Open Access. Powered by Scholars. Published by Universities.®

Biomedical Engineering and Bioengineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 6 of 6

Full-Text Articles in Biomedical Engineering and Bioengineering

Comparison Of Cone Mosaic Metrics From Images Acquired With The Spectralis High Magnification Module And Adaptive Optics Scanning Light Ophthalmoscopy, Niamh Wynne, Heather Heitkotter, Erica N. Woertz, Robert F. Cooper, Joseph Carroll May 2022

Comparison Of Cone Mosaic Metrics From Images Acquired With The Spectralis High Magnification Module And Adaptive Optics Scanning Light Ophthalmoscopy, Niamh Wynne, Heather Heitkotter, Erica N. Woertz, Robert F. Cooper, Joseph Carroll

Biomedical Engineering Faculty Research and Publications

Purpose: To compare cone mosaic metrics derived from adaptive optics scanning light ophthalmoscopy (AOSLO) images with those derived from Heidelberg Engineering SPECTRALIS High Magnification Module (HMM) images.

Methods: Participants with contiguous cone mosaics had HMM imaging performed at locations superior and temporal to the fovea. These images were registered and averaged offline and then aligned to split-detection AOSLO images; 200 × 200-µm regions of interest were extracted from both modalities. Cones were semi-automatically identified by two graders to provide estimates of cone density and spacing.

Results: Thirty participants with contiguous cone mosaics were imaged (10 males, 20 females; age range, …


Developing An Imaging Biomarker To Detect Aberrant Brain Connectivity In Individual Patients, Esther Cox Apr 2017

Developing An Imaging Biomarker To Detect Aberrant Brain Connectivity In Individual Patients, Esther Cox

Master's Theses (2009 -)

Resting state functional MRI (rsfMRI) has been proven to be a valuable tool in clinical applications such as pre-surgical mapping, but there is not yet a functional and usable algorithm that can be used by physicians in a clinical setting to evaluate an individual patient for diseases and aberrant brain connectivity. If a physician wants to evaluate a patient in this way, the rsfMRI data must be looked at “by hand,” i.e. the physician must manually evaluate the data and identify the functional ICN’s and whether they are normal or aberrant. An algorithm that would automate this process and supplement …


Photoreceptor Inner Segment Morphology In Best Vitelliform Macular Dystrophy, Drew Scoles, Yusufu N. Sulai, Robert F. Cooper, Brian P. Higgins, Ryan D. Johnson, Joseph Carroll, Alfredo Dubra, Kimberly E. Stepien Oct 2016

Photoreceptor Inner Segment Morphology In Best Vitelliform Macular Dystrophy, Drew Scoles, Yusufu N. Sulai, Robert F. Cooper, Brian P. Higgins, Ryan D. Johnson, Joseph Carroll, Alfredo Dubra, Kimberly E. Stepien

Biomedical Engineering Faculty Research and Publications

PURPOSE

To characterize outer retina structure in best vitelliform macular dystrophy (BVMD) and to determine the effect of macular lesions on overlying and adjacent photoreceptors.

METHODS

Five individuals with BVMD were followed prospectively with spectral domain optical coherence tomography and confocal and nonconfocal split-detector adaptive optics scanning light ophthalmoscopy (AOSLO). The AOSLO cone photoreceptor mosaic images were obtained within and around retinal lesions. Cone density was measured inside and outside lesions. In 2 subjects, densities were compared with published measurements acquired ∼2.5 years before. One subject was imaged 3 times over a 5-month period.

RESULTS

The AOSLO imaging demonstrated that …


A Novel Fmri Paradigm Suggests That Pedaling-Related Brain Activation Is Altered After Stroke, Nutta-On Promjunyakul, Brian D. Schmit, Sheila M. Schindler-Ivens Jan 2015

A Novel Fmri Paradigm Suggests That Pedaling-Related Brain Activation Is Altered After Stroke, Nutta-On Promjunyakul, Brian D. Schmit, Sheila M. Schindler-Ivens

Physical Therapy Faculty Research and Publications

The purpose of this study was to examine the feasibility of using functional magnetic resonance imaging (fMRI) to measure pedaling-related brain activation in individuals with stroke and age-matched controls. We also sought to identify stroke-related changes in brain activation associated with pedaling. Fourteen stroke and 12 control subjects were asked to pedal a custom, MRI-compatible device during fMRI. Subjects also performed lower limb tapping to localize brain regions involved in lower limb movement. All stroke and control subjects were able to pedal while positioned for fMRI. Two control subjects were withdrawn due to claustrophobia, and one control data set was …


Tools For Creating Wide-Field Views Of The Human Retina Using Optical Coherence Tomography, Ashavini M. Pavaskar Jul 2011

Tools For Creating Wide-Field Views Of The Human Retina Using Optical Coherence Tomography, Ashavini M. Pavaskar

Master's Theses (2009 -)

Optical Coherence Tomography (OCT) has allowed in-vivo viewing of details of retinal layers like never before. With the development of spectral domain OCT (SD-OCT) details of nearly 2µm axial resolution and higher imaging speed have been reported. Nevertheless, a single volume scan of the retina is typically restricted to 6mm x 6mm in size. Having a larger field of view of the retina will definitely enhance the clinical utility of the OCT.

A tool was developed for creating wide-field thickness maps of the retina by combining the use of already available tools like i2k Retina (DualAlign, LLC, Clifton Park, NY) …


Imaging Radiation Pneumonitis In A Rat Model Of A Radiological Terrorism Incident, Robert C. Molthen, Qingping Wu, Gary S. Krenz, Meetha Medhora, Elizabeth R. Jacobs, John E. Moulder Feb 2009

Imaging Radiation Pneumonitis In A Rat Model Of A Radiological Terrorism Incident, Robert C. Molthen, Qingping Wu, Gary S. Krenz, Meetha Medhora, Elizabeth R. Jacobs, John E. Moulder

Biomedical Engineering Faculty Research and Publications

We have developed a rat model of single, sub-lethal thoracic irradiation. Our irradiation protocol is considered representative of exposures near the detonation site of a dirty bomb or small nuclear device. The model is being used to investigate techniques for identifying, triaging and treating possible victims. In addition to physiological markers of right ventricular hypertrophy, pulmonary vascular resistance, and arterial distensibility, we present two methods for quantifying microvascular density. We used methods including microfocal X-ray imaging to investigate changes in lung structure/function resulting from radiation exposure. Radiation pneumonitis is a complication in subjects receiving thoracic irradiation. A radiographic hallmark of …