Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 7 of 7

Full-Text Articles in Speech and Hearing Science

Modelling Loudness: Acoustic And Perceptual Correlates In The Context Of Hypophonia In Parkinson’S Disease, Daryn Amory Cushnie-Sparrow Jun 2021

Modelling Loudness: Acoustic And Perceptual Correlates In The Context Of Hypophonia In Parkinson’S Disease, Daryn Amory Cushnie-Sparrow

Electronic Thesis and Dissertation Repository

Hypophonia (quiet speech) is a common speech symptom associated with Parkinson’s disease (PD), and is associated with reduced intelligibility, communicative effectiveness, and communicative participation. Studies of hypophonia commonly employ average speech intensity as the primary dependent measure, which may not entirely capture loudness deficits. Loudness may also be affected by the frequency components of speech (i.e. spectral balance) and speech level variability. The present investigation examined relationships between perceived loudness and intelligibility with acoustic measures of loudness, speech intensity, and spectral distribution in individuals with hypophonia secondary to Parkinson’s disease (IWPDs) and neurologically healthy older adults (HOAs).

Samples of sentence …


A Comparison Of Nal And Dsl Prescriptive Methods For Paediatric Hearing-Aid Fitting: Predicted Speech Intelligibility And Loudness, Teresa Y.C. Ching, Earl E. Johnson, Sanna Hou, Harvey Dillon, Vicky Zhang, Lauren Burns, Patricia Van Buynder, Angela Wong, Christopher Flynn Apr 2018

A Comparison Of Nal And Dsl Prescriptive Methods For Paediatric Hearing-Aid Fitting: Predicted Speech Intelligibility And Loudness, Teresa Y.C. Ching, Earl E. Johnson, Sanna Hou, Harvey Dillon, Vicky Zhang, Lauren Burns, Patricia Van Buynder, Angela Wong, Christopher Flynn

Earl E. Johnson

Objective: To examine the impact of prescription on predicted speech intelligibility and loudness for children. Design: A between-group comparison of speech intelligibility index (SII) and loudness, based on hearing aids fitted according to NAL-NL1, DSL v4.1, or DSL m[i/o] prescriptions. A within-group comparison of gains prescribed by DSL m[i/o] and NAL-NL2 for children in terms of SII and loudness. Study sample: Participants were 200 children, who were randomly assigned to first hearing-aid fitting with either NAL-NL1, DSL v4.1, or DSL m[i/o]. Audiometric data and hearing-aid data at 3 years of age were used. Results: On average, SII calculated on the …


A Comparison Of Nal And Dsl Prescriptive Methods For Paediatric Hearing-Aid Fitting: Predicted Speech Intelligibility And Loudness, Teresa Y.C. Ching, Earl E. Johnson, Sanna Hou, Harvey Dillon, Vicky Zhang, Lauren Burns, Patricia Van Buynder, Angela Wong, Christopher Flynn Dec 2013

A Comparison Of Nal And Dsl Prescriptive Methods For Paediatric Hearing-Aid Fitting: Predicted Speech Intelligibility And Loudness, Teresa Y.C. Ching, Earl E. Johnson, Sanna Hou, Harvey Dillon, Vicky Zhang, Lauren Burns, Patricia Van Buynder, Angela Wong, Christopher Flynn

ETSU Faculty Works

Objective: To examine the impact of prescription on predicted speech intelligibility and loudness for children. Design: A between-group comparison of speech intelligibility index (SII) and loudness, based on hearing aids fitted according to NAL-NL1, DSL v4.1, or DSL m[i/o] prescriptions. A within-group comparison of gains prescribed by DSL m[i/o] and NAL-NL2 for children in terms of SII and loudness. Study sample: Participants were 200 children, who were randomly assigned to first hearing-aid fitting with either NAL-NL1, DSL v4.1, or DSL m[i/o]. Audiometric data and hearing-aid data at 3 years of age were used. Results: On average, SII calculated on the …


Voice Level: Autophonic Scale, Perceived Loudness, And Effects Of Sidetone, H. L. Lane, A. C. Catania, S. S. Stevens Feb 2011

Voice Level: Autophonic Scale, Perceived Loudness, And Effects Of Sidetone, H. L. Lane, A. C. Catania, S. S. Stevens

Harlan Lane

The speaker's numerical estimation of his own vocal level, the autophonic response, was found to grow as the 1.1 power of the actual sound pressure produced. When listeners judged the loudness of another speaker's vocalization (the phoneme [a]), the exponent was 0.7. The disparity between these exponents suggests that the speaker does not rely solely upon his perception of loudness in judging his own relative vocal level. The minor role played by loudness in the autophonic judgment is further demonstrated by the fact that the form and exponent of the subjective scale for autophonic responses remain relatively invariant under wide …


Tracking The Time To Recovery After Induced Loudness Reduction (L), Yoav Arieh, Karen Kelly, Lawrence E. Marks May 2005

Tracking The Time To Recovery After Induced Loudness Reduction (L), Yoav Arieh, Karen Kelly, Lawrence E. Marks

Department of Psychology Faculty Scholarship and Creative Works

In induced loudness reduction (ILR), a strong tone causes the loudness of a subsequently presented weak tone to decrease. The aim of the experiment was to determine the time required for loudness to return to its initial level after ILR. Twenty-four subjects were exposed to 5, 10, 20, or 40 brief bursts of 2500-Hz pure tones at 80-dB SPL (inducers) and then tested in a series of paired comparison trials. Subjects compared the loudness of a weak target (2500 Hz at 60-dB SPL) to the loudness of a comparison tone at 500 Hz previously judged to match the target. The …


Time Course Of Loudness Recalibration: Implications For Loudness Enhancement, Yoav Arieh, Lawrence E. Marks Aug 2003

Time Course Of Loudness Recalibration: Implications For Loudness Enhancement, Yoav Arieh, Lawrence E. Marks

Department of Psychology Faculty Scholarship and Creative Works

Loudness recalibration, the effect of a relatively loud 2500-Hz recalibrating tone on the loudness of a relatively soft 2500-Hz target tone, was measured as a function of the interstimulus interval (ISI) between them. The loudness of the target tone, assessed by a 500-Hz comparison tone, declined when the ISI equaled or exceeded about 200 ms and leveled off at an ISI of about 700 ms. Notably, the target tone’s loudness did not change significantly at very short ISIs (<150 ms). The latter result is incompatible with the literature reporting loudness enhancement in this time window but is compatible with the suggestion made by Scharf, Buus, and Nieder [J. Acoust. Soc. Am. 112, 807–810 (2002)] that early measurements of enhancement were contaminated by the influence of the recalibrating tone on the comparison …


Recalibrating The Auditory System: A Speed–Accuracy Analysis Of Intensity Perception, Yoav Arieh, Lawrence E. Marks Jun 2003

Recalibrating The Auditory System: A Speed–Accuracy Analysis Of Intensity Perception, Yoav Arieh, Lawrence E. Marks

Department of Psychology Faculty Scholarship and Creative Works

Recalibration in loudness perception refers to an adaptation-like change in relative responsiveness to auditory signals of different sound frequencies. Listening to relatively weak tones at one frequency and stronger tones at another make the latter appear softer. The authors showed recalibration not only in magnitude estimates of loudness but also in simple response times (RTs) and choice RTs. RTs depend on the sound intensity and may serve as surrogates for loudness. Most important, the speeded classification paradigm also provided measures of errors. RTs and errors can serve jointly to distinguish changes in sensitivity from changes in response criterion. The changes …