Articles 1 - 5 of 5
Full-Text Articles in Engineering Physics
Statistical Characteristics Of High-Frequency Gravity Waves Observed By An Airglow Imager At Andes Lidar Observatory, Alan Z. Liu, Bing Cao
Statistical Characteristics Of High-Frequency Gravity Waves Observed By An Airglow Imager At Andes Lidar Observatory, Alan Z. Liu, Bing Cao
Publications
The long-term statistical characteristics of high-frequency quasi-monochromatic gravity waves are presented using multi-year airglow images observed at Andes Lidar Observatory (ALO, 30.3° S, 70.7° W) in northern Chile. The distribution of primary gravity wave parameters including horizontal wavelength, vertical wavelength, intrinsic wave speed, and intrinsic wave period are obtained and are in the ranges of 20–30 km, 15–25 km, 50–100 m s−1, and 5–10 min, respectively. The duration of persistent gravity wave events captured by the imager approximately follows an exponential distribution with an average duration of 7–9 min. The waves tend to propagate against the local background winds and …
Finite-Time State Estimation For An Inverted Pendulum Under Input-Multiplicative Uncertainty, Sergey V. Drakunov, William Mackunis, Anu Kossery Jayaprakash, Krishna Bhavithavya Kidambi, Mahmut Reyhanoglu
Finite-Time State Estimation For An Inverted Pendulum Under Input-Multiplicative Uncertainty, Sergey V. Drakunov, William Mackunis, Anu Kossery Jayaprakash, Krishna Bhavithavya Kidambi, Mahmut Reyhanoglu
Publications
A sliding mode observer is presented, which is rigorously proven to achieve finite-time state estimation of a dual-parallel underactuated (i.e., single-input multi-output) cart inverted pendulum system in the presence of parametric uncertainty. A salient feature of the proposed sliding mode observer design is that a rigorous analysis is provided, which proves finite-time estimation of the complete system state in the presence of input-multiplicative parametric uncertainty. The performance of the proposed observer design is demonstrated through numerical case studies using both sliding mode control (SMC)- and linear quadratic regulator (LQR)-based closed-loop control systems. The main contribution presented here is the rigorous …
Error Analysis Of Multi-Needle Langmuir Probe Measurement Technique, Aroh Barjatya, William Merritt
Error Analysis Of Multi-Needle Langmuir Probe Measurement Technique, Aroh Barjatya, William Merritt
Publications
Multi-needle Langmuir probe is a fairly new instrument technique that has been flown on several recent sounding rockets and is slated to fly on a subset of QB50 CubeSat constellation. This paper takes a fundamental look into the data analysis procedures used for this instrument to derive absolute electron density. Our calculations suggest that while the technique remains promising, the current data analysis procedures could easily result in errors of 50% or more. We present a simple data analysis adjustment that can reduce errors by at least a factor of five in typical operation.
Contamination Effects On Fixed-Bias Langmuir Probes, C.T. Steigies, Aroh Barjatya
Contamination Effects On Fixed-Bias Langmuir Probes, C.T. Steigies, Aroh Barjatya
Publications
Langmuir probes are standard instruments for plasma density measurements on many sounding rockets. These probes can be operated in swept-bias as well as in fixed-bias modes. In swept-bias Langmuir probes, contamination effects are frequently visible as a hysteresis between consecutive up and down voltage ramps. This hysteresis, if not corrected, leads to poorly determined plasma densities and temperatures. With a properly chosen sweep function, the contamination parameters can be determinedfromthemeasurementsandcorrectplasmaparameterscanthenbedetermined.Inthispaper, we study the contamination effects on fixed-bias Langmuir probes, where no hysteresis type effect is seen in the data. Even though the contamination is not evident from the measurements, it …
A Comprehensive Rocket And Radar Study Of Midlatitude Spread F, G.D. Earle, P. Bhanja, P.A. Roddy, C.M. Swenson, Aroh Barjatya, Et Al.
A Comprehensive Rocket And Radar Study Of Midlatitude Spread F, G.D. Earle, P. Bhanja, P.A. Roddy, C.M. Swenson, Aroh Barjatya, Et Al.
Publications
An instrumented sounding rocket launched from Wallops Island Virginia has flown through a midlatitude spread F (MSF) event in conjunction with simultaneous ionosonde, HF radar, and 244 MHz scintillation observations from the ground. The in situ measurements include the electric field, horizontal neutral wind, and plasma density within the spread F region. The ground‐based HF radar measurements of wave signatures in the bottomside F region ledge reveal the presence of waves propagating to the north and northwest prior to and during the spreading event. The periods of these bottomside waves range from 16 to 60 min, and they are shown …