Open Access. Powered by Scholars. Published by Universities.®

Digital Commons Network™

Open Access. Powered by Scholars. Published by Universities.®

Biomedical Engineering and Bioengineering

Institution
Keyword
Publication Year
Publication
Publication Type
File Type

Articles 421 - 450 of 529

Full-Text Articles in Entire DC Network

Development Of A Device For Whole Body Stimulation Of The Otoliths, Jon Edward Weimer Jan 2010

Development Of A Device For Whole Body Stimulation Of The Otoliths, Jon Edward Weimer

Theses

Over the past few decades, research has been conducted to explore the effects of microgravity on human musculature, As seen in astronauts upon their return to Earth after prolonged spaceflight, extensive muscle atrophy due to adaptation to conditions of microgravity many times decreases a person's ability to walk or even stand, With an understanding of the anatomical mechanisms that provide postural control, the proper stimulation, resulting in a reduction in spasticity, could be provided by simulating these conditions of microgravity.

In order to simulate microgravity, a device has been developed that is capable of providing whole body stimulation of the …


Application Of Differential Scanning Calorimetry To Characterize Thin Film Deposition Processes, Andrew John Roger Snell Jan 2010

Application Of Differential Scanning Calorimetry To Characterize Thin Film Deposition Processes, Andrew John Roger Snell

ETD Archive

With the recent increase in awareness on the environmental impact of industrial coating processes, chromate-based coating processes have been elevated to the rank of the technologies targeted by the EPA for rapid replacement by environmentally friendly processes. Therefore, there is a clear need for advances in coating technologies to identify alternative industrial practices. This thesis characterizes a process developed at Cleveland State University as an alternative deposition technique to generate uniform coatings onto solid substrates. A kinetic analysis to extract scale up parameters involved in the reaction kinetics leading to high-performance coatings is demonstrated in this research. The work consists …


A Biomechanical Comparison Of Locking Compression Plate Constructs With Plugs/Screws In Osteoporotic Bone Model, Krishna P. Desai Jan 2010

A Biomechanical Comparison Of Locking Compression Plate Constructs With Plugs/Screws In Osteoporotic Bone Model, Krishna P. Desai

Browse all Theses and Dissertations

Locking compression plates are proven to be safe for use in open reduction and internal fixation (ORIF) especially in osteoporotic bones. Because of various combinations of holes, the system provides more options for clinicians to use either locking screws or non-locking screws. This clinical research introduces screw like plugs which can be used along with the screws in case of locking compression plates. Experimental work was performed to determine the effectiveness of the plugs. The results showed that there is not a significant difference between the groups which used plugs and did not use the plugs, both in case of …


Drug-Eluting Stents For Coronary Artery Disease: A Review, David Martin, Fergal Boyle Jan 2010

Drug-Eluting Stents For Coronary Artery Disease: A Review, David Martin, Fergal Boyle

Articles

Over the past decade the introduction of drug-eluting stents (DESs) has revolutionised the treatment of coronary artery disease. However, in recent years concern has arisen over the long-term safety and efficacy of DESs due to the occurrence of late adverse clinical events such as stent thrombosis. With this concern in mind, research and development is currently centred on increasing the long-term safety and efficacy of DESs. The aim of this paper is to provide a thorough review of currently approved and promising investigational DESs. With dozens of companies involved in the development of new and innovative anti-restenotic agents, polymeric coatings …


Creation Of Bioactive Surfaces To Modulate Cell Behavior Using Surface Initiated Photoiniferter-Mediated Graft Photopolymerization, Nihar Shah Dec 2009

Creation Of Bioactive Surfaces To Modulate Cell Behavior Using Surface Initiated Photoiniferter-Mediated Graft Photopolymerization, Nihar Shah

All Dissertations

Biomaterials widely used in biomedical applications still face biocompatibility issues arising from non-specific protein adsorption on the foreign surface, and the consequent undesired cell response. Emerging evidence suggests that imparting specific bioactivity to the biomaterial's surface to elicit favorable response from cells, (like osseointegration of joint implants and endothelialization of stents) can yield much better biocompatibility results when combined with passive prevention of protein adsorption. In more complex diseases like spinal cord injury and cardiomyopathy, specific biomolecules are required to elicit desired cell responses for successful regeneration. However, for success of such biomolecule based strategies, the effects of various parameters …


Fabrication And Characterization Of Bioactive, Composite Electrospun Bone Tissue Engineering Scaffolds Intended For Cleft Palate Repair, Parthasarathy Madurantakam Jul 2009

Fabrication And Characterization Of Bioactive, Composite Electrospun Bone Tissue Engineering Scaffolds Intended For Cleft Palate Repair, Parthasarathy Madurantakam

Theses and Dissertations

Tissue Engineering is a scientific discipline that aims to regenerate tissues and organs that are diseased, lost or congenitally absent. It encompasses the use of suitable synthetic equivalents of native extracellular matrix that may or may not be supplemented with cells or relevant growth factors. Such scaffolds are designed to reside at the site of implantation for a variable period of time during which they induce the regeneration of native tissue. During this time, they also provide a template for new cells to attach, infiltrate, differentiate into appropriate phenotype and eventually restore function of the concerned tissue. Among the factors …


The Effect Of Particle Surface Area To Volume Ratio On Ion Release From Cocr Spheres, Darin J. Grandfield Jun 2009

The Effect Of Particle Surface Area To Volume Ratio On Ion Release From Cocr Spheres, Darin J. Grandfield

Master's Theses

In 2005, over 200,000 Americans underwent a hip arthroplasty, the replacement of a hip joint with an artificial prosthesis. Of these arthroplasties, metal-on-metal type implants represent an increasing usage percentage. Metal-on-metal implants are selected largely for their low volumetric wear rate, durability, and resistance to corrosion. In spite of these advantages, little is known concerning the long-term consequences of heavy metal alloy use in the body, although early research indicates potentially carcinogenic results. This thesis is a preliminary investigation into these long term effects and their root causes.

An improved comprehension of the corrosion kinetics and the rate of ion …


Evaluating The Electrical Response Of Polyaniline To Mechanical Strain, Matthew L. Goebel Jun 2009

Evaluating The Electrical Response Of Polyaniline To Mechanical Strain, Matthew L. Goebel

Master's Theses

This thesis focuses on the electrical output of polyaniline films subjected to uniaxial strain in hydrochloric acid solutions. Polyaniline belongs to novel class of materials known as conducting polymers. Alternating single and double bonds in the backbone of conducting polymers allow them to transmit electric charge when they are doped with negatively charged ions. Modifying the degree of doping and other electrical/chemical treatments allow conducting polymers to exhibit conducting, semi-conducting, or insulating electrical properties. Resilient mechanical properties, good processability, and low cost make conducting polymers good candidates for applications traditionally held by metals and semi-conductors.

When tensile strain is applied …


Fatigue Strength Of Common Tibial Intramedullary Nail Distal Locking Screws, Lanny V. Griffin, Robert M. Harris, Joseph J. Zubak Apr 2009

Fatigue Strength Of Common Tibial Intramedullary Nail Distal Locking Screws, Lanny V. Griffin, Robert M. Harris, Joseph J. Zubak

Biomedical Engineering

Premature failure of either the nail and/or locking screws with unstable fracture patterns may lead to angulation, shortening, malunion, and IM nail migration. Up to thirty percent of all unreamed nail locking screws can break after initial weight bearing is allowed at 8–10 weeks if union has not occurred. The primary problem this presents is hardware removal during revision surgery. The purposes of our study was to evaluate the relative fatigue resistance of distal locking screws and bolts from representative manufacturers of tibial IM nail systems, and develop a relative risk assessment of screws and materials used. Evaluations included quantitative …


Deciphering The Biology Of Axon Stretch-Growth, Joseph R. Loverde Jan 2009

Deciphering The Biology Of Axon Stretch-Growth, Joseph R. Loverde

Theses

Traditional nerve regeneration strategies focus on growth cone-mediated growth, a form of nerve growth that occurs primarily during embryogenesis. Early axons continue to grow from the end distal to the soma, seeking targets on which to synapse. It is believed that once the axons synapse, stretch-growth takes over and is responsible for the great lengths achieved by nerves of the central and peripheral nervous systems. Recent work has demonstrated stretch-growth in vitro resulting in dramatically increased growth rates compared to the growth cone. Here, the aim was to decipher the underlying biology associated with axon stretch-growth using two approaches. First, …


Cortical Bone Tissue Engineering;Scaffold Design And Cell Selection, Demin Wen Jan 2009

Cortical Bone Tissue Engineering;Scaffold Design And Cell Selection, Demin Wen

ETD Archive

Cortical bone tissue engineering provides a promising approach to generate graft materials needed to treat the large sized bone defects. The underling premise of tissue engineering is to mimic the in vivo microenvironment as best as possible in vitro culture system. To select an appropriate scaffold material used in this model system, mechanical and hydraulic permeability properties of 316L porous stainless steel and polymethylmethacrylate (PMMA) were studied, as well as their biocompatibility in short and long term cell culture. Results showed that scaffolds made of both stainless steel and PMMA: (1) could be manufactured to have similar permeability as that …


Slurry Based Coatings On Silicon Based Ceramics, Muralidhar Challarapu Jan 2009

Slurry Based Coatings On Silicon Based Ceramics, Muralidhar Challarapu

ETD Archive

Silicon carbide/silicon carbide (SiC/SiC) composites are the leading candidates for advanced high temperature structural components in gas turbine engine application. When SiC surface reacts with O2, protective SiO2 scales are formed, which are the basis for the corrosion resistance of SiC. Their main draw back in terms of usage in a gas-turbine engine is the volatilization of the protective silica scale because of the water vapor which is a byproduct of fuel combustion. The purpose of this project was to develop environmental barrier coatings (EBCs) based on ceramic powders to provide resistance to such moisture damage. In this thesis slurry-coating …


Biomedical Technology: Supporting Movement, Petros Katsioloudis Jan 2009

Biomedical Technology: Supporting Movement, Petros Katsioloudis

STEMPS Faculty Publications

According to the National Institute on Disability and Rehabilitation Research, an estimated 8.5 million children 21 years and younger have a disability (Jans & Stoddard, 1999). After about a decade, with the development of new and sophisticated materials (aluminum alloys, titanium alloys, and carbon fibers) and the integration of electronics, it was then possible to significantly improve the performance of prostheses, built with the so-called endo skeletal (or skeletal-modular) method (Mora, Beratni & Pedrotti, 2006).


Infrared Light Activated Floating Micro Stimulators For Neuro-Prosthetic Applications, Kimberlyn M. Gray Jan 2009

Infrared Light Activated Floating Micro Stimulators For Neuro-Prosthetic Applications, Kimberlyn M. Gray

Doctoral Dissertations

The most common failures in neural stimulation implants are due to interconnect complications such as tissue response, lead migration, and lead breakages. The challenge in eliminating interconnects lies in minimizing device size to maintain spatial selectivity required in the CNS. One approach to this problem is a current generating device that can be stimulated by an external signal, such as light or sound. Here, we report the design, construction and testing of rnicrophotodiode devices that can be stimulated remotely with near-infrared (NIR) light to generate current that can be injected locally into the peripheral nervous system. The use of near-infrared …


Characterization Of Vascular Smooth Muscle Cell Mechanical And Frictional Properties Using Atomic Force Microscopy, Jason Hemmer Dec 2008

Characterization Of Vascular Smooth Muscle Cell Mechanical And Frictional Properties Using Atomic Force Microscopy, Jason Hemmer

All Dissertations

A working hypothesis within the Laboratory of Vascular Research is that mechanical loading on vascular smooth muscle cells (VSMCs), especially due to solid contact from endovascular devices, contributes to the development of restenosis. In order to better understand the role of mechanical loading on VSMCs in vascular disease development, it is imperative to understand the mechanical properties of VSMCs themselves. To measure the viscoelastic and frictional properties of living VSMCs in an in vitro setting, an atomic force microscope (AFM) was utilized, thereby allowing for mechanical testing of living cells in a fluid environment. In the first phase of research, …


Design And Optimization Of A Blood Vessel Mimic Bioreactor System For The Evaluation Of Intravascular Devices In Simple And Complex Vessel Geometries, Sara M. Leifer Nov 2008

Design And Optimization Of A Blood Vessel Mimic Bioreactor System For The Evaluation Of Intravascular Devices In Simple And Complex Vessel Geometries, Sara M. Leifer

Master's Theses

Coronary artery disease affects millions of people and the ability to detect and treat the disease is advancing at a rapid rate. As a result, the development of intravascular technologies is the focus of many medical device manufacturers. Specifically, coronary stent implantation is being performed in an increasing number of patients and a number of new stent designs have been introduced to the market, resulting in the need for improved preclinical testing methods. An in vitro tissue engineered “blood vessel mimic” (BVM) system has previously been established and its feasibility for the initial testing of newly emerging intravascular technology has …


Implantable Biosensors For Real-Time Strain And Pressure Monitoring, Ee Lim Tan, Brandon D. Pereles, Brock Horton, Ranyuan Shao, Mohammed Zourob, Keat Ghee Ong Oct 2008

Implantable Biosensors For Real-Time Strain And Pressure Monitoring, Ee Lim Tan, Brandon D. Pereles, Brock Horton, Ranyuan Shao, Mohammed Zourob, Keat Ghee Ong

Michigan Tech Publications, Part 1

Implantable biosensors were developed for real-time monitoring of pressure and strain in the human body. The sensors, which are wireless and passive, consisted of a soft magnetic material and a permanent magnet. When exposed to a low frequency AC magnetic field, the soft magnetic material generated secondary magnetic fields that also included the higher-order harmonic modes. Parameters of interest were determined by measuring the changes in the pattern of these higher-order harmonic fields, which was achieved by changing the intensity of a DC magnetic field generated by a permanent magnet. The DC magnetic field, or the biasing field, was altered …


Fatigue Testing Of Three Peristernal Median Sternotomy Closure Techniques, Cameron Wangsgard, David J. Cohen, Lanny V. Griffin Sep 2008

Fatigue Testing Of Three Peristernal Median Sternotomy Closure Techniques, Cameron Wangsgard, David J. Cohen, Lanny V. Griffin

Biomedical Engineering

Failure of a sternotomy closure because of closure system fatigue is a complication that may result in dehiscence and put the individual at risk for serious complications. The purpose of this study was to assess the fatigue performance of three peristernal median sternotomy closure techniques (figure-of-eight stainless-steel wires, figure-of-eight stainless-steel cables, or Pectofix Dynamic Sternal Fixation [DSF] stainless-steel plates) in order to quantify the potential risk of fatigue failure of these devices when subject to cyclic loads in physiologically relevant loading directions.


A Comparative Study Of Common Crosslinking Agents For Electrospun Collagen Scaffolds, Pallavi Masih May 2008

A Comparative Study Of Common Crosslinking Agents For Electrospun Collagen Scaffolds, Pallavi Masih

Theses

Cartilage injury is one of the leading causes of knee pain in the world. Over two million Americans suffer from cartilage injury every year, resulting in swelling, pain or joint impairment, causing it difficult to maintain an active life style. Synthetic grafts are used extensively to restore tissue functions. The major drawback limiting successful incorporation of synthetic grafts in body is their lower ability to integrate to natural tissue, poor biocompatibility which often results in triggering immunogenic responses, causing graft rejection. Collagen is thus studied and used excessively as a successful implantable material. The reason being that it is natural …


Mechanical Behavior And Failure Analysis Of Prosthetic Retaining Screws After Long‐Term Use In Vivo. Part 4: Failure Analysis Of 10 Fractured Retaining Screws Retrieved From Three Patients, Youssef S. Al Jabbari, Raymond Fournelle, Gerald J. Ziebert, Jeffrey M. Toth, Anthony Iacopino Jan 2008

Mechanical Behavior And Failure Analysis Of Prosthetic Retaining Screws After Long‐Term Use In Vivo. Part 4: Failure Analysis Of 10 Fractured Retaining Screws Retrieved From Three Patients, Youssef S. Al Jabbari, Raymond Fournelle, Gerald J. Ziebert, Jeffrey M. Toth, Anthony Iacopino

Biomedical Engineering Faculty Research and Publications

Purpose: The aim of this study was to perform a failure analysis on fractured prosthetic retaining screws after long‐term use in vivo. Additionally, the study addresses the commonly asked question regarding whether complex repeated functional occlusal forces initiate fatigue‐type cracks in prosthetic retaining screws.

Materials and Methods: Ten fractured prosthetic retaining screws retrieved from three patients treated with fixed detachable hybrid prostheses were subjected to a failure analysis. In patients 1 and 2, the middle three retaining screws of the prostheses were found fractured at retrieval time after they had been in service for 20 and 19 months, respectively. In …


The Development Of An In Vivo Spinal Fusion Monitor Using Microelectromechanical (Mems) Technology To Create Implantable Microsensors, Lisa Anne Ferrara Jan 2008

The Development Of An In Vivo Spinal Fusion Monitor Using Microelectromechanical (Mems) Technology To Create Implantable Microsensors, Lisa Anne Ferrara

ETD Archive

Surgical fusion of the spine is a conventional approach, and often last alternative, to the correction of a degenerative painful spinal segment. The procedure involves the surgical removal of the intervertebral disc at the problematic site, and the placement of a bone graft that is commonly harvested from the patients iliac crest and placed within the discectomized space. The surrounding bone is expected to incorporate and remodel into the bone graft to eventually provide an immobilized site. Spinal instrumentation often accompanies the bone graft to provide further immobility to the targeted site, thus augmenting the fusion process. However, the status …


Biocompatibility Of Osteoblast Cells On Titanium Implants, Dilip Ayyala Somayajula Jan 2008

Biocompatibility Of Osteoblast Cells On Titanium Implants, Dilip Ayyala Somayajula

ETD Archive

Adhesion and proliferation of UMR 106-01 osteoblast cells were studied on various surface modified titanium materials such as polished, sandblasted, anodized and alkaline treated. Anodization of polished surface in Hydrofluoric acid developed nano-tubes, while NaOH treatment produced spongy microporous morphology. Test samples were coated with non-adhesive protein bovine serum albumin and compared with fibronectin coated specimens. The adhesion study lasted for 4 hrs, where osteoblast cells were cultured in serum free medium. Polished titanium, anodized titanium and NaOH titanium have shown similar percentages of cell adherence. The proliferation study lasted for 48 hrs, where cells were initially allowed to adhere …


Slurry Based Coatings On Silicon Based Ceramics, Sameer K. Khaja-Abdul Jan 2008

Slurry Based Coatings On Silicon Based Ceramics, Sameer K. Khaja-Abdul

ETD Archive

The use of advanced structural ceramics, such as Si3N4 (SN282), SiC, and SiC/SiC composites, is a promising technology to accomplish the high performance goals for advanced turbine applications. These materials exhibit excellent corrosion resistance by forming a dense silica scale. However, severe degradation of the silica scale has been observed due to the presence of certain environmental species, like alkali salts and water vapors, limiting the long-term reliability of structural ceramics. Presence of water vapor in the turbine environment leads to the formation of a gaseous silicon hydroxide species (Si(OH)4) via a reaction with silica layer, SiO2(s) + 2H2O(g) = …


Performance Evaluation Of Aluminum Test Cell Designed For Determining The Heat Resistance Of Bacterial Spores In Foods, H.-J. Chung, Sohan Birla, Juming Tang Jan 2008

Performance Evaluation Of Aluminum Test Cell Designed For Determining The Heat Resistance Of Bacterial Spores In Foods, H.-J. Chung, Sohan Birla, Juming Tang

Department of Agricultural and Biological Systems Engineering: Faculty Publications

Thermal inactivation kinetic studies are necessary to determine heat resistances of spores in the development of new thermal processes for low-acid shelf-stable products. Most currently available sample holders used in the kinetic studies take long time to reach the target sample temperature, hence fail to provide isothermal condition. In this research, novel aluminum test cells were developed to facilitate easy loading and unloading solid and liquid food samples in a hermetically sealed 1 ml cavity to evaluate the heat resistance of bacterial spores when heated at temperatures above 100 °C. Design of the test cell was governed by minimum come-up …


Biomechanical Evaluation Of Locked And Non-Locked Constructs Under Axial And Torsion Loading, Vinit A. Patel Jan 2008

Biomechanical Evaluation Of Locked And Non-Locked Constructs Under Axial And Torsion Loading, Vinit A. Patel

Browse all Theses and Dissertations

Locking compression plates are proven to be safe for use in open reduction and internal fixation (ORIF). The ORIF is a procedure performed to treat fractures. It has various combination of holes, the system provides more options for clinicians to use either locking screw or non-locking screws. This thesis investigates and determines the best construct with special locking and non-locking screws under both axial and torsion loading. Twenty femur constructs were assembled with 2 cm osteotomy gap between femur shaft and condyle, bridged with 4.5 mm - 10 holes condyle plates. Femurs were divided in to 4 groups according to …


Construction, Installation, And Performance Of Two Repacked Weighing Lysimeters, José O. Payero, Suat Irmak Jan 2008

Construction, Installation, And Performance Of Two Repacked Weighing Lysimeters, José O. Payero, Suat Irmak

Department of Agricultural and Biological Systems Engineering: Faculty Publications

Weighing lysimeters are the standard method for directly measuring evapotranspiration (ET). This paper discusses the construction, installation, and performance of two (1.52 m × 1.52 m × 2.13-m deep) repacked weighing lysimeters for measuring ET of corn and soybean in West Central Nebraska. The cost of constructing and installing each lysimeter was approximately US $12,500, which could vary depending on the availability and cost of equipment and labor. The resolution of the lysimeters was 0.0001 mV V-1, which was limited by the data processing and storage resolution of the datalogger. This resolution was equivalent to 0.064 and 0.078 …


Microfabrication Of An Optical Chamber For Exposing Living Cells To Pulsed Electric Fields, Saleh Sheikh Oct 2007

Microfabrication Of An Optical Chamber For Exposing Living Cells To Pulsed Electric Fields, Saleh Sheikh

Electrical & Computer Engineering Theses & Dissertations

I have fabricated a chamber which enables the application of Nanosecond Pulsed Electric Fields (nsPEFs) to living cells while monitoring their real time fluorescence with an inverted microscope. The No. I thickness (150µm nominal) coverslip glass substrate used for fabrication allows the use of high numerical aperture oil immersion objectives for imaging intracellular organelles. Electrodes are fabricated by first evaporating a chromium adhesion layer, followed by a nickel seed layer. Subsequently, an ultra-thick positive photoresist is applied and patterned to create a 30µm thick electroplating mold. The electrodes are then electrodeposited into the mold from a nickel sulfamate plating bath. …


Activation Of Systemic Adhesion Molecules And C Reactive Protein In Response To Biomaterial Particle Induced Cytokine Production, Robin Graham Aug 2007

Activation Of Systemic Adhesion Molecules And C Reactive Protein In Response To Biomaterial Particle Induced Cytokine Production, Robin Graham

All Dissertations

Chronic inflammation has been identified as a major contributor to many diseases including, atherosclerosis, osteoporosis, dementia, Alzheimer's disease and type 2 diabetes, to name a few. Many of the same markers of inflammation found in the diseases listed above, including IL-1, IL-6, TNF-α, NF-B and adhesion molecules, have also been found in wear debris induced osteolysis. While the local response to biomaterial wear debris has been characterized quite extensively, very little is known about the systemic effect of biomaterial wear debris on the inflammatory system. The objectives of this study were to evaluate the in vitro and in vivo inflammatory …


In Vitro Feasibility Testing Of Floating Light-Activated Minroelectrical Stimulators, Ammar Riad Abdo May 2007

In Vitro Feasibility Testing Of Floating Light-Activated Minroelectrical Stimulators, Ammar Riad Abdo

Theses

One of the major challenges of neural stimulation is the mechanical stress and resulting trauma induced on the implanted electrodes by the constant movement of the interconnects. A potential way of eliminating interconnects is to use floating micro-stimulators that can be activated through optical means. As a method of energy transfer to the micro-stimulator, we propose to use a laser beam at near infrared (NIR) wavelengths.

There are two main objectives in this project to test the feasibility of the main approach; investigate the charge injection capacity of titanium nitride (TiN) and iridium oxide (IrOx) as potential contact materials, and …


Biological Cell Identification By Integrating Micro-Fluidics, Electrical Impedance Spectroscopy And Stochastic Estimation, Karl R. Schwenn Mar 2007

Biological Cell Identification By Integrating Micro-Fluidics, Electrical Impedance Spectroscopy And Stochastic Estimation, Karl R. Schwenn

Theses and Dissertations

The integration of micro-fluidics, electrical impedance spectroscopy and stochastic estimation will lead to a device with enhanced detection capabilities. The goal of this thesis was to build a micro-fluidic electrical impedance measurement device that can be used in combination with a stochastic estimator to accurately identify living cells. A microdevice capable of making impedance measurements on individual living cells was designed and built using a series of standard microelectronic fabrication techniques. A microchannel was patterned in SU-8 photoresist between two gold microelectrodes on a two inch Pyrex 7740 wafer. The design process, the fabrication techniques for the microchannel, the fluid …