Open Access. Powered by Scholars. Published by Universities.®

Radiology Commons

Open Access. Powered by Scholars. Published by Universities.®

Analytical, Diagnostic and Therapeutic Techniques and Equipment

2020

Institution
Keyword
Publication
Publication Type

Articles 1 - 17 of 17

Full-Text Articles in Radiology

Conference Proceedings: Aurora Scientific Day 2020 Oct 2020

Conference Proceedings: Aurora Scientific Day 2020

Journal of Patient-Centered Research and Reviews

Abstracts published in this supplement were among those presented at the 46th annual Aurora Scientific Day research symposium, held virtually on May 20, 2020. The symposium provides a forum for describing research studies conducted by faculty, fellows, residents, and allied health professionals affiliated with Wisconsin-based Aurora Health Care, a part of the Advocate Aurora Health health system, which publishes the Journal of Patient-Centered Research and Reviews.


Pathophysiology And Proteogenomics Of Post-Infectious And Post-Hemorrhagic Hydrocephalus In Infants, Albert M. Isaacs Aug 2020

Pathophysiology And Proteogenomics Of Post-Infectious And Post-Hemorrhagic Hydrocephalus In Infants, Albert M. Isaacs

Arts & Sciences Electronic Theses and Dissertations

Post-infectious (PIH) and post-hemorrhagic (PHH) hydrocephalus occur as sequalae of neonatal sepsis or intraventricular hemorrhage (IVH) of prematurity, respectively. Together, PIH and PHH represent the most common form of infantile hydrocephalus, the most common indication for neurosurgery in children globally, and the leading cause of neurological morbidity and mortality worldwide. The lack of understanding of the pathophysiology of PIH and PHH, particularly with regards to the host central nervous system response to the antecedent infection and hemorrhage, perturbation of differentiating neural stems in the ventricular (VZ) and subventricular (SVZ) zones, and damage to periventricular white matter (PVWM) tracts carrying sensorimotor …


Detection Of Left Ventricular Thrombi On Cardiac Magnetic Resonance Viability Studies, Donya Ahmed Alhassan, Khawaja Bilal Waheed, Muhammad Nasim Sharif, Muhammad Zia Ulhassan, Fazal Ghaffar, Khaled Saleh Saleem, Emad Fouad Mahmoud Said, Bayan Mohammed Altalaq, Zechariah Jebakumar Arulanantham, Ahmad Omar Qarmash Aug 2020

Detection Of Left Ventricular Thrombi On Cardiac Magnetic Resonance Viability Studies, Donya Ahmed Alhassan, Khawaja Bilal Waheed, Muhammad Nasim Sharif, Muhammad Zia Ulhassan, Fazal Ghaffar, Khaled Saleh Saleem, Emad Fouad Mahmoud Said, Bayan Mohammed Altalaq, Zechariah Jebakumar Arulanantham, Ahmad Omar Qarmash

Journal of the Saudi Heart Association

Objective: To highlight detection of left ventricular thrombi on cardiac magnetic resonance (CMR) viability studies.

Method: This retrospective observational study was conducted in the Radiology Department at our Hospital in Dhahran, from April 2015-2019. All recently re-perfused (post-percutaneous coronary intervention/ PCI) patients with ST-segment elevation myocardial infarctions (STEMI), having low ejection fractions (

Results: Of the 125 patients, most were men (71.2%) with a mean age of 56.78 years. Eleven patients had left ventricular thrombi (8.8%), and most of these were anterior wall infarctions with low ejection fractions (

Conclusion: Left ventricular thrombi can be detected on cardiac viability studies …


Investigating The Metabolic Progression Of Glioblastoma With Hyperpolarized Magnetic Resonance, Travis Salzillo Aug 2020

Investigating The Metabolic Progression Of Glioblastoma With Hyperpolarized Magnetic Resonance, Travis Salzillo

Dissertations & Theses (Open Access)

Rapid diagnosis and therapeutic monitoring of aggressive diseases such as glioblastoma (GBM) can improve patient survival by providing physicians the time to optimally deliver treatment. This includes early in development, while the tumor is still manageable, or following initial therapy, when alternative treatments should be considered. The main goal of this project was to determine whether metabolic imaging with hyperpolarized magnetic resonance spectroscopy (MRS) could detect changes in tumor progression more rapidly than conventional anatomic magnetic resonance imaging (MRI) in patient-derived GBM murine models. To comprehensively capture the dynamic nature of cancer metabolism, in vivo pyruvate-to-lactate conversion with hyperpolarized MRI, …


Development Of A Ct Metal Artifact Management Algorithm For Proton Therapy Planning (Ampp) For Head And Neck Cancer Patients, Daniela Branco Aug 2020

Development Of A Ct Metal Artifact Management Algorithm For Proton Therapy Planning (Ampp) For Head And Neck Cancer Patients, Daniela Branco

Dissertations & Theses (Open Access)

Purpose: Dental amalgams (high Z materials) are common sources of artifacts in Head and Neck (HN) images. Commercial artifact reduction techniques have been offered, but many are impractical, produce inaccurate CT images or are not clinically available, thus not widely implemented. The goal of this work is to use CT gantry tilts to develop and evaluate a stereoscopic HN metal artifact management algorithm and investigate its improvement in proton treatment planning.

Methods: The in-house CT metal artifact management method for proton planning (AMPP) uses two angled CT scans to generate a single image set with no metal artifacts posterior …


Mapping Gadolinium Contrast In A Complex Ionic And Photosynthesis Environment Of Pineapple By Near-Infrared And X-Ray Imaging, Subhendra Sarkar, Zoya Vinokur, Chen Xu, Tetiana Soloviova, Amina Shahbaz, Aldona Gjoni Jul 2020

Mapping Gadolinium Contrast In A Complex Ionic And Photosynthesis Environment Of Pineapple By Near-Infrared And X-Ray Imaging, Subhendra Sarkar, Zoya Vinokur, Chen Xu, Tetiana Soloviova, Amina Shahbaz, Aldona Gjoni

Publications and Research

This work explores the diffusivity of a lanthanide complex, Eovist (Gadolinium-Ethoxy Benzyl Diethylenetriamine pentaacetate) that is stable in neutral media but is not in acidic environment. In the current work an acidic fruit model like pineapple that is rich in transition metals was used and a possible transmetallation reaction among Eovist and transition metal complexes was tested using X-ray imaging. Another goal of this work was to perturb the usual and the unusual photosynthesis systems that pineapple has maintained for millions of years during the evolution of circadian genes for efficient water conservation by dark photosynthesis. To detect such photosynthesis …


Dosimetric Comparison Of Hypofractionated Prostate Radiation With Simultaneous Integrated Boost And Conventional Fractionation With Sequential Boost, Kristina Sammon Jul 2020

Dosimetric Comparison Of Hypofractionated Prostate Radiation With Simultaneous Integrated Boost And Conventional Fractionation With Sequential Boost, Kristina Sammon

Culminating Experience Projects

Introduction: Hypofractionated treatment delivery regimens are associated with better overall long-term disease control for prostate cancer. For patients with high-risk disease, there may be an indication for treatment of the surrounding pelvic lymph nodes for better over-all disease control. In order to achieve a hypofractionated regimen with treatment to the surrounding pelvic lymph nodes a simultaneous integrated boost technique is employed. There are concerns regarding achievability of target dose coverage and limitation of dose to the surrounding organs at risk with this fractionation.

Methods: This study is a retrospective dosimetric analysis of 7 randomly selected patients with high-risk prostate cancer. …


A Comparison Between Rectal Dose In Prostate Radiotherapy Patients Treated With Spaceoar Hydrogel Present Versus Patients Treated Without Spaceoar Hydrogel., David Desano Jul 2020

A Comparison Between Rectal Dose In Prostate Radiotherapy Patients Treated With Spaceoar Hydrogel Present Versus Patients Treated Without Spaceoar Hydrogel., David Desano

Culminating Experience Projects

Introduction: External beam radiation therapy is a common treatment option for prostate cancer patients with localized disease. Radiation-induced side effects associated with the rectum can impact a patient’s ability to complete treatment or affect the quality of life years after radiation treatment. Spaceoar hydrogel has been developed to reduce radiation dose to nearby pelvis structures, and therefore decreasing potential side effects.

Methods: A total of 20 patients who received definitive radiation therapy to the prostate and seminal vesicles were selected and placed into 2 groups (10 spaceoar, 10 non-spaceoar). The individuals’ age ranged from 60 to 79 years old with …


Dosimetric Effect When Treating Multiple Lesion Srs Using Vmat With And Without Jaw Tracking, Mindy Bui Jul 2020

Dosimetric Effect When Treating Multiple Lesion Srs Using Vmat With And Without Jaw Tracking, Mindy Bui

Culminating Experience Projects

The main purpose of this study was to determine if jaw tracking or non-jaw tracking is the superior technique for patients with multiple brain metastasis that are treated with Volumetric Modulated Radiation Therapy (VMAT) Stereotactic Radiosurgery (SRS). Doses to the organs at risk (OAR) and the target volumes were analyzed using the dose volume histogram (DVH) and dose statistics for each plan. The goal of this study included analyzing the dosimetric effect on the organs at risk and the normal tissue when using jaw tracking versus non jaw tracking. The pros and cons for each technique were identified as well …


The Air Gap Effect Between A Bolus And The Skin Surface For Chest Wall Irradiation, Marisa Clark Jul 2020

The Air Gap Effect Between A Bolus And The Skin Surface For Chest Wall Irradiation, Marisa Clark

Culminating Experience Projects

Planning technique and bolus choice are important aspects in planning chest wall irradiation (CWI). Many previous studies have tested various combinations of photon energies, electron energies, bolus types and sizes, air gaps sizes, and treatment methods. This study aims to assess the effect of smaller, clinically relevant air gap sizes on specific chest wall treatments using a variety of common bolus types. Due to the Covid-19 pandemic, no data was able to be collected and was instead fabricated by the researcher. Four different treatment plans were created on a phantom patient using various energies of photons (6MV and 10MV) and …


Internal Hernia As A Late Complication Of Roux-En-Y Gastric Bypass Procedure, Samantha Purton, Gabriel Meshekow, My Myers, Edgar Mercado, Allan Katz Jun 2020

Internal Hernia As A Late Complication Of Roux-En-Y Gastric Bypass Procedure, Samantha Purton, Gabriel Meshekow, My Myers, Edgar Mercado, Allan Katz

West Florida Division Virtual Research Day 2020

As the prevalence of obesity continues to rise, so does the popularity of bariatric surgery. Previously the Roux-en-Y gastric bypass was the most common bariatric procedure, but now falls second to the gastric sleeve. It remains a relevant procedure, however, accounting for 17% of bariatric procedures in 2018. Due to its prevalence, it is important that the radiologist be familiar with the procedure and its complications such as leak, obstruction, stricture, or, as in this case, internal herniation through a mesenteric defect. Internal hernias are more commonly associated with the laparoscopic approach versus open. This is likely due to fewer …


Phantoms To Placentas: Mr Methods For Oxygen Quantification, Kelsey Meinerz May 2020

Phantoms To Placentas: Mr Methods For Oxygen Quantification, Kelsey Meinerz

Arts & Sciences Electronic Theses and Dissertations

Molecular oxygen (O2) is vital for efficient energy production and improper oxygenation is a hallmark of disease or metabolic dysfunction. In many pathologies, knowledge of tissue oxygen levels (pO2) could aid in diagnosis and treatment planning. The gold standard for pO2 measures in tissue are implantable probes, which are invasive, require surgery for placement, and are inaccessible to certain regions of the body. Methods for determining pO2 both non-invasively and quantitatively are lacking. The slight paramagnetic nature of O2 provides opportunities to non-invasively characterize pO2 in tissue via magnetic resonance (MR) techniques. As such, O2 can be treated as a …


Mechanical Thrombectomy For Acute Ischemic Stroke In The Cardiac Catheterization Laboratory., Steven A Guidera, Sudhir Aggarwal, J Doyle Walton, David Boland, Roy Jackel, Jeffrey D Gould, Brooke Kearins, Joseph Mcgarvey, Yan Qi, Brian Furlong Apr 2020

Mechanical Thrombectomy For Acute Ischemic Stroke In The Cardiac Catheterization Laboratory., Steven A Guidera, Sudhir Aggarwal, J Doyle Walton, David Boland, Roy Jackel, Jeffrey D Gould, Brooke Kearins, Joseph Mcgarvey, Yan Qi, Brian Furlong

Department of Radiology & Diagnostic Medical Imaging

OBJECTIVES: The aim of this study was to determine the feasibility of establishing a mechanical thrombectomy (MT) program for acute ischemic stroke in a community hospital using interventional cardiologists working closely with neurologists.

BACKGROUND: American Heart Association/American Stroke Association 2018 guidelines give a Class I (Level of Evidence: A) recommendation for MT in eligible patients with large vessel occlusion stroke. Improvement in neurological outcomes with MT is highly time sensitive. Most hospitals do not have trained neurointerventionalists to perform MT, leading to treatment delays that reduce the benefit of reperfusion therapy.

METHODS: An MT program based in the cardiac catheterization …


Analysis Of Ptv Margins For Vmat Treatment Of Rectal Cancers Utilizing Prone Bellyboard Device., Ben Armbuster Apr 2020

Analysis Of Ptv Margins For Vmat Treatment Of Rectal Cancers Utilizing Prone Bellyboard Device., Ben Armbuster

Culminating Experience Projects

Utilization of a bellyboard device reduces small bowel dose for patients receiving radiation therapy for rectal cancer. The reduction of small bowel dose with the bellyboard is even more significant in intensity modulated radiation therapy rectal treatments, as opposed to conventional 3D treatments. However, there is evidence of increased setup variation with prone bellyboard positioning, especially in pitch and roll. The purpose of this study is to determine the margin needed between the clinical target volume and the planning target volume to adequately account for these setup variations when planning volumetric modulated arc therapy rectal cases utilizing the bellyboard device. …


Pediatric Chest X-Rays, Liam Du Preez Jan 2020

Pediatric Chest X-Rays, Liam Du Preez

Larner College of Medicine Fourth Year Advanced Integration Teaching/Scholarly Projects

Chest Radiographs are the most commonly ordered diagnostic image in the pediatric population. These images are encountered often in both the early medical school curriculum and outside in the clinical setting. This module was generated with the goals of giving a framework for approaching pediatric chest x-rays, as well as showcasing common radiographic findings, both normal and pathologic.


Lead X-Ray Vests: Pros And Cons In Dental Radiography And Patient Education On Radiographic Technology, Kayla D. Oakley, Emily Deker Jan 2020

Lead X-Ray Vests: Pros And Cons In Dental Radiography And Patient Education On Radiographic Technology, Kayla D. Oakley, Emily Deker

Dental Hygiene Student Scholarship

Problem: There is a greater need to emphasize and educate patients and providers about radiologic advancements and patient exposure. The tradition of placing lead x-ray vests on patients for all radiographs is no longer a necessity. Without the explanation of why lead aprons are no longer needed, unnecessary steps for the provider and potential harm to the patient could be caused.

Methods: This review of literature was assembled by analyzing data from primary and secondary sources through online databases. The most recent research on the risks and benefits of the use of lead x-ray vests towards patients in …


What Is Scannable? An Mri Safety Guide, Michael Burcescu, Ravi Patel, Robert Hessemer, Peter Lore, Sriharsha Kota, Guarav Kumar Jan 2020

What Is Scannable? An Mri Safety Guide, Michael Burcescu, Ravi Patel, Robert Hessemer, Peter Lore, Sriharsha Kota, Guarav Kumar

West Florida Division Virtual Research Day 2020

Supernumerary MRI protocols and recommendations exist to guide physicians at the forefront of patient care. While urgent imaging may be necessary for critical patients, inadvertent imaging of implantable devices can incur serious morbidity and mortality[11]. The American College of Radiology published a 30-page manual in 2013[1] on MRI safe practices and releases yearly updates with critical information separately[2]. There is increased utilization of advanced imaging modalities, especially among academic institutions[3]. Physicians are hard pressed to maximize efficiency; uncertainty delays imaging. Moreover, inappropriate orders delay appropriate management. We present pertinent and often questioned considerations in a comprehensible format along with devices …