Open Access. Powered by Scholars. Published by Universities.®

Controls and Control Theory

Institution
Keyword
Publication Year
Publication
Publication Type

Articles 31 - 38 of 38

Full-Text Articles in VLSI and Circuits, Embedded and Hardware Systems

At89c51 Microcontroller Based Control Model For Hybrid Assistive Limb (Knee ), Suresh L Jan 2013

At89c51 Microcontroller Based Control Model For Hybrid Assistive Limb (Knee ), Suresh L

suresh L

In this paper, a controlling system is implemented for a wearable walking supporting device so called as Hybrid Assistive Limb. The control circuit is implemented without considering the biological signals of the human body for the knee part, which is based on the knee joint moment from the human body model. The control and a driving circuit s are implemented to assistive the knee as for the requir ement of knee joint dynamics.


Battery Energy Storage System In Solar Power Generation, Radhey Shyam Meena Er. Jan 2013

Battery Energy Storage System In Solar Power Generation, Radhey Shyam Meena Er.

Radhey Shyam Meena

As solar photovoltaic power generation becomes more commonplace, the inherent intermittency of the solar resource poses one of the great challenges to those who would design and implement the next generation smart grid. Specifically, grid-tied solar power generation is a distributed resource whose output can change extremely rapidly, resulting in many issues for the distribution system operator with a large quantity of installed photovoltaic devices. Battery energy storage systems are increasingly being used to help integrate solar power into the grid. These systems are capable of absorbing and delivering both real and reactive power with sub-second response times. With these …


Smart Wall Plug Design For The Dc House Project, Edward Constant Sibal Dec 2012

Smart Wall Plug Design For The Dc House Project, Edward Constant Sibal

Master's Theses

The DC House project at Cal Poly State University faces a challenge of supplying DC voltage to household appliances. Each appliance in the DC House constitutes a DC load that has a unique voltage and power rating, hence the need to develop a smart DC wall plug that will automatically adjust to the operating voltage required by any DC load. This thesis entails a proof of concept design of the smart DC wall plug which can automatically detect an appliance’s voltage rating. The design employs a dc-dc converter in conjunction with a microcontroller to sense load current to properly adjust …


Switch Yard Operation In Thermal Power Plant(Katpp Jhalawar Rajasthan), Radhey Shyam Meena Er. Jul 2012

Switch Yard Operation In Thermal Power Plant(Katpp Jhalawar Rajasthan), Radhey Shyam Meena Er.

Radhey Shyam Meena

Switchyard Provides the facilities for switching ,protection & Control of electric power. To handle high Voltage power with proper Safety measures. To isolate the noises coming from the grid with true 50Hz power SWITCH YARD IS IMPORTANT PART IN THERMAL PLANT. IN KALISINDH THERMAL 400KV AND 220KV SWITCH YARD LOCATED.


Control System For Glucose Detector System, David Smith Jun 2012

Control System For Glucose Detector System, David Smith

Electrical Engineering

In this paper I design and test on a prove of concept level a control/timing circuit for a blood glucose detector built in a previous senior project. The specifications of the design given are to properly power the detector with a low power source. The design is completed on a transistor level basis using Cadence Virtuoso Software. The system is design from the ground up; designing, building, and testing smaller circuits first then combined into increasingly larger circuits till the completed circuit is finished. The design used to based off of the 555 Timer and uses differential pairs, CMOS designed …


Modeling And Simulation Of Z-Source Inverter, Suresh L Jan 2012

Modeling And Simulation Of Z-Source Inverter, Suresh L

suresh L

Z – source inverters have been recently proposed as an alternative power conversion concept as they have both voltage buck and boost capabilities. These inverters use a unique impedance network, coupled between the power source and converter circuit, to provide both voltage buck and boost properties, which cannot be achieved with conventional voltage source and current source inverters. To facilitate understanding of Z – source inverter, this paper presents a detailed analysis, showing design of impedance network, implementation of simple Boost control PWM technique and simulation of Z – source inverter for different values of modulation indices.


Development Of A Novel Methodology For Indoor Emission Source Identification, Kwanghoon Han Mar 2011

Development Of A Novel Methodology For Indoor Emission Source Identification, Kwanghoon Han

Kwanghoon Han

The objective of this study was to develop and evaluate a methodology to identify individual sources of emissions based on the measurements of mixed air samples and the emission signatures of individual materials previously determined by Proton Transfer Reaction-Mass Spectrometry (PTR-MS), an on-line analytical device. The methodology based on signal processing principles was developed by employing the method of multiple regression least squares (MRLS) and a normalization technique. Samples of nine typical building materials were tested individually and in combination, including carpet, ceiling material, gypsum board, linoleum, two paints, polyolefine, PVC and wood. Volatile Organic Compound (VOC) emissions from each …


Determination Of Material Emission Signatures By Ptr-Ms And Their Correlations With Odor Assessments By Human Subjects, Kwanghoon Han Apr 2010

Determination Of Material Emission Signatures By Ptr-Ms And Their Correlations With Odor Assessments By Human Subjects, Kwanghoon Han

Kwanghoon Han

The objectives of this study were to determine volatile organic compound (VOC) emission signatures of nine typical building materials by using proton transfer reaction-mass spectrometry (PTR-MS) and to explore the correlation between the PTR-MS measurements and the measurements of acceptability by human subjects. VOC emissions from each material were measured in a 50-l small-scale chamber. Chamber air was sampled by PTR-MS to determine emission signatures. Sorbent tube sampling and TD-GC/MS analysis were also performed to identify the major VOCs emitted and to compare the resulting data with the PTR-MS emission signatures. The data on the acceptability of air quality assessed …