Open Access. Powered by Scholars. Published by Universities.®
- Institution
-
- California Polytechnic State University, San Luis Obispo (61)
- Michigan Technological University (35)
- New Jersey Institute of Technology (31)
- Utah State University (30)
- Wright State University (29)
-
- Clemson University (25)
- University of Nebraska - Lincoln (19)
- University of Arkansas, Fayetteville (18)
- Al Esraa University (16)
- Missouri University of Science and Technology (16)
- Raynor Library Marquette University (16)
- Yıldız Technical University (13)
- Cleveland State University (12)
- University of South Florida (12)
- Louisiana Tech University (11)
- The University of Akron (10)
- Virginia Commonwealth University (10)
- Old Dominion University (8)
- Rowan University (8)
- Tashkent State Technical University (8)
- University of Kentucky (8)
- Boise State University (7)
- Florida Institute of Technology (7)
- Wayne State University (7)
- Louisiana State University (6)
- Purdue University (6)
- Technological University Dublin (6)
- University of Louisville (6)
- University of Mississippi (6)
- Santa Clara University (5)
- Keyword
-
- Corrosion (18)
- Department of Biomedical Engineering (17)
- Biomaterials (15)
- Biocompatibility (11)
- Magnesium (11)
-
- Microstructure (11)
- Engineering (10)
- Implants (10)
- Microfluidics (10)
- Stent (10)
- Tissue engineering (10)
- Titanium (10)
- Applied sciences (9)
- Biosensors (9)
- Biodegradable (8)
- Mechanical engineering and machinery (8)
- TJ1-1570 (8)
- Bone (7)
- Mechanical properties (7)
- Zinc (7)
- Biofilm (6)
- Biomechanics (6)
- Biomedical (6)
- Biomedical engineering (6)
- Bioreactor (6)
- Dental alloy (6)
- Department of Biomedical, Industrial & Human Factors Engineering (6)
- Nanotechnology (6)
- Prosthesis (6)
- Prosthetic (6)
- Publication Year
- Publication
-
- Theses and Dissertations (30)
- Theses (27)
- Biomedical Engineering (26)
- Master's Theses (22)
- Biomedical, Industrial & Human Factors Engineering Faculty Publications (21)
-
- Cells and Materials (19)
- Al-Esraa University College Journal for Engineering Sciences (16)
- All Dissertations (16)
- Biomedical Engineering Faculty Research and Publications (15)
- Chemical and Biochemical Engineering Faculty Research & Creative Works (14)
- Journal of Sustainable Construction Materials and Technologies (13)
- Michigan Tech Publications, Part 1 (13)
- Dissertations, Master's Theses and Master's Reports (12)
- USF Tampa Graduate Theses and Dissertations (12)
- Doctoral Dissertations (11)
- Graduate Theses and Dissertations (11)
- ETD Archive (10)
- Electronic Theses and Dissertations (10)
- Williams Honors College, Honors Research Projects (10)
- Browse all Theses and Dissertations (8)
- Honors Theses (8)
- Technical science and innovation (8)
- All Theses (7)
- Department of Agricultural and Biological Systems Engineering: Faculty Publications (7)
- All Graduate Theses and Dissertations, Spring 1920 to Summer 2023 (6)
- Dissertations (6)
- Mechanical Engineering (6)
- Materials Engineering (5)
- Mechanical and Biomedical Engineering Faculty Publications and Presentations (5)
- Articles (4)
- Publication Type
Articles 481 - 510 of 529
Full-Text Articles in Entire DC Network
Mechanical Evaluation Of Pedicle Screw Fixation Of The Lumbar Spine, Ding Lu
Mechanical Evaluation Of Pedicle Screw Fixation Of The Lumbar Spine, Ding Lu
Theses
Pedicle screw fixation of the lumbar spine has been reported to increase fusion rates A biomechanical evaluation of four different pedicle screw implant systems, (AO. Rogozinski, TSRH and Wiltse). was performed to compare intrinsic device stiffness under conditions of flexion-compression and forty-five degree off-axis flexion-compression The effect on stiffness of the loosening of device members was also studied. Testing was done in load control using an electrohvdrualic testing machine. UHMWPe blocks are used to simulate the vertebra.
Assuming that stiffness is directly proportional to the probability of obtaining fusion. this study allows the ranking of the systems tested in their …
Three-Dimensional Stress Analysis Of The Femur With Prosthetic Hip Stem Utilizing Computed Tomography Scans Of The Femur For Geometry And Material Properties, Thomas J. Lavin
Theses
Three-dimensional finite element stress analyses of the femur with prosthesis hip stem were performed for two cases, one male and one female, using ideally bonded cemented titanium prostheses. Computed tomography data files were used to derive the three-dimensional femur geometry and material properties for each cortical bone element. The maximum shear stress (4.7 MPa) in the cement was greater then the maximum tensile stress and occurred at the cement-bone interface. The tensile stresses in the cement were less then the fatigue strength of the cement. The stress patterns were quite similar for the two cases.
A data analysis program was …
Corrosion Of Metal Hip Arthroplasties And Its Possible Role In Loosening, H. K. Koerten, J. J. A. M. Van Raay, J. J. M. Onderwater, F. P. Bernoski, P. M. Rozing
Corrosion Of Metal Hip Arthroplasties And Its Possible Role In Loosening, H. K. Koerten, J. J. A. M. Van Raay, J. J. M. Onderwater, F. P. Bernoski, P. M. Rozing
Cells and Materials
Tissue removed with human hip arthroplasties during revision surgery of 45 patients was evaluated by transmission electron microscopy and X -ray microanalysis (XRMA). The results show that microscopic and submicroscopic particles are abundantly present in the tissue at the tissue/implant interface. XRMA of individual particles shows that the chemical composition of a portion of the particles was in agreement with that of the retrieved implants. Regularly, particulates with a dissimilar chemical composition were found. Sometimes, these particles could be recognized as filler particles of the cements used. Other particles could partly or completely be composed of the chemical elements that …
Heat-Treatment Behavior Of High-Palladium Dental Alloys, Qiang Wu, William A. Brantley, John C. Mitchell, Stanley G. Vermilyea, Jianzhong Xiao, Wenhua Guo
Heat-Treatment Behavior Of High-Palladium Dental Alloys, Qiang Wu, William A. Brantley, John C. Mitchell, Stanley G. Vermilyea, Jianzhong Xiao, Wenhua Guo
Cells and Materials
Four high-palladium dental alloys were cast, quenched following solidification, and heat treated at temperatures ranging from 200° to 1,800°F. The Vickers hardness of each alloy was measured, and microstructural changes were studied by scanning electron microscopy (SEM). Phase transformations were investigated by thermomechanical analysis (TMA). Heat treatment at 1,600° and 1,800°F significantly decreased the hardness of one Pd-Cu-Ga alloy, compared to the as-cast condition, as did heat treatment at 1,800°F for the other Pd-Cu-Ga alloy and one Pd-Ga alloy, and yielded fine-grained microstructures of the palladium solid solution. There were generally no significant changes in the hardness of the other …
Mechanism For Formation Of Lamellar Constituents In Grain-Refined Pd-Cu-Ga Dental Alloys, William A. Brantley, Zhuo Cai, John C. Mitchell, Stanley G. Vermilyea
Mechanism For Formation Of Lamellar Constituents In Grain-Refined Pd-Cu-Ga Dental Alloys, William A. Brantley, Zhuo Cai, John C. Mitchell, Stanley G. Vermilyea
Cells and Materials
Grain-refined Pd-Cu-Ga dental alloys solidify with a lamellar microstructural constituent that affects a variety of clinically relevant properties. While formation of this constituent has been attributed to eutectic solidification, an alternative mechanism of discontinuous precipitation has been proposed. Using a representative grain-refined Pd-Cu-Ga dental alloy, casting procedures involving two different rates of solidification were used: (a) A standard thin-walled coping configuration for a metal-ceramic restoration was cast into a room temperature mold, followed by rapid quenching into an ice-water mixture. (b) A thin plate specimen was cast into a standard elevated-temperature mold, with the same subsequent rapid quenching procedure. Neither …
Biofilms In Dental Unit Waterlines: Ultrastructural And Cytochemical Analysis, J. Barbeau, C. Avezard, E. Faucher, S. Zalzal, A. P. Prévost
Biofilms In Dental Unit Waterlines: Ultrastructural And Cytochemical Analysis, J. Barbeau, C. Avezard, E. Faucher, S. Zalzal, A. P. Prévost
Cells and Materials
Dental unit waterlines are heavily colonized by bacteria which contaminate the water used to perform intra-oral, and sometimes invasive, procedures. There is little information on the nature of the biofilm colonizing the flexible plastic tubing used to supply water to the different handpieces. We have therefore undertaken quantitative microbial analysis and ultrastructural studies of these biofilms by direct counting with the epifluorescent filter technique and by transmission and scanning electron microscopy after staining with ruthenium red and periodic acid-thiosemicarbazide-silver proteinate to visualize the composition and the distribution of exopolysaccharides and intracellular polysaccharides. The biofilm was revealed as a non-uniform structure …
A New Model Of High Temperature Low Cycle Fatigue Life Prediction - Applicability With Low Alloy Steels, Tarun Goswami
A New Model Of High Temperature Low Cycle Fatigue Life Prediction - Applicability With Low Alloy Steels, Tarun Goswami
Biomedical, Industrial & Human Factors Engineering Faculty Publications
Creep-fatigue data on low alloy steels were collected from National Research Institute for Metals (NRIM) Tokyo, Japan. These data were generated for lCr-Mo-V, 2.25Cr-Mo, and 9Cr-lMo steels under a wide range of test conditions. A new creep-fatigue life prediction method was developed and data compiled were assessed to examine the applicability of the new method. A brief review of the empirically based, phenomenological life prediction methods was presented where no method was found to be applicable universally to all the creep-fatigue data. The new model was developed within the viscosity concepts, in which the damage parameter was accounted for in …
Review Of Pit Nucleation, Growth And Pitting Corrosion Fatigue Mechanisms, Tarun Goswami, D. W. Hoeppner
Review Of Pit Nucleation, Growth And Pitting Corrosion Fatigue Mechanisms, Tarun Goswami, D. W. Hoeppner
Biomedical, Industrial & Human Factors Engineering Faculty Publications
This paper presents a review of the state of the art developments in the pitting corrosion fatigue of aircraft structural materials. Mechanisms that govern the nucleation and growth of pitting and corrosion fatigue (CF) are briefly addressed. Some of the developments made in the author's laboratories in proposing the fretting induced pit nucleation and growth mechanisms, analysis of the hidden corrosion constituents in fuselage joints and pitting corrosion fatigue crack growth (PCFCG) model are elucidated. An epistemology of the topic is presented which will be of assistance to the community working in this area.
Corrosion Fatigue Crack Growth Behavior Of Aircraft Materials, Tarun Goswami, D. W. Hoeppner
Corrosion Fatigue Crack Growth Behavior Of Aircraft Materials, Tarun Goswami, D. W. Hoeppner
Biomedical, Industrial & Human Factors Engineering Faculty Publications
The effects of test parameters on the corrosion fatigue crack growth behavior of structural materials have been examined in this paper. Test parameters such as stress ratio, frequency, hold time, temperature, pH level of the media, and other parameters are known to alter the corrosion fatigue crack growth rates in structural materials. Numerous laboratory test variables that affect the crack growth and/or corrosion growth rates, which in an operating environment of an aircraft are not characterized, are reviewed. A summary of such information may help determine the inspection intervals of the new and aged airplanes, perform the inspections, and develop …
The Effects Of Machining On Structure And Tribological Properties Of Ultra High Molecular Weight Polyethylene For Artificial Joint Prostheses, Jinshan Song
Masters Theses
Understanding the effect of machining on the structure and property of subsurface layer of ultra high molecular weight polyethylene (UHMWPE) can significantly facilitate the increase in longevity of artificial joints. This study was performed to investigate the machining effects on the polymeric structure and tribological properties. Machining parameters include cutting speed, tool feed rate and depth of cut. Temperature rise was studied during machining to assess the extent of thermal degradation due to machining. Polymeric structure of the semicrystalline polymer was characterized using differential scanning calorimetry (DSC) in terms of melting enthalpy, crystallinity and melting temperature. Surface texture and hardness …
Development Of A Gel Content Analysis Protocol For Ultra High Molecular Weight Polyethylene, Max Harold Jeanty
Development Of A Gel Content Analysis Protocol For Ultra High Molecular Weight Polyethylene, Max Harold Jeanty
Theses
A modified procedure based upon ASTM (D 2765 - 90) to determine the gel content of crosslinked polyethylene plastics was developed. The new procedure was applied to ram extruded Ultra High Molecular Weight (UHMWPE) implant components processed under different manufacturing conditions. This new evaluation tool provides consistent results with greater accuracy and consistency compared to the American Society for the Testing of Materials (ASTM) method. Using the same tool, several relationships between the UHMWPE processing conditions and gel content were established. The amount of gel content is related to the crosslinked material. It has been shown that the more crosslinking …
The In Vitro Evaluation Of Various Biodegradable Composites Used In Internal Fixation Devices, Hui-Chen Hsieh
The In Vitro Evaluation Of Various Biodegradable Composites Used In Internal Fixation Devices, Hui-Chen Hsieh
Theses
In vitro degradation kinetics and mechanical properties of various composites, comprising a polycarbonate (DTE polymer) reinforced with CaP glass fiber, synthetic ceramic and non-ceramic hydroxyapatite (HA-500,OsteoGen HA) were investigated.
They were soaked in the SBF solution with a constant pH of 7.4 at 37°C for 5 days. The DTE/CaP composite degraded in an acid manner such that a large amount of NaOH was required but with a small decrease in calcium ion concentration. By contrast, the DTE/OsteoGen HA composite required comparable amounts of NaOH, but with a concomitantly large decrease in calcium ion concentration. This showed that the OsteoGen HA …
Improved Conversion Of Plant Oils And Animal Fats Into Biodiesel And Co-Product , Praveen R. Muniyappa, Scott C. Brammer, Hossein Noureddini
Improved Conversion Of Plant Oils And Animal Fats Into Biodiesel And Co-Product , Praveen R. Muniyappa, Scott C. Brammer, Hossein Noureddini
Papers in Biomaterials
Increased environmental awareness and depletion of resources are driving to develop alternative fuel from renewable resources that are environmentally more acceptable. Esters of fatty acids (bio-diesel, derived from the transesterification vegetable oils, have properties similar to components of peh-oleior~. based diesel fuel Cost has been a major factor slowing the commercializatio of bio-diesel! Glycerol is the coproduct of the esterification process. In this work the feasibility of the glyc-erol of vegetable oil. with crude glycerol derived from the transesterification of the vegetable oils and animal fats was studied. Utilization of the crude co-product of the biodiesel process was investi-gated for …
Armature Position Sensor For A Relay, G. Stephen Perreira, Richard L. Kutin, Lanny V. Griffin
Armature Position Sensor For A Relay, G. Stephen Perreira, Richard L. Kutin, Lanny V. Griffin
Biomedical Engineering
A sensor for use with high-power solenoid-actuated relays, and for detecting and signalling relay armature position and hence the actuation state of the relay. The sensor is external to a sealed chamber in which the relay contacts and armature system are positioned, and includes a permanent magnet, the flux path of which includes the relay armature and base. Armature movement to close the relay alters the flux path to operate a reed switch adjacent the magnet, and the condition of the reed switch signals the unactuated or actuated state of the relay.
Laboratory Growth Systems In Biofilm Research, Julian W. T. Wimpenny
Laboratory Growth Systems In Biofilm Research, Julian W. T. Wimpenny
Cells and Materials
The huge variety of ecosystems that we collectively refer to as "biofilm" is reflected by the numerous different systems available to grow them in the laboratory. The relationship between in situ systems, microcosms and laboratory models is defined and discussed. The first two represent holistic approaches designed to assess the structure and function of particular biofilms: the last is analytical and reductionist, aiming to isolate specific functions of biofilms in order to understand properties that can apply to biofilm in general. Properties of a model can be completely understood whilst this is unlikely with natural ecosystems because of the possibility …
Effects Of Solidification Conditions And Heat Treatment On The Microstructure And Vickers Hardness Of Pd-Cu-Ga Dental Alloys, William A. Brantley, Zhuo Cai, Stanley G. Vermilyea, Efstratios Papazoglou, John C. Mitchell, Alan B. Carr
Effects Of Solidification Conditions And Heat Treatment On The Microstructure And Vickers Hardness Of Pd-Cu-Ga Dental Alloys, William A. Brantley, Zhuo Cai, Stanley G. Vermilyea, Efstratios Papazoglou, John C. Mitchell, Alan B. Carr
Cells and Materials
Two representative Pd-Cu-Ga dental alloys, one with a dendritic as-cast microstructure containing a eutectic interdendritic constituent and the other with an equiaxed fine-grained as-cast microstructure containing a near-surface eutectic constituent, have been subjected to rapid quenching following casting, in addition to the conventional bench cooling recommended by the manufacturers. The quenched alloys were subsequently heat treated at temperatures of 1200°, 1500° and 1800 op that span the range of the firing cycles for dental porcelain. Scanning electron microscopic examination showed that the lamellar eutectic constituents normally present in the microstructures of the as-cast and bench-cooled alloys persisted when the alloys …
Heterogeneity Of Natural Biofilm Communities, J. R. Lawrence, D. R. Korber, G. M. Wolfaardt
Heterogeneity Of Natural Biofilm Communities, J. R. Lawrence, D. R. Korber, G. M. Wolfaardt
Cells and Materials
Scanning confocal laser microscopy (SCLM) studies have shown that microbial biofilms consist of a spatially heterogeneous arrangement of bacterial cells, biogenic extracellular material, and void space. Biofilm architecture is dominated by the presence of cell aggregates interspersed by channels, the arrangement of which varies for different hydrodynamic regimes, ages, species composition, or nutrient status. This organization may regulate the flux of nutrients and oxygen, creating chemical microenvironments (Eh, pH) facilitating the growth of aerobic heterotrophs and anaerobes. The presence of microenvironments has been confirmed using laser microscopy and environmentally sensitive fluorescent probes. In addition, changes in cell number and growth …
Pelargonic Acid In Enhanced Oil Recovery, Hossein Noureddini, M L. Rempe
Pelargonic Acid In Enhanced Oil Recovery, Hossein Noureddini, M L. Rempe
Papers in Biomaterials
Oxidation of monounsaturated iatty ac~dss,u ch as erucic and oleic acids, results in the for~nation of dibasic fatty acids, such as brassylic and azelaic acids. Dibasic acids find many inclustrial applications. Prlargon~ca cid is the co-product oi the process. Expanded use oi dibasic acids would require an expansion in the existing and possihiy new uses for pelargoriic acid and its derivatives. In this study, the potential for using pe!argonic acid in enhanced oil recovery is investigated. Experimental results are presented ior the enhanccd oil recover" by waterilooding with the aid oi a surfactan;. In sifu iormation of surfactant at the …
Corrosion And Protection Of A Conductive Silver Paste, V. Brusic, G. S. Frankel, J. Roldan, Ravi F. Saraf
Corrosion And Protection Of A Conductive Silver Paste, V. Brusic, G. S. Frankel, J. Roldan, Ravi F. Saraf
Ravi Saraf Publications
One of the possible uses for a conductive paste is as an adhesive in interconnect technology that could replace PbSn solder. The interconnections are expected to perform under a variety of environmental conditions, and with an applied voltage. Thus knowledge of their corrosion and dissolution resistance is of utmost importance. This is a study of the dissolution and protection of polymer/metal composite films, prepared with a high loading of silver or gold particles. Electrochemical tests were conducted in a droplet of triple-distilled water with or without benzotriazole (BTA) and BTA derivatives. Results indicate that, in spite of some protection obtained …
Effect Of Fiber-Matrix Coupling On The Mechanical Properties Of A Totally Bioabsorbable Composite, Barbaro Jesus Perez
Effect Of Fiber-Matrix Coupling On The Mechanical Properties Of A Totally Bioabsorbable Composite, Barbaro Jesus Perez
Theses
The mechanical properties of a new class of bioabsorbable polymer-composite based on the amino acid tyrosine and calcium phosphate fibers were studied. The effect of the fiber aspect ratio on the elastic modulus of a discontinuous fiber composite was analyzed using the SMC composite micromechanics computer model. The mechanical stiffness of this polymer was found to be superior to that of poly-p-dioxanone, caprolactone and poly-o-ester.
The fiber surface was modified with methane plasma spray to improve the fiber-matrix coupling. The treated fiber composites had 16-40% higher tensile modulus than the untreated fiber composites. From the flexural test results it is …
Wear And Friction Of Hylamer And Polyethylene Against Cobalt Chromium A Pin-On-Disc Study, Jerry D'Alessio, Ii
Wear And Friction Of Hylamer And Polyethylene Against Cobalt Chromium A Pin-On-Disc Study, Jerry D'Alessio, Ii
Theses
Understanding friction and wear of biomaterials is essential to the success of any prosthetic joint. A pin-on-disc wear tester is used to find the friction and wear of pins of one material on a coupon of medical grade cobalt chrome. In this experiment six pins of UHMWPe (ultra high molecular weight polyethylene) and six pins of Hylamer® from Du Pont Manufacturing were tested. Four separate runs were made. The tests were performed for ten million cycles, stopping every one to one and a half million cycles for data acquisition. Volumetric wear, wear rate, and coefficients of friction were measured. Both …
Wear Of Polyethylene And Hylamer On Cobalt-Chromium : A Knee Simulator Study, Alessandro F. Canonaco
Wear Of Polyethylene And Hylamer On Cobalt-Chromium : A Knee Simulator Study, Alessandro F. Canonaco
Theses
Two tests were conducted to examine the wear characteristics of tibial bearings used in total knee replacement systems. Each test consisted of six A/P Glide Tibial Bearings each having a conical control arm. The plastic portion of the conical bearings were all made of UHMWPe. Each of these bearing systems was mounted onto a Co-Cr alloy tibial platform and Co-Cr alloy LCS (low contact stress) femoral component . These test samples were mounted onto the New Jersey Mark III Knee Simulator System. The simulator was configured to produce flexion and axial rotation to simulates normal gait. Each test ran at …
Room Temperature Aging Of Pd-Cu-Ga Dental Alloys, William A. Brantley, Zhuo Cai, Qiang Wu, Alan B. Carr, John C. Mitchell
Room Temperature Aging Of Pd-Cu-Ga Dental Alloys, William A. Brantley, Zhuo Cai, Qiang Wu, Alan B. Carr, John C. Mitchell
Cells and Materials
Specimens of three Pd-Cu-Ga dental alloys cast five years ago and subsequently stored at room temperature were reexamined and observed to have lower amounts of the eutectic constituents in the near-surface region than originally present, along with other microstructural changes. This previously unreported room temperature aging behavior of these alloys is attributed to the presence of high-diffusivity paths in the non-equilibrium ascast eutectic structures and to the essential role of the surface for the vacancy diffusion mechanism. These results may have important clinical significance for the ill vivo corrosion resistance and long-term biocompatibility of the Pd-Cu-Ga alloys.
Reliability Of Human Fresh And Frozen Gingiva Explant Culture In Assessing Dental Materials Cytocompatibility, R. Warocquier-Clerout, G. C. Hachom-Nitcheu, M. F. Sigot-Luizard
Reliability Of Human Fresh And Frozen Gingiva Explant Culture In Assessing Dental Materials Cytocompatibility, R. Warocquier-Clerout, G. C. Hachom-Nitcheu, M. F. Sigot-Luizard
Cells and Materials
An explant culture of human gingival epithelium has been set up in order to provide a valuable test for evaluating the cytocompatibility of dental material s. In an attempt to supply a bank of gingiva ex plants, frozen and freshly excised specimens were cultured in parallel. Optical and scanning electron microscopy showed an early release of cuboidal cells forming a dense layer around the explants. Afterwards, cultures evolved differently . Spread cells grew and migrated more rap idly in fresh than in frozen explant cultures but their adhesion to substratum increased earlier in frozen ones. Epithelial phenotype of cells had …
Some Biological And Physical Properties Of Laser Deposited Hydroxyapatite Based Films, Tatjana Dostalova, Lucie Himmlova, Miroslav Jelinek, Jirina Bartova
Some Biological And Physical Properties Of Laser Deposited Hydroxyapatite Based Films, Tatjana Dostalova, Lucie Himmlova, Miroslav Jelinek, Jirina Bartova
Cells and Materials
The preliminary results of biological and physical tests of hydroxyapatite thin films deposited on dental implants by a new technology with the KrF excimer laser ablation method were evaluated. Biological and physical properties were studied and analyzed by the lymphocyte proliferation test and scanning electron microscopy (SEM), X-ray analysis, Rutherford backscattering analysis (RBS) and particle induced X-ray emission (PIXE) methods. Ten bioceramic films from 45 samples had very good physical and biological properties. Creation of hydroxyapatite thin films with laser ablation can have a positive effect on adhesion of the film and protection for corrosion.
Characterization And Redesign Of The Afit Multielectrode Array, Richard G. Darenberg Jr.
Characterization And Redesign Of The Afit Multielectrode Array, Richard G. Darenberg Jr.
Theses and Dissertations
Since 1978, faculty and graduate students from the Air Force Institute of Technology (AFIT) have been working on an implantable circuit array that can record visual signals from the brain or stimulate the brain. In the current design the circuit is a 16 x 16 array of pads, each pad being 160 x 160 micrometers with 250 micrometers spacing with an 'L' shaped reference pad used as a ground reference. The array is multiplexed so that only one I-O line is required to access all 256 pads. This research was twofold: first to analyze the existing circuit and identify sources …
An Analysis Of A Custom Expanding Total Femoral Prosthesis With A Rotating Hinge Knee, Ramarao Gundlapalli, V. Gundlapalli
An Analysis Of A Custom Expanding Total Femoral Prosthesis With A Rotating Hinge Knee, Ramarao Gundlapalli, V. Gundlapalli
Theses
Osteosarcoma is the most common malignant bone tumor in the pediatric age group. This thesis presents the analysis of a total femoral prosthesis implanted in a 9 year old black male. The design includes a bipolar, expanding mid-shaft component, and a rotating hinge knee used in the reconstruction of the patient's right lower limb after surgical resection of the femur. The areas being analyzed are (i) the trochanteric attachment, (ii) the expanding component, and (iii) the rotating hinge knee. The stresses acting on the cables reconnecting the greater and lesser trochanter were determined for bipedal stance, single-legged stance, stance phase …
An Experimental Investigation Of Wear Behavior Of Ultra-High Molecular Weight Polyethylene Under Sliding Motion, Elham Zand-Moghaddam
An Experimental Investigation Of Wear Behavior Of Ultra-High Molecular Weight Polyethylene Under Sliding Motion, Elham Zand-Moghaddam
Theses
This project investigates the effect of sliding motion on the materials that are used as bearing surfaces of human total-joint replacement prostheses.
The tests are performed with a specially designed equipment based on pin-on-disk machine. The testing machine is designed and constructed to reproduce sliding motion, applied to spherical ended metal "Canine-Head" components such as dog hip acting on a flat polyethylene surface. The sliding motion is performed by applying different constant loads for 5,000,000 cycles. The tests are carried out with the wear specimen lubricated by deionized water.
The purpose is to produce delamination, which is the severe wear …
Evaluation Of Drug Delivery Systems By Electron Microscopy Techniques, Y. V. Pathak, V. D. Labhashetwar
Evaluation Of Drug Delivery Systems By Electron Microscopy Techniques, Y. V. Pathak, V. D. Labhashetwar
Cells and Materials
This review covers the applications of electron microscopic techniques to the characterization and evaluation of drug delivery systems. Various electron microscopic (EM) related techniques such as transmission electron microscopy, scanning electron microscopy (SEM), SEM with energy dispersive X-ray microanalysis, and freeze-fracture electron microscopy are extensively used for this purpose. Microcapsules, microspheres, nanocapsules, liposomes , polymeric carriers and other drug delivery systems are characterized using EM related techniques for their surface topography, size and shape analysis, biodegradation, in vitro - in vivo evaluation and drug excipient interactions and characterization. Electron microscopy methods are very useful in understanding the mechanism of drug …
In-Vivo Reactions In Some Bioactive Glasses And Glass-Ceramics Granules, A. M. Gatti, T. Yamamuro, L. L. Hench, O. H. Andersson
In-Vivo Reactions In Some Bioactive Glasses And Glass-Ceramics Granules, A. M. Gatti, T. Yamamuro, L. L. Hench, O. H. Andersson
Cells and Materials
Two different bioactive glasses and one glass-ceramic were implanted as granules for 2 months in rabbit muscle and for 5 months in sheep jaw in order to study the influence of the biological surroundings on the reactions of the materials.
Scanning electron microscope and energy dispersive X-ray microanalysis showed that a calcium and phosphorous-rich (CaP) surface layer (adjacent to a silicon rich-layer) forms on both glasses in both implantation sites. The glass-ceramic developed only a CaP layer. A chemical process of degradation was more evident in muscle, even though the implantation time was shorter than that in bone. For all …