Shear Strength Of Concrete Beams Made With Belitic Calcium Sulfoaluminate Cement, Caleb W. Chesnut Dec 2021

Shear Strength Of Concrete Beams Made With Belitic Calcium Sulfoaluminate Cement, Caleb W. Chesnut

Graduate Theses and Dissertations

The need for a cleaner alternative to portland cement (PC) concrete has led to increasing interest in alternatives to PC. Structural properties of most of these alternative cements are still an open research topic. One promising alternative cement is belitic calcium sulfoaluminate (BCSA) cement. The study presented in this paper investigated the shear strength, long term compressive strength, and carbonation in BCSA cement and PC concrete beams. A total of twelve eight-foot long beams were made; eight BCSA cement concrete beams and four PC concrete beams to be tested at various ages depending on cement type. Two beams of each …


Steel Test Set-Up For Non-Ductile Concrete Shear Walls, Colin S. Ridgley Jun 2019

Steel Test Set-Up For Non-Ductile Concrete Shear Walls, Colin S. Ridgley

Architectural Engineering

The purpose of this project was to provide a robust test set-up for the thesis work being conducted by graduate students, Jerry Luong & Rory de Sevilla. Their research aims to evaluate the feasibility of using fiber-reinforced polymer wraps and splay anchors to retrofit non-ductile concrete shear walls through a series of tests on reinforced concrete walls.

Four key constraints governed the design of the test set-up. First, the wall can be cyclically, laterally loaded to develop data for comparison with theoretical analysis methods. Second, the wall can be axially loaded to simulate interaction effects and prevent a sliding failure …


Reliability-Based Shear Rating Of Prestressed Concrete Bridge Girders Considering Capacity Adjustment Factor, Alaa I. Chehab, Christopher D. Eamon Mar 2019

Reliability-Based Shear Rating Of Prestressed Concrete Bridge Girders Considering Capacity Adjustment Factor, Alaa I. Chehab, Christopher D. Eamon

Civil and Environmental Engineering Faculty Research Publications

In this study, the reliability of prestressed concrete (PC) bridge girders in the shear rating process is quantified, where the use of a simple procedure to enhance the accuracy of shear capacity evaluation for rating is evaluated. It was found that the approximate methods used in code-based procedures to develop shear resistance used for reliability calibration of the AASHTO Bridge Design Specifications and the Manual for Bridge Evaluation result in larger discrepancies in reliability than previously assumed, as well as substantially conservative shear capacity evaluation in most cases. To examine the effects of using a more accurate shear rating process, …


Partial Material Strength Reduction Factors For Aci 318, Tong Zhang Nov 2017

Partial Material Strength Reduction Factors For Aci 318, Tong Zhang

Electronic Thesis and Dissertation Repository

The strength reduction factors, phi, defined in ACI 318-14 for different structural actions and elements lead to inconsistent results. This study proposes partial material strength reduction factors for concrete, phic, and reinforcing steel, phis, that yield similar design strengths and more consistent reliability indices. Three structural actions are investigated: moment; shear; and, combined moment and axial force. The first-order, second-moment method is used to compute reliability indices for moment and shear, and Monte Carlo simulation is used for combined moment and axial force. The statistical parameters assumed for the professional factor for shear strength significantly impact …


Behaviour Of Helical Pile Connectors For New Foundations, Muhammad Ahmad Muhammad Diab Sep 2015

Behaviour Of Helical Pile Connectors For New Foundations, Muhammad Ahmad Muhammad Diab

Electronic Thesis and Dissertation Repository

Despite the wide application of the connections between slender pile types, which end with a mono steel bar at the ground level (e.g. helical piles and micro piles), and new reinforced concrete foundations with limited width (e.g. RC grade beams) in the piling industry in North America, neither a clear understanding of the connections' behaviour nor a specific design criteria for their implementation is presented.

The main goal of this research was to clearly understand the behaviour of these connections and their failure mechanism under monotonic and cyclic loadings. The research methodology involved conducting experimental tests on 33 full-scale pile-foundation …


Experimental And Numerical Development Of Anchor-Jointed Precast Structural Wall System And Optimum Design Of Prestressed Slabs, Mohamed El Semelawy May 2011

Experimental And Numerical Development Of Anchor-Jointed Precast Structural Wall System And Optimum Design Of Prestressed Slabs, Mohamed El Semelawy

Electronic Thesis and Dissertation Repository

Precast concrete shear walls are used to resist lateral loads in low- to medium-rise buildings. An innovative joining technique is proposed to accelerate construction process and to reduce concrete damage possibility and capital loss during an earthquake event. Panels are jointed using steel anchor bolts, therefore, the system is designated "anchor-jointed precast structural wall system". In this system, anchors are utilized as a structural fuse. Damaged anchors are easily replaced after an earthquake, thus minimizing repair costs and serviceability disruptions. In the first part of this thesis, conceptual development of the system is carried out. A research program of combined …


Performance Of Cold-Formed Steel-Framed Shear Walls: Alternative Configurations, Kelly A. Morgan, Mark A. Sorhouet, Reynaud Serrette Jun 2002

Performance Of Cold-Formed Steel-Framed Shear Walls: Alternative Configurations, Kelly A. Morgan, Mark A. Sorhouet, Reynaud Serrette

American Iron and Steel Institute (AISI) Specifications, Standards, Manuals and Research Reports (1946 - present)

This report presents the results of twenty shear wall tests that were conducted to evaluate the performance of wall configurations not currently (2002) permitted in the building codes. Ten (10) walls were evaluated under reversed cyclic loading and the other ten (10) under monotonic loading. Brief descriptions of the test program and results are presented in the following paragraphs. The reversed cyclic load tests comprised 4 ft. x 8 ft. 54- and 68-mil framed walls with 7/16-in. OSB rated sheathing on one or both sides of the wall and 33-mil framed walls with 27-mil sheet steel. The sheet steel wall …