Open Access. Powered by Scholars. Published by Universities.®

Physics Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles

Discipline
Institution
Keyword
Publication Year
File Type

Articles 61 - 90 of 388

Full-Text Articles in Physics

Swirling Fluid Flow In Flexible, Expandable Elastic Tubes: Variational Approach, Reductions And Integrability, Rossen Ivanov, Vakhtang Putkaradze Jan 2020

Swirling Fluid Flow In Flexible, Expandable Elastic Tubes: Variational Approach, Reductions And Integrability, Rossen Ivanov, Vakhtang Putkaradze

Articles

Many engineering and physiological applications deal with situations when a fluid is moving in flexible tubes with elastic walls. In real-life applications like blood flow, a swirl in the fluid often plays an important role, presenting an additional complexity not described by previous theoretical models. We present a theory for the dynamics of the interaction between elastic tubes and swirling fluid flow. The equations are derived using a variational principle, with the incompressibility constraint of the fluid giving rise to a pressure-like term. In order to connect this work with the previous literature, we consider the case of inextensible and …


On The Intermediate Long Wave Propagation For Internal Waves In The Presence Of Currents, Joseph Cullen, Rossen Ivanov Jan 2020

On The Intermediate Long Wave Propagation For Internal Waves In The Presence Of Currents, Joseph Cullen, Rossen Ivanov

Articles

A model for the wave motion of an internal wave in the presence of current in the case of intermediate long wave approximation is studied. The lower layer is considerably deeper, with a higher density than the upper layer. The flat surface approximation is assumed. The fluids are incompressible and inviscid. The model equations are obtained from the Hamiltonian formulation of the dynamics in the presence of a depth-varying current. It is shown that an appropriate scaling leads to the integrable Intermediate Long Wave Equation (ILWE). Two limits of the ILWE leading to the integrable Benjamin-Ono and KdV equations are …


In-Situ Ellipsometric Study Of The Optical Properties Of Ltl-Doped Thin Film Sensors For Copper(Ii) Ion Detection, Dervil Cody, Tsvetanka Babeva, Violeta Madjarova, Anastasia Kharchenko, Sabad-E- Gul, Svetlana Mintova, Christopher J. Barrett, Izabela Naydenova Jan 2020

In-Situ Ellipsometric Study Of The Optical Properties Of Ltl-Doped Thin Film Sensors For Copper(Ii) Ion Detection, Dervil Cody, Tsvetanka Babeva, Violeta Madjarova, Anastasia Kharchenko, Sabad-E- Gul, Svetlana Mintova, Christopher J. Barrett, Izabela Naydenova

Articles

Optical sensors fabricated in zeolite nanoparticle composite films rely on changes in their optical properties (refractive index, n, and thickness, d) to produce a measurable response in the presence of a target analyte. Here, ellipsometry is used to characterize the changes in optical properties of Linde Type L (LTL) zeolite thin films in the presence of Cu2+ ions in solution, with a
view to improving the design of optical sensors that involve the change of n and/or d due to the adsorption of Cu2+ ions. The suitability of two different ellipsometry techniques (single wavelength and spectroscopic) for the evaluation of …


Polyvinyl Alcohol Cryogel Based Vessel Mimicking Material For Modelling The Progression Of Atherosclerosis, Andrew Malone, Sean Cournane, Izabela Naydenova, Andrew J. Fagan, Jacinta Browne Jan 2020

Polyvinyl Alcohol Cryogel Based Vessel Mimicking Material For Modelling The Progression Of Atherosclerosis, Andrew Malone, Sean Cournane, Izabela Naydenova, Andrew J. Fagan, Jacinta Browne

Articles

Purpose

The stiffness of Polyvinyl-alcohol cryogel can be adjusted through application of consecutive freeze-thaw cycles. This material has potential applications in the production of tissue mimicking phantoms in diagnostic ultrasound. The aim of this study was to use PVA-c to produce a range of geometrically and acoustically identical vessel phantoms modelling stages of atherosclerosis which could be verified through mechanical testing, thus allowing for more precision in quantitative in-vitro flow analysis of atherosclerosis.

Methods

A series of anatomically realistic walled renal artery flow phantoms were constructed using PVA-c. In order to ensure precise modelling of atherosclerosis, a modified procedure of …


An Investigation Of The Detection Capability Of Pulsed Wave Duplex Doppler Of Low Grade Stenosis Using Ultrasound Contrast Agent Microbubbles – An In-Vitro Study, Jacinta Browne, Deirdre King, Andrew Fagan, Deepa Chari, Carmel Moran Apr 2019

An Investigation Of The Detection Capability Of Pulsed Wave Duplex Doppler Of Low Grade Stenosis Using Ultrasound Contrast Agent Microbubbles – An In-Vitro Study, Jacinta Browne, Deirdre King, Andrew Fagan, Deepa Chari, Carmel Moran

Articles

Objective: The objective of the study was to investigate whether clinically used ultrasonic contrast agents improved the accuracy of spectral Doppler ultrasound in the detection of low grade (< 50%) renal artery stenosis. Low grade stenoses in the renal artery are notoriously difficult to reliably detect using Doppler ultrasound due to difficulties such as overlying fat and bowel gas.

Methods: A range of anatomically-realistic renal artery phantoms with varying low degrees of stenosis (0, 30 and 50%) were constructed and peak velocity data was measured from within the pre-stenotic and mid-stenotic regions in each phantom, for both unenhanced and contrast-enhanced spectral Doppler data acquisitions. The effect of a 20mm overlying fat layer on the ultrasound beam distortion and phase aberration, and hence on the measured peak velocity data, was also …


Use Of Novel Anthropomorphic Breast Ultrasound Phantoms For Radiology Resident Education, Jacinta Browne, Chris Gu, Robert Fazzio, Andrew Fagan, Donald Tradup, Nicholas Hangiandreou Feb 2019

Use Of Novel Anthropomorphic Breast Ultrasound Phantoms For Radiology Resident Education, Jacinta Browne, Chris Gu, Robert Fazzio, Andrew Fagan, Donald Tradup, Nicholas Hangiandreou

Articles

Purpose: This study evaluated the training and assessment role of anthropomorphic breast ultrasound phantoms which simulated both the morphological and sonographic characteristics of breast tissue, including lesions, in a group of radiology residents at a large academic medical center. Methods: This was a prospective study involving 9 residents across all years (2nd–4th year) of a radiology residency program. Baseline assessments of all residents ability to detect and characterize lesions in P-I were carried out, followed by a two-hour teaching session on the same phantom. All residents underwent a post-training, final assessment on P-II to evaluate changes in …


Third-Order Optical Nonlinearity Properties Of Cdcl2-Modifed Ge–Sb–S Chalcogenide Glasses, Xiaosong Lu, Jianhui Li, Lu Yang, Runan Zhang, Yindong Zhang, Jing Ren, Aurelian Catalin Galca, Mihail Secu, Gerald Farrell, Pengfei Wang Jan 2019

Third-Order Optical Nonlinearity Properties Of Cdcl2-Modifed Ge–Sb–S Chalcogenide Glasses, Xiaosong Lu, Jianhui Li, Lu Yang, Runan Zhang, Yindong Zhang, Jing Ren, Aurelian Catalin Galca, Mihail Secu, Gerald Farrell, Pengfei Wang

Articles

We developed a new type of chalcohalide glasses with physicochemical and nonlinear optical properties that are tunable by composition. It is found that more than 60 mol.% CdCl2 heavy metal halide can be dissolved into the ternary Ge–Sb–S system and forming stable glasses. The visible-light transparency range is extended to shorter wavelengths with the addition of CdCl2, which is beneficial for the optical quality control and infra-red (IR) system alignment. The third-order optical nonlinearity (TONL) is studied using the femtosecond Z-scan method. The results show that both the nonlinear refractive index and two photon absorption co-efficient decrease with CdCl2. Benefiting …


A Twelve-Wavelength Thulium-Doped Fibre Laser Based On A Microfibre Coil Resonator Incorporating Black Phosphorus, Shi Li, Yu Yin, Elfed Lewis, Gerald Farrell, Pengfei Wang Jan 2019

A Twelve-Wavelength Thulium-Doped Fibre Laser Based On A Microfibre Coil Resonator Incorporating Black Phosphorus, Shi Li, Yu Yin, Elfed Lewis, Gerald Farrell, Pengfei Wang

Articles

A novel multi-wavelength continuous Thulium-doped fibre laser incorporating a microfibre coil resonator based on black phosphorus (MCR-BP) material has been successfully fabricated and demonstrated. A twelve-wavelength spectrum with 0.54 nm channel spacing has been achieved by simply adjusting the pump source power. A single peak extinction ratio of more than 40 dB was observed. The superior performance of the MCR-BP described in this article compared to conventional MCR based fibre lasers can be attributed the inclusion of the Black Phosphorous Material. The enhanced lasing is primarily due to the twin properties of the MCR-BP device combining a comb-like filter effect …


All Fibre Q-Switched Thulium-Doped Fibre Laser Incorporating Thulium–Holmium Co-Doped Fibre As A Saturable Absorber, Shi Li, Elfed Lewis, Gerald Farrell, Ahmad Haziq Aiman Rosol, A.A. Latiff, Sulaiman Wadi Harun, Bingang Guo, Pengfei Wang Jan 2019

All Fibre Q-Switched Thulium-Doped Fibre Laser Incorporating Thulium–Holmium Co-Doped Fibre As A Saturable Absorber, Shi Li, Elfed Lewis, Gerald Farrell, Ahmad Haziq Aiman Rosol, A.A. Latiff, Sulaiman Wadi Harun, Bingang Guo, Pengfei Wang

Articles

A novel all fibre Q-switched Thulium-doped fibre laser (TDFL) is reported which includes a short length of a Thulium–Holmiumco-doped fibre (THDF) as a saturable absorber. A high repetition rate (27.26 kHz) coupled with a low pulse width (19.06μs) is obtained for single wavelength Q-switched pulse operation at an output wavelength of 1911.5 nm using a pump power of 200 mW. Increasing the pump power from 200 mW to 700 mW results in the repetition rate increasing from 27.26 kHz to 99.67 kHz and the pulse width decreasing from 19.06μs to 920 ns. The centre wavelength of the single Q-switched pulse …


Distribution Of Tm 3+ And Ni 2+ In Chalcogenide Glass Ceramics Containing Ga2s3 Nanocrystals: Influence On Photoluminescence Properties, Xiaosong Lu, Zhiqiang Lai, Jing Ren, Lukas Strizik, Tomas Wagner, Yanqiu Du, Gerald Farrell, Pengfei Wang Jan 2019

Distribution Of Tm 3+ And Ni 2+ In Chalcogenide Glass Ceramics Containing Ga2s3 Nanocrystals: Influence On Photoluminescence Properties, Xiaosong Lu, Zhiqiang Lai, Jing Ren, Lukas Strizik, Tomas Wagner, Yanqiu Du, Gerald Farrell, Pengfei Wang

Articles

The distribution of Tm3+ and Ni2+ ions is unambiguously exhibited in 80GeS2-20Ga2S3 chalcogenide glass ceramics (GCs) containing Ga2S3 nanocrystals (NCs) by using advanced analytical transmission electron microscopy. Distinctively different distribution patterns of Tm3+ and Ni2+ ions are observed in the GCs obtained by controlled crystallization. The distribution of the dopants imposes strong influence on their optical properties which are revealed by absorption and photoluminescence (PL) spectra. Detailed discussions are given of the mechanisms of the crystallization-induced PL enhancement and quenching of the Tm3+ mid-infrared and Ni2+ near-infrared emissions, respectively.


In-Fiber Temperature Sensor Based On Green Up-Conversion Luminescence In An Er3+-Yb3+ Co-Doped Tellurite Glass Microsphere, Meng Zhang, Angzhen Li, Jibo Yu, Xiaosong Lu, Shunbin Wang, Elfed Lewis, Gerald Farrell, Libo Yuan, Pengfei Wang Jan 2019

In-Fiber Temperature Sensor Based On Green Up-Conversion Luminescence In An Er3+-Yb3+ Co-Doped Tellurite Glass Microsphere, Meng Zhang, Angzhen Li, Jibo Yu, Xiaosong Lu, Shunbin Wang, Elfed Lewis, Gerald Farrell, Libo Yuan, Pengfei Wang

Articles

A novel, to the best of our knowledge, in-fiber temperature sensor based on green up-conversion (UC) luminescence in an Er3+-Yb3+" role="presentation" style="box-sizing: border-box; display: inline; font-size: 12.88px; line-height: normal; word-spacing: normal; overflow-wrap: normal; white-space: nowrap; float: none; direction: ltr; max-width: none; max-height: none; min-width: 0px; min-height: 0px; border: 0px; padding: 0px; margin: 0px; position: relative;">Er3+-Yb3+Er3+-Yb3+ co-doped tellurite glass microsphere is described. The tellurite glass microsphere is located firmly inside a suspended tri-core hollow-fiber (STCHF) structure. The pump light launched via a single-mode fiber (SMF) is passed through a section of multimode fiber, which is fusion spliced between the SMF …


Ultrabroadband Mid-Infrared Emission From Cr 2+ -Doped Infrared Transparent Chalcogenide Glass Ceramics Embedded With Thermally Grown Zns Nanorods, Xiaosong Lu, Zhiqiang Lai, Runan Zhang, Haitao Guo, Jing Ren, Lukas Strizik, Tomas Wagner, Gerald Farrell, Pengfei Wang Jan 2019

Ultrabroadband Mid-Infrared Emission From Cr 2+ -Doped Infrared Transparent Chalcogenide Glass Ceramics Embedded With Thermally Grown Zns Nanorods, Xiaosong Lu, Zhiqiang Lai, Runan Zhang, Haitao Guo, Jing Ren, Lukas Strizik, Tomas Wagner, Gerald Farrell, Pengfei Wang

Articles

We report, for the first time to our knowledge, an ultrabroadband mid-infrared (MIR) emission in the range of 1800–2800 nm at room temperature from a Cr2+-doped chalcogenide glass ceramic embedded with pure hexagonal (wurtzite) β-ZnS nanorods and study the emission-dependent properties on the doping concentration of Cr2+. A new family of chalcogenide glasses based on (100 − x) Ge1.5As2S6.5 – x ZnSe (in mol.%) was prepared by melt-quenching method. The Cr2+: β-ZnS nanorods of ˜150 nm in diameter and ˜1 μm in length were grown in the Cr2+-doped glass after thermal annealing. The compositional variations of glass structures and optical …


Sns Optical Fiber Structure Sensor For Direct Detection Of The Phase Transition In C18h38 N-Alkane Material, Wei Han, Marek Rebow, Xiaokang Lian, Dejun Liu, Gerald Farrell, Qiang Wu, Yuliya Semenova Jan 2019

Sns Optical Fiber Structure Sensor For Direct Detection Of The Phase Transition In C18h38 N-Alkane Material, Wei Han, Marek Rebow, Xiaokang Lian, Dejun Liu, Gerald Farrell, Qiang Wu, Yuliya Semenova

Articles

A singlemode-no-core-singlemode (SNS) fiber structure optical sensor for detecting the solid-liquid phase change in a phase change material: C18H38 n-alkane material (n-octadecane) is proposed and demonstrated. The transmission-type sensor probe consists of a short section of no-core fiber sandwiched between two sections of a singlemode fiber. Phase changes in n-octadecane are accompanied by large step-like variations of its refractive index (RI). Such a large discontinuous change of the n-octadecane’s RI during its phase transition, leads to the corresponding step-like change in the transmitted optical power that can reliably indicate the phase change of the sample in the vicinity of the …


Investigation Of The Assessment Of Low Degree (<50%) Renal Artery Stenosis Based On Velocity Flow Profile Analysis Using Doppler Ultrasound: An In-Vitro Study, Andrew Malone, Deepa Chari, Sean Cournane, Izabela Naydenova, Andrew Fagan, Jacinta Browne Jan 2019

Investigation Of The Assessment Of Low Degree (<50%) Renal Artery Stenosis Based On Velocity Flow Profile Analysis Using Doppler Ultrasound: An In-Vitro Study, Andrew Malone, Deepa Chari, Sean Cournane, Izabela Naydenova, Andrew Fagan, Jacinta Browne

Articles

Purpose: Renal arterial stenosis can lead to disrupted renal function due to reduced blood flow to the kidneys and is largely thought to be caused by atherosclerosis. Current diagnostic strategies for renal arterial stenosis rely on detecting large degree stenoses (>50%). This study aimed to test the viability of using Doppler ultrasound to assess velocity profiles to detect the presence of low degree (<50%) stenoses.

Methods: A series of anatomically realistic renal artery flow phantoms were constructed exhibiting a range of low degree stenoses (symmetric and asymmetric). The behaviour of fluid flow in the phantoms was examined using Doppler ultrasound …


Impact Of Plasma Treatment On Acoustic Properties Of Natural Cellulose Materials, Sanja S. Pavlović, Snežana B. Stanković, Andrijana Žekić, Miloš Nenadović, Dušan M. Popović, Vladimir Milosavljevic, Goran B. Poparić Jan 2019

Impact Of Plasma Treatment On Acoustic Properties Of Natural Cellulose Materials, Sanja S. Pavlović, Snežana B. Stanković, Andrijana Žekić, Miloš Nenadović, Dušan M. Popović, Vladimir Milosavljevic, Goran B. Poparić

Articles

Low-temperature plasma is widely used in many surface treatment technologies for modifications of the physical properties of different polymeric materials. In the present work, we have examined the modification of acoustical properties of natural cellulose materials (cotton, hemp) by the radio-frequency argon plasma. We have observed an increase of the sound absorption coefficient due to the plasma treatment for certain range of applied powers. An analysis of elementary processes which happened during plasma–material interaction was conducted. Additional analyses related to material characterizations were performed in order to resolve structural and chemical changes of plasma treated materials. The micro-mechanical modification of …


Relationship Of Ndvi And Oak (Quercus)Pollen Including A Predictive Model In The Sw Mediterranean Region, Rocío González-Naharro, Elia Quirós, Santiago Fernández-Rodríguez, Inmaculada Silva-Palacios, J. M. Maya-Manzano, Rafael Tormo-Molina, Raúl Pecero-Casimiro, Alejandro Monroy-Colin, Ángela Gonzalo-Garijo Jan 2019

Relationship Of Ndvi And Oak (Quercus)Pollen Including A Predictive Model In The Sw Mediterranean Region, Rocío González-Naharro, Elia Quirós, Santiago Fernández-Rodríguez, Inmaculada Silva-Palacios, J. M. Maya-Manzano, Rafael Tormo-Molina, Raúl Pecero-Casimiro, Alejandro Monroy-Colin, Ángela Gonzalo-Garijo

Articles

Techniques of remote sensing are being used to develop phenological studies. Our goal is to study the correlation among the Normalized Difference Vegetation Index (NDVI) related with oak trees included in three set data polygons (15, 25 and 50 km to aerobiological sampling point as NDVI-15, 25 and 50), and oak (Quercus) daily average pollen counts from 1994 to 2013. The study was developed in the SW Mediterranean region with continuous pollen recording within the mean pollen season of each studied year. These pollen concentrations were compared with NDVI values in the locations containing the vegetation under a study based …


Surface Waves Over Currents And Uneven Bottom, Alan Compelli, Rossen Ivanov, Calin I. Martin, Michail D. Todorov Jan 2019

Surface Waves Over Currents And Uneven Bottom, Alan Compelli, Rossen Ivanov, Calin I. Martin, Michail D. Todorov

Articles

The propagation of surface water waves interacting with a current and an uneven bottom is studied. Such a situation is typical for ocean waves where the winds generate currents in the top layer of the ocean. The role of the bottom topography is taken into account since it also influences the local wave and current patterns. Specific scaling of the variables is selected which leads to approximations of Boussinesq and KdV types. The arising KdV equation with variable coefficients, dependent on the bottom topography, is studied numerically when the initial condition is in the form of the one soliton solution …


Equatorial Wave–Current Interactions, Adrian Constantin, Rossen Ivanov Jan 2019

Equatorial Wave–Current Interactions, Adrian Constantin, Rossen Ivanov

Articles

We study the nonlinear equations of motion for equatorial wave–current interactions in the physically realistic setting of azimuthal two-dimensional inviscid flows with piecewise constant vorticity in a two-layer fluid with a flat bed and a free surface. We derive a Hamiltonian formulation for the nonlinear governing equations that is adequate for structure-preserving perturbations, at the linear and at the nonlinear level. Linear theory reveals some important features of the dynamics, highlighting differences between the short- and long-wave regimes. The fact that ocean energy is concentrated in the long-wave propagation modes motivates the pursuit of in-depth nonlinear analysis in the long-wave …


Concentric Double Hollow Grid Cathode Discharges, C. T. Teodorescu-Soare, S. A. Irimiciuc, C. Ionita, D. G. Dimitriu, B. Hodoroaba, T. O'Hara, O. Vasilovici, L. Amarandi, R. W. Schrittwieser Jan 2019

Concentric Double Hollow Grid Cathode Discharges, C. T. Teodorescu-Soare, S. A. Irimiciuc, C. Ionita, D. G. Dimitriu, B. Hodoroaba, T. O'Hara, O. Vasilovici, L. Amarandi, R. W. Schrittwieser

Articles

A new cathode system, consisting of two concentric spherical hollow grids with two aligned orifices, is investigated by space-resolved Langmuir probe measurements and non-linear dynamics analysis. Negative biases of this spherical hollow grids arrangement lead to the formation of two complex space charge structures in the regions of the orifices. The overall dynamics of the current-voltage characteristic (I–V characteristic) of each discharge is characterized by strong oscillatory behaviour with various waveforms correlated with jumps in the static I–V characteristics. Space-resolved measurements through the two aligned orifices of the two grids show a peak increase of the electron temperature and particle …


Magnetic Field Sensor Based On A Tri-Microfiber Coupler Ring In Magnetic Fluid And A Fiber Bragg Grating, Fangfang Wei, Dejun Liu, Arun Kumar Mallik, Gerald Farrell, Qiang Wu, Gang-Ding Peng, Yuliya Semenova Jan 2019

Magnetic Field Sensor Based On A Tri-Microfiber Coupler Ring In Magnetic Fluid And A Fiber Bragg Grating, Fangfang Wei, Dejun Liu, Arun Kumar Mallik, Gerald Farrell, Qiang Wu, Gang-Ding Peng, Yuliya Semenova

Articles

In this paper we propose and investigate a novel magnetic field sensor based on a Tri-microfiber coupler combined with magnetic fluid and a fiber Bragg grating (FBG) in a ring. A sensitivity of 1306 pm/mT was experimentally demonstrated in the range of magnetic fields from 0 to 15 mT. The reflection peak in the output spectrum associated with the FBG serves as a reference point allowing to avoid ambiguity in determining the spectral shift induced by the magnetic field. Due to its high sensitivity at low magnetic fields, the proposed structure could be of high interest in low field biosensing …


Exploring Subcellular Responses Of Prostate Cancer Cells To X-Ray Exposure By Raman Mapping, Maciej Roman, Agnieszka Panek, Hugh Byrne, Tomasz P Wrobel, Esen Efeoglu, Czeslawa Paluszkiewicz, Wojciech Maria Kwiatek Jan 2019

Exploring Subcellular Responses Of Prostate Cancer Cells To X-Ray Exposure By Raman Mapping, Maciej Roman, Agnieszka Panek, Hugh Byrne, Tomasz P Wrobel, Esen Efeoglu, Czeslawa Paluszkiewicz, Wojciech Maria Kwiatek

Articles

Understanding the response of cancer cells to ionising radiation is a crucial step in modern radiotherapy. Raman microspectroscopy, together with Partial Least Squares Regression (PLSR) analysis has been shown to be a powerful tool for monitoring biochemical changes of irradiated cells on the subcellular level. However, to date, the majority of Raman studies have been performed using a single spectrum per cell, giving a limited view of the total biochemical response of the cell. In the current study, Raman mapping of the whole cell area was undertaken to ensure a more comprehensive understanding of the changes induced by X-ray radiation. …


Raman Spectroscopy Detects Biochemical Changes Due To Different Cell Culture Environments In Live Cells In Vitro, Mahmoud Gargotti, Esen Efeoglu, Hugh Byrne, Alan Casey Oct 2018

Raman Spectroscopy Detects Biochemical Changes Due To Different Cell Culture Environments In Live Cells In Vitro, Mahmoud Gargotti, Esen Efeoglu, Hugh Byrne, Alan Casey

Articles

The in vitro cell culture environment can impact on cell biochemistry and cell cycle. The manifestation of such substrate-induced changes in cell cycle in the Raman microspectroscopic profiles of cell cultures is investigated at the level of nucleolus, nucleus and cytoplasm. HeLa immortalised human cervical cells and HaCaT dermal cells were cultured on three different substrates, conventional polystyrene cell culture dishes, CaF2 slides as a commonly used Raman substrate, and glass slides coated with Collagen Rat Tail, as a mimic of the extra cellular matrix (ECM) environment. A cell cycle study, based on percentage DNA content, as determined using Propidium …


Significance Of A Non-Thermal Plasma Treatment On Ldpe Biodegradation With Pseudomonas Aeruginosa, Laurence Scally, Miroslav Gulan, Lars Weigang, Patrick Cullen, Vladimir Milosavljevic Oct 2018

Significance Of A Non-Thermal Plasma Treatment On Ldpe Biodegradation With Pseudomonas Aeruginosa, Laurence Scally, Miroslav Gulan, Lars Weigang, Patrick Cullen, Vladimir Milosavljevic

Articles

The use of plastics has spanned across almost all aspects of day to day life. Although their uses are invaluable, they contribute to the generation of a lot of waste products that end up in the environment and end up polluting natural habitats such as forests and the ocean. By treating low-density polyethylene (LDPE) samples with non-thermal plasma in ambient air and with an addition of 4% CO2, the biodegradation of the samples can be increased due to an increase in oxidative species causing better cell adhesion and acceptance on the polymer sample surface. It was, however, found that the …


Serialised Holography For Brand Protection And Authentication, Dinesh Vather, Izabela Naydenova, Dervil Cody, Monika Zawadzka, Suzanne Martin, Emilia Mihaylova, Stephen Curran, Paul Duffy, Josune Portillo, Daniel Connell, Stephen Mcdonnell, Vincent Toal Aug 2018

Serialised Holography For Brand Protection And Authentication, Dinesh Vather, Izabela Naydenova, Dervil Cody, Monika Zawadzka, Suzanne Martin, Emilia Mihaylova, Stephen Curran, Paul Duffy, Josune Portillo, Daniel Connell, Stephen Mcdonnell, Vincent Toal

Articles

The problems presented by counterfeit products and documentation are discussed. Limitations of existing holograms for anti-counterfeit applications are described. We describe the advantages of full holographic serialisation and the requirements in terms of materials and techniques for mass production of true serialised holograms. These requirements having been met, we report for the first time the mass production of fully serialised holograms. The novelty of approach consists of the direct use of product manufacturer’s information as the object in a holographic recording system along with a self-processing photopolymer and modular optical system to facilitate mass production of truly serialised volume holograms. …


Advancing Raman Microspectroscopy For Cellular And Subcellular Analysis: Towards In Vitro High Content Spectralomic Analysis, Hugh Byrne, Franck Bonnier, Alan Casey, Marcus Maher, Jennifer Mcintyre, Esen Efeoglu, Zeineb Farhane Jun 2018

Advancing Raman Microspectroscopy For Cellular And Subcellular Analysis: Towards In Vitro High Content Spectralomic Analysis, Hugh Byrne, Franck Bonnier, Alan Casey, Marcus Maher, Jennifer Mcintyre, Esen Efeoglu, Zeineb Farhane

Articles

In the confocal mode, Raman microspectroscopy can profile the biochemical content of biological cells at a subcellular level, and any changes to it by exogenous agents, such as therapeutic drugs or toxicants. As an exploration of the potential of the technique as a high content, label free analysis technique, this report reviews work to monitor the spectroscopic signatures associated with the uptake and response pathways of commercial chemotherapeutic agents and polymeric nanoparticles by human lung cells. It is demonstrated that the signatures are reproducible and characteristic of the cellular event, and can be used, for example, to identify the mode …


Multicomponent Analysis Using A Confocal Raman Microscope, Zhengyuan Tang, Sinead J. Barton, Thomas E. Ward, John P. Lowry, Michelle M. Doran, Hugh Byrne, Bryan M. Hennelly Jun 2018

Multicomponent Analysis Using A Confocal Raman Microscope, Zhengyuan Tang, Sinead J. Barton, Thomas E. Ward, John P. Lowry, Michelle M. Doran, Hugh Byrne, Bryan M. Hennelly

Articles

Measuring the concentration of multiple chemical components in a low volume aqueous mixture by Raman spectroscopy has received significant interest in the literature. All of the contributions to date focus on the design of optical systems that facilitate the recording of spectra with high signal-to-noise ratio, by collecting as many Raman scattered photons as possible. In this study, the confocal Raman microscope set-up is investigated for multicomponent analysis. Partial Least Squares Regression is used to quantify physiologically relevant aqueous mixtures of glucose, lactic acid, and urea. The predicted error is 17.81 mg/dL for glucose, 10.6 mg/dL for lactic acid and …


Raman Spectral Analysis For Rapid Screening Of Dengue Infection, Tahir Mahmood, Haq Nawaz, A. Ditta, M.I. Majeed, M.A. Hanif, N. Rashid, H.N. Bhatti, H.F. Nargis, M. Saleem, Franck Bonnier, Hugh Byrne May 2018

Raman Spectral Analysis For Rapid Screening Of Dengue Infection, Tahir Mahmood, Haq Nawaz, A. Ditta, M.I. Majeed, M.A. Hanif, N. Rashid, H.N. Bhatti, H.F. Nargis, M. Saleem, Franck Bonnier, Hugh Byrne

Articles

Infection with the dengue virus is currently clinically detected according to different biomarkers in human blood plasma, commonly measured by enzyme linked immunosorbent assays, including non-structural proteins (Ns1), immunoglobulin M (IgM) and immunoglobulin G (IgG). However, there is little or no mutual correlation between the biomarkers, as demonstrated in this study by a comparison of their levels in samples from 17 patients. As an alternative, the label free, rapid screening technique, Raman spectroscopy has been used for the characterisation/diagnosis of healthy and dengue infected human blood plasma samples. In dengue positive samples, changes in specific Raman spectral bands associated with …


Holographic Beam-Shaping Diffractive Diffusers Fabricated By Using Controlled Laser Speckle, Kevin Murphy, Vincent Toal, Izabela Naydenova, Suzanne Martin Apr 2018

Holographic Beam-Shaping Diffractive Diffusers Fabricated By Using Controlled Laser Speckle, Kevin Murphy, Vincent Toal, Izabela Naydenova, Suzanne Martin

Articles

A method for fabricating diffractive holographic optical diffusers is reported, allowing a high degree of control of the resulting diffuser characteristics. The method consists of recording a laser speckle pattern using a single carrier beam, with controlled speckle size and shape, in an acrylamide-based volume photopolymer. The multiple interferences that create the speckle pattern form the hologram. Results are presented verifying the diffusers are volume holographic in nature and the speckle pattern is recorded accurately in the photopolymer. Diffusers recorded by this method are analysed to characterise the optical performance of the diffusers and to illustrate their beam-shaping capabilities, particularly …


Studies Of Geometrical Profiling In Fabricated Tapered Optical Fbers Using Whispering Gallery Modes Spectroscopy, Vishnu Kavungal, Gerald Farrell, Qiang Wu, Arun Kumar Mallik, Yuliya Semenova Mar 2018

Studies Of Geometrical Profiling In Fabricated Tapered Optical Fbers Using Whispering Gallery Modes Spectroscopy, Vishnu Kavungal, Gerald Farrell, Qiang Wu, Arun Kumar Mallik, Yuliya Semenova

Articles

This paper experimentally demonstrates a method for geometrical profiling of asymmetries in fabricated thin microfiber tapers with waist diameters ranging from ∼10 to ∼50µm with submicron accuracy. The method is based on the analysis of whispering gallery mode resonances excited in cylindrical fiber resonators as a result of evanescent coupling of light propagating through the fiber taper. The submicron accuracy of the proposed method has been verified by SEM studies. The method can be applied as a quality control tool in fabrication of microfiber based devices and sensors or for fine-tuning of microfiber fabrication set-ups.


High Sensitivity Temperature Sensor Based On Singlemode-No-Core- Singlemode Fibre Structure And Alcohol, Ke Tiana, Gerald Farrell, Xianfan Wang, Yifan Xin, Yanqiu Du, Wenlei Yang, Haidong Liang, Elfed Lewis, Pengfei Wang Jan 2018

High Sensitivity Temperature Sensor Based On Singlemode-No-Core- Singlemode Fibre Structure And Alcohol, Ke Tiana, Gerald Farrell, Xianfan Wang, Yifan Xin, Yanqiu Du, Wenlei Yang, Haidong Liang, Elfed Lewis, Pengfei Wang

Articles

A high sensitivity temperature sensor based on a singlemode-no-core-singlemode (SNCS) fibre structure and surrounded with alcohol within a silica capillary is described. In this investigation, no-core fibre (NCF) is used as the multimode waveguide and alcohol is chosen as the temperature sensitive medium. By packaging the alcohol solution with a short length of NCF enclosed within a silica capillary, the surrounding temperature can be detected by monitoring the variations of transmission loss at a specific wavelength. The theoretical analysis predicts this temperature sensor can provide high sensitivity, and the experimental results support this. The maximum temperature sensitivity of the sample …