Open Access. Powered by Scholars. Published by Universities.®
Engineering Science and Materials Commons™
Open Access. Powered by Scholars. Published by Universities.®
- Keyword
-
- Insulation (3)
- Adaptive façade (1)
- Building energy (1)
- Building envelope (1)
- Coils Ceramics Gas discharges Dielectric barrier discharge Dielectrics (1)
-
- Comfort (1)
- Cooling and daylight (1)
- Dynamic thermal insulation (1)
- Energy efficiency policy (1)
- FEM EEM (1)
- HDD (1)
- Heat energy (1)
- Heat loss (1)
- Heat transfer (1)
- Heating (1)
- Heating Degree Day (1)
- Heating pattern (1)
- Home energy (1)
- Home heating (1)
- OIT (1)
- Occupant (1)
- Occupant comfort (1)
- Optimising retrofit (1)
- Retrofit (1)
- Retrofit optimisation (1)
- Retrofit (1)
- Roller blind (1)
- Setpoint temperature (1)
- Steady (1)
- Thermal comfort (1)
- Publication
- File Type
Articles 1 - 8 of 8
Full-Text Articles in Engineering Science and Materials
Optimal Temperature-Actuated Control Of A Thermally-Insulated Roller Blind, Hani Alkhatib, Philippe Lemarchand, Brian Norton, Dominic O'Sullivan
Optimal Temperature-Actuated Control Of A Thermally-Insulated Roller Blind, Hani Alkhatib, Philippe Lemarchand, Brian Norton, Dominic O'Sullivan
Articles
By altering the thermal equilibria between internal and ambient environments, dynamic insulation can minimize heating and cooling building energy requirements. The performance of a thermally-insulated roller blind was evaluated both experimentally and via simulation studies. The variation of blind position was optimized to minimize building energy consumption, maintain thermal comfort, and minimize daylight discomfort for a particular system, location and conditions. The roller blind was adjusted between four positions, from fully-open to fully-closed, optimal indoor temperature switching thresholds found for moving to these blind positions were 15 °C, 18.4 °C, 19.4 °C and 21.4 °C, respectively. Using these resulted in …
Hdd Dataset: Optimising Retrofitted Insulation For Irish Residential Building Walls, Rakshit D. Muddu, Aimee Byrne, Anthony James Robinson
Hdd Dataset: Optimising Retrofitted Insulation For Irish Residential Building Walls, Rakshit D. Muddu, Aimee Byrne, Anthony James Robinson
Datasets
In this study, a thermal-economic analysis was conducted to determine the optimum insulation thickness of retrofitted insulation walls in different regions in Ireland. This was based on the Heating Degree Day method (HDD). This dataset contains optimum insulation thickness, payback period, cost savings and carbon emission for all 25 counties in the Republic of Ireland
Survey Data: Optimising Retrofitted Insulation For Irish Residential Building Walls, Rakshit D. Muddu, Aimee Byrne, Anthony Robinson Dr.
Survey Data: Optimising Retrofitted Insulation For Irish Residential Building Walls, Rakshit D. Muddu, Aimee Byrne, Anthony Robinson Dr.
Datasets
A survey was conducted to determine the preferred set point temperature and heating pattern among Irish households. The survey was sent to 237 people living across Ireland, out of which 32 respondents skipped the survey and 9 surveys were found to be incomplete. Amongst the counties in Ireland 71.1% respondents were from Dublin, 6.34% from Kildare, 5% from Meath, 5% from Wicklow and in all the remaining counties response rate was below 2%. Part 1: This section of the survey recorded information regarding characteristics of the building such as house type, wall type, insulation type, period the house was built. …
Fem Eem Dataset: Optimising Retrofitted Insulation For Irish Residential Building Walls, Rakshit D. Muddu, Aimee Byrne, Anthony Robinson Dr.
Fem Eem Dataset: Optimising Retrofitted Insulation For Irish Residential Building Walls, Rakshit D. Muddu, Aimee Byrne, Anthony Robinson Dr.
Datasets
A large number of combinations of Irish wall types, insulation materials, and heating fuel types were produced to compare the multiple variables which influence Optimal Insulation Thickness values. The total cost (TC) and carbon emission (CE) at optimum insulation thickness (OIT) for all combinations of insulation material and three types of fuel are considered. The dataset presents OIT for solid wall, cavity wall and cavity block wall types located in Monaghan, Dublin, and Kerry.
Compact Facility For Testing Steady And Transient Thermal Performance Of Building Walls, Aimee Byrne, Gerard Byrne, Anthony Robinson
Compact Facility For Testing Steady And Transient Thermal Performance Of Building Walls, Aimee Byrne, Gerard Byrne, Anthony Robinson
Articles
Energy efficiency retrofit of buildings represents a key effort in reducing EU energy demand by 20% by 2020. However, predictions tend to overestimate savings by large percentages. The shortfall in savings can be attributed to incorrect predictive techniques, comfort takeback along with other behavioural and workmanship variables. Common predictive techniques related to heat loss tend to be based on the U-value of the building envelope. This paper presents the design of a more straightforward and compact version of the traditional Hot-Box apparatus (measures U-value) which instead determines the thermal resistance of samples of building envelope. U-value includes the need to …
Case Studies Of Cavity And External Wall Insulation Retrofitted Under The Irish Home Energy Saving Scheme: Technical Analysis And Occupant Perspectives, Aimee Byrne, Gerard Byrne, Garrett O'Donnell, Anthony Robinson
Case Studies Of Cavity And External Wall Insulation Retrofitted Under The Irish Home Energy Saving Scheme: Technical Analysis And Occupant Perspectives, Aimee Byrne, Gerard Byrne, Garrett O'Donnell, Anthony Robinson
Articles
The residential sector represents 27% of primary energy consumption in Ireland. This paper examines the case study of the Irish government’s national grant scheme to encourage energy efficiency retrofit in private housing. That is the Home Energy Saving (HES) Scheme, later rebranded the Better Energy: Homes (BEH) Scheme. The methodology involved monitoring several homes immediately before and after retrofit alongside discussions with occupants. The examination focused on specific measures commonly introduced through the HES/BEH programme − cavity and external wall insulation. It has been found that a significant decrease in heat loss through the walls was measured in all cases. …
Hand-Held Flyback Driven Coaxial Dielectric Barrier Discharge: Development And Characterization, Victor J. Law, Vladimir Milosavljevic, Neil O’Connor, James F. Lalor, Steven Daniels
Hand-Held Flyback Driven Coaxial Dielectric Barrier Discharge: Development And Characterization, Victor J. Law, Vladimir Milosavljevic, Neil O’Connor, James F. Lalor, Steven Daniels
Articles
The development of a handheld single and triple chamber atmospheric pressure coaxial dielectric barrier discharge driven by Flyback circuitry for helium and argon discharges is described. The Flyback uses external metal-oxide-semiconductor field-effect transistor power switching technology and the transformer operates in the continuous current mode to convert a continuous dc power of 10–33 W to generate a 1.2–1.6 kV 3.5 μs pulse. An argon discharge breakdown voltage of ∼768 V is measured. With a 50 kHz, pulse repetition rate and an argon flow rate of 0.5–10 argon slm (slm denotes standard liters per minute), the electrical power density deposited in …
Comparison Of Vacuum Glazing Thermal Performance Predicted Using Two- And Three-Dimensional Models And Their Experimental Validation, Brian Norton, Philip Eames, Yueping Fang, Trevor Hyde, Neil Hewitt
Comparison Of Vacuum Glazing Thermal Performance Predicted Using Two- And Three-Dimensional Models And Their Experimental Validation, Brian Norton, Philip Eames, Yueping Fang, Trevor Hyde, Neil Hewitt
Conference Papers
The thermal performance of vacuum glazing was predicted using two dimensional (2-D) finite element and three dimensional (3-D) finite volume models. In the 2-D model, the vacuum space, including the pillar arrays, was represented by a material whose effective thermal conductivity was determined from the specified vacuum space width, the heat conduction through the pillar array and the calculated radiation heat transfer between the two interior glass surfaces within the vacuum gap. In the 3-D model, the support pillar array was incorporated and modeled within the glazing unit directly. The difference in predicted overall heat transfer coefficients between the two …