Open Access. Powered by Scholars. Published by Universities.®
- Keyword
-
- 3D dosimetry (1)
- Biological effects (1)
- Cone-beam CT (CBCT). (1)
- Electron return effect (1)
- Flattening filter free (FFF) (1)
-
- Gafchromic EBT3 (1)
- Generalized linear modeling (1)
- Hyperpolarized (1)
- IROC (1)
- Intensity modulated radiation therapy (IMRT) (1)
- Intrafraction imaging (1)
- Lung cancer (1)
- MR-guided radiation therapy (1)
- MRgRT (1)
- Magnetic resoance (1)
- Monte Carlo (1)
- PRESAGE (1)
- Phantom (1)
- Proton therapy (1)
- Pyruvate (1)
- RBE (1)
- Recalculation (1)
- Respiratory gating (1)
- Respiratory motion (1)
- Simulation (1)
- Stereotactic ablative body radiotherapy (SABR) (1)
- TPS (1)
- Treatment outcomes (1)
- Volumetric modulated arc therapy (VMAT) (1)
- Publication
- Publication Type
Articles 1 - 7 of 7
Full-Text Articles in Other Physics
Novel Simulation To Avoid Bias In Measurement Of Hyperpolarized Pyruvate: Demonstrated In Phantom And In Vivo, Christopher M. Walker
Novel Simulation To Avoid Bias In Measurement Of Hyperpolarized Pyruvate: Demonstrated In Phantom And In Vivo, Christopher M. Walker
Dissertations & Theses (Open Access)
Dynamic nuclear polarization creates a transient hyperpolarized nuclear state that can dramatically increase the signal detected by magnetic resonance imaging. This signal increase allows real-time spectroscopic imaging of specific metabolites in vivo by magnetic resonance. Real-time imaging of both the spatial and chemical fate of hyperpolarized metabolites is showing great promise to meaningfully benefit clinical care of cancer patients. Imaging of hyperpolarized agents will have a larger clinical impact if it can function as a quantitative modality upon which clinical decisions can be made. However, quantitative measurement of hyperpolarized agents is currently difficult due to the restrictions imposed by the …
Assessing The Potential Clinical Impact Of Variable Biological Effectiveness In Proton Radiotherapy, Christopher R. Peeler Ph.D.
Assessing The Potential Clinical Impact Of Variable Biological Effectiveness In Proton Radiotherapy, Christopher R. Peeler Ph.D.
Dissertations & Theses (Open Access)
It has long been known that proton radiotherapy has an increased biological effectiveness compared to traditional x-ray radiotherapy. This arises from the clustered nature of DNA damage produced by the energy deposition of protons along their tracks in medium. This effect is currently quantified in clinical settings by assigning protons a relative biological effectiveness (RBE) value of 1.1 corresponding to 10% increased effectiveness compared to photon radiation. Numerous studies have shown, however, that the RBE value of protons is variable and can deviate substantially from 1.1, but experimental data on RBE and clinical evidence of its variability remains limited.
The …
Developing Hyperpolarized Silicon Particles For In Vivo Mri Targeting Of Ovarian Cancer, Nicholas Whiting, Jingzhe Hu, Niki M. Zacharias, Ganesh L. R. Lokesh, David E. Volk, David G. Menter, Rajesha Rupaimoole, Rebecca Previs, Anil K. Sood, Pratip Bhattacharya
Developing Hyperpolarized Silicon Particles For In Vivo Mri Targeting Of Ovarian Cancer, Nicholas Whiting, Jingzhe Hu, Niki M. Zacharias, Ganesh L. R. Lokesh, David E. Volk, David G. Menter, Rajesha Rupaimoole, Rebecca Previs, Anil K. Sood, Pratip Bhattacharya
Nicholas Whiting
Identifying Treatment Planning System Errors In Iroc-Houston Head And Neck Phantom Irradiations, James Kerns
Identifying Treatment Planning System Errors In Iroc-Houston Head And Neck Phantom Irradiations, James Kerns
Dissertations & Theses (Open Access)
Treatment Planning System (TPS) errors can affect large numbers of cancer patients receiving radiation therapy. Using an independent recalculation system, the Imaging and Radiation Oncology Core-Houston (IROC-H) can identify institutions that have not sufficiently modelled their linear accelerators in their TPS model. Linear accelerator point measurement data from IROC-H’s site visits was aggregated and analyzed from over 30 linear accelerator models. Dosimetrically similar models were combined to create “classes”. The class data was used to construct customized beam models in an independent treatment dose verification system (TVS). Approximately 200 head and neck phantom plans from 2012 to 2015 were recalculated …
Measurement Of The Electron Return Effect Using Presage Dosimeter, Gye Won Choi
Measurement Of The Electron Return Effect Using Presage Dosimeter, Gye Won Choi
Dissertations & Theses (Open Access)
MR-guided radiation therapy (MRgRT) provides benefits such as superior soft tissue contrast, no imaging dose, and functional imaging capacities, but it also has concerns to be addressed. The electron return effect (ERE) refers to dose enhancement at the interface between different media, caused when radiation is delivered in the magnetic field. The ERE poses clinical concerns in MRgRT because it significantly enhances the dose at interfaces, and the intensity and pattern of the dose enhancement depends on many factors. The ERE results in a complex pattern of dose enhancement over a three-dimensional (3D) volume around tissue interfaces inside the patient …
Optimizing Respiratory Gated Intensity Modulated Radiation Therapy Planning And Delivery Of Early-Stage Non-Small Cell Lung Cancer, Ilma Xhaferllari
Optimizing Respiratory Gated Intensity Modulated Radiation Therapy Planning And Delivery Of Early-Stage Non-Small Cell Lung Cancer, Ilma Xhaferllari
Electronic Thesis and Dissertation Repository
Stereotactic ablative body radiotherapy (SABR) is the standard of care for inoperable early-stage non-small cell lung cancer (NSCLC) patients. However, thoracic tumours are susceptible to respiratory motion and, if unaccounted for, can potentially lead to dosimetric uncertainties. Respiratory gating is one method that limits treatment delivery to portions of the respiratory cycle, but when combined with intensity-modulated radiotherapy (IMRT), requires rigorous verification. The goal of this thesis is to optimize respiratory gated IMRT treatment planning and develop image-guided strategies to verify the dose delivery for future early-stage NSCLC patients.
Retrospective treatment plans were generated for various IMRT delivery techniques, including …
Interrogating Metabolism In Brain Cancer, Travis Salzillo, Jingzhe Hu, Linda Nguyen, Nicholas Whiting, Jaehyuk Lee, Joseph Weygand, Prasanta Dutta, Shivanand Pudakalakatti, Niki Zacharias Millward, Seth Gammon, Frederick F. Lang, Amy B. Heimberger, Pratip Bhattacharya
Interrogating Metabolism In Brain Cancer, Travis Salzillo, Jingzhe Hu, Linda Nguyen, Nicholas Whiting, Jaehyuk Lee, Joseph Weygand, Prasanta Dutta, Shivanand Pudakalakatti, Niki Zacharias Millward, Seth Gammon, Frederick F. Lang, Amy B. Heimberger, Pratip Bhattacharya
Nicholas Whiting