The Impact Of Simulated Image Acquisition Time Reduction On Image Quality And Parameters Of Myocardial Perfusion Imaging Using A Dedicated Cardiac Camera, Alireza Khatami Jan 2024

The Impact Of Simulated Image Acquisition Time Reduction On Image Quality And Parameters Of Myocardial Perfusion Imaging Using A Dedicated Cardiac Camera, Alireza Khatami

Electronic Thesis and Dissertation Repository

Heart disease is the second leading cause of death in Canada, highlighting the crucial role of early diagnosis in disease management. Myocardial perfusion imaging (MPI), is widely employed for this purpose, involves injecting a radiopharmaceutical into the body, imaging its distribution with a gamma camera, and revealing cardiac blood flow patterns. A significant challenge in MPI is the lengthy 8 to 10 minutes required for stress and rest imaging, potentially causing patient discomfort and compromising image quality due to movement. In a clinical study with 26 patients, post-processed data manipulation simulated a reduction in MPI imaging time. The findings indicated …


Improving The Reliability And Accessibility Of Ct Perfusion Imaging In Acute Ischemic Stroke, Kevin J. Chung Feb 2023

Improving The Reliability And Accessibility Of Ct Perfusion Imaging In Acute Ischemic Stroke, Kevin J. Chung

Electronic Thesis and Dissertation Repository

CT perfusion (CTP) imaging is a validated treatment decision support tool in acute ischemic stroke. Automated analysis of CTP cerebral blood flow (CBF) and Tmax maps produces estimates of ischemic core and penumbra volumes used to determine target mismatch profiles for treatment. However, availability and utilization of CTP is low due to diagnostic variability between CTP software and technical, logistical, and radiation dose considerations that may limit its routine adoption. The objective of this doctoral research was to improve the reliability and accessibility of CTP by (1) improving diagnostic agreement between CTP software, (2) enabling perfusion imaging with standard acute …


Technical Adaptations For Cardiac Sodium Mri, Taylor L. Marcus Oct 2022

Technical Adaptations For Cardiac Sodium Mri, Taylor L. Marcus

Electronic Thesis and Dissertation Repository

Cardiac sodium (Na+) MRI has the potential to unveil relationships between chronic kidney disease (CKD) and cardiovascular disease (CVD). Unfortunately, this modality requires many technical adaptations before it’s possible to extract and compare image data between individuals. This study investigated whether cardiac electrocardiogram (ECG) gating could improve image quality, and whether a uniform phantom could increase signal uniformity if a surface coil is used to acquire the image. Healthy participants were imaged with a custom-built surface coil and 3.0-T MR system. Cardiac gated images presented with a decreased signal-to-noise ratio (SNR), but intensity correction significantly increased image signal …


Development Of Advanced Mr-Guided Adaptive Radiation Therapy Methods For Head & Neck Cancers On The 1.5t Mr-Linac, Brigid Mcdonald Aug 2022

Development Of Advanced Mr-Guided Adaptive Radiation Therapy Methods For Head & Neck Cancers On The 1.5t Mr-Linac, Brigid Mcdonald

Dissertations & Theses (Open Access)

The 1.5T hybrid MRI/linear accelerator (MR-linac) has recently been introduced into clinical practice and used for the treatment of head and neck cancers (HNC). This device enables on-line adaptive radiation therapy (ART) based on anatomical changes throughout treatment and variations in patient position. This novel technology also has the potential for advanced ART strategies such as dose-optimized ART, in which the treatment plan is optimized based on the accumulated dose over previous fractions, or biological image-guided ART, in which the plan is adapted based on individual tumor response as measured through quantitative imaging techniques such as diffusion-weighted imaging (DWI). The …


Absolute Quantification Of Tc-99m Activity Distributions Using A Planar Molecular Breast Imaging Commercial System, Benjamin P. Lopez Aug 2022

Absolute Quantification Of Tc-99m Activity Distributions Using A Planar Molecular Breast Imaging Commercial System, Benjamin P. Lopez

Dissertations & Theses (Open Access)

Molecular breast imaging (MBI) uses two dedicated-breast semiconductor detectors to visualize the preferential uptake of technetium-99m-sestamibi (99mTc-sestamibi) by breast cancer cells relative to surrounding benign breast tissues. Clinically, MBI is used primarily as a supplementary tool to standard-of-care mammography because of its improved detection of breast cancers, especially in women with mammographically-dense breasts. Because of a lack of image corrections, MBI applications are currently limited to qualitative evaluations of relative pixel intensities between image regions with suspected lesions and normal tissue.

The objective of this dissertation was to use Monte Carlo simulations to better characterize the MBI imaging …


Quantitative Mri And 3d-Printing For Monitoring Periprosthetic Joint Infection, Greg Hong Jul 2022

Quantitative Mri And 3d-Printing For Monitoring Periprosthetic Joint Infection, Greg Hong

Electronic Thesis and Dissertation Repository

Joint replacements are becoming increasingly commonplace with over 130,000 joint arthroplasties being performed annually in Canada. Although joint replacement surgery is highly successful, implants do occasionally fail and need to be replaced via costly and difficult revision surgery. Periprosthetic joint infection (PJI) has recently become the leading reason for revision of both hip and knee replacements, which is unfortunate because PJI is difficult to diagnose and treat effectively; diagnosis is made particularly difficult by the lack of established non-invasive (imaging) means of evaluating PJI. This thesis aims to demonstrate that magnetic resonance imaging (MRI) has potential for diagnosing and monitoring …


Community Health Interventions To Reduce The Burden Of Radon-Related Lung Cancer, Benjamin Weaver Jan 2021

Community Health Interventions To Reduce The Burden Of Radon-Related Lung Cancer, Benjamin Weaver

Family Medicine Clerkship Student Projects

Exposure to radon is the second leading cause of lung cancer in the United States. One in seven homes in Vermont has elevated levels of radon, but most patients are unaware of radon as a risk factor for lung cancer or that radon testing and mitigation services are available to them. To promote increased testing and mitigation of radon we screened patients presenting to a Family Medicine practice in Vermont about whether they had had these services done in their home. We also developed a patient education resource for providers to give to patients who had more questions about radon …


Hyperpolarized Carbon-13 Magnetic Resonance Measurements Of Tissue Perfusion And Metabolism, Keith Michel Dec 2020

Hyperpolarized Carbon-13 Magnetic Resonance Measurements Of Tissue Perfusion And Metabolism, Keith Michel

Dissertations & Theses (Open Access)

Hyperpolarized Magnetic Resonance Imaging (HP MRI) is an emerging modality that enables non-invasive interrogation of cells and tissues with unprecedented biochemical detail. This technology provides rapid imaging measurements of the activity of a small quantity of molecules with a strongly polarized nuclear magnetic moment. This polarization is created in a polarizer separate from the imaging magnet, and decays continuously towards a non-detectable thermal equilibrium once the imaging agent is removed from the polarizer and administered by intravenous injection. Specialized imaging strategies are therefore needed to extract as much information as possible from the HP signal during its limited lifetime.

In …


Investigating The Metabolic Progression Of Glioblastoma With Hyperpolarized Magnetic Resonance, Travis Salzillo Aug 2020

Investigating The Metabolic Progression Of Glioblastoma With Hyperpolarized Magnetic Resonance, Travis Salzillo

Dissertations & Theses (Open Access)

Rapid diagnosis and therapeutic monitoring of aggressive diseases such as glioblastoma (GBM) can improve patient survival by providing physicians the time to optimally deliver treatment. This includes early in development, while the tumor is still manageable, or following initial therapy, when alternative treatments should be considered. The main goal of this project was to determine whether metabolic imaging with hyperpolarized magnetic resonance spectroscopy (MRS) could detect changes in tumor progression more rapidly than conventional anatomic magnetic resonance imaging (MRI) in patient-derived GBM murine models. To comprehensively capture the dynamic nature of cancer metabolism, in vivo pyruvate-to-lactate conversion with hyperpolarized MRI, …


Development Of Fully Balanced Ssfp And Computer Vision Applications For Mri-Assisted Radiosurgery (Mars), Jeremiah Sanders May 2020

Development Of Fully Balanced Ssfp And Computer Vision Applications For Mri-Assisted Radiosurgery (Mars), Jeremiah Sanders

Dissertations & Theses (Open Access)

Prostate cancer is the second most common cancer in men and the second-leading cause of cancer death in men. Brachytherapy is a highly effective treatment option for prostate cancer, and is the most cost-effective initial treatment among all other therapeutic options for low to intermediate risk patients of prostate cancer. In low-dose-rate (LDR) brachytherapy, verifying the location of the radioactive seeds within the prostate and in relation to critical normal structures after seed implantation is essential to ensuring positive treatment outcomes.

One current gap in knowledge is how to simultaneously image the prostate, surrounding anatomy, and radioactive seeds within the …


Scintillation Event Localization In Novel Hemi-Ellipsoid Detector For Spect, Hanif R. Soysal May 2019

Scintillation Event Localization In Novel Hemi-Ellipsoid Detector For Spect, Hanif R. Soysal

LSU Master's Theses

A high sensitivity Cardiac SPECT system using hemi-ellipsoid crystals with pinhole collimation was previously proposed by Dey et al. To investigate detector resolution for this design, the scintillation light spread on a monolithic hemi-ellipsoidal CsI crystal was simulated using Geant4 Monte Carlo. The expected distribution of scintillation light on the outer surface of the crystal from photoelectric absorption events was obtained from the simulations for selected points inside the crystal. Two sets of simulations were performed. For the first set, a look-up table (LUT) of 12 points was created and each point mapped to its expected light distribution—four points at …


Design And Development Of A Phantom For Tomosynthesis With Potential For Automated Analysis Via The Cloud., David Goodenough, Josh Levy, Hildur Olafsdottir, Ingvi Olafsson May 2018

Design And Development Of A Phantom For Tomosynthesis With Potential For Automated Analysis Via The Cloud., David Goodenough, Josh Levy, Hildur Olafsdottir, Ingvi Olafsson

Radiology Faculty Publications

This paper describes Development of a Phantom for Tomosynthesis with Potential for Automated Analysis via the Cloud. Several studies are underway to investigate the effectiveness of Tomosynthesis Mammographic Image Screening, including the large TMIST project as funded by the National Cancer Institute https://www.cancer.gov/about-cancer/treatment/clinical-trials/nci-supported/tmist. The development of the phantom described in this paper follows initiatives from the FDA, the AAPM TG245 task group, and European Reference Organization (EUREF) for Quality Assured Breast Screening and Diagnostic Services Committee report noting, that no formal endorsement nor recommendation for use has been sought, or granted by any of these groups. This paper reports on …


Development Of 3d-Printed Patient Specific Bolus For Clinical Use In Total Scalp Irradiation, Garrett Baltz May 2018

Development Of 3d-Printed Patient Specific Bolus For Clinical Use In Total Scalp Irradiation, Garrett Baltz

Dissertations & Theses (Open Access)

Total scalp irradiation (TSI) is a specialized radiation therapy technique that aims to deliver a uniform dose to the entire scalp. Original electron-based TSI techniques had limited homogeneity due to hot and cold spots created at field junctions due to the multiple matched fields that were required to treat the entire scalp. The transition to photon volumetric-modulated arc therapy based TSI techniques has improved homogeneity, to the point where non-conformal bolus is now a limiting factor. Bolus is required to build-up full dose to the scalp surface in total scalp irradiation. Creating bolus that is conformal to the scalp is …


Advances In Dual-Energy Computed Tomography Imaging Of Radiological Properties, Dong Han Jan 2018

Advances In Dual-Energy Computed Tomography Imaging Of Radiological Properties, Dong Han

Theses and Dissertations

Dual-energy computed tomography (DECT) has shown great potential in the reduction of uncertainties of proton ranges and low energy photon cross section estimation used in radiation therapy planning. The work presented herein investigated three contributions for advancing DECT applications. 1) A linear and separable two-parameter DECT, the basis vector model (BVM) was used to estimate proton stopping power. Compared to other nonlinear two-parameter models in the literature, the BVM model shows a comparable accuracy achieved for typical human tissues. This model outperforms other nonlinear models in estimations of linear attenuation coefficients. This is the first study to clearly illustrate the …


Method And Phantom To Study Combined Effects Of In-Plane (X,Y) And Z-Axis Resolution For 3d Ct Imaging., David Goodenough, Josh Levy, Smari Kristinsson, Jesper Fredriksson, Hildur Olafsdottir, Austin Healy Sep 2016

Method And Phantom To Study Combined Effects Of In-Plane (X,Y) And Z-Axis Resolution For 3d Ct Imaging., David Goodenough, Josh Levy, Smari Kristinsson, Jesper Fredriksson, Hildur Olafsdottir, Austin Healy

Radiology Faculty Publications

Increasingly, the advent of multislice CT scanners, volume CT scanners, and total body spiral acquisition modes has led to the use of Multi Planar Reconstruction and 3D datasets. In considering 3D resolution properties of a CT system it is important to note that both the in-plane (x,y) and z-axis (slice thickness) influence the visual-ization and detection of objects within the scanned volume. This study investigates ways to consider both the in-plane resolution and the z-axis resolution in a single phantom wherein analytic or visualized analysis can yield information on these combined effects. A new phantom called the "Wave Phantom" is …


Optimizing Respiratory Gated Intensity Modulated Radiation Therapy Planning And Delivery Of Early-Stage Non-Small Cell Lung Cancer, Ilma Xhaferllari Jul 2016

Optimizing Respiratory Gated Intensity Modulated Radiation Therapy Planning And Delivery Of Early-Stage Non-Small Cell Lung Cancer, Ilma Xhaferllari

Electronic Thesis and Dissertation Repository

Stereotactic ablative body radiotherapy (SABR) is the standard of care for inoperable early-stage non-small cell lung cancer (NSCLC) patients. However, thoracic tumours are susceptible to respiratory motion and, if unaccounted for, can potentially lead to dosimetric uncertainties. Respiratory gating is one method that limits treatment delivery to portions of the respiratory cycle, but when combined with intensity-modulated radiotherapy (IMRT), requires rigorous verification. The goal of this thesis is to optimize respiratory gated IMRT treatment planning and develop image-guided strategies to verify the dose delivery for future early-stage NSCLC patients.

Retrospective treatment plans were generated for various IMRT delivery techniques, including …


Role Of Cerebrovascular Abnormality In Neurodegenerative Disease And Subcortical Ischemic Disease: Ct Perfusion And Pet Imaging, Jun Yang Sep 2015

Role Of Cerebrovascular Abnormality In Neurodegenerative Disease And Subcortical Ischemic Disease: Ct Perfusion And Pet Imaging, Jun Yang

Electronic Thesis and Dissertation Repository

Clinical studies indicate that about 30% ~ 50% of patients have cognitive impairment after the first or recurrent stroke. Ischemic injury, particularly subcortical lesions, caused by stroke has been demonstrated to further exacerbate cognitive impairment of Alzheimer’s disease (AD) and vascular dementia. However, the mechanisms whereby cerebrovascular abnormalities contribute to neurodegeneration at early stage of disease and eventually to cognitive decline remain unclear. CT perfusion and positron emission tomography (PET) were used to investigate early mechanisms in a rat comorbid model of cerebral ischemia (CI) and β-amyloid (Aβ, a pathological hallmark of AD) toxicity, and in patients with small subcortical …


Characterization Of Low Density Intracranial Lesions Using Dual-Energy Computed Tomography, Jessica L. Nute May 2015

Characterization Of Low Density Intracranial Lesions Using Dual-Energy Computed Tomography, Jessica L. Nute

Dissertations & Theses (Open Access)

Calcific and hemorrhagic foci of susceptibility are frequently encountered on routine brain MR studies. Both etiologies cause variations in local magnetic field strength, leading to dark regions on the MR images that cannot be classified. Single-energy CT (SECT) can be used to identify lesions with attenuation over 100 HU as calcific, however lesions with lower attenuation cannot be reliably identified. While calcific lesions are unlikely to cause harm, hemorrhagic lesions carry a risk of subsequent intracranial bleeding; as such, identification of hemorrhage is vital in preventing the inappropriate use of anticoagulant medications in patients with hemorrhagic lesions.

Given there currently …


Real-Time Mri-Guided Catheter Tracking Using Hyperpolarized Silicon Particles, Nicholas Whiting, Jingzhe Hu, Jay V. Shah, Maja C. Cassidy, Erik Cressman, Niki Zacharias Millward, David G. Menter, Charles M. Marcus, Pratip K. Bhattacharya Jan 2015

Real-Time Mri-Guided Catheter Tracking Using Hyperpolarized Silicon Particles, Nicholas Whiting, Jingzhe Hu, Jay V. Shah, Maja C. Cassidy, Erik Cressman, Niki Zacharias Millward, David G. Menter, Charles M. Marcus, Pratip K. Bhattacharya

Nicholas Whiting

Visualizing the movement of angiocatheters during endovascular interventions is typically accomplished using x-ray fluoroscopy. There are many potential advantages to developing magnetic resonance imaging-based approaches that will allow three-dimensional imaging of the tissue/vasculature interface while monitoring other physiologically-relevant criteria, without exposing the patient or clinician team to ionizing radiation. Here we introduce a proof-of-concept development of a magnetic resonance imaging-guided catheter tracking method that utilizes hyperpolarized silicon particles. The increased signal of the silicon particles is generated via low-temperature, solid-state dynamic nuclear polarization, and the particles retain their enhanced signal for ≥40 minutes—allowing imaging experiments over extended time durations. The …


A Nonrigid Registration Method For Correcting Brain Deformation Induced By Tumor Resection, Yixun Liu, Chengjun Yao, Fotis Drakopoulos, Jinsong Wu, Liangfu Zhou, Nikos Chrisochoides Jan 2014

A Nonrigid Registration Method For Correcting Brain Deformation Induced By Tumor Resection, Yixun Liu, Chengjun Yao, Fotis Drakopoulos, Jinsong Wu, Liangfu Zhou, Nikos Chrisochoides

Computer Science Faculty Publications

Purpose: This paper presents a nonrigid registration method to align preoperative MRI with intraoperative MRI to compensate for brain deformation during tumor resection. This method extends traditional point-based nonrigid registration in two aspects: (1) allow the input data to be incomplete and (2) simulate the underlying deformation with a heterogeneous biomechanical model.

Methods: The method formulates the registration as a three-variable (point correspondence, deformation field, and resection region) functional minimization problem, in which point correspondence is represented by a fuzzy assign matrix; Deformation field is represented by a piecewise linear function regularized by the strain energy of a heterogeneous biomechanical …


Scanned Ion Beam Therapy For Thoracic Tumors, John Gordon Eley Dec 2013

Scanned Ion Beam Therapy For Thoracic Tumors, John Gordon Eley

Dissertations & Theses (Open Access)

Although frequently cured of Hodgkin lymphoma, adolescents and young adults can develop radiation induced second cancers. These patients could potentially benefit from scanned ion radiotherapy yet likely would require motion mitigation strategies. In theory, four-dimensional (4D) optimization of ion beam fields for individual motion states of respiration can enable superior sparing of healthy tissue near moving targets, compared to other motion mitigation strategies. Furthermore, carbon-ion therapy can sometimes provide greater relative biological effectiveness (RBE) for cell sterilization in a target but nearly equivalent RBE in tissue upstream of the target, compared to proton therapy. Thus, we expected that for some …


The Impact Of Lateral Electron Disequilibrium On Stereotactic Body Radiation Therapy Of Lung Cancer, Brandon Disher Aug 2013

The Impact Of Lateral Electron Disequilibrium On Stereotactic Body Radiation Therapy Of Lung Cancer, Brandon Disher

Electronic Thesis and Dissertation Repository

Stereotactic Body Radiation Therapy (SBRT) is an effective treatment option for patients with inoperable early-stage lung cancer. SBRT uses online image-guidance technology [e.g. cone-beam CT (CBCT)] to focus small-fields of high energy x-rays onto a tumour to deliver ablative levels of radiation dose (e.g. 54 Gy) in a few treatment fractions (e.g. 3). For the combination of these treatment parameters and a low density lung, lateral electron disequilibrium (LED) can potentially occur, reducing lung and tumour doses. The goal of this thesis was to determine the impact of LED on stereotactic body radiation therapy for lung cancer.

The effect of …


Technology Assessment Of Automated Atlas Based Segmentation In Prostate Bed Contouring, Jeremiah Hwee, Alexander Louie, Stewart Gaede, Glenn Bauman, David D'Souza, Tracy Sexton, Michael Lock, Belal Ahmad, George Rodrigues Nov 2012

Technology Assessment Of Automated Atlas Based Segmentation In Prostate Bed Contouring, Jeremiah Hwee, Alexander Louie, Stewart Gaede, Glenn Bauman, David D'Souza, Tracy Sexton, Michael Lock, Belal Ahmad, George Rodrigues

Michael Lock

BACKGROUND: Prostate bed (PB) contouring is time consuming and associated with inter-observer variability. We evaluated an automated atlas-based segmentation (AABS) engine in its potential to reduce contouring time and inter-observer variability.

METHODS: An atlas builder (AB) manually contoured the prostate bed, rectum, left femoral head (LFH), right femoral head (RFH), bladder, and penile bulb of 75 post-prostatectomy cases to create an atlas according to the recent RTOG guidelines. 5 other Radiation Oncologists (RO) and the AABS contoured 5 new cases. A STAPLE contour for each of the 5 patients was generated. All contours were anonymized and sent back to the …


Radiation Dose Distributions In Three Dimensions From Tomographic Optical Density Scanning Of Polymer Gels: Ii. Optical Properties Of The Bang Polymer Gel, Yevgeniya Zastavker, Marek Maryanski, John Gore Jun 2012

Radiation Dose Distributions In Three Dimensions From Tomographic Optical Density Scanning Of Polymer Gels: Ii. Optical Properties Of The Bang Polymer Gel, Yevgeniya Zastavker, Marek Maryanski, John Gore

Yevgeniya V. Zastavker

A newly developed method of radiation dosimetry makes use of the optical properties of polymer gels. The dose-response mechanism relies on the production of light-scattering polymer micro-particles in the gel at each site of radiation absorption. The scattering produces an attenuation of transmitted light intensity that is directly related to the dose and independent of dose rate. For the BANG polymer gel (bis, acrylamide, nitrogen, and gelatin) the shape of the dose-response curve depends on the fraction of the cross-linking monomer in the initial mixture and on the wavelength of light. At 500 nm the attenuation coefficient (μ) increases by …


Mri-Based Attenuation Correction In Emission Computed Tomography, Harry R. Marshall May 2012

Mri-Based Attenuation Correction In Emission Computed Tomography, Harry R. Marshall

Electronic Thesis and Dissertation Repository

The hybridization of magnetic resonance imaging (MRI) with positron emission tomography (PET) or single photon emission computed tomography (SPECT) enables the collection of an assortment of biological data in spatial and temporal register. However, both PET and SPECT are subject to photon attenuation, a process that degrades image quality and precludes quantification. To correct for the effects of attenuation, the spatial distribution of linear attenuation coefficients (μ-coefficients) within and about the patient must be available. Unfortunately, extracting μ-coefficients from MRI is non-trivial. In this thesis, I explore the problem of MRI-based attenuation correction (AC) in emission tomography.

In particular, I …


Hearts And Minds: Examining The Evolution Of The Egyptian Excerebration And Evisceration Traditions Through The Impact Mummy Database, Andrew D. Wade Apr 2012

Hearts And Minds: Examining The Evolution Of The Egyptian Excerebration And Evisceration Traditions Through The Impact Mummy Database, Andrew D. Wade

Electronic Thesis and Dissertation Repository

Egyptian mummification and funerary rituals were a transformative process, making the deceased a pure being; free of disease, injury, and disfigurements, as well as ethical and moral impurities. Consequently, the features of mummification available to specific categories of individuals hold social and ideological significance. This study refutes long-held classical stereotypes, particularly dogmatic class associations; demonstrates the apocryphal nature of universal heart retention; and expands on the purposes of excerebration and evisceration implied by synthetic and radiological analyses.

Features of the embalming traditions, specifically the variable excerebration and evisceration traditions, represented the Egyptian view of death. Fine-grain analyses, through primary imaging …


Mesothelioma - Epidemiology And Management, Patricia Tai, Edward Yu, Avi Assouline, Kurian Joseph Sep 2011

Mesothelioma - Epidemiology And Management, Patricia Tai, Edward Yu, Avi Assouline, Kurian Joseph

Edward Yu

Mesothelioma is an uncommon tumor. It has a latency period of 20-40 years. The most important risk factor is asbestos exposure. Prognosis of mesothelioma is generally poor with high case-fatality rate, and research to improve the outcome of this disease is on-going worldwide. Due to its rarity, management by a multidisciplinary team with experience is recommended. Carefully selected patients may benefit from tri-modality (surgery, radiotherapy and chemotherapy) treatment. The management of pleural and peritoneal mesothelioma is summarized in this review. Recent advances in chemotherapy and biologic response modifiers are promising.


Lung Cancer Epidemiology – A Global View, Patricia Tai, Edward Yu, Rashmi Koul, Arbind Dubey Sep 2011

Lung Cancer Epidemiology – A Global View, Patricia Tai, Edward Yu, Rashmi Koul, Arbind Dubey

Edward Yu

Smoking, air pollution and radon exposure are causally related to lung cancer. This review analyzes trends of smoking habits by age, sex and ethnicity and their correlation with incidence and mortality of lung cancer. Unfortunately the use of tobacco by adolescents is on the rise. Most developed countries are still showing the rising trend of mortality in female smokers. In Asia, cigarette smoking has become a major health risk with one in three of all cigarettes in the world today are smoked in China. Estimated one hundred million young ( < 29 years old) Chinese smokers will eventually die from lung …


In-Vivo Ct Dosimetry During Virtual Colonoscopy, Jonathon W. Mueller Aug 2011

In-Vivo Ct Dosimetry During Virtual Colonoscopy, Jonathon W. Mueller

Dissertations & Theses (Open Access)

Virtual colonoscopy (VC) is a minimally invasive means for identifying colorectal polyps and colorectal lesions by insufflating a patient’s bowel, applying contrast agent via rectal catheter, and performing multi-detector computed tomography (MDCT) scans. The technique is recommended for colonic health screening by the American Cancer Society but not funded by the Centers for Medicare and Medicaid Services (CMS) partially because of potential risks from radiation exposure. To date, no in‐vivo organ dose measurements have been performed for MDCT scans; thus, the accuracy of any current dose estimates is currently unknown.

In this study, two TLDs were affixed to the inner …


Thoracic Radiotherapy Treatment Planning With Cine Pet/Ct, Adam C. Riegel May 2010

Thoracic Radiotherapy Treatment Planning With Cine Pet/Ct, Adam C. Riegel

Dissertations & Theses (Open Access)

Purpose: Respiratory motion causes substantial uncertainty in radiotherapy treatment planning. Four-dimensional computed tomography (4D-CT) is a useful tool to image tumor motion during normal respiration. Treatment margins can be reduced by targeting the motion path of the tumor. The expense and complexity of 4D-CT, however, may be cost-prohibitive at some facilities. We developed an image processing technique to produce images from cine CT that contain significant motion information without 4D-CT. The purpose of this work was to compare cine CT and 4D-CT for the purposes of target delineation and dose calculation, and to explore the role of PET in target …