Open Access. Powered by Scholars. Published by Universities.®
- Institution
-
- California Polytechnic State University, San Luis Obispo (61)
- Michigan Technological University (35)
- New Jersey Institute of Technology (31)
- Utah State University (30)
- Wright State University (29)
-
- Clemson University (25)
- University of Nebraska - Lincoln (19)
- University of Arkansas, Fayetteville (18)
- Al Esraa University (16)
- Missouri University of Science and Technology (16)
- Raynor Library Marquette University (16)
- Yıldız Technical University (13)
- Cleveland State University (12)
- University of South Florida (12)
- Louisiana Tech University (11)
- The University of Akron (10)
- Virginia Commonwealth University (10)
- Old Dominion University (8)
- Rowan University (8)
- Tashkent State Technical University (8)
- University of Kentucky (8)
- Boise State University (7)
- Florida Institute of Technology (7)
- Wayne State University (7)
- Louisiana State University (6)
- Purdue University (6)
- Technological University Dublin (6)
- University of Louisville (6)
- University of Mississippi (6)
- Santa Clara University (5)
- Keyword
-
- Corrosion (18)
- Department of Biomedical Engineering (17)
- Biomaterials (15)
- Biocompatibility (11)
- Magnesium (11)
-
- Microstructure (11)
- Engineering (10)
- Implants (10)
- Microfluidics (10)
- Stent (10)
- Tissue engineering (10)
- Titanium (10)
- Applied sciences (9)
- Biosensors (9)
- Biodegradable (8)
- Mechanical engineering and machinery (8)
- TJ1-1570 (8)
- Bone (7)
- Mechanical properties (7)
- Zinc (7)
- Biofilm (6)
- Biomechanics (6)
- Biomedical (6)
- Biomedical engineering (6)
- Bioreactor (6)
- Dental alloy (6)
- Department of Biomedical, Industrial & Human Factors Engineering (6)
- Nanotechnology (6)
- Prosthesis (6)
- Prosthetic (6)
- Publication Year
- Publication
-
- Theses and Dissertations (30)
- Theses (27)
- Biomedical Engineering (26)
- Master's Theses (22)
- Biomedical, Industrial & Human Factors Engineering Faculty Publications (21)
-
- Cells and Materials (19)
- Al-Esraa University College Journal for Engineering Sciences (16)
- All Dissertations (16)
- Biomedical Engineering Faculty Research and Publications (15)
- Chemical and Biochemical Engineering Faculty Research & Creative Works (14)
- Journal of Sustainable Construction Materials and Technologies (13)
- Michigan Tech Publications, Part 1 (13)
- Dissertations, Master's Theses and Master's Reports (12)
- USF Tampa Graduate Theses and Dissertations (12)
- Doctoral Dissertations (11)
- Graduate Theses and Dissertations (11)
- ETD Archive (10)
- Electronic Theses and Dissertations (10)
- Williams Honors College, Honors Research Projects (10)
- Browse all Theses and Dissertations (8)
- Honors Theses (8)
- Technical science and innovation (8)
- All Theses (7)
- Department of Agricultural and Biological Systems Engineering: Faculty Publications (7)
- All Graduate Theses and Dissertations, Spring 1920 to Summer 2023 (6)
- Dissertations (6)
- Mechanical Engineering (6)
- Materials Engineering (5)
- Mechanical and Biomedical Engineering Faculty Publications and Presentations (5)
- Articles (4)
- Publication Type
Articles 451 - 480 of 529
Full-Text Articles in Entire DC Network
Development And Modeling Of High Temperature Polymeric Heater, Maziyar Bolourchi
Development And Modeling Of High Temperature Polymeric Heater, Maziyar Bolourchi
ETD Archive
Polymers are generally known for their excellent insulative properties. The addition of carbonaceous fillers such as carbon black and graphite within a polymer matrix can impart electrical and thermal properties making them good conductors. The resulting composites can be used in applications requiring and/or ranging from electromagnetic and radio frequency interference (EMI/RFI) shielding, electrostatic discharge (ESD) and heaters/heating elements to which metals have been the materials of choice. The advantages of using such composites include cost reduction, part consolidation, chemical resistance, lighter weight, and ability to easily design into complex three dimensional shapes via injection molding. For this work, various …
Fabrication And Testing Of Scaffolds For Cell Growth From Ionic Liquid Solubilized Fibroin, Maneesh Kumar Gupta
Fabrication And Testing Of Scaffolds For Cell Growth From Ionic Liquid Solubilized Fibroin, Maneesh Kumar Gupta
Browse all Theses and Dissertations
The advent of tissue engineering has spurred research into developing materials to act as scaffolds for tissue growth. These scaffolds require materials capable of mimicking the in vivo conditions so that tissues can be grown effectively in vitro. Silk is an attractive biomaterial for use in tissue engineering applications because of its slow degradation, excellent mechanical properties, and biocompatibility. The major objective of the research in this thesis is to demonstrate a simple method to cast films directly from silk fibroin dissolved in an ionic liquid. The films cast from the silk ionic liquid solution were found to support normal …
In-Vitro Characterization Of Boronized Titanium Alloy By Means Of Corrosion And Electrochemical Impedance Spectroscopy Methods In Simulated Body Fluids, David Anthony Panus
In-Vitro Characterization Of Boronized Titanium Alloy By Means Of Corrosion And Electrochemical Impedance Spectroscopy Methods In Simulated Body Fluids, David Anthony Panus
Theses
Titanium and titanium alloys are becoming the backbone of medical implants and prosthetics. Titanium alloys are used because of its high biocompatibility and similarity to bone. However, titanium and titanium alloys have a low wear resistance. Titanium and titanium alloys are susceptible to particle erosion, which can cause inflammation, infection, and even implant rejection. Boronizing titanium alloy improves titanium's wear resistance and also improves corrosion resistance.
The target of this research was to characterize the corrosion characteristics of both unboronized and boronized titanium using both electrochemical corrosion methods and Electrochemical Impedance Spectroscopy (ELS) in simulated body fluid. Using electrochemical methods …
Explant Analysis Of Total Disc Replacement, Paul A. Anderson, Steven M. Kurtz, Jeffrey M. Toth
Explant Analysis Of Total Disc Replacement, Paul A. Anderson, Steven M. Kurtz, Jeffrey M. Toth
Biomedical Engineering Faculty Research and Publications
Explant analysis of human disc prostheses allow early evaluation of the host response to the prosthesis and the response of the prosthesis from the host. Furthermore, early predictions of failure and wear can be obtained. Thus far, about 2-3% of disc prostheses have been removed. Observed wear patterns are similar to that of appendicular prostheses including abrasions/scratching, burnishing, surface deformation, fatigue, and embedded debris. Chemically the polymeric components have shown little degradation in short-term implantation. In metal on metal prostheses the histologic responses consist of large numbers of metallic particles with occasional macrophages and giant cells. Only rare cases of …
Development Of Self-Assembled Monolayer-Based Cell Culture Platform Towards Fabrication Of A Three-Dimensional Bioreactor, Rajendra Kandoor Aithal
Development Of Self-Assembled Monolayer-Based Cell Culture Platform Towards Fabrication Of A Three-Dimensional Bioreactor, Rajendra Kandoor Aithal
Doctoral Dissertations
The extracellular matrix (ECM) plays an important role in regulating a number of cellular properties and functions like cell differentiation, cell synthesis and degradation, cell viability and proliferation, cell function, and cell aging. Surface modification of planar substrates with self-assembled monolayers (SAMs) is a promising technique to achieve stable ECMs.
In this work, substrates such as silicon (Si), gallium arsenide (GaAs) and indium tin oxide (ITO) substrates were modified with SAMS containing amino (-NH2), methyl (-CH3), thiol (-SH) and carboxylic (-COOH) end groups and characterized using contact angle measurements, surface infrared (IR) spectroscopy and atomic force microscopy (AFM). Different cell …
Non-Invasive Monitoring Of Bone Health Using Ultrasound, Nashit Jahan Meem
Non-Invasive Monitoring Of Bone Health Using Ultrasound, Nashit Jahan Meem
Theses
Bone fractures are estimated to afflict everyone at least once in his/her lifetime. Monitoring this becomes crucial especially when it comes to athletes in order for them to safely resume their regular activities as soon as possible. Technologies currently employed are either very expensive or use harmful radiation.
Ultrasound can monitor bone fractures in a non-invasive manner, as discussed in United States Patent # 5143069. Three transducers are mounted over the test specimen. A pulse generator excites the transmitting receiver. The second receiver is mounted next to the transmitter and acts as a reference receiver that displays the response across …
Design And Validation Of A Full Contact Gait Simulator For The Cadaveric Lower Extremity, Joseph Michael Iaquinto
Design And Validation Of A Full Contact Gait Simulator For The Cadaveric Lower Extremity, Joseph Michael Iaquinto
Theses and Dissertations
The projects goal was to create a device to simulate full contact gait in the cadaveric lower extremity. The Contact Gait Simulation System loads specific muscles to recreate anatomical dorsi and plantar flexion of the ankle under axial loading. A system of pneumatic load generation was connected a LabVIEW virtual instrument (VI), which controlled the application of these loads. The loads were roughly based off literature cited EMG data, and further modified from feedback. In addition to controlling the load system, the VI also coordinates external sensor timing. Along with this simulator, software was developed specifically for analyzing pressure data …
Integration Of Micro Nano And Bio Technologies With Layer -By -Layer Self -Assembly, Dinesh Shankar Kommireddy
Integration Of Micro Nano And Bio Technologies With Layer -By -Layer Self -Assembly, Dinesh Shankar Kommireddy
Doctoral Dissertations
In the past decade, layer-by-layer (LbL) nanoassembly has been used as a tool for immobilization and surface modification of materials with applications in biology and physical sciences. Often, in such applications, LbL assembly is integrated with various techniques to form functional surface coatings and immobilized matrices. In this work, integration of LbL with microfabrication and microfluidics, and tissue engineering are explored. In an effort to integrate microfabrication with LbL nanoassembly, microchannels were fabricated using soft-lithography and the surface of these channels was used for the immobilization of materials using LbL and laminar flow patterning. Synthesis of poly(dimethyldiallyl ammonium chloride)/poly(styrene sulfonate) …
Microfocal X-Ray Computed Tomography Post-Processing Operations For Optimizing Reconstruction Volumes Of Stented Arteries During 3d Computational Fluid Dynamics Modeling, John F. Ladisa, Lars E. Olson, Kristina M. Ropella, Robert C. Molthen, Steven Thomas Haworth, Judy R. Kersten, David C. Warltier, Paul S. Pagel
Microfocal X-Ray Computed Tomography Post-Processing Operations For Optimizing Reconstruction Volumes Of Stented Arteries During 3d Computational Fluid Dynamics Modeling, John F. Ladisa, Lars E. Olson, Kristina M. Ropella, Robert C. Molthen, Steven Thomas Haworth, Judy R. Kersten, David C. Warltier, Paul S. Pagel
Biomedical Engineering Faculty Research and Publications
Restenosis caused by neointimal hyperplasia (NH) remains an important clinical problem after stent implantation. Restenosis varies with stent geometry, and idealized computational fluid dynamics (CFD) models have indicated that geometric properties of the implanted stent may differentially influence NH. However, 3D studies capturing the in vivo flow domain within stented vessels have not been conducted at a resolution sufficient to detect subtle alterations in vascular geometry caused by the stent and the subsequent temporal development of NH. We present the details and limitations of a series of post-processing operations used in conjunction with microfocal X-ray CT imaging and reconstruction to …
Alterations In Wall Shear Stress Predict Sites Of Neointimal Hyperplasia After Stent Implantation In Rabbit Iliac Arteries, John F. Ladisa, Lars E. Olson, Robert C. Molthen, Douglas Anthony Hettrick, Phillip F. Pratt, Michael D. Hardel, Judy R. Kersten, David C. Warltier, Paul S. Pagel
Alterations In Wall Shear Stress Predict Sites Of Neointimal Hyperplasia After Stent Implantation In Rabbit Iliac Arteries, John F. Ladisa, Lars E. Olson, Robert C. Molthen, Douglas Anthony Hettrick, Phillip F. Pratt, Michael D. Hardel, Judy R. Kersten, David C. Warltier, Paul S. Pagel
Biomedical Engineering Faculty Research and Publications
Restenosis resulting from neointimal hyperplasia (NH) limits the effectiveness of intravascular stents. Rates of restenosis vary with stent geometry, but whether stents affect spatial and temporal distributions of wall shear stress (WSS) in vivo is unknown. We tested the hypothesis that alterations in spatial WSS after stent implantation predict sites of NH in rabbit iliac arteries. Antegrade iliac artery stent implantation was performed under angiography, and blood flow was measured before casting 14 or 21 days after implantation. Iliac artery blood flow domains were obtained from three-dimensional microfocal X-ray computed tomography imaging and reconstruction of the arterial casts. Indexes of …
Biosensing With Microcantilever-Based Sensors, Xiaodong Yan
Biosensing With Microcantilever-Based Sensors, Xiaodong Yan
Doctoral Dissertations
Microcantilevers provide an ideal platform for biosensors. The micron-sized transducer brings several advantages, such as high sensitivity, small sample quantity for analysis, portability, implantable sensor devices, and the ability to be mass produced and integrated into standard microelectronic processing technologies like complementary metal oxide seminconductors (CMOS).
The objective of this research is to investigate and develop modification methods of microcanitlevers for biosensing applications.
Two microcantilever modification methods were investigated. They are self-assembly monolayer method and layer-by-layer method. A fundamental procedure for modification of microcantilevers using the layer-by-layer approach was developed for the first time in this research. These modification methods …
Quantitative Models Of The Rat Pulmonary Arterial Tree Morphometry Applied To Hypoxia-Induced Arterial Remodeling, Robert C. Molthen, Kelly L. Karau, Christopher A. Dawson
Quantitative Models Of The Rat Pulmonary Arterial Tree Morphometry Applied To Hypoxia-Induced Arterial Remodeling, Robert C. Molthen, Kelly L. Karau, Christopher A. Dawson
Biomedical Engineering Faculty Research and Publications
Little is known about the constituent hemodynamic consequences of structural changes that occur in the pulmonary arteries during the onset and progression of pulmonary arterial remodeling. Many disease processes are known to be responsible for vascular remodeling that leads to pulmonary arterial hypertension, cor pulmonale, and death. Histology has been the primary tool for evaluating pulmonary remodeling, but it does not provide information on intact vascular structure or the vessel mechanical properties. This study is an extension of our previous work in which we developed an alternative imaging technique to evaluate pulmonary arterial structure. The lungs from Sprague-Dawley rats were …
Techniques For Investigation Of Surgical Cutting Instruments, Eamon Price, Ger Reilly, Brendan Mccormack, Andrew Macey
Techniques For Investigation Of Surgical Cutting Instruments, Eamon Price, Ger Reilly, Brendan Mccormack, Andrew Macey
Conference Papers
No abstract provided.
Spinning Of Collagen Fibers And Characterizing Thermal, Mechanical, Tensile And Structural Properties, Grace Evangelin Tatagiri
Spinning Of Collagen Fibers And Characterizing Thermal, Mechanical, Tensile And Structural Properties, Grace Evangelin Tatagiri
Theses
Collagen is the most important building block in the entire animal world. It plays an important role in regeneration of broken bones and wound healing, also helps grow blood vessels to feed the healing areas. The use of synthetic materials has been extensive, but these materials have there own limits and drawbacks. Poor biocompatibility of these materials is the main issue and often result in inflammations. Hence collagen is being heralded as one of the most appropriate replacement as an implantable material. The reasons being that it is a naturally occurring material, exhibits high biocompatibility low antigenicity and host response. …
Overview Of Metal-On-Polyethylene, Metal-On-Metal, And Ceramic Hip Wear Mechanisms, A. Buford, Tarun Goswami
Overview Of Metal-On-Polyethylene, Metal-On-Metal, And Ceramic Hip Wear Mechanisms, A. Buford, Tarun Goswami
Biomedical, Industrial & Human Factors Engineering Faculty Publications
Premature failure of orthopaedic hip implants caused by multiple wear mechanisms is the primary failure mode of prosthetic hips. Wearing of the implants may lead to aseptic loosening, biological incompatibilities, and mechanical failure of the implant. In order to prevent or restrict the effects of the wear mechanisms, multiple laboratory studies are being conducted in order to determine each mechanism and its contribution to increased wear rates. This paper combines previous laboratory studies related to the wear of metal-onpolyethylene, metal-on-metal, and ceramic materials. The bulk quantity materials discussed include cobalt chromium alloys, stainless steels, zirconium oxide ceramics, and polyethylene materials …
Wear Mechanisms In Ceramic Hip Implants, M. Slonaker
Wear Mechanisms In Ceramic Hip Implants, M. Slonaker
Biomedical, Industrial & Human Factors Engineering Faculty Publications
The wear in hip implants is one of the main causes for premature hip replacements. The wear affects the potential life of the prosthesis and subsequent removals of in-vivo implants. Therefore, the objective of this article is to review various joints that show lower wear rates and consequently higher life. Ceramics are used in hip implants and have been found to produce lower wear rates. This article discusses the advantages and disadvantages of ceramics compared to other implant materials. Different types of ceramics that are being used are reviewed in terms of the wear characteristics, debris released, and their size …
Wear Mechanisms In Ceramic Hip Implants, M. Slonaker, Tarun Goswami
Wear Mechanisms In Ceramic Hip Implants, M. Slonaker, Tarun Goswami
Biomedical, Industrial & Human Factors Engineering Faculty Publications
The wear in hip implants is one of the main causes for premature hip replacements. The wear affects the potential life of the prosthesis and subsequent removals of in-vivo implants. Therefore, the objective of this article is to review various joints that show lower wear rates and consequently higher life. Ceramics are used in hip implants and have been found to produce lower wear rates. This article discusses the advantages and disadvantages of ceramics compared to other implant materials. Different types of ceramics that are being used are reviewed in terms of the wear characteristics, debris released, and their size …
An Automated Coronary Artery Occlusion Device For Stimulating Collateral Development In Vivo, Richard Rys, John F. Ladisa, John P. Tessmer, Weidong Gu, Judy R. Kersten, David C. Warltier, Paul S. Pagel
An Automated Coronary Artery Occlusion Device For Stimulating Collateral Development In Vivo, Richard Rys, John F. Ladisa, John P. Tessmer, Weidong Gu, Judy R. Kersten, David C. Warltier, Paul S. Pagel
Biomedical Engineering Faculty Research and Publications
Introduction: Repetitive, brief coronary artery occlusions produce collateral development in experimental animals. This model causes coronary collateralization in a highly reproducible fashion, but the process is very labor intensive. We report the design and use of a fully automated hydraulic coronary occlusion device capable of producing repetitive coronary occlusions and enhancement of coronary collateral development in dogs.
Methods: The device consists of analog electronics that allow adjustment of occlusion number, frequency, pressure and duration, and mechanical components responsible for the coronary occlusion. The motor and piston of the device are coupled to a chronically implanted hydraulic vascular occluder …
Estimation Of Pulmonary Arterial Volume Changes In The Normal And Hypertensive Fawn-Hooded Rat From 3d Micro-Ct Data, Robert C. Molthen, Christian Wieholt, Steven Thomas Haworth, Christopher A. Dawson
Estimation Of Pulmonary Arterial Volume Changes In The Normal And Hypertensive Fawn-Hooded Rat From 3d Micro-Ct Data, Robert C. Molthen, Christian Wieholt, Steven Thomas Haworth, Christopher A. Dawson
Biomedical Engineering Faculty Research and Publications
In the study of pulmonary vascular remodeling, much can be learned from observing the morphological changes undergone in the pulmonary arteries of the rat lung when exposed to chronic hypoxia or other challenges which elicit a remodeling response. Remodeling effects include thickening of vessel walls, and loss of wall compliance. Morphometric data can be used to localize the hemodynamic and functional consequences. We developed a CT imaging method for measuring the pulmonary arterial tree over a range of pressures in rat lungs. X-ray micro-focal isotropic volumetric imaging of the arterial tree in the intact rat lung provides detailed information on …
Effect Of Exposure Time On The Fatigue Crack Growth Behavior Of Aircraft Skin Material, Kathryn Lemasters, Tarun Goswami
Effect Of Exposure Time On The Fatigue Crack Growth Behavior Of Aircraft Skin Material, Kathryn Lemasters, Tarun Goswami
Biomedical, Industrial & Human Factors Engineering Faculty Publications
The objective of this research project is to identify the effects of service exposure on aircraft materials. The senior author participated in the KC-135 Corrosion Prevention Program conducted by the University of Utah, Salt Lake City. Data from this research program was analyzed to compare the fatigue crack growth rates of aged aircraft materials with those of virgin materials. 2024-T3(clad) Middle Tension (M(T)) specimens were machined from the fuselage and upper wing skins of a retired aircraft. Fatigue crack growth rate (da/dN) and mode 1 stress intensity factor range (Δ K) plots were generated for both sets of data. The …
Failure Modes Of Biomedical Implants, Andrew Gratton, Bert Buford, Tarun Goswami, Dana Gaddykurten, Larry Suva
Failure Modes Of Biomedical Implants, Andrew Gratton, Bert Buford, Tarun Goswami, Dana Gaddykurten, Larry Suva
Biomedical, Industrial & Human Factors Engineering Faculty Publications
The metallic biomaterials are very well known among various biomaterials. Stainless steel was used successfully as an implant material in the surgical field, then Vitallium, cobalt based alloys were used as implant materials. Titanium is the newest metallic biomaterial among three main metallic biomaterials, stainless steels, Co-based alloys and titanium alloys. These materials are used for the instrumentation replacing failed hard tissue, for example, artificial hip joints, artificial knee joints, bone plates, dental implants and in similar applications. Biocompatibility characteristics of titanium alloys make it the preferred choice for such applications, additional factors being light weight, excellent mechanical properties, corrosion …
Pulmonary Arterial Morphometry From Microfocal X-Ray Computed Tomography, Kelly L. Karau, Robert C. Molthen, Anita H. Dhyani, Steven Thomas Haworth, Christopher C. Hanger, David L. Roerig, Roger H. Johnson, Christopher A. Dawson
Pulmonary Arterial Morphometry From Microfocal X-Ray Computed Tomography, Kelly L. Karau, Robert C. Molthen, Anita H. Dhyani, Steven Thomas Haworth, Christopher C. Hanger, David L. Roerig, Roger H. Johnson, Christopher A. Dawson
Biomedical Engineering Faculty Research and Publications
The objective of this study was to develop an X-ray computed tomographic method for pulmonary arterial morphometry. The lungs were removed from a rat, and the pulmonary arterial tree was filled with perfluorooctyl bromide to enhance X-ray absorbance. At each of four pulmonary arterial pressures (30, 21, 12, and 5.4 mmHg), the lungs were rotated within the cone of the X-ray beam that was projected from a microfocal X-ray source onto an image intensifier, and 360 images were obtained at 1° increments. The three-dimensional image volumes were reconstructed with isotropic resolution with the use of a cone beam reconstruction algorithm. …
Dwell Fatigue I : Damage Mechanisms, Tarun Goswami
Dwell Fatigue I : Damage Mechanisms, Tarun Goswami
Biomedical, Industrial & Human Factors Engineering Faculty Publications
The mechanisms controlling deformation and failure under high temperature creep-fatigue conditions of materials are examined in this paper. The materials studied are solder alloys, copper alloys, low alloy steels, stainless steels, titanium alloys, and Ni-based alloys. The deformation and failure mechanisms were different (fatigue, creep, oxidation and their interactions) depending upon test and material parameters employed. Deformation mechanisms, such as cavity formation, grain boundary damage, intergranular (IG) and transgranular (TG) damage, oxidation, internal damage, dislocation cell concentration, and oxide mechanisms are very important in order to gain more knowledge of fatigue behavior of materials. The observed mechanisms can be categorized …
Quantification Of Pulmonary Arterial Wall Distensibility Using Parameters Extracted From Volumetric Micro-Ct Images, Roger H. Johnson, Kelly Lynn Karau, Robert C. Molthen, Christopher A. Dawson
Quantification Of Pulmonary Arterial Wall Distensibility Using Parameters Extracted From Volumetric Micro-Ct Images, Roger H. Johnson, Kelly Lynn Karau, Robert C. Molthen, Christopher A. Dawson
Biomedical Engineering Faculty Research and Publications
Stiffening, or loss of distensibility, of arterial vessel walls is among the manifestations of a number of vascular diseases including pulmonary arterial hypertension. We are attempting to quantify the mechanical properties of vessel walls of the pulmonary arterial tree using parameters derived from high-resolution volumetric x-ray CT images of rat lungs. The pulmonary arterial trees of the excised lungs are filled with a contrast agent. The lungs are imaged with arterial pressures spanning the physiological range. Vessel segment diameters are measured from the inlet to the periphery, and distensibilities calculated from diameters as a function of pressure. The method shows …
Mechanical Properties Of Dendritic Pd-Cu-Ga Dental Alloys, Efstratios Papazoglou, Qiang Wu, William A. Brantley, John C. Mitchell, Glyn Meyrick
Mechanical Properties Of Dendritic Pd-Cu-Ga Dental Alloys, Efstratios Papazoglou, Qiang Wu, William A. Brantley, John C. Mitchell, Glyn Meyrick
Cells and Materials
Three Pd-Cu-Ga dental alloys with very similar nominal compositions and dendritic as-cast microstructures were selected for study: Option (Ney Dental) and Spartan (Williams/lvoclar) contain a small amount of boron, while Spartan Plus (Williams/Ivoclar) is boron-free. Bars of each alloy were tested in tension for the as-cast and simulated porcelain-firing conditions, and values of mechanical properties were measured. Fracture surfaces and microstructures of axially sectioned and etched fracture specimens were observed with the scanning electron microscope (SEM). Except for the elastic modulus, significant differences were typically found in alloy properties. Heat treatment eliminated the dendritic microstructure, decreased strength and increased ductility. …
X-Ray Diffraction And Scanning Electron Microscopy Analyses Of A Gallium-Based Dental Restorative Alloy, Randa E. Shaker, William A. Brantley, Qiang Wu, John C. Mitchell
X-Ray Diffraction And Scanning Electron Microscopy Analyses Of A Gallium-Based Dental Restorative Alloy, Randa E. Shaker, William A. Brantley, Qiang Wu, John C. Mitchell
Cells and Materials
Specimens of a gallium-based dental alloy were prepared with different condensation techniques, with and without the removal of a surface layer, and after aging for 2 hours at 50°, 100° and 150°C. X-ray diffraction at times ranging from 10 minutes to 1 day showed the development of the four matrix phases (ß-Sn, CuGa2, Ga28Ag72, and In4Ag9) during the setting reaction. Scanning electron microscope (SEM) examination of specimens loaded to failure revealed brittle fracture, with greater porosity for hand-condensed specimens, and provided insight into crack propagation processes. Aging increased …
Quantifying The Surface Geometry Of Titanium Implant Material By Different Methods Of Analysis, Clara Pimienta, Rashad Tawashi
Quantifying The Surface Geometry Of Titanium Implant Material By Different Methods Of Analysis, Clara Pimienta, Rashad Tawashi
Cells and Materials
Biomaterial implant manufacturers have used rough surfaces to ensure better biocompatibility, less rejection and better adaptation of implants in the body. Proper characterization of biological interactions and biocompatibility of biomaterials requires a thorough understanding of surface complexity. Surface roughness has often been shown to be important in influencing biological reactions with the surface. Previous communications from our laboratory have described a dynamic active vision system (MVS camera) capable of measuring three-dimensional coordinates of titanium implant material surfaces. Fractal analysis, due to its straightforward relationship to texture, is used to characterize the degree of irregularity of a surface and is expressed …
Transition Criteria - From A Pit To A Crack, Tarun Goswami, David W. Hoeppner
Transition Criteria - From A Pit To A Crack, Tarun Goswami, David W. Hoeppner
Biomedical, Industrial & Human Factors Engineering Faculty Publications
A brief review of pitting, which is a localized corrosion process resulting from pitting and fatigue interaction has been conducted in this paper. The transition of a pit to a crack is a very important phenomenon occurring under PCF conditions. Various theories for transition of a pit to a crack were examined within the limits of present understanding and limitations of the models. The transition of a pit to a crack was also discussed for a variety of pit shapes utilizing the pit aspect ratios, defect size and linear elastic fracture mechanics, crack tip characterizing parameters such as Mode I …
Optimization Of Insertion Holes And Anchor Design For Cylinder Shaped Toggle Type Suture Anchors, Adam Fedenia
Optimization Of Insertion Holes And Anchor Design For Cylinder Shaped Toggle Type Suture Anchors, Adam Fedenia
Masters Theses
This research was performed to optimize insertion holes and anchor design for cylinder shaped toggle type suture anchors. Four types of anchors were investigated in terms of pull strength and design in acrylic plate and pig bone. They included small type A and B anchors and large type A and B anchors.
Pull strength trends suggest that the small type anchors behave similarly since their external dimensions are identical, with the exception of type A anchor having a hole running from one end of the cylinder to the other like a pipe. It was found that the suture would fail …
Tissue Engineering: At The Interface Between Engineering, Biology And Medicine, Brenda Ogle, Priti Gairola, Jodi Balik, Daniel L. Mooradian
Tissue Engineering: At The Interface Between Engineering, Biology And Medicine, Brenda Ogle, Priti Gairola, Jodi Balik, Daniel L. Mooradian
Journal of the Minnesota Academy of Science
No abstract provided.