformation of the primate visual system through log-polar mapping that produces a cortical representation of the visual signal to the …


Implementation Of Raman Spectroscopy At Manufacturing Scale: Overcoming Modeling Challenges While Implementing Advanced Process Control, John Smelko, Thomas Matthews, Brandon Berry, Douglas Osborne May 2015

Implementation Of Raman Spectroscopy At Manufacturing Scale: Overcoming Modeling Challenges While Implementing Advanced Process Control, John Smelko, Thomas Matthews, Brandon Berry, Douglas Osborne

Cell Culture Engineering XV

In order to improve glycation control in our new high intensity platform process, we investigated implementation of Raman spectroscopy to monitor and control glucose at low levels throughout the process. Using Raman allows a way to measure glucose near real time which in turn allows for a more responsive and flexible control algorithm. Prior literature has shown connections between elevated glucose levels and glycation when in presence of high protein concentrations, which was indicative of our process. Using Raman along with advanced process control (APC), allowed us the flexibility to reduce glycation back towards historical process levels.

We will share …


New Design Of Nasogastric Decompression Tube That Incorporates A Self-Cleaning Brushing Mechanism, Nichole Abla, Lindsay Rucker, Paige Schroder May 2015

New Design Of Nasogastric Decompression Tube That Incorporates A Self-Cleaning Brushing Mechanism, Nichole Abla, Lindsay Rucker, Paige Schroder

Senior Theses

Many hospitalized patients require the removal of secretions that accumulate in the stomach and must be removed by a nasogastric tube, which unfortunately clogs often. This project outlines the redesign of the nasogastric tube that will ideally prevent nasogastric tube clogging by incorporating a brush mechanism and a contracting tip mechanism, to act as preventative measures against clogging.


Towards A Dynamic Clamp For Neurochemical Modalities, C. M. Rivera, H.-J. Kwon, A. Hashmi, Gu Yu, J. Zhao, J. Gao, J. Xu, Wei Xue, A. G. Dimitrov May 2015

Towards A Dynamic Clamp For Neurochemical Modalities, C. M. Rivera, H.-J. Kwon, A. Hashmi, Gu Yu, J. Zhao, J. Gao, J. Xu, Wei Xue, A. G. Dimitrov

Henry M. Rowan College of Engineering Departmental Research

The classic dynamic clamp technique uses a real-time electrical interface between living cells and neural simulations in order to investigate hypotheses about neural function and structure. One of the acknowledged drawbacks of that technique is the limited control of the cells’ chemical microenvironment. In this manuscript, we use a novel combination of nanosensor and microfluidic technology and microfluidic and neural simulations to add sensing and control of chemical concentrations to the dynamic clamp technique. Specifically, we use a microfluidic lab-on-a-chip to generate distinct chemical concentration gradients (ions or neuromodulators), to register the concentrations with embedded nanosensors and use the processed …


3d Printing In Healthcare, Caleb Branch May 2015

3d Printing In Healthcare, Caleb Branch

The Review: A Journal of Undergraduate Student Research

Technology is everywhere. Technology surrounds every aspect of 21st century life. It is in the cell phones we use, the cars we drive, and even the food we eat. A large portion of modern technology used is taken for granted and overlooked. Despite this, some technology fields continue to grow. Biomedical engineering, specifically 3D printing’s applications to healthcare, has been often overlooked until. Regardless of its status in the mainstream, 3D printing is prosperous in healthcare and its future looks bright. This piece analyzes 3D printing in healthcare. It hones in on the finer details of each specific topic, …


Section Abstracts: Biomedical And General Engineering May 2015

Section Abstracts: Biomedical And General Engineering

Virginia Journal of Science

Abstracts of the Biomedical and General Engineering Section for the 93rd Annual Meeting of the Virginia Academy of Science, May 21-23, 2015, James Madison University, Richmond, Virginia


A Comparative Evaluation Of Cadaveric And Composite Femur Models For Total Hip Arthroplasty, Anderson Lynn Adams May 2015

A Comparative Evaluation Of Cadaveric And Composite Femur Models For Total Hip Arthroplasty, Anderson Lynn Adams

Graduate Theses - Biology & Biomedical Engineering

Composite bones are often used in testing of orthopedic implants due to their relative ease of use and low inter-specimen variability when compared to cadaveric bones. Tests were run to ensure that the composite bones remained an acceptable model for cadaver bones throughout surgical manipulation. Composite (n=6) and cadaver (n=6) femur specimen were subjected to a total hip arthroplasty (THA). Flexural rigidity, axial stiffness, and axial strain measurements were taken at various stages in the surgical process. The composite and cadaver specimen were not found to behave similarly in either flexural rigidity or axial stiffness tests. The results showed a …


Mobile Health Sensing With Smart Phones, Abby Logan Wise May 2015

Mobile Health Sensing With Smart Phones, Abby Logan Wise

Electrical Engineering Undergraduate Honors Theses

Depression is a serious mental condition affecting many Americans and people across the world. Postpartum depression is a form of depression affecting women who have recently gone through childbirth. Postpartum depression can have serious symptoms that may affect not only the mother, but her newborn as well. Early detection of these symptoms is of critical importance to the welfare of the mother and her child. Many medical professionals express the need for postpartum screening being that treatment has proven to be very effective. This project aims to make early symptom detection convenient and reliable for mothers with newborns. This will …


Vcare: A Personal Emergency Response System To Promote Safe And Independent Living Among Elders Staying By Themselves In Community Or Residential Settings, Priyankar Bhattacharjee May 2015

Vcare: A Personal Emergency Response System To Promote Safe And Independent Living Among Elders Staying By Themselves In Community Or Residential Settings, Priyankar Bhattacharjee

Department of Computer Electronics and Engineering: Dissertations, Theses, and Student Research

‘Population aging’ is a growing concern for most of us living in the twenty first century, primarily because many of us in the next few years will have a senior person to care for - spending money towards their healthcare expenditures AND/OR having to balance a full-time job with the responsibility of care-giving, travelling from another city to be with this elderly citizen who might be our parent, grand-parent or even community elders. As informal care-givers, if somehow we were able to monitor the day-to-day activities of our elderly dependents, and be alerted when wrong happens to them that would …


Evaluating The Viability Of Graphene Oxide For The Removal Of Ni(Ii) Ions From Waste Water, Cale M. White May 2015

Evaluating The Viability Of Graphene Oxide For The Removal Of Ni(Ii) Ions From Waste Water, Cale M. White

Biomedical Engineering Undergraduate Honors Theses

When levels of heavy metal ions such as nickel (Ni), copper (Cu), lead (Pb), Zinc (Zn), and Cobalt (Co) exceed the tolerance values for industrial wastewater, it can devastate the environment as well as the health of the individuals consuming the water. Heavy metal ions are not biodegradable and will accumulate in organic matter.(1) This accumulation leads to toxic levels in the blood and hence damage to nerve tissue, kidneys, the liver, and other vital organs. (2) Effective removal processes of these heavy metals from water must be developed. This study explores a method to adsorb nickel from water with …


Synthesis, Functionalization, And Characterization Of Metallic And Organic Nanoparticles For Biomedical Applications, Christopher Brian Sylvester May 2015

Synthesis, Functionalization, And Characterization Of Metallic And Organic Nanoparticles For Biomedical Applications, Christopher Brian Sylvester

Honors Capstones

No abstract provided.


Design Of A Simple Device For Accurate Measurement Of Human Blood Viscosity In Oxygenated And Deoxygenated Conditions, Catherine E. Oliver, Jessica Hockla, Divya Kamireddi May 2015

Design Of A Simple Device For Accurate Measurement Of Human Blood Viscosity In Oxygenated And Deoxygenated Conditions, Catherine E. Oliver, Jessica Hockla, Divya Kamireddi

Honors Scholar Theses

The purpose of this research is to design, fabricate, and test a simple device that can accurately measure the viscosity of whole blood in both an oxygenated and a deoxygenated environment. The ideal device is easy to operate, inexpensive to fabricate, and is usable outside of a laboratory setting. The microfluidic rheometer presented here was fabricated using a wet chemical etching method. Using the channel dimensions, the known viscosity of a reference fluid, and the velocity of fluid flow of the sample and a reference fluid through the microchannels the unknown viscosity of a sample fluid is calculated.


Assessment Of Bore-Cone Taper Junctions In Explanted Modular Total Hip Replacements, Christine Margaret Stamer May 2015

Assessment Of Bore-Cone Taper Junctions In Explanted Modular Total Hip Replacements, Christine Margaret Stamer

All Theses

For people with chronic hip pain due to arthritis or other conditions, a total hip replacement (THR) is a common procedure used to eliminate the pain. Due to the natural variation in patient anatomy, THR prostheses are becoming increasingly more modular to allow for a more customized initial replacement and for an easier revision if needed in the future. Currently, THR prostheses routinely have modular femoral heads to provide surgeons with intraoperative flexibility. This modularity allows the surgeons to maintain the proper leg length and restore hip biomechanics for the patient and insert the components more easily and precisely. Modular …