Open Access. Powered by Scholars. Published by Universities.®

Digital Commons Network™

Open Access. Powered by Scholars. Published by Universities.®

Biomedical Engineering and Bioengineering

Institution
Keyword
Publication Year
Publication
Publication Type
File Type

Articles 511 - 529 of 529

Full-Text Articles in Entire DC Network

Microstructural Enhancement Of Dental Composite And Ceramic Materials By Plasma Etching, H. J. Mueller, M. S. Bapna Jan 1993

Microstructural Enhancement Of Dental Composite And Ceramic Materials By Plasma Etching, H. J. Mueller, M. S. Bapna

Cells and Materials

Radio frequency plasma etching of a selected number of dental materials , including glass filled polymeric composites, alumina reinforced ceramic, glass ionomer, and zinc oxide eugenol enhanced microstructural detail for scanning electron microscopy analyses. All four plasmas, argon , oxygen, carbon tetrafluoride (CF4), and CF4 + 4% 0 2 , proved effective, but the latter was the most effective. The etching of all materials , except the ceramic, was accomplished by the selective removal of a polymeric component. For the glass filled composites , this involved removal of the Bis-GMA matrix resin, leaving the filler particles in relief. For a …


Wear And Friction Of Titanium Nitride On Ultra High Molecular Weight Polyethylene Under Oscillating Motion For Evaluation Of Use In Articulating Orthopedic Applications, David Scott Jacobson May 1992

Wear And Friction Of Titanium Nitride On Ultra High Molecular Weight Polyethylene Under Oscillating Motion For Evaluation Of Use In Articulating Orthopedic Applications, David Scott Jacobson

Theses

Materials are a factor in the performance of articulating orthopedic implants. An oscillating tribometer is utilized to investigate mechanisms of wear and friction of TiN (titanium nitride) coated on Ti-6Al-4V (titanium) alloy against UHMWPe (ultra high molecular weight polyethylene). Three thicknesses of TiN coating (1.76 pm, 4.15 µm, and 10.5 µm) are used to evaluate the performance of each in UHMWPe wear reduction and coating integrity. An uncoated Co-Cr (cobalt chromium) coupon is used against UHMWPe pins for control purposes. Oscillations are carried out to 10 million cycles to discover and evaluate short- and long-term wear mechanisms. Mass differentials and …


Microstructural Changes In Retrieved Amalgam Restorations, Grayson W. Marshall Jr., D. D. Mccoy, John H. Kinney, Hugo Letzel, Sally J. Marshall Jan 1992

Microstructural Changes In Retrieved Amalgam Restorations, Grayson W. Marshall Jr., D. D. Mccoy, John H. Kinney, Hugo Letzel, Sally J. Marshall

Cells and Materials

Many blended or dispersed phase high Cu amalgams show excellent clinical performance in long term clinical trials. However, little is known concerning the microstructural changes that occur during clinical use of these systems. This investigation sought to characterize some of the changes that occur in the Ag-Cu particles and their surrounding reaction zones based on a study by backscattered scanning electron microscopy (BSEM), energy dispersive spectroscopy and a new rnicroprobe technique called Colorad which assigns various colors to elements and element combinations and indicates changes in elemental concentration by changes in color value (brightness). Restorations were retrieved from clinical trials …


Reactogenicity Of Biomaterials As Studied By Biochemical, Morphological And Ultrastructural Techniques, Leonid I. Slutskii, Natalya A. Sevastjanova, Ivetta L. Ozolanta, Irina V. Kuzmina, Laimdota E. Dombrovska Jan 1992

Reactogenicity Of Biomaterials As Studied By Biochemical, Morphological And Ultrastructural Techniques, Leonid I. Slutskii, Natalya A. Sevastjanova, Ivetta L. Ozolanta, Irina V. Kuzmina, Laimdota E. Dombrovska

Cells and Materials

Reactogenicity is a characteristic of biocompatible materials that provokes the reparative and proliferative reaction of connective tissues, a compulsory stage of which is inflammation. Thus, reactogenicity studies should include experiments in vivo. A quantitative assessment of reactogenicity can be obtained by subcutaneous implantation of standard olive-shaped specimens covered by the biomaterial under study followed by biochemical, histological and scanning electron microscopical studies of the capsule developing around the implant. Reactogenicity of surgical threads is evaluated by semiquantitative histological analysis of the wound healing process after suture application. Biomaterial reactogenicity can be modified by changing the structure of the surface and …


Review: Biomaterials For Abdominal Wall Reconstruction, Roger K. J. Simmermacher, Robert P. Bleichrodt, Jeff M. Schakenraad Jan 1992

Review: Biomaterials For Abdominal Wall Reconstruction, Roger K. J. Simmermacher, Robert P. Bleichrodt, Jeff M. Schakenraad

Cells and Materials

The reconstruction of large abdominal wall defects still is a major surgical problem. Many different techniques have been developed for this purpose, most of which appeared to be unsatisfactory. The lack of sufficient tissue requires the insertion of prosthetic material. Non-absorbable prostheses used to reconstruct abdominal wall defects showed the best results . Polypropylene mesh (PPM) and expanded polytetrafluoroethylene (ePTFE) soft-tissue patch are the most frequently used materials for this purpose . However, PPM induces extensive visceral adhesions and erosion of the skin, whereas ePTFE is insufficiently anchored to the adjacent tissue and therefore both materials are not ideal. As …


Design And Fabrication Of An Implantable Cortical Semiconductor Integrated Circuit Electrode Array, Pierre K. Lefevre Dec 1990

Design And Fabrication Of An Implantable Cortical Semiconductor Integrated Circuit Electrode Array, Pierre K. Lefevre

Theses and Dissertations

This research furthered the processing steps of the AFIT 16 by 16 implantable cortical semiconductor integrated circuit electrode array, or brain chip. The areas of interest include the brain chip electron ics, metallization, ionic permeation, and implantation. The electronics and metallization are heavily covered. A high speed, single clock divide-by-two circuit was modified with a reset transistor and cascaded to form a ripple counter. This device had stable operation at specific source voltage and clock voltage and frequency. A 7-stage inverter with 10 unmodified divide-by-two circuits cascaded operated between 1.7 and 8 volts, and between 39 Khz and 1 Mhz, …


Investigation Of The Fluid Dynamics Of Bioprosthetic Heart Valves, Carol A. Calta Jan 1990

Investigation Of The Fluid Dynamics Of Bioprosthetic Heart Valves, Carol A. Calta

Theses

There is a strong connection between altered arterial blood flow and vascular disease. The presence of disturbed flow and/or excessive turbulence is an indication of an abnormality within the cardiovascular system. The examination of cardiovascular fluid dynamics provides insights into the working of the cardiovascular system and ways to improve the design of implantable bioprosthetic valve designs. This investigation examines the fluid flow of arterial systems, and ways to apply this knowledge to the valves implanted into patients.

This thesis involves an investigation of the testing of bioprosthetic valves within simulated left heart flow loops. These systems include pulse duplicators …


A Comparison Of The Fracture Toughness, Hardness, Impact Strength, And Thermal Expansion Of Two Dental Porcelains, Nancy Maignon Aug 1989

A Comparison Of The Fracture Toughness, Hardness, Impact Strength, And Thermal Expansion Of Two Dental Porcelains, Nancy Maignon

Theses

Dental Porcelains are known to be very brittle materials. Ongoing research is being undertaken to obtain a porcelain of optimum strength. A recent development in this field is the new porcelain Optec HSP.

In this comparative study, a series of mechanical test were performed on both Optec HSP and Ceramco II.

An indentation technique was used to calculate the hardness and fracture toughness, the Izod method with a 1 ft-lb pendulum was used to obtain the impact strength, and the thermal expansion was calculated with the Dupont thermal analyser.

For each material, a sample size of five and twenty specimens …


The Evaluation Of Polysulfone Composites As Structural Implants In Orthopaedic Surgery, Howard L. Scalzo May 1989

The Evaluation Of Polysulfone Composites As Structural Implants In Orthopaedic Surgery, Howard L. Scalzo

Theses

Two polysulfone composites were evaluated to determine their use as structural implants in orthopaedic surgery. The first composite, carbon fiber reinforced polysulfone (C/PS), was evaluated for environmental degradation in an in vivo and in vitro study. The C/PS composites were implanted subcutaneously in the abdomen of rabbits for the in vivo study and immersed in saline solution at 32° C for the in vitro study. The second composite, hydroxylapatite coated polysulfone (HA/PS), was evaluated for bone ingrowth in an in vivo study, and for attachment strength between the HA and the PS in an in vitro study. Also, two surface …


Enhancing The Adoption Of Soil Conservation Practices With Targeted Educational Programs, David P. Shelton, Elbert C. Dickey, Paul J. Jasa, David A. Biere Jan 1989

Enhancing The Adoption Of Soil Conservation Practices With Targeted Educational Programs, David P. Shelton, Elbert C. Dickey, Paul J. Jasa, David A. Biere

Department of Agricultural and Biological Systems Engineering: Faculty Publications

Two independent, but closely related, grant funded educational programs have been developed and implemented to reduce soil erosion in selected areas of eastern Nebraska, U.S.A. Traditional extension programming methods as well as other more nontraditional approaches have been extensively used. In one program, encompassing 220,000 ha of cropland, annual soil erosion has been reduced by 2.5 Mt and annual fuel savings of 1.5 ML have been achieved through a reduction in the number of tillage operations. During a one-year period in the second project, more than 81,000 m of terraces were constructed, which resulted in an annual soil erosion reduction …


Determining Crop Residue Cover With Electronic Image Analysis, Elbert C. Dickey, David P. Shelton, G.E. Meyer, K.T. Fairbanks Jan 1989

Determining Crop Residue Cover With Electronic Image Analysis, Elbert C. Dickey, David P. Shelton, G.E. Meyer, K.T. Fairbanks

Department of Agricultural and Biological Systems Engineering: Faculty Publications

Crop residue management is one of the best and most efficient soil conservation methods available to farmers. Determinations of the percentage of the soil surface covered with crop residue are often needed for: soil conservation research; erosion control demonstrations; and maintaining compliance with federal, state, or local soil conservation regulations. A number of methods can be used to estimate residue cover, however, many have limitations. To help overcome some of these limitations, a technique, which uses readily-available microcomputer-related hardware and standard video camera equipment has been developed to estimate crop residue cover from photographic slides. This procedure is relatively rapid, …


Optimization Of The Design Of The Harrington Distraction Rod And Hooks, Margaret Ann Pisani May 1987

Optimization Of The Design Of The Harrington Distraction Rod And Hooks, Margaret Ann Pisani

Theses

The Harrington Distraction Rod is presently attached to the spines of patients who suffer from scoliosis and vertebral fractures. The rod's purpose is to apply a distractive force to the scoliotic curve in an attempt to reduce its severity. In fractures this rod is implanted to reduce the fracture and increase the stability of the spinal column. Harrington distraction rods are also inserted in order to give mechanical support to the spinal column.

Presently the Harrington Distraction Rod, manufactured by Zimmer, is one—quarter inch in diameter and made of 316L cold—worked stainless steel. The proximal end of the rod consists …


In Vitro Comparative Hydrodynamic Study Of Heart Valve Bioprostheses Under Accelerated Fatigue Conditions And Under Physiological Conditions, Mario Cincinat Iosif May 1986

In Vitro Comparative Hydrodynamic Study Of Heart Valve Bioprostheses Under Accelerated Fatigue Conditions And Under Physiological Conditions, Mario Cincinat Iosif

Theses

The present study involves the use of an accelerated fatigue testing system*, and a pulse duplicator (heart simulator)*, to evaluate the hydrodynamic characteristics of cardiac bioprostheses.

The hydrodynamic performance of these prosthetic valves is compared when tested using each machine, in order to assess the determining conditions that exist for each case, and try to correlate them.

Pressure drop and pulsatile flow across valves are measured, using a real-time on-line data acquisition system, which includes, in addition to the fatigue tester and the pulse duplicator, a DC amplifier, an analog-to-digital converter and a digital microcomputer. Special acquisition software has been …


Efficacy And Safety Of The Reciprocal Pulse Defibrillator Current Waveform, M J. Niebauer, Charles F. Babbs, L A. Geddes, J D. Bourland Jan 1984

Efficacy And Safety Of The Reciprocal Pulse Defibrillator Current Waveform, M J. Niebauer, Charles F. Babbs, L A. Geddes, J D. Bourland

Weldon School of Biomedical Engineering Faculty Publications

The efficacy and safety of a new defibrillating current waveform, consisting of a low-tilt 5 ms trapezoidal pulse followed closely by a second identical pulse of opposite polarity, was tested m seven isolated, perfused, working canine hearts suspended in an isoresistive, isosmotic shock bath at 37 oC. The efficacy and safety of the reciprocal pulse was compared with a single 5 ms pulse, a single 10 ms pulse, and a dual (unidirectional) 5 ms pulse waveform. The mean threshold average current densities for the 5 ms single pulse, 10 ms single pulse, dual 5 ms pulse, and reciprocal pulse (absolute …


Mound Sewage Waste Treatment Systems, Elbert C. Dickey, Phillip W. Harlan, Cheryl Kisling-Crouch Jun 1981

Mound Sewage Waste Treatment Systems, Elbert C. Dickey, Phillip W. Harlan, Cheryl Kisling-Crouch

Department of Agricultural and Biological Systems Engineering: Faculty Publications

Several areas in Nebraska are not appropriate for onsite home sewage treatment using conventional septic tank absorption field systems. Site factors that limit the use of conventional absorption fields include slowly permeable soils, shallow or gravelly soils and high water tables. The septic tank-mound system, which consists of a septic tank for primary sewage treatment and a constructed mound for final waste treatment was developed to overcome these site limitations (Figure 1).

Although mound systems differ only slightly in principle from conventional sewage systems, they allow the user to select suitable materials to build an absorption field that relies …


Home Sewage Treatment Systems, Elbert C. Dickey, Robert P. Pharris, Phillip W. Harlan, Gary Hosek Jan 1980

Home Sewage Treatment Systems, Elbert C. Dickey, Robert P. Pharris, Phillip W. Harlan, Gary Hosek

Department of Agricultural and Biological Systems Engineering: Faculty Publications

Homeowners in areas not served by municipal sewage treatment systems face a problem of providing safe and effective wastewater treatment systems for their homes.

There are several methods currently available for proper treatment of home sewage, including septic tank absorption fields, mounds, lagoons, aerobic treatment units and others. These systems and their advantages and disadvantages are discussed in this NebGuide.

Treatment and disposal of domestic sewage is of concern because of the variety of pathogenic organisms contained in sewage. These include bacteria, viruses, and other microorganisms that come from the digestive tract, respiratory tract, and skin of man. Some of …


A Septic Tank System For Sewage Treatment, Elbert C. Dickey, Phillip W. Harlan, Gary Hosek Jun 1979

A Septic Tank System For Sewage Treatment, Elbert C. Dickey, Phillip W. Harlan, Gary Hosek

Department of Agricultural and Biological Systems Engineering: Faculty Publications

A properly designed, installed ao1d maintained septic tank system is an approved method of sewage treatment for private residences in rural or urban areas where public sewage treatment systems are not available. The components of a septic system are the house sewer, the septic tank and the absorption field, as illustrated in Figure 1. Sewage flows to the septic tank through the house sewer. In the septic tank, the solids are separated from the liquids, undergo anaerobic digestion and are stored as sludge at the bottom of the tank. The liquid (septic tank effluent) flows to the absorption field …


New Phytotron Widens Scope For Research, Department Of Agriculture, Western Australia Jan 1967

New Phytotron Widens Scope For Research, Department Of Agriculture, Western Australia

Journal of the Department of Agriculture, Western Australia, Series 4

A WIDE range of new experiments and greater speed and efficiency in many existing projects has been made possible by the recent completion of the Department of Agriculture phytotron at South Perth.


Termites Or White Ants, Clee Francis Howard Jenkins Jan 1960

Termites Or White Ants, Clee Francis Howard Jenkins

Journal of the Department of Agriculture, Western Australia, Series 4

TERMITES are commonly but erroneously called "white ants."

Actually they are more nearly related to cockroaches than to ants, but their general appearance and subterranean habits have given strong support to the popular designation.

They may be divided into two major groups from an economic point of view, viz., wood-dwelling and earth-dwelling termites.